Hi-Rel LIMITOR MODULE
LGDS-100 : up to 100W POWER
• Ultra compact limitor module
• Transient suppressor module 202V
• DEF-STAN-61-5 Part 6 Issue 6,
• Transient suppressor module 100V
• MIL-STD-1275A/B/C/D,
• Transient suppressor module 80V
• MIL-STD-704A/D/E/F, EN2282, AIR2021E
• DO160E cat A, B and Z
• Power range : up to 90W/100W
• Inrush current limitation
• RoHS process
Gaia Converter FC12-045.02/12 Revision A
©
REDEFINING THE SOURCE OF POWER
1- General
Hi-Rel
Grade
For locations, phone, fax, E-Mail see back cover
2- Product Selection
Input Voltage Range
K
Output
The GAIA Converter limitor LGDS-100 is an ultra
compact power adaptator module designed to
allow operation during voltage transients and
spikes, occuring in avionics or military systems.
The LGDS-100 delivers an output voltage adapted
to GAIA Converter DC/DC modules. This module
is optimized to provide high power efficiency up
to 98%.
The LGDS-100 features 3 modes of operations
as follow:
Normal operation :
Normal operation occurs in between the per-
manent input voltage of the DC/DC converter;
The LGDS-100 is then operating in steady
transparency state.
Power fail operation :
The power fail operation occurs when the
input bus drops below 9 Vdc low voltage
limit ; an undervoltage lock-out stops the
LGDS-100.
Transient
P : 202V/350ms
Transient operation :
The LGDS-100 clamps input transient up
to 202V/350ms, or 101V/400ms.
The LGDS-100 series is compliant with the inter-
national input bus standards :
- DEF-STAN-61-5 Part 6 Issue 6
- MIL-STD-1275A/B/C/D
- MIL-STD-704A/D/E/F
- AECMA EN2282
- GAM-EG13B/AIR2021E
- DO160E cat A, B and Z
The design has been carried out with
surface mount components and is manufactured
in a fully automated process to guarranty high
quality. Every module is tested with a Gaïa
Converter automated test equipment. The mo-
dules are potted with a bi-component thermal
conductive compound and packaged in a metallic
case to ensure the module’s integrity under
severe environmental conditions.
4
100V and 200V Transient Protection Module
DEF-STAN 61-5 Part 6 & MIL-STD-1275
Metallic Case
LGDS - 100 - input output option
/
Options :
/T : option for -55°C start up operating temperature
/S : option for screening and serialization
For locations, phone, fax, E-Mail see back cover
2
LGDS-100 Series
Gaia Converter FC12-045.02/12 Revision A
©
4
Hi-Rel
Grade
0 20 40 60 80 100 120 140 160 180 200
0
5
10
15
20
25
30
35
40
45
Input voltage (Vdc)
output voltage (Vdc)
Transient operation
area
Normal operation
area
Power fail
operation area
3- Modes of Operation
LGDS-100 Transfer Function
Transient Mode
(Vout=Vlim)
Power fail Mode
(output disabled)
Start-up
Vin>Vst
OCP
Surge
End of
Surge
OTP
OTP : Over Temperature Protection
OCP : Over Current Protection
Normal Mode
(Vout=Vin-Vdrop)
UVLO
3-1 LGDS-100 Modes of Operation
The LGDS-100-P-K operates with H input family of GAIA
Converter DC/DC Converters.
The LGDS-100-P-K features 3 modes of operations as
described in the following state diagram :
Normal operation :
Normal operation occurs in between 9V and 42V input
voltage; the module is then operating in steady
transparency state.
Power fail operation :
When a failure occurs such as an undervoltage, an
over current or an over temperature, the LGDS-100
turns to power fail mode and stops operation until
the failure is removed. The LGDS-100 features 3 pro-
tection functions : input undervoltage lockout (UVLO),
output over current protection (OCP) and over
temperature protection (OTP).
Transient operation :
When a surge occurs, the LGDS-100 turns to transient
mode operation. It clamps input transient up to 202V
as long as 350ms and 101V during 400ms .
During this transient mode, the over current protec-
tion (OCP) is activated in order to prevent applica-
tions failure.
For locations, phone, fax, E-Mail see back cover
3
LGDS-100 Series
Gaia Converter FC12-045.02/12 Revision A
©
4
Hi-Rel
Grade
4- Electrical Specifications
Data are valid at +25°C, unless otherwise specified.
Parameter Conditions Limit or
typical Units LGDS-100
Input
Permanent input
voltage range (Ui)
in normal operation
Full temperature range
Full load
Minimum
Maximum
VDC
VDC
9
42
Compliance with
standards voltage
transient limit
Full temperature range
Maximum
Maximum
DEF-STAN-61-5-6-6
DEF-STAN-61-5-6-6
MIL-STD-1275A/D
MIL-STD-704A/F
AECMA EN2282
AIR2021E
DO160E cat A/Z
VDC/ms
VDC/s
202V/350ms
101V/400ms
100V/50ms
80V/75ms
60V/50ms
60V/100ms
80V/100ms
202V/350ms
48V/1s
Compliant
Compliant
Compliant
Compliant
Compliant
Compliant
Compliant
Compliance with
standards voltage
spike limit
*with filter (see 8)
** with companion
filter FGDS series
50 Ohms impedance
15 mJ energy content
50 Ohms impedance
50 Ohms impedance
50 Ohms impedance
50 Ohms impedance
DEF-STAN-61-5-6-6
MIL-STD-1275A/D
MIL-STD-704A/F
AECMA EN2282
AIR2021E
DO160E cat A/Z
228V/0,2µs
250V/70µs
600V/10µs
400V/100µs
600V/10µs
600V/10µs
Compliant*
Compliant**
Compliant**
Compliant**
Compliant**
Compliant**
Under voltage
lock- out (UVLO) Turn-on/Turn-off threshold Minimum
Maximum
VDC
VDC
7
9
Start up time Ui nominal 28V
Full load Maximum ms 6
Inrush current
limitation
Full temperature range
C=1000µF Typical A 5
No load input
current
Ui nominal 28V
No load Maximum mA 10
Output
Nominal voltage in
normal operation
Ui < 42V
Full load Minimum / Ui - 125mV
Nominal voltage in
transient
protection mode
In transient
Input voltage range
Minimum
Nominal
Maximum
VDC
VDC
VDC
40
42
44
Output voltage
slew rate During start-up time Typical VDC/ms 5
Output current Full temperature range
Ui min. to max. Maximum A 10 (or 100W)
Output Power Full temperature range
Ui min. to max. Maximum W see page 4
figure 3
Power dissipation Ui nominal 28V
Output current 10A Maximum W 1,55
For locations, phone, fax, E-Mail see back cover
4
LGDS-100 Series
Gaia Converter FC12-045.02/12 Revision A
©
4
Hi-Rel
Grade
0 20 40 60 80 100 120 140 160 180 200
0
10
20
30
40
50
60
70
80
90
100
Vin (Vdc)
Pout (W)
42
9
Transient
Operation
area
Permanent
operation
area
4- Electrical Characteristics (continued)
Figure 4 : LGDS-100-P-K Start-up Timing
Figure 1 : LGDS-100-P-K Transient Response at 202Vdc
(according to DEF-STAN-61-5 Part 6 Issue 6)
Figure 2 : LGDS-100-P-K Transient Response at 100Vdc
(according to MIL-STD-1275D)
Figure 3 : LGDS-100-P-K Output Power versus Input Voltage
@ Tcase max. for DEF-STAN 61-5 part 6 Issue 6
For locations, phone, fax, E-Mail see back cover
5
LGDS-100 Series
Gaia Converter FC12-045.02/12 Revision A
©
4
Hi-Rel
Grade
6- Protection Functions
Characteristics Protection Device Recovery Limit or
typical Specifications
Output over current protection (OCP) Hiccup circuitry with
auto-recovery
Automatic
recovery Permanent See section 10
Over temperature protection (OTP) Thermal device with
hysteresis cycle
Automatic
recovery Nominal 120°C
7- Reliability Data
5- Isolation
Characteristics Conditions Temperature Specifications
Mean Time Between Failure (MTBF)
According to MIL-HDBK-217F
Ground fixed (Gf) Case at 40°C
Case at 85°C
1 300 000 Hrs
425 000 Hrs
Airborne, Inhabited,
Cargo (AIC)
Case at 40°C
Case at 85°C
675 000 Hrs
250 000 Hrs
Mean Time Between Failure (MTBF)
According to IEC-62380-TR
Civilian avionics,
calculators
Ambient at 55°C
100% time on 1 800 000 Hrs
Parameter Conditions Limit or
typical Specifications
Electric strength test voltage Input to output
All pins to case
/
Minimum
No isolation
500 VDC / 1 min
Isolation resistance 50 VDC, all pins to case Minimum 100 MOhm
For locations, phone, fax, E-Mail see back cover
6
LGDS-100 Series
Gaia Converter FC12-045.02/12 Revision A
©
4
Hi-Rel
Grade
8- Electromagnetic Interference
Electromagnetic interference requirements for an architecture using LGDS-100 and GAIA Converter DC/DC module
according to DEF STAN 59-411 or MIL-STD-461D/E/F or D0-160D/E/F can be easily achieved as indicated in the
following table with the use of an additionnal external filter as suggested hereafter.
Standards DEF STAN 59-411 DO-160D MIL-STD-461E Compliance
Conducted emission (CE) :
Low frequency
High frequency DCE01 Section 21 CE 101
CE 102
compliant module stand alone
compliant with additionnal filter
Conducted susceptibility (CS) :
Low frequency
High frequency
DCS01
DCS02 Section 20 CS 101
CS 114
compliant with additionnal filter
compliant with additionnal filter
Radiated emission (RE) :
Magnetic fireld
Electrical field
DRE02
DRE01 Section 21 RE 101
RE 102
compliant module stand alone
compliant module stand alone
Radiated susceptibility (RS) :
Magnetic field
Electrical field
DRS01
DRS02 Section 20 RS 101
RS 013
compliant module stand alone
compliant module stand alone
Recommended list of components :
L1, L2 ............... : Common mode choke 590µH current 5,6A (type Pulse PO353 or other common mode choke with
higher value than 250µH and rated according to maximum current)
C1...................... : Ceramic chip capacitors 2 x 2.2µF/100V 1210 (example Murata GRM32ER71H475KA88 or other
ceramic chip capacitors connected in parallel with an equivalent total value)
C2, C3, C6, C7..... : Film chip capacitor 10 nF/500V (example AVX : 1206 7 C 103 M)
C4 ,C8 ................ : Ceramic chip capacitors 10 x 2.2µF/100V 1210 (example Murata GRM32ER71H475KA88 or other
ceramic chip capacitors connected in parallel with an equivalent total value)
C5, C9 ............... : Tantalum or aluminium electrolytic capacitor 47 to 100µF/250V (with low ESR)
C4 C5
C2
C3
C1
L1 L2
C8
C6
C7 C9
Vi
Gi
Vo
Go
EMI Filter Suggested Schematic
EMI Input Filter
The LGDS-100 is compliant with :
- GAIA converter ready-to-use EMI filter LGDS series for any MIL-STD-461D/E/F, DO-160D/E/F requirements,
(see FGDS datasheet for details).
- specific component design EMI filter for compliance with DEF STAN 59-411 requirements and DEF-STAN 61-5
transient levels (see figure hereafter).
Note on C* : for stability purpose recommends the use of a 220µF/50V capacitor after the LGDS-100.
For locations, phone, fax, E-Mail see back cover
7
LGDS-100 Series
Gaia Converter FC12-045.02/12 Revision A
©
4
Hi-Rel
Grade
9- Thermal Characteristics
Characteristics Conditions Limit or typical Performances
Operating ambient temperature
range at full load Ambient temperature * Minimum
Maximum
- 40°C
+ 85°C
Operating case temperature
range at full load Case temperature Minimum
Maximum
- 40°C
+105°C
Storage temperature range Non functionning Minimum
Maximum
- 55°C
+ 125°C
Thermal resistance Rth case to ambient in free air
natural convection Typical 12°C /W
Note * : The upper temperature range depends on configuration, the user must assure a max. case temperature of + 105°C.
10 30 807060 9020 40 50
25%
75%
50%
100%
Power (W)
Temperature (˚C)
Full load ambient temperature without derating : 75˚C
Maximum case temperature : 105˚C
Natural convection operation area
Additionnal cooling operation area
Maximum storage temperature : 125˚C
The LGDS-100 series operating case temperature at full load must not exceed 105°C. The maximum ambient temperature
admissible for the DC/DC converter corresponding to the maximum operating case temperature of 105°C depends on the
ambient airflow, the mounting/orientation, the cooling features and the power dissipated.
To calculate a maximum admissible ambient temperature the following method can be used. Knowing the maximum case
temparature Tcase = 105°C of the module, the power used Pout and the efficiency η :
• determine the power dissipated by the module Pdiss that should be evacuated :
Pdiss = Pout(1/ηη
ηη
η - 1)
• determine the maximum ambient temperature :
Ta = 105°C - Rth x Pdiss
where Rth is the thermal resistance from the case to ambient.
The previous thermal calculation shows two areas of operation :
• a normal operation area in a free natural ambient convection (grey area in the following graph),
• an area with cooling features (air flow or heatsink) ensuring a maximum case temperature below the maximum
operating case temperature of 105°C at full load (white area in the following graph).
For locations, phone, fax, E-Mail see back cover
8
LGDS-100 Series
Gaia Converter FC12-045.02/12 Revision A
©
4
Hi-Rel
Grade
10- Environmental Qualifications
The modules have been subjected to the following environmental qualifications.
Characteristics Conditions Severity Test procedure
Climatic Qualifications
Life at high
temperature
Duration
Temperature / status of unit Test D : 1 000 Hrs
@ 125°C ambient, unit not operating
MIL-STD-202G
Method 108A
Altitude
Altitude level C
Duration
Climb up
Stabilization
Status of unit
40 000 ft@-55°C
30 min.
1 000 ft/min to 70 000 ft@-55°C,
30 min.
unit operating
MIL-STD-810G
Method 500.5
Humidity cyclic
Number of cycle
Cycle duration
Relative humidity variation
Temperature variation
Status of unit
10
Cycle I : 24 Hrs
60 % to 88 %
31°C to 41°C
unit not operating
MIL-STD-810G
Method 507.5
Humidity steady
Damp heat
Temperature
Duration
Status of unit
93 % relative humidity
40°C
56 days
unit not operating
MIL-STD-202G
Method 103B
Salt atmosphere
Temperature
Concentration NaCl
Duration
Status of unit
35°C
5 %
48 Hrs
unit not operating
MIL-STD-810G
Method 509.5
Temperature
cycling
Number of cycles
Temperature change
Transfert time
Steady state time
Status of unit
200
-40°C / +85°C
40 min.
20 min.
unit operating
MIL-STD-202A
Method 102A
Temperature
shock
Number of shocks
Temperature change
Transfert time
Steady state time
Status of unit
100
-55°C / +105°C
10 sec.
20 min.
unit not operating
MIL-STD-202G
Method 107G
Mechanical Qualifications
Vibration
(Sinusoidal)
Number of cycles
Frequency / amplitude
Frequency / acceleration
Duration
Status of unit
10 cycles in each axis
10 to 60 Hz / 0,7 mm
60 to 2 000 Hz / 10 g
2h 30 min. per axis
unit not operating
MIL-STD-810G
Method 514.6
Shock
(Half sinus)
Number of shocks
Peak acceleration
Duration
Shock form
Status of unit
3 shocks in each axis
100 g
6 ms
1/2 sinusoidal
unit not operating
MIL-STD-810G
Method 516.6
Bump
(Half sinus)
Number of bumps
Peak acceleration
Duration
Status of unit
2 000 Bumps in each axis
40 g
6 ms
unit not operating
MIL-STD-810G
Method 516.6
For locations, phone, fax, E-Mail see back cover
9
LGDS-100 Series
Gaia Converter FC12-045.02/12 Revision A
©
4
Hi-Rel
Grade
11- Description of Protections
11-1 Output Over Current Protection (OCP)
The LGDS-100 provides a circuit breaker function that latches
the output off if the load current exceeds the current limit
threshold for a duration. The circuit breaker function
automatically attempts to restart power after a load current
fault at a low duty cycle to prevent the LGDS-100 from
overheating. The over current protection function protects
the module against over load of any duration and restores
the module to normal operation when the over load is
removed. It operates in «hiccup» mode by testing
periodically if an overload is applied (typically every 1s
recovery time). The overload detection threshold is typically
19A with a detection time lower than 5ms.
11-2 Inrush Current Limitation
The inrush current limitation function operates by limiting
the output voltage ramp up. It is internally set at 5V/ms
typically. The inrush current is calculated as follow.
I
inrush
=C
out
×
dV
out
dt
where :
Cout is the capacitor value connected to the output
dV
out
dt
= 5V/ms
By adding a capacitor connected across the pins «Drive» &
«Gi», and in order to reduce the inrush current the value
dV
out
dt
can be adjusted as follow :
11-3 Over Temperature Protection (OTP)
A thermal protection device adjusted at 120°C (+/-5%)
internal temperature with a 10°C hysteresis cycle will inhibit
the module as long as the overheat is present and restores
to normal operation automatically when overheat is
removed.
The LGDS-100 includes 3 types of protection devices.
time
recovery time
detection time
recovery time
x
100
Vo (%)
Temperature
On
120˚c
Off
10˚c
COUT
CDRIVE VOUT
LGDS-100
+Vo
Drive
VI
Gi
1
2
3
7
8
9
4
5
C
DRIVE
is given in nF
dV
out
= 50 V/ms
dt 10 + C
DRIVE
For locations, phone, fax, E-Mail see back cover
10
LGDS-100 Series
Gaia Converter FC12-045.02/12 Revision A
©
4
Hi-Rel
Grade
12- Application Notes
12-1 Reverse Polarity Compatibility
The LGDS-100 has been designed to be compliant with reverse polarity requirements. The reverse polarity protection can
be externally achieved either by a standard solution using a schottky diode or either a low losses solution using a N
channel power MOSFET. The following figures are showing both solutions.
LGDS-100
+Vo
Drive
VI
Gi
1
2
3
7
8
9
4
5
12-2 Drive Function
The LGDS-100 features a drive function used to adjust the inrush current limit during start-up phase and to achieve a low
loss reverse polarity protection.
Parameter Unit Min. Typ. Max. Notes, conditions
Drive voltage Vdc Vo-0.6 / Vo+12
Drive current
source
sink
µA
µA
50
-1 000
/
/
100
0 Must be externally limited
LGDS-100
+Vo
Drive
VI
Gi
1
2
3
7
8
9
4
5
12-3 Typical Architecture Schematics Using LGDS-100 with Multiple Modules
The LGDS-100 is compliant for use with several DC/DC GAIA converter modules in various configurations.
To meet MIL-STD-461D/E/F, DO-160D/E/F requirements, GAIA Converter recommends the use of ready-to-use EMI filter
together with it’s R*C* cell (see EMI filter datasheet for details).
For stability purpose GAIA Converter recommends the use of a 220µF/50V capacitor after the LGDS-100.
EMI input filter
FGDS-10A-50V
Go
+Vo
GI
VI
MGDM-series
Go
+Vo
GI
VI
MGDM-series
Go
+Vo
GI
VI
MGDM-series
EMI input filter
FGDS-10A-50V
LGDS-100
Vo
Vo Vi
Gi
1
2
3
7
8
9
5
Vi
Gi Go
GndGnd
220µF/50V
Vi
Gi
Vo
Go
C*
R*
Note : such design with joint EMI filter is incompatible with reverse polarity compatibility. In such case place the second EMI
filter after LGDS-100.
For locations, phone, fax, E-Mail see back cover
11
LGDS-100 Series
Gaia Converter FC12-045.02/12 Revision A
©
4
Hi-Rel
Grade
13- Dimensions
Dimension are given in mm. Tolerance : +/- 0,2 mm unless otherwise indicated.
Weight : 35 grams (1.22 Ozs) max.
16- Connections
Pin LGDS-100
1,2,3 +Input (Vin)
4 Drive
5 Common (Gin)
6 Not connected
7,8,9 Output (Vo)
3
2
1
7
8
9
4 5 6
Bottom view
14- Materials
Case : Metallic black anodized coating.
Pins : Plated with pure matte tin over nickel underplate.
15- Product Marking
Upper face : Company logo, location of manufacturing.
Side face : Module reference, option, date code : year and week of manufacturing.
Information given in this datasheet is believed to be accurate and reliable. However, no responsibility is assumed for the consequence of its use nor for any infringement of patents or other rights of third parties which may result from its use.
These products are sold only according to GAIA Converter general conditions of sale, unless otherwise confirmed by writing. Specifications subject to change without notice.
Printed in France by GAIA Converter Gaia Converter FC12-045.02/12 Revision A. Graphisme : Philippe Clicq
Represented by :
For more detailed specifications and applications information, contact :
International Headquarters
GAÏA Converter - France
ZI de la Morandière
33185 LE HAILLAN - FRANCE
Tel. : + (33)-5-57-92-12-80
Fax : + (33)-5-57-92-12-89
North American Headquarters
GAÏA Converter Canada, Inc
4038 Le Corbusier Blvd
LAVAL, QUEBEC - CANADA H7L 5R2
Tel. : (514)-333-3169
Fax : (514)-333-4519