24/9/2011
FLDM 170G1001/S42
Copy counters
Photoelectric sensors
www.baumer.com
general data
measuring distance Sd 0 ... 72 mm
enlarged measuring range 0 ... 90 mm
optimum operating distance 20 ... 40 mm
counting rate < 1’500’000 copies/h
object speed < 2 m/sec
object cycle distance > 1 mm
sensitivity single sheet/edge thickness 0,1 mm
sync. input yes
measuring point visible red point
light source pulsed red laser diode
wave length 670 nm
laser class 2
edge indicator LED red
power on indication LED green
sensitivity adjustment no
electrical data
voltage supply range +Vs 18 ... 30 VDC
current consumption max. 140 mA
output circuit push-pull
output pulse length 2 / 5 / 10 / 20 ms selectable
short circuit protection yes
reverse polarity protection yes
mechanical data
type rectangular
housing material die-cast zinc
connector base (main connector)
front (optics) glass
ambient conditions
operating temperature 10 ... +40 °C
protection class IP 54
photo
connection diagram
+VS
ground
PTC
125
output
(6)
(3)
(1)
laser spot
70
67 (typ) 45° (typ)
70
laser warning
LASER RADIATION
DO NOT STARE INTO BEAM
Wavelength: 620...680nm
Max. av. Output: < 1mW
IEC 60825-1, Ed. 2, 2007
CLASS 2 LASER PRODUCT
Complies with 21 CFR 1040.10 and 1040.11 except for deviations
pursuant to laser notice No. 50, dated June 24, 2007