https://www.phoenixcontact.com/us/products/2904608 Power supply unit - QUINT4-PS/1AC/12DC/15 - 2904608 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Primary-switched QUINT POWER power supply with free choice of output characteristic curve, SFB (selective fuse breaking) technology, and NFC interface, input: 1-phase, output: 12 V DC/15 A Product Description The fourth generation of the high-performance QUINT POWER power supplies ensures superior system availability by means of new functions. Signaling thresholds and characteristic curves can be individually adjusted via the NFC interface. The unique SFB technology and preventive function monitoring of the QUINT POWER power supply increase the availability of your application. Your advantages Preventive function monitoring indicates critical operating states before errors occur Signaling thresholds and characteristic curves that can be adjusted via NFC maximize system availability Power reserve for easy system extension thanks to static boost with sustained power of up to 125% and ability to start difficult loads thanks to dynamic boost with up to 200% for 5 seconds High degree of immunity, thanks to integrated gas-filled surge arrester and mains failure bridging time of more than 20 milliseconds Robust design thanks to metal housing and wide temperature range from -40C to +70C Worldwide use thanks to the wide range input and international approval package Key Commercial Data Packing unit 1 pc GTIN GTIN 4055626355054 Weight per Piece (excluding packing) 1,100.000 g Custom tariff number 85044030 Country of origin Thailand Technical data Dimensions Width 50 mm 01/23/2019 Page 1 / 8 https://www.phoenixcontact.com/us/products/2904608 Power supply unit - QUINT4-PS/1AC/12DC/15 - 2904608 Technical data Dimensions Height 130 mm Depth 125 mm Width with alternative assembly 122 mm Height with alternative assembly 130 mm Depth with alternative assembly 53 mm Ambient conditions Degree of protection IP20 Ambient temperature (operation) -25 C ... 70 C (> 60 C Derating: 2.5 %/K) Ambient temperature (start-up type tested) -40 C Ambient temperature (storage/transport) -40 C ... 85 C Max. permissible relative humidity (operation) 95 % (at 25 C, non-condensing) Climatic class 3K3 (in acc. with EN 60721) Degree of pollution 2 Installation height 5000 m (> 2000 m, observe derating) Input data Nominal input voltage range 100 V AC ... 240 V AC 110 V DC ... 250 V DC Input voltage range 100 V AC ... 240 V AC -15 % ... +10 % 110 V DC ... 250 V DC -18 % ... +40 % Dielectric strength maximum 300 V AC 60 s AC frequency range 50 Hz ... 60 Hz -10 % ... +10 % Discharge current to PE < 3.5 mA Current consumption 2.4 A (100 V AC) 120 V AC 230 V AC 1.1 A (240 V AC) Nominal power consumption 221 VA Inrush surge current typ. 15 A (at 25 C) Mains buffering typ. 55 ms (120 V AC) typ. 56 ms (230 V AC) Input fuse 8 A (slow-blow, internal) Choice of suitable circuit breakers 10 A ... 16 A (Characteristic B, C, D, K or comparable) Type of protection Transient surge protection Protective circuit/component Varistor, gas-filled surge arrester Output data Nominal output voltage 12 V DC 01/23/2019 Page 2 / 8 https://www.phoenixcontact.com/us/products/2904608 Power supply unit - QUINT4-PS/1AC/12DC/15 - 2904608 Technical data Output data Setting range of the output voltage (USet) 12 V DC ... 15 V DC (constant capacity) Nominal output current (IN) 15 A Static Boost (IStat.Boost) 17.5 A Dynamic Boost (IDyn.Boost) 20 A (5 s) Selective Fuse Breaking (ISFB) 60 A (15 ms) Derating > 60 C (2.5%/K) Connection in parallel Yes, for redundancy and increased capacity Connection in series yes Feedback resistance 25 V DC Control deviation < 0.5 % (Static load change 10 % ... 90 %) < 4 % (Dynamic load change 10 % ... 90 %, (10 Hz)) < 0.25 % (change in input voltage 10 %) Residual ripple < 50 mVPP (with nominal values) Output power 180 W Typical response time 300 ms (from SLEEP MODE) Maximum power dissipation in no-load condition < 4 W (120 V AC) < 4 W (230 V AC) Power loss nominal load max. < 18 W (120 V AC) < 16 W (230 V AC) General Net weight 1.3 kg Efficiency typ. 91.2 % (120 V AC) typ. 92 % (230 V AC) Insulation voltage input/output 4 kV AC (type test) 2 kV AC (routine test) Insulation voltage input / PE 3.5 kV AC (type test) 2.4 kV AC (routine test) Insulation voltage output / PE 0.5 kV DC (type test) 0.5 kV DC (routine test) Protection class I Degree of protection IP20 MTBF (IEC 61709, SN 29500) > 1196000 h (25 C) > 749000 h (40 C) > 355000 h (60 C) Mounting position horizontal DIN rail NS 35, EN 60715 Assembly instructions alignable: PN 50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically 01/23/2019 Page 3 / 8 https://www.phoenixcontact.com/us/products/2904608 Power supply unit - QUINT4-PS/1AC/12DC/15 - 2904608 Technical data General alignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom Connection data, input Connection method Screw connection Conductor cross section solid min. 0.2 mm Conductor cross section solid max. 2.5 mm Conductor cross section flexible min. 0.2 mm Conductor cross section flexible max. 2.5 mm Conductor cross section AWG min. 24 Conductor cross section AWG max. 14 Stripping length 6.5 mm Connection data, output Connection method Screw connection Conductor cross section solid min. 0.2 mm Conductor cross section solid max. 6 mm Conductor cross section flexible min. 0.2 mm Conductor cross section flexible max. 4 mm Conductor cross section AWG min. 24 Conductor cross section AWG max. 14 Stripping length 6.5 mm Connection data for signaling Connection method Push-in connection Conductor cross section solid min. 0.2 mm Conductor cross section solid max. 1.5 mm Conductor cross section flexible min. 0.2 mm Conductor cross section flexible max. 1.5 mm Conductor cross section AWG min. 24 Conductor cross section AWG max. 16 Stripping length 8 mm Standards and Regulations Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU Standard - Safety of transformers EN 61558-2-16 (air clearances and creepage distances only) Standard - Electrical safety IEC 60950-1/VDE 0805 (SELV) Standard - Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV) Standard - Safety extra-low voltage IEC 60950-1 (SELV) 01/23/2019 Page 4 / 8 https://www.phoenixcontact.com/us/products/2904608 Power supply unit - QUINT4-PS/1AC/12DC/15 - 2904608 Technical data Standards and Regulations EN 60204-1 (PELV) Standard - Safe isolation DIN VDE 0100-410 Standard - Limitation of mains harmonic currents EN 61000-3-2 Shipbuilding approval DNV GL, PRS, BV, LR, ABS UL approvals UL Listed UL 508 UL/C-UL Recognized UL 60950-1 UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location) Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27) Vibration (operation) 5 Hz ... 100 Hz resonance search 2.3g, 90 min., resonance frequency 2.3g, 90 min. (according to DNV GL Class C) Approval - requirement of the semiconductor industry with regard to mains SEMI F47-0706; EN 61000-4-11 voltage dips Rail applications EN 50121-3-2 Overvoltage category (EN 60950-1) II ( 5000 m) Overvoltage category (EN 61010-1) II ( 5000 m) Overvoltage category (EN 62477-1) III ( 2000 m) Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 25; For details about hazardous substances go to tab "Downloads", Category "Manufacturer's declaration" Drawings Block diagram ! + + - active PFC N (-) 13 14 OVP "C POut [%] (+) L Diagram 175 # 150 125 " 100 Rem SGnd Out 1 Out 2 75 25 0 POut ! ! = PN 100 % $ 60 C " = PStat. 125 % $ 40 C # = PDyn. 150 % $ 60 C 50 NFC 0 1000 2000 3000 4000 5000 H [m] Classifications eCl@ss eCl@ss 6.0 27049000 eCl@ss 7.0 27049002 01/23/2019 Page 5 / 8 https://www.phoenixcontact.com/us/products/2904608 Power supply unit - QUINT4-PS/1AC/12DC/15 - 2904608 Classifications eCl@ss eCl@ss 8.0 27049002 eCl@ss 9.0 27040701 ETIM ETIM 5.0 EC002540 ETIM 6.0 EC002540 Approvals Approvals Approvals UL Listed / UL Recognized / cUL Recognized / cUL Listed / cULus Recognized / cULus Listed Ex Approvals UL Listed / cUL Listed / cULus Listed Approval details UL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 123528 UL Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 211944 cUL Recognized http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 211944 cUL Listed http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 123528 01/23/2019 Page 6 / 8 https://www.phoenixcontact.com/us/products/2904608 Power supply unit - QUINT4-PS/1AC/12DC/15 - 2904608 Approvals cULus Recognized cULus Listed Accessories Accessories Assembly adapter Assembly adapters - UWA 182/52 - 2938235 Universal wall adapter for securely mounting the power supply in the event of strong vibrations. The power supply is screwed directly onto the mounting surface. The universal wall adapter is attached at the top/bottom. Assembly adapters - UWA 130 - 2901664 2-piece universal wall adapter for securely mounting the power supply in the event of strong vibrations. The profiles that are screwed onto the side of the power supply are screwed directly onto the mounting surface. The universal wall adapter is attached on the left/right. Assembly adapters - QUINT-PS-ADAPTERS7/1 - 2938196 Assembly adapter for QUINT-PS... power supply on S7-300 rail Device protection 01/23/2019 Page 7 / 8 https://www.phoenixcontact.com/us/products/2904608 Power supply unit - QUINT4-PS/1AC/12DC/15 - 2904608 Accessories Type 3 surge protection device - PLT-SEC-T3-230-FM-UT - 2907919 Type 2/3 surge protection, consisting of protective plug and base element, with integrated status indicator and remote signaling for single-phase power supply networks. Nominal voltage 230 V AC/DC. Type 3 surge protection device - PLT-SEC-T3-24-FM-UT - 2907916 Type 3 surge protection, consisting of protective plug and base element, with integrated status indicator and remote signaling for single-phase power supply networks. Nominal voltage 24 V AC/DC. Programming adapter Programming adapter - TWN4 MIFARE NFC USB ADAPTER - 2909681 Near Field Communication (NFC) programming adapter with USB interface for the wireless configuration of NFC-capable products from PHOENIX CONTACT with software. No separate USB driver is required. Phoenix Contact 2019 (c) - all rights reserved http://www.phoenixcontact.com 01/23/2019 Page 8 / 8