BAS116UDJ ADVANCE INFORMATION DUAL SURFACE MOUNT SWITCHING DIODE Features Mechanical Data * * * * * * * * * Ultra-Small Surface Mount Package (1.0 x 0.8mm) Ultra-Low Profile Package (0.45mm) Ultra Low Leakage Current (5nA @ VR = 75V) Low Capacitance Ideal for Battery Powered Portable Applications Lead Free By Design/RoHS Compliant (Note 1) Halogen and Antimony Free "Green" Device (Notes 2 & 3) * * * * Case: SOT963 Case Material: Molded Plastic, "Green" Molding Compound. UL Flammability Classification Rating 94V-0 Moisture Sensitivity: Level 1 per J-STD-020 Terminal Connections: See Diagram Terminals: Finish - Matte Tin Annealed over Copper leadframe. Solderable per MIL-STD-202, Method 208 Weight: 0.003 grams (Approximate) SOT963 K1 NC D1 A1 Top View A2 D2 NC K2 Internal Schematic Ordering Information (Note 4) Part Number BAS116UDJ-7 Notes: Case SOT963 Packaging 10,000/Tape & Reel 1. Fully EU Directive 2002/95/EC (RoHS) & 2011/65/EU (RoHS 2) compliant. No purposely added lead. 2. Halogen and Antimony free "Green" products are defined as those which contain <900ppm bromine, <900ppm chlorine (<1500ppm total Br + Cl) and <1000ppm antimony compounds. 3. Diodes Inc.'s "Green" policy can be found on our website at http://www.diodes.com. 4. For packaging details, go to our website at http://www.diodes.com. Marking Information 7K BAS116UDJ Document number: DS35244 Rev. 3 - 2 7K = Product Type Marking Code 1 of 4 www.diodes.com April 2012 (c) Diodes Incorporated BAS116UDJ Maximum Ratings @TA = 25C unless otherwise specified ADVANCE INFORMATION Characteristic Peak Repetitive Reverse Voltage Working Peak Reverse Voltage DC Blocking Voltage RMS Reverse Voltage Forward Continuous Current (Note 5) Repetitive Peak Forward Current Non-Repetitive Peak Forward Surge Current Symbol VRRM VRWM VR VR(RMS) IFM IFRM @ t = 1.0s @ t = 1.0ms @ t = 1.0s IFSM Value Unit 85 V 60 215 500 4.0 1.0 0.5 V mA mA A Thermal Characteristics Characteristic Power Dissipation (Note 5) Thermal Resistance Junction to Ambient Air (Note 5) Operating and Storage Temperature Range Electrical Characteristics Characteristic Reverse Breakdown Voltage (Note 6) Symbol PD RJA TJ, TSTG Value 250 500 -55 to +150 @TA = 25C unless otherwise specified Symbol V(BR)R Min 85 Typ Max Unit V 0.95 1.05 1.15 1.35 V Forward Voltage VF Leakage Current (Note 6) IR 5.0 500 Total Capacitance CT 0.9 16 2 nA nA pF Reverse Recovery Time trr 0.12 3.0 s Notes: Unit mW C/W C Test Condition IR = 100A IF = 1.0mA IF = 10mA IF = 50mA IF = 150mA VR = 75V VR = 75V, TJ = 150C VR = 0, f = 1.0MHz IF = IR = 10mA, Irr = 0.1 x IR, RL = 100 5. Part mounted on FR-4 PC board with recommended pad layout, which can be found on our website at http://www.diodes.com. 6. Short duration pulse test used to minimize self-heating effect. BAS116UDJ Document number: DS35244 Rev. 3 - 2 2 of 4 www.diodes.com April 2012 (c) Diodes Incorporated BAS116UDJ IF, INSTANTANEOUS FORWARD CURRENT (mA) PD, POWER DISSIPATION (mW) 250 200 Note 5 150 100 50 0 0 1,000 100 T A = 150C 10 T A = 125C 1 TA = 85C TA = 25C 0.1 T A = -55C 0.01 0.001 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 VF, INSTANTANEOUS FORWARD VOLTAGE (V) Fig. 2 Typical Forward Characteristics - Per Element 25 50 150 75 100 125 TA, AMBIENT TEMPERATURE (C) Fig. 1 Power Dissipation vs. Ambient Temperature 100 2.00 1.75 10 CT, TOTAL CAPACITANCE (pF) IR, INSTANTANEOUS REVERSE CURRENT (nA) ADVANCE INFORMATION 300 T A = 150C T A = 125C 1 TA = -55C TA = 25C TA = 85C 0.1 f = 1MHz 1.50 1.25 1.00 0.75 0.50 0.25 0 0.01 0 10 20 30 40 50 60 70 80 90 100 VR, INSTANTANEOUS REVERSE VOLTAGE (V) Fig. 3 Typical Reverse Characteristics - Per Element 0 5 10 15 20 25 30 35 40 VR, DC REVERSE VOLTAGE (V) Fig. 4 Typical Total Capacitance vs. Reverse Voltage Per Element Package Outline Dimensions D e1 L E E1 e b (6 places) c A SOT963 Dim Min Max Typ A 0.40 0.50 0.45 A1 0 0.05 c 0.120 0.180 0.150 D 0.95 1.05 1.00 E 0.95 1.05 1.00 E1 0.75 0.85 0.80 L 0.05 0.15 0.10 b 0.10 0.20 0.15 e 0.35 Typ e1 0.70 Typ All Dimensions in mm A1 BAS116UDJ Document number: DS35244 Rev. 3 - 2 3 of 4 www.diodes.com April 2012 (c) Diodes Incorporated BAS116UDJ Suggested Pad Layout ADVANCE INFORMATION C C Dimensions Value (in mm) C 0.350 X 0.200 Y 0.200 Y1 1.100 Y1 Y (6X) X (6X) IMPORTANT NOTICE DIODES INCORPORATED MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARDS TO THIS DOCUMENT, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION). Diodes Incorporated and its subsidiaries reserve the right to make modifications, enhancements, improvements, corrections or other changes without further notice to this document and any product described herein. Diodes Incorporated does not assume any liability arising out of the application or use of this document or any product described herein; neither does Diodes Incorporated convey any license under its patent or trademark rights, nor the rights of others. Any Customer or user of this document or products described herein in such applications shall assume all risks of such use and will agree to hold Diodes Incorporated and all the companies whose products are represented on Diodes Incorporated website, harmless against all damages. Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthorized sales channel. Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized application. Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more United States, international or foreign trademarks. LIFE SUPPORT Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in significant injury to the user. B. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or to affect its safety or effectiveness. Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of Diodes Incorporated products in such safety-critical, life support devices or systems, notwithstanding any devices- or systems-related information or support that may be provided by Diodes Incorporated. Further, Customers must fully indemnify Diodes Incorporated and its representatives against any damages arising out of the use of Diodes Incorporated products in such safety-critical, life support devices or systems. Copyright (c) 2012, Diodes Incorporated www.diodes.com BAS116UDJ Document number: DS35244 Rev. 3 - 2 4 of 4 www.diodes.com April 2012 (c) Diodes Incorporated