www.tracopower.com Page 1 of 4
DC/DC Converters
TEQ 100WIR Series, 100 Watt
Features
High power block with excellent
thermal convection
Operating temperature -40°C to +85°C
without derating
Increased shock & vibration resistance
Ultra wide 4:1 input voltage range
EN 50155 approval for railway applications
Excellent efficiency up to 90%
Input filter meet EN 55032, class A
I/O isolation 2250 VDC
Under voltage lock-out circuit
Soft start
Input protection filter
Order code* Input voltage Output voltage Output current max. Efficiency typ.
TEQ 100-2412WIR 12 VDC (9.6 – 13.2) 8.4 A 90 %
TEQ 100-2415WIR 10 – 36 VDC 24 VDC (19.2 – 26.4) 4.2 A 90 %
TEQ 100-2416WIR (24 VDC nominal) 28 VDC (22.4 – 30.8) 3.6 A 90 %
TEQ 100-2418WIR 48 VDC (38.4 – 52.8) 2.1 A 90 %
TEQ 100-4812WIR 12 VDC (9.6 – 13.2) 8.4 A 90 %
TEQ 100-4815WIR 19 – 75 VDC 24 VDC (19.2 – 26.4) 4.2 A 90 %
TEQ 100-4816WIR (48 VDC nominal) 28 VDC (22.4 – 30.8) 3.6 A 90 %
TEQ 100-4818WIR 48 VDC (38.4 – 52.8) 2.1 A 90 %
TEQ 100-7212WIR 12 VDC (9.6 – 13.2) 8.4 A 89 %
TEQ 100-7215WIR 43 – 160 VDC 24 VDC (19.2 – 26.4) 4.2 A 90 %
TEQ 100-7216WIR (110 VDC nominal) 28 VDC (22.4 – 30.8) 3.6 A 90 %
TEQ 100-7218WIR 48 VDC (38.4 – 52.8) 2.1 A 90 %
Models
The TEQ-100WIR Series is a family of isolated high performance
dc-dc converter modules with ultra-wide 4:1 input voltage ranges
which come in a rugged, sealed metal case.
These converters are suitable for a wide range of applications,
but the product is designed particularly also for industrial appli-
cations where often no PCB mounting is possible but the module
has to be mounted on a chassis. A very high efficiency and the
overall heatsink construction allows an operating temperature
up to +85°C with natural convection cooling without power derating
and up to +95ºC with power derating. Further features include output
voltage trimming, Remote On/Off and under voltage lockout. The
ultra wide input voltage range and reverse input voltage protection
make these converters also an interesting solution for battery operated
systems.
UL 60950-1
C B
Scheme
UL 508
www.tracopower.com Page 2 of 4
Input Specifications
Input current at no load 24 Vin models: 25 mA typ.
48 Vin models: 20 mA typ.
110 Vin models: 10 mA typ.
Start-up voltage 24 Vin models: 10.0 VDC (or lower)
48 Vin models: 19.0 VDC (or lower)
110 Vin models: 43.0 VDC (or lower)
Under voltage shut down (lock-out circuit) 24 Vin models: 8.0 VDC (or lower)
48 Vin models: 17.0 VDC (or lower)
110 Vin models: 37.5 VDC (or lower)
Surge voltage (1 sec. max.) 24 Vin models: 50 V max.
48 Vin models: 100 V max.
110 Vin models: 185 V max.
Conducted noise EN 55032 class A
EMC immunity EN 50121-3-2
ESD (electrostatic discharge) EN 61000-4-2, air ±8 kV, contact ±6 kV,
perf. criteria A
Radiated immunity EN 61000-4-3, 20 V/m, perf. criteria A
– Fast transient / surge EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±1 kV, perf. criteria A
EN 61000-4-5, ±2 kV, perf. criteria A
Conducted immunity EN 61000-4-6, 10 Vrms, perf. criteria A
Railway immunity EN 50155
Reverse voltage protection parallel diode
Output Specifications
Voltage set accuracy ±1 %
Output voltage adjustment +10 % / –20 %
Regulation – Input variation Vin min. to Vin max. 0.1 % max.
– Load variation (0 – 100 %) 0.1 % max.
Temperature coefficient ±0.02 %/K
Minimum load not required
Remote sense up to Vout nom. +10%
Ripple and noise (20 MHz Bandwidth) 12 VDC models: 125 mVp-p max.
24 & 28 VDC models: 250 mVp-p max.
48 VDC models: 350 mVp-p max.
DC/DC Converters
TEQ 100WIR Series 100 Watt
www.tracopower.com Page 3 of 4
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Output Specifications (continued)
Start up time (nominal Vin and constant resistive load) 75 ms typ. (at power On or remote On)
Transient response (25% load step change) 250 µs max.
Output current limitation at 120 -150 % of Iout max.
Over voltage protection at 115 -130 % of Vout nom.
Short circuit protection hiccup, automatic recovery
Capacitive load 12 VDC models: 7‘000 µF max.
24 VDC models: 1‘750 µF max.
28 VDC models: 1‘280 µF max.
48 VDC models: 430 µF max.
General Specifications
Temperature ranges – Operating –40°C to +105°C (up to +85°C w/o derating)
– Storage –40°C to +105°C
Thermal impedance 1.45°C/W
Derating See derating graph below
Over temperature protection at 110°C typ.
Thermal shock acc. MIL-STD-810F
Shock & Vibration acc. EN61373, MIL-STD-810F
Humidity (non condensing) 5 % to 95 % rel H max.
Reliability, calculated MTBF (MIL-HDBK-217F, at +25°C, ground benign) > 711‘000 h
Isolation voltage (60sec.) – Input/Output 2’250 VDC (basic insulation)
– Input/Case 1’600 VDC
Isolation resistance – Input/Output (500 VDC) >1 GOhm min.
Switching frequency 24 & 48 Vin models: 250 kHz typ. (puls width modulation)
110 Vin models: 300 kHz typ. (puls width modulation)
Safety standards – CB test certificate IEC/EN 60950-1 (ed. 2), EN 60950-1:2006/
A11:2009/A1:2010/A12:2011/A2:2013
– CSA certificate of compliance UL 508, CSA C22.2 No. 107.1-01
– UL online certification E188913, QQGQ2 UL 60950-1 2nd ed. +Am1
– Railway immunity EN50155
Certification documents www.tracopower.com/overview/teq100wir
Remote On/Off – positive logic (standard) – On: 3 to 12 VDC or open circuit
– Off: 0 to 1.2 VDC
or short circuit terminal 1 and 4
– negative logic (option -N) – On: 0 to 1.2 VDC
or short circuit terminal 1 and 4
Off: 3 to 12 VDC or open circuit
– Off idle current: 3 mA
Environmental compliance – Reach document
www.tracopower.com/info/reach-declaration.pdf
– RoHS RoHS directive 2011/65/EU
– Flammability identified acc. EN 45545-2
www.tracopower.com/info/en45545-declaration.pdf
DC/DC Converters
TEQ 100WIR Series 100 Watt
0
20
40
60
80
100
120
-40 -20 0 20 40 60 80 100 120
A
MBIENT TEMPERATURE,TA(ºC)
OUTPUT POWER(%
)
Natural convection (20LFM)
Temperature derating
www.tracopower.com
Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com
www.tracopower.com
Page 4 of 4
DC/DC Converters
TEQ 100WIR Series 100 Watt
TEQ 100WIR module:
* Sense line to be connected to the output either at the module or at the load under regard of polarity.
– The current rating of the terminal block is 15 A/pole.
– Using 2 poles in parallel if the peak output current can exceed 15 A.
– Wire size shall be selected to withstand the peak output current (Iout max + Current limitation).
Physical Specifications
Casing material aluminium
Potting material silicone (UL94V-0 rated)
Weight 800 g (28.22oz)
Dimensions
Rev. December 4, 2018
103.2 (4.06)
74.2 (2.92)
79.1 (3.11)
3.2 (0.13)
88.9 (3.50)
76.2 (3.0)
87.6 (3.45)
Connection
Terminal Pin Function Recommended wire
1,2
– Vin 12 AWG
3
NC NA
4
Ctrl (Remote On/Off) 14 – 18 AWG
5,6
+ Vin 12 AWG
7,8
– Vout 12 AWG
9
– Sense* 14 – 18 AWG
10
+ Sense* 14 – 18 AWG
11,12
+ Vout 12 AWG
45.0 (1.77) 8.7 (0.34)
50.0 (1.97)
DIN-Rail clip: Order code: TEQ-MK1
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
TRACO Power:
TEQ 100-7215WIR TEQ 100-2416WIR TEQ 100-2415WIR TEQ 100-7212WIR TEQ 100-7218WIR TEQ 100-
2412WIR TEQ 100-4818WIR TEQ 100-4816WIR TEQ 100-4812WIR TEQ 100-4815WIR TEQ 100-2418WIR TEQ
100-7216WIR TEQ-MK1