SERIES 1536 Miniature Protection Ambient-Temperature Compensated Performance Data 3-Pole High Performance Three-Phase Protection: Features common trip mechanism which simultaneously trips all three phases regardless of which phase is overloaded Integral Barriers: Terminals are separated by barriers molded into the case Single-Hole Mounting: For quick, easy installation Shock And Vibration Resistant Construction: Permits use in portable, mobile, and all types of airborne equipment The 1536-001 is a lightweight, miniature breaker that features three bimetal sensing elements having very fast electro-dynamic response under short circuit conditions, and standard trip characteristics at lower levels of overloads. A common trip mechanism assures simultaneous trip of all three phases, regardless of which phase is overloaded. Single hole mounting and small size facilitate easy installation. The breaker's one-piece, glass-filled case features integrally-molded barriers to separate the terminals. Interrupting Capacity: 1,000 amps at 205V, 400 Hz., 3 phase symmetrical fault. 1,000 amps at 120V, 400 Hz., single phase fault Endurance: At 120VAC, 400 Hz.: inductive load--5,000 cycles; resistive load--5,000 cycles; mechanical cycling, no load--5,000 cycles Overload Cycling: 100 operations at 200% load Dielectric Strength: 1,500V, minimum Insulation Resistance: Not less than 100 megohms at 500V, DC Voltage Drop: Varies with rating. (see "Ordering Information") Vibration: Exceeds MIL. STD. 202, Method 204, Condition A Shock: Exceeds 30 g's, 11 Millisec (half-sine pulse) MIL STD. 202, Method 213 Test J Acceleration: Exceeds 10 g's Weight: 130 grams (.29 lbs.) Overload Calibration Data Specification @ 25C @ +71C @ -54C Test Time Table Parameters MIN MAX MIN MAX MIN Must Hold 105 -- 70 -- 130 -- % For 1 Hour Must Trip -- -- 110 -- 160 % Within 1 Hour 200% Overload 10.00 70.0 -- -- -- -- Seconds 400% Overload 2.00 10.0 -- -- -- -- Seconds 600% Overload 1.00 4.0 -- -- -- -- Seconds 1000% Overload 0.35 1.4 *Unbalanced load, individual phases: 145% Trip curve available - consult factory -- -- -- -- Seconds 138 Balanced* MAX. Dimensions Ordering Information Mechanical Products, Inc. 1824 River Street P.O. Box 729 Jackson, MI 49204 (517) 782-0391 FAX (517) 782-2810 Ampere Rating Voltage Drop Max.* Part Number 5 0.350 1536-001-5 7 1/2 0.325 1536-001-705 10 0.300 1536-001-10 15 0.250 1536-001-15 20 0.200 1536-001-20 25 0.180 1536-001-25 30 1.180 1536-001-30 35 0.175 1536-001-35 40 0.175 1536-001-40 50 0.150 1536-001-50 *At rated nominal current. For other amp ratings, consult factory. (c)Copyright 1995, Mechanical Products, Inc. All Rights Reserved. SERIES 1536 Miniature Protection Ambient-Temperature Compensated PERCENTAGE OF CURCUIT BREAKER'S RATED CURRENT The 1536-001 is a lightweight, circuit breaker that features three bimetal sensing elements having very fast electro-dynamic response under short circuit conditions, and standard trip characteristics at lower levels of overloads. A common trip mechanism assures simultaneous trip of all three phases, regardless of which phase is overloaded. TIME TO OPEN (TRIP) IN SECONDS Overload Calibration Data Specification @ 25C @ +71C @ -54C Test Time Table Parameters MIN MAX MIN MAX MIN Must Hold 105 -- 70 -- 130 MAX -- % For 1 Hour Must Trip -- 138 -- 110 -- 160 % Within 1 Hour 200% Overload 10.00 70.0 -- -- -- -- Seconds 400% Overload 2.00 10.0 -- -- -- -- Seconds 600% Overload 1.00 4.0 -- -- -- -- Seconds 1000% Overload 0.35 1.4 -- -- -- -- Seconds Mechanical Products, Inc. 1824 River Street, P.O. Box 729, Jackson, MI 49204 (517) 782-0391, FAX (517) 782-2810 SERIES 1536 Dimensions Mechanical Products, Inc. 1824 River Street, P.O. Box 729, Jackson, MI 49204 (517) 782-0391, FAX (517) 782-2810 (c)Copyright 1995, Mechanical Products, Inc. All Rights Reserved.