• DC voltages
Ranges
0.5 - 5 - 50 - 500 0.5 - 5 - 50 - 500 0.5 - 5 - 50 - 500 40 - 400 mV 20 - 200 mV
1,000 V 1,000 V 1000 V
4 - 40 - 400 - 600 V 2 - 20 - 200 - 600 V
Resolution
0.1 mV to 1 V 0.1 mV to 1 V 0.1 mV to 1 V 0.01 mV to 1 V 0.01 mV to 1 V
Basic accuracy*
0.3% rdg + 2 digits 0.3% rdg + 2 digits 0.3% rdg + 2 digits 0.3% rdg + 2 digits 1% rdg + 4 digits
1.5 MΩ(40 mV)
Input impedance
10 MΩ(11 MΩ/ 5V) 10 MΩ(11 MΩ/ 5V) 10 MΩ(11 MΩ/ 5V) 40 MΩ(400 mV)
5 M
Ω
8 MΩ
Protection
±1,100 V
PEAK
±1,100 V
PEAK
±1,100 V
PEAK
600 V
RMS
600 V
RMS
775 V
RMS
(600 V
RMS
/0.5 V) (600 V
RMS
/0.5 V)
• AC voltages Peak factor
633
--
Ranges
0.5 - 5 - 50 0.5 - 5 - 50 0.5 - 5 - 50 40 - 400 mV 200 mV
500 - 750 V 500 - 750 V 500 - 750 V 4 - 400 - 600 V 2 - 20 - 200 - 600 V
Resolution
0.1 mV to 1 V 0.1 mV to 1 V 0.1 mV to 1 V 0.1 mV to 1 V 0.1 mV to 1 V
40 Hz to 500 Hz 40 Hz to 500 Hz
Bandwidth
40 Hz to 100 kHz 40 Hz to 1 kHz 40 Hz to 1 kHz
(100 Hz for 40 mV) (100 Hz for 200 mV)
Basic accuracy*
1% rdg + 3 digits 1.5% rdg + 2 digits 1.5% rdg + 2 digits 1% rdg + 4 digits 1.5% rdg + 8 digits
1.5 MΩ(40 mV) 3 MΩ(200 mV)
Input impedance
10 MΩ(11 MΩ/ 5V) 10 MΩ(11 MΩ/ 5V) 10 MΩ(11 MΩ/ 5V) 40 MΩ(400 mV) 5 MΩ
8 MΩ
Protection
±1,100 VPEAK ±1,100 VPEAK ±1,100 VPEAK 600 VRMS 600 VRMS
775 Vrms (600 Vrms/0.5 V) (600 Vrms/0.5 V)
• AC voltages (low Z) Ranges
5 - 50 - 500 - 750 V 5 - 50 - 500 - 600 V 5 - 50 - 500 - 600 V
--
Resolution
1 mV to 1 V 1 mV to 1 V 1 mV to 1 V
--
Basic accuracy*
1% rdg + 3 digits 1% rdg + 2 digits 1% rdg + 2 digits
--
Input impedance
500 kΩ500 kΩ500 kΩ
--
Protection
±1,100 V
PEAK
775 V
RMS
600 V
RMS
600 V
RMS
--
• DC currents Range
500 mA / 10 A 500 mA / 10 A
-
400 µA, 4 - 40 - 400 mA, 4 - 10 A
-
Resolution
100 µA / 10 mA 100 µA / 10 mA
-
0.1 µA à 10 mA
-
Basic accuracy*
0.3% rdg + 2 digits 0.3% rdg + 2 digits
/ 1% rdg + 2 digits / 1% rdg + 5 digits
-
1% rdg + 3 digits
-
Protection
600 VRMS – HBP fuse 600 VRMS – HBP fuse
-
600 V
RMS
– HBP fuse
-
• AC currents Peak factor
63-
--
Range
500 mA / 10 A (AC+DC)500 mA / 10 A (AC+DC)-
400 µA, 4 - 40 - 400 mA, 200 A
4 - 10 A
(with AM 89N clamp)
Resolution
100 µA / 10 mA 100 µA / 10 mA - 0.1 µA to 10 mA 0.1 A
Bandwidth
40 Hz to 30 kHz /
40 Hz to 10 kHz 40 Hz to 1 kHz - 40 Hz to 500 Hz 40 Hz to 500 Hz
Basic accuracy*
1.5% rdg + 2 digits 1,5% rdg + 2 digits
-1.2% rdg + 5 digits 1% rdg + 4 digits
/ 2.5 % rdg + 2 digits / 2.5 % rdg + 5 digits
(2% with the AM 89N clamp)
Protection
600 VRMS – HBP fuse 600 VRMS – HBP fuse - 600 VRMS – HBP fuse 600 VRMS
• Resistances
Ranges
500 Ω, 5 - 50 - 500 kΩ,500 Ω, 5 - 50 - 500 kΩ,500Ω, 5 - 50 - 500 kΩ,400 Ω, 4 - 40 - 400 kΩ,200 Ω, 2 - 20 - 200 kΩ,
5 - 50 MΩ5 - 50 MΩ5 - 50 MΩ4 - 40 MΩ2 - 20 MΩ
Resolution
100 mΩto 10 kΩ100 mΩto 10 kΩ100 mΩto 10 kΩ100 mΩto 10 kΩ100 mΩto 10 kΩ
Basic accuracy*
0.3% rdg + 3 digits 0.3% rdg + 3 digits 0.3% rdg + 3 digits 0.5% rdg + 4 digits 1% rdg + 4 digits
Protection
600 V
RMS
600 V
RMS
600 V
RMS
600 V
RMS
600 V
RMS
• Continuity Detection threshold
10 to 15 Ω10 to 20 Ω10 to 20 Ω< 40 Ω•)) 750 Ω•))
• Diode test Diode voltage
0 to 1.999 V 0 to 1.999 V 0 to 1.999 V 0 to 4 V 0 to 3 V
• Capacity
Ranges
50 - 500 nF, 5 - 50 50 - 500 nF, 5 - 50 50 - 500 nF, 5 - 50
500 µF, 5 - 50 mF 500 µF, 5 - 50 mF 500 µF, 5 - 50 mF
--
Basic accuracy*
1% rdg + 2 digits 1% rdg + 2 digits 1% rdg + 2 digits
--
• Frequency
Ranges
5 - 50 - 500 Hz, 5 - 50 - 500 Hz, 5 - 50 - 500 Hz, 4 - 40 - 400 kHz,
5 - 50 - 500 kHz** 5 - 50 - 500 kHz** 5 - 50 - 500 kHz** 4 - 40 MHz**
-
Basic accuracy*
0.03%
rdg
+ 1
digits
0.03%
rdg
+ 1
digits
0.03%
rdg
+ 1
digits
0.1%
rdg
+ 3
digits
-
TECHNICAL CHARACTERISTICS MX 26 MX 24B MX 23 MX 22 MX 21
* Accuracy of the best range
** Measurement on 50,000 counts