Cornell Dubilier 140 Technology Place Liberty, SC 29657 Phone: (864)843-2277 Fax: (864)843-3800 www.cde.com
Wet Tantalum - CLR 79 (MIL-C-39006/22)
CLR 81 (MIL-C-39006/25)
Operating Temperature: -55°C to +125°C, with voltage derating above 85°C,
(Max voltage at 125ºC is 2/3 of the value at 85ºC)
Working Voltage: 6 to 125 WVdc
Tolerance: ±10%, ±20%, ±5%
Capacitance: 1.7 to 2200 µF
Key Features
Three volts reverse voltage capability
High ripple current capability
Tantalum case
Hermetically sealed
Low ESR, Low DCL
Extended range on TAX (M39006/25)
Standard high vibration and shock requirements on MIL type
Applications
Filtering, bypass, coupling, energy storage
Low source impedance circuits
High charging current circuits
Outline Dimensions
Military Types CLR79 and CLR81 and CDE’s commercial
equivalent TAT and TAX, all with Teflon inner-seal, glass-to-
metal hermetic outer-seal, tantalum case construction, have higher
ripple current capability and are more reliable than silver case
units with their risk of short circuit failure from silver whiskers.
The tantalum case with its sintered and anodized cathode
connection affords a 3 V reverse voltage capability, and dc leakage
current as little as 2 µA at 125º C.
Commercial Types TAT for CLR79 and TAX for CLR81
General Specifications
Cornell Dubilier 140 Technology Place Liberty, SC 29657 Phone: (864)843-2277 Fax: (864)843-3800 www.cde.com
Wet Tantalum - CLR 79 (MIL-C-39006/22)
CLR 81 (MIL-C-39006/25)
Dimensions
Uninsulated Uninsulated Insulated Insulated E
D L D L C A Lead Length Typi cal
Weight
+ .031, -.016
(+. 79, -. 41)
1 T1 .201(5.10) .475(12.06) . 232(5.89) .640(16.26) .756(19. 20) .025 (. 64) 1.50(38. 10) 2
2 T2 . 289(7. 34) .632(16. 05) . 314(7. 98) .800(20. 32) .913(23. 19) .025 (. 64) 2.25 (57. 15) 5
3 T3 . 387(9. 83) .747(18. 97) .418(10. 62) .900(22. 86) 1.028(26. 11) .025 (. 64) 2.25 (57. 15) 8
4 T4 . 387(9. 83) 1. 047(26.59) .418(10. 62) 1.200(30. 48) 1.328(33. 73) .025 (. 64) 2.25 (57. 15) 15
Inc hes (m m )
C A SE ± . 016(.41)CDE Size ±.250(±.6.35) (grams)M aximu m M axi mu m M axi mu m L ead d i a.(N o m)
Part Markings
Part Number Nomenclature and Ordering
(Commercial Parts)
TAT 106 M 025 1 2
(1) (2) (3) (4) (5) (6)
(1) Series: TAT (M39006/22), TAX (M39006/25)
(2) Cap code: Expressed in Picofarads (1st two digits significant figures, 3rd digit number of zeros.)
(3) Tolerance: M = ±20%, K= ±10%, J= ±5%
(4) Voltage
(5) Sleeve: 0= No sleeve, 1= Polyester, 2= Polyimide
(6) Case code: 1= T1, 2=T2, 3=T3, 4=T4
(MIL Spec Parts)
Indicate the prefix M39006/22 followed by the appropriate MIL dash number. An example for a M39006/22 in a 100 µF,
±20% tolerance, 30 volts, M level, order as a M39006/22H0113.
Note: Parts without sleeves will not meet the MIL requirements for marking permanency (resistance to solvents).
TAT ±20%
20 µF
125Vdc
00853 Cage Number
0335875
Lot Code
COMMERCIAL PARTS
+ Indicates polarity
Voltage
Capacitance
Series/Cap tol
Date Code by year week,
M39006 Series
22HXXXX
J 000853
100 µF Capacitance
30 Vdc Voltage
0335 Date Code
875 Lot Code
MIL PARTS
(Expressed by yearweek)
+ Indicates polarity
Jan/Cage Number
Dash Number
Cornell Dubilier 140 Technology Place Liberty, SC 29657 Phone: (864)843-2277 Fax: (864)843-3800 www.cde.com
Wet Tantalum - CLR 79 (MIL-C-39006/22)
CLR 81 (MIL-C-39006/25)
Ratings
TAT(CLR79)
+25° C
+85°C
&
+125°C -55°C +8C +12C M (1.0) P (0.1) R (0.01)
T AT 306M 00611 30 20 1 9 3. 98 1 2 820 -40 +10. 5 +12 0001 0221 0441
T AT 306K 006 11 30 10 1 9 3. 98 1 2 820 -40 +1 0. 5 +12 0002 0222 0442
TAT 306J 00611 30 5 1 9 3. 98 1 2 820 -40 +10.5 +12 0003 0223 0443
T AT 686M 00611 68 20 1 15 3. 16 1 2 960 -40 +14 +16 0004 02 24 0444
T AT 686K 006 11 68 10 1 15 3. 16 1 2 960 - 40 +14 +16 0005 0225 044 5
T AT 686J 00611 68 5 1 15 3. 16 1 2 960 -40 +14 +16 0006 0226 044 6
T AT 147M 00612 14 0 20 2 21 1. 99 1 3 1200 -40 +14 +16 0007 0227 0447
T AT 147K 006 12 140 10 2 21 1.99 1 3 1200 - 40 +14 +16 0008 0228 044 8
T AT 147J 00612 14 0 5 2 21 1.99 1 3 1200 -40 +14 +16 0009 02 29 0449
T AT 277M 00612 27 0 20 2 45 2. 21 1 6. 5 1375 -44 +17. 5 +20 0010 02 30 0450
T AT 277K 006 12 270 10 2 45 2.21 1 6. 5 1375 -44 +17. 5 +20 0011 0231 0451
T AT 277J 00612 27 0 5 2 45 2.21 1 6. 5 1375 -44 +17. 5 +20 0012 0232 0452
T AT 337M 00613 33 0 20 3 36 1. 45 2 7. 9 1800 -44 +14 +16 0013 02 33 0453
T AT 337K 006 13 330 10 3 36 1.45 2 7. 9 1800 -44 +14 +16 0014 0234 0454
T AT 337J 00613 33 0 5 3 36 1.45 2 7. 9 1800 -44 +14 +16 0015 0235 0455
T AT 567M 00613 56 0 20 3 55 1. 30 2 13 1900 -64 +17. 5 +20 0016 02 36 0456
T AT 567K 006 13 560 10 3 55 1.30 2 13 1900 -64 +17. 5 +20 0017 0237 0457
T AT 567J 00613 56 0 5 3 55 1.30 2 13 1900 -64 +17. 5 +20 0018 0238 0458
T AT 128M 00614 1200 20 4 90 1. 00 3 14 2265 -80 +25 +25 0019 0239 045 9
T AT 128K 006 14 1200 10 4 90 1. 00 3 14 2265 -80 +25 +25 0020 0240 0460
T AT 256M 00811 25 20 1 7. 5 3. 98 1 2 820 -40 +10. 5 +12 0021 0241 046 1
T AT 256K 008 11 25 10 1 7. 5 3. 98 1 2 820 -40 +10. 5 +12 0022 0242 0462
TAT 256J 00811 25 5 1 7.5 3. 98 1 2 820 -40 +10. 5 +12 0023 0243 0463
T AT 566M 00811 56 20 1 14 3. 32 1 2 900 -40 +14 +16 0024 02 44 0464
T AT 566K 008 11 56 10 1 14 3. 32 1 2 900 - 40 +14 +16 0025 0245 046 5
T AT 566J 00811 56 5 1 14 3. 32 1 2 900 -40 +14 +16 0026 02 46 0466
T AT 127M 00812 12 0 20 2 20 2. 21 1 2 1220 -44 +17. 5 +20 0027 02 47 0467
T AT 127K 008 12 120 10 2 20 2.21 1 2 1220 - 44 +17. 5 +20 0028 0248 046 8
T AT 127J 00812 12 0 5 2 20 2.21 1 2 1220 -44 +17. 5 +20 0029 02 49 0469
T AT 227M 00812 22 0 20 2 37 2. 23 1 7 1370 -44 +17. 5 +20 0030 02 50 0470
T AT 227K 008 12 220 10 2 37 2.23 1 7 1370 - 44 +17. 5 +20 0031 0251 047 1
T AT 227J 00812 22 0 5 2 37 2.23 1 7 1370 -44 +17. 5 +20 0032 02 52 0472
T AT 297M 00813 29 0 20 3 34 1. 56 2 6 1770 -64 +17. 5 +20 0033 02 53 0473
T AT 297K 008 13 290 10 3 34 1.56 2 6 1770 - 64 +17. 5 +20 0034 0254 047 4
T AT 297J 00813 29 0 5 3 34 1.56 2 6 1770 -64 +17. 5 +20 0035 02 55 0475
T AT 437M 00813 43 0 20 3 46 1. 42 2 14 1825 -64 +17. 5 +20 0036 02 56 0476
T AT 437K 008 13 430 10 3 46 1.42 2 14 1825 -64 +17. 5 +20 0037 0257 0477
T AT 437J 00813 43 0 5 3 46 1.42 2 14 1825 -64 +17. 5 +20 0038 0258 0478
T AT 857M 00814 85 0 20 4 60 0. 94 4 16 2330 -80 +25 +25 0039 02 59 0479
T AT 857K 008 14 850 10 4 60 0.94 4 16 2330 -80 +25 +25 0040 0260 0480
Max Ripple
@ +85°C
40kHz
(mA)
CDE
Comm ercial
Part Num ber
Cap (µF)
Cap
Tol
)
Case
Code
8 Vo l ts M axi mum at 85°C (5 Volt s at 125°C ), Su r g e Vo lta ge 9.2 at 85°C
Maximum %
Capacitance change
from Room
Temperature
Part Num ber MIL-C-
M39006/22 Failure Rate
Level/%1000 Hours
6 Vo l ts M axi mum at 85°C (4 Volt s at 125°C ), Su r g e Vo lta ge 6.9 at 85°C
Max
DF %
Max
ESR
@+25ºC
()
Maximum DC
Leakage (µA)
Cornell Dubilier 140 Technology Place Liberty, SC 29657 Phone: (864)843-2277 Fax: (864)843-3800 www.cde.com
Wet Tantalum - CLR 79 (MIL-C-39006/22)
CLR 81 (MIL-C-39006/25)
TAT(CLR79)
+25°C
+85°C
&
+125°C -55°C +85°C +125°C M (1.0) P (0.1) R (0.01)
T AT 206M 01011 20 20 1 6 3 .9 8 1 2 820 - 32 +10. 5 +12 0041 0261 0481
T AT 2 06K 01 011
20 10 1 6 3.98 1 2 820 -32 +10.5 +12 0042 0262 0482
T AT 206J 01011 20 5 1 6 3. 98 1 2 820 -32 +10. 5 +12 0043 02 63 0483
T AT 476M 01011 47 20 1 13 3 .6 7 1 2 855 - 36 +14 +16 0044 0264 0484
T AT 4 76K 01 011
47 10 1 13 3.67 1 2 855 -36 +14 +16 0045 0265 0485
T AT 476J 01011 47 5 1 13 3. 67 1 2 855 -36 +14 +16 00 46 02 66 0486
T AT 107M 01012 100 20 2 15 1. 99 1 4 1200 -36 +14 +16 00 47 0267 0487
T AT 1 07K 01 012
100 10 2 15 1.99 1 4 1200 -36 +14 +16 0048 0268 0488
T AT 107J 01012 100 5 2 15 1. 99 1 4 1200 -36 +14 +16 00 49 0269 0489
T AT 187M 01012 180 20 2 30 2. 21 1 7 1365 -36 +14 +16 00 50 0270 0490
T AT 1 87K 01 012
180 10 2 30 2.21 1 7 1365 -36 +14 +16 0051 0271 0491
T AT 187J 01012 180 5 2 30 2. 21 1 7 1365 -36 +14 +16 00 52 0272 0492
T AT 257M 01013 250 20 3 30 1. 59 2 10 1720 -40 +14 +16 0053 0273 0493
T AT 2 57K 01 013
250 10 3 30 1.59 2 10 1720 -40 +14 +16 0054 0274 0494
T AT 257J 01013 250 5 3 30 1. 59 2 10 1720 -40 +14 +16 0055 0275 0495
T AT 397M 01013 390 20 3 44 1. 50 2 16 1800 -64 +17. 5 +20 0056 0276 0496
T AT 3 97K 01 013
390 10 3 44 1.50 2 16 1800 -64 +17.5 +20 0057 0277 0497
T AT 397J 01013 390 5 3 44 1. 50 2 16 1800 -64 +17. 5 +20 0058 0278 0498
T AT 757M 01014 750 20 4 50 0. 88 4 16 2360 -80 +25 +25 0059 0279 0499
T AT 7 57K 01 014
750 10 4 50 0.88 4 16 2360 -80 +25 +25 0060 0280 0500
T AT 156M 01511 15 20 1 5 4 .4 2 1 2 780 - 24 +10. 5 +12 0061 0281 0501
T AT 1 56K 01 511
15 10 1 5 4.42 1 2 780 -24 +10.5 +12 0062 0282 0502
T AT 156J 01511 15 5 1 5 4. 42 1 2 780 -24 +10. 5 +12 0063 0283 0503
T AT 336M 01511 33 20 1 10 4 .0 2 1 2 820 - 28 +14 +16 0064 0284 0504
T AT 3 36K 01 511
33 10 1 10 4.02 1 2 820 -28 +14 +16 0065 0285 0505
T AT 336J 01511 33 5 1 10 4. 02 1 2 820 -28 +14 +16 00 66 02 86 0506
T AT 706M 01512 70 20 2 13 2 .4 6 1 4 1150 -28 +14 +16 0067 0287 0507
T AT 7 06K 01 512
70 10 2 13 2.46 1 4 1150 -28 +14 +16 0068 0288 0508
T AT 706J 01512 70 5 2 13 2. 46 1 4 1150 - 28 +14 +16 0069 0289 0509
T AT 127M 01512 120 20 2 18 1. 99 1 7 1450 -28 +17. 5 +20 0070 0290 0510
T AT 1 27K 01 512
120 10 2 18 1.99 1 7 1450 -28 +17.5 +20 0071 0291 0511
T AT 127J 01512 120 5 2 18 1. 99 1 7 1450 -28 +17. 5 +20 0072 0292 0512
T AT 177M 01513 170 20 3 25 1. 95 2 10 1480 -32 +14 +16 0073 0293 0513
T AT 1 77K 01 513
170 10 3 25 1.95 2 10 1480 -32 +14 +16 0074 0294 0514
T AT 177J 01513 170 5 3 25 1. 95 2 10 1480 -32 +14 +16 0075 0295 0515
T AT 277M 01513 270 20 3 32 1. 57 2 16 1740 -56 +17. 5 +20 0076 0296 0516
T AT 2 77K 01 513
270 10 3 32 1.57 2 16 1740 -56 +17.5 +20 0077 0297 0517
T AT 277J 01513 270 5 3 32 1. 57 2 16 1740 -56 +17. 5 +20 0078 0298 0518
T AT 547M 01514 540 20 4 40 0. 98 6 24 2330 -80 +25 +25 0079 0299 0519
T AT 5 47K 01 514
540 10 4 40 0.98 6 24 2330 -80 +25 +25 0080 0300 0520
T AT 106M 02511 10 20 1 4 5 .3 1 1 2 715 - 16 +8 +9 00 81 0301 0521
T AT 1 06K 02 511
10 10 1 4 5.31 1 2 715 -16 +8 +9 0082 0302 0522
T AT 106J 02511 10 5 1 4 5. 31 1 2 715 -16 +8 +9 00 83 03 03 0523
T AT 226M 02511 22 20 1 6. 6 3 . 98 1 2 825 -20 +10. 5 +12 0084 0304 0524
T AT 2 26K 02 511
22 10 1 6.6 3.98 1 2 825 -20 +10.5 +12 0085 0305 0525
Maximum %
Capacitance change
from Room
Temperature
Part Number MIL-C-
M39006/22 Failure Rate
Level/%1000 Hours
Max
DF %
Max ESR
@+25ºC
()
Maximum DC
Leakage
A)
Max
Rip ple
@ +85°C
40kHz
(mA)
CDE
Comm ercial
Part Num ber
Cap
F)
Cap
Tol
(±)
Case
Code
15 Vo l ts M ax i mu m at 85°C ( 10 Vo l ts at 125°C ), Su r g e Vo l tag e 17.2 at 85°C
25 Vo l ts M ax i mu m at 85°C ( 15 Vo l ts at 125°C ), Su r g e Vo l tag e 28.8 at 85°C
10 Vo l ts M axi mum at 85°C (7 Volt s at 125°C ), Su r g e Vo l tage 11. 5 at 85°C
Cornell Dubilier 140 Technology Place Liberty, SC 29657 Phone: (864)843-2277 Fax: (864)843-3800 www.cde.com
Wet Tantalum - CLR 79 (MIL-C-39006/22)
CLR 81 (MIL-C-39006/25)
TAT(CLR79)
+25°C
+85°C
&
+125°C -55°C +85°C +125°C M (1.0) P (0.1) R (0.01)
T AT 226J 02511 22 5 1 6. 6 3.98 1 2 825 -20 +10. 5 +12 0086 0306 0526
T AT 506M 02512 50 20 2 11 2. 92 1 2 1130 -28 +13 +15 0087 0307 0527
T AT 5 06K 0 2512 50 10 2 11 2.92 1 2 1130 - 28 +13 +15 00 88 0308 0 528
T AT 506J 02512 50 5 2 11 2. 92 1 2 1130 -28 +13 +15 0089 0309 0529
T AT 107M 02512 100 20 2 15 1. 99 1 10 1435 - 28 +13 +15 0090 0310 0530
T AT 1 07K 0 2512 100 10 2 15 1. 99 1 10 1435 -28 +13 +15 00 91 03 11 0 531
T AT 107J 02512 100 5 2 15 1. 99 1 10 1435 -28 +13 +15 0092 0312 0532
T AT 127M 02513 120 20 3 21 2. 32 2 6 1450 -32 +13 +15 00 93 03 13 0533
T AT 1 27K 0 2513 120 10 3 21 2. 32 2 6 1450 -32 +13 +15 00 94 0314 0 534
T AT 127J 02513 120 5 3 21 2. 32 2 6 1450 -32 +13 +15 0095 0315 0535
T AT 187M 02513 180 20 3 26 1. 92 2 18 1525 -48 +13 +15 0096 0316 0536
T AT 1 87K 0 2513 180 10 3 26 1. 92 2 18 1525 -48 +13 +15 00 97 03 17 0 537
T AT 187J 02513 180 5 3 26 1. 92 2 18 1525 -48 +13 +15 0098 0318 0538
T AT 357M 02514 350 20 4 35 1. 33 7 28 1970 - 70 +25 +25 0099 0319 0539
T AT 3 57K 0 2514 350 10 4 35 1. 33 7 28 1970 -70 +25 +25 01 00 03 20 0 540
T AT 805M 03011 8 20 1 4 6. 64 1 2 640 -16 +8 +12 01 01 0321 0541
T AT 8 05K 0 3011 8 10 1 4 6.64 1 2 640 -16 +8 +12 01 02 0322 0 542
T AT 805J 03011 8 5 1 4 6.64 1 2 640 -16 +8 +12 0103 0323 0543
T AT 156M 03011 15 20 1 5 4. 42 1 2 780 -20 +10. 5 +12 01 04 0324 0544
T AT 1 56K 0 3011 15 10 1 5 4. 42 1 2 780 -20 +10. 5 +12 0105 0325 0545
T AT 156J 03011 15 5 1 5 4. 42 1 2 780 -20 +10. 5 +12 01 06 0326 0546
T AT 406M 03012 40 20 2 10 3. 32 1 5 1120 -24 +10.5 +12 0107 0327 0547
T AT 4 06K 0 3012 40 10 2 10 3.32 1 5 1120 - 24 +10. 5 +12 0108 0328 0548
T AT 406J 03012 40 5 2 10 3. 32 1 5 1120 -24 +10. 5 +12 0109 0329 0549
T AT 686M 03012 68 20 2 13 2. 54 1 8 1285 -24 +13 +15 0110 0330 0550
T AT 6 86K 0 3012 68 10 2 13 2.54 1 8 1285 - 24 +13 +15 01 11 0331 0 551
T AT 686J 03012 68 5 2 13 2. 54 1 8 1285 -24 +13 +15 0112 0332 0552
T AT 107M 03013 100 20 3 17 2. 26 2 12 1450 - 28 +10. 5 +12 0113 0333 0553
T AT 1 07K 0 3013 100 10 3 17 2. 26 2 12 1450 -28 +10. 5 +12 01 14 0334 0 554
T AT 107J 03013 100 5 3 17 2. 26 2 12 1450 -28 +10. 5 +12 0115 0335 0556
T AT 157M 03013 150 20 3 23 2. 03 2 18 1525 - 48 +13 +15 0116 0336 0556
T AT 1 57K 0 3013 150 10 3 23 2. 03 2 18 1525 -48 +13 +15 01 17 03 37 0 557
T AT 157J 03013 150 5 3 23 2. 03 2 18 1525 -48 +13 +15 0118 0338 0558
T AT 307M 03014 300 20 4 31 1. 37 8 32 1950 - 60 +25 +25 0119 0339 0558
T AT 3 07K 0 3014 300 10 4 31 1. 37 8 32 1950 -60 +25 +25 01 20 03 40 0 559
T AT 505M 05011 5 20 1 3 7.96 1 2 580 -16 +5 +6 0121 0341 0561
T AT 5 05K 0 5011 5 10 1 3 7.96 1 2 580 -16 +5 +6 01 22 03 42 0 562
T AT 505J 05011 5 5 1 3 7. 96 1 2 580 -16 +5 +6 0123 03 43 0563
T AT 106M 05011 10 20 1 4 5.31 1 2 715 -24 +8 +9 01 24 0344 0564
T AT 1 06K 0 5011 10 10 1 4 5.31 1 2 715 -24 +8 +9 01 25 03 45 0 565
T AT 106J 05011 10 5 1 4 5.31 1 2 715 -24 +8 +9 01 26 0346 0566
T AT 256M 05012 25 20 2 8 4.25 1 5 1005 -20 +10.5 +12 0127 0347 0567
T AT 2 56K 0 5012 25 10 2 8 4.25 1 5 1005 -20 +10.5 +12 0128 0348 0568
T AT 256J 05012 25 5 2 8 4.25 1 5 1005 -20 +10. 5 +12 0129 0349 0569
T AT 476M 05012 47 20 2 11 3. 11 1 9 1155 -28 +13 +15 0130 0350 0570
CDE
Comm ercial
Part Num ber
Cap
F)
Cap
Tol
(±)
Case
Code
Maximum %
Capacitance change
from Room
Temperature
Part Num be r MIL-C-
M39006/22 Failure Rate
Level/%1000 Hours
Max
DF %
Max ESR
@+25ºC
()
Maximum DC
Leakage
A)
Max
Rip p le
@ +85°C
40kHz
(mA)
25 Vo l ts M axi mum at 85°C(15 Volts at 125°C ), Su r g e Vo l t ag e 28. 8 at 85°C
30 Vo l ts M axi mum at 85°C(20 Volts at 125°C ), Su r g e Vo l t ag e 34. 5 at 85°C
50 Vo l ts M axi mum at 85°C(30 Volts at 125°C ), Su r g e Vo l t ag e 57. 5 at 85°C
Cornell Dubilier 140 Technology Place Liberty, SC 29657 Phone: (864)843-2277 Fax: (864)843-3800 www.cde.com
Wet Tantalum - CLR 79 (MIL-C-39006/22)
CLR 81 (MIL-C-39006/25)
TAT(CLR79)
+25°C
+85°C
&
+125°C -55°C +85°C +1 25°C M (1. 0) P (0. 1) R (0.01)
T AT 4 76K 05012 47 10 2 11 3. 11 1 9 1155 -28 +13 +15 0131 0351 0571
T AT 476J 05012 47 5 2 11 3. 11 1 9 11 55 -28 +13 +15 0132 0352 0572
T AT 606M 05013 60 20 3 12 2. 65 2 12 13 35 -16 +10.5 +12 0133 0353 0573
T AT 6 06K 05013 60 10 3 12 2.65 2 12 1335 -16 +10. 5 +12 0134 0354 0574
T AT 606J 05013 60 5 3 12 2. 65 2 12 1335 -16 +10. 5 +12 01 35 0355 0575
T AT 826M 05013 82 20 3 15 2. 43 2 16 14 00 -32 +13 +15 0136 0356 0576
T AT 8 26K 05013 82 10 3 15 2.43 2 16 1400 -32 +13 +15 0137 0357 0577
T AT 826J 05013 82 5 3 15 2. 43 2 16 1400 -32 +13 +15 0138 0358 0578
T AT 167M 05014 160 20 4 17 1. 41 8 32 1900 -50 +25 +25 0139 0359 0579
T AT 1 67K 05014 160 10 4 17 1. 41 8 32 1900 -50 +25 +25 0140 0360 0580
T AT 405M 06011 4 20 1 2 .8 9. 29 1 2 525 -16 +5 +6 01 41 0361 0581
T AT 4 05K 06011 4 10 1 2 . 8 9. 29 1 2 525 -16 +5 +6 0142 03 62 0582
T AT 405J 06011 4 5 1 2. 8 9. 29 1 2 525 -16 +5 +6 01 43 0363 0583
T AT 825M 06011 8 .2 20 1 4 6.47 1 2 625 -24 +8 +9 0144 0364 0584
T AT 8 25K 06011 8 . 2 10 1 4 6. 47 1 2 625 -24 +8 +9 01 45 03 65 0585
T AT 825J 06011 8. 2 5 1 4 6.47 1 2 625 -24 +8 +9 0146 03 66 0586
T AT 206M 06012 20 20 2 7 4.64 1 5 930 -16 +10.5 +12 0147 0367 0587
T AT 2 06K 06012 20 10 2 7 4.64 1 5 930 -16 +10. 5 +12 01 48 03 68 0588
T AT 206J 06012 20 5 2 7 4.64 1 5 930 -16 +10.5 +12 0149 0369 0589
T AT 396M 06012 39 20 2 10 3. 4 1 9 1110 -28 +10. 5 +12 0150 0370 0590
T AT 3 96K 06012 39 10 2 10 3.4 1 9 11 10 -28 +10. 5 +12 01 51 03 71 0591
T AT 396J 06012 39 5 2 10 3. 4 1 9 1110 - 28 +10.5 +12 0152 0372 0592
T AT 506M 06013 50 20 3 10 2. 65 2 12 1330 16 +10. 5 +12 0153 0373 0593
T AT 5 06K 06013 50 10 3 10 2. 65 2 12 1330 16 +10. 5 +12 01 54 03 74 0594
T AT 506J 06013 50 5 3 10 2. 65 2 12 1330 16 +10. 5 +12 0155 0375 0595
T AT 686M 06013 68 20 3 13 2. 54 2 16 13 65 -32 +10.5 +12 0156 0376 0596
T AT 6 86K 06013 68 10 3 13 2. 54 2 16 1365 -32 +10. 5 +12 01 57 03 77 0597
T AT 686J 06013 68 5 3 13 2. 54 2 16 1365 -32 +10.5 +12 0158 0378 0598
T AT 147M 06014 140 20 4 16 1. 52 8 32 1850 -40 +20 +20 0159 0379 0599
T AT 1 47K 06014 140 10 4 16 1. 52 8 32 1850 -40 +20 +20 01 60 03 80 0 600
T AT 355M 07511 3 .5 20 1 2. 5 9. 48 1 2 525 -16 +5 +6 0161 0381 0601
T AT 3 55K 07511 3 . 5 10 1 2. 5 9. 48 1 2 525 -16 +5 +6 0162 03 82 0602
T AT 355J 07511 3. 5 5 1 2. 5 9. 48 1 2 525 -16 +5 +6 01 63 0383 0603
T AT 685M 07511 6 .8 20 1 3. 5 6. 83 1 2 610 -20 8 +9 0164 03 84 0604
T AT 6 85K 07511 6 . 8 10 1 3 .5 6. 83 1 2 610 -20 8 +9 0165 0385 0605
T AT 685J 07511 6. 8 5 1 3. 5 6. 83 1 2 610 -20 8 +9 0166 0386 0 606
T AT 156M 07512 15 20 2 6 5.31 1 5 890 -16 +8 +9 0167 0387 0 607
T AT 1 56K 07512 15 10 2 6 5.31 1 5 890 -16 +8 +9 0168 03 88 0608
T AT 156J 07512 15 5 2 6 5.31 1 5 890 -16 +8 +9 0169 0389 0609
T AT 336M 07512 33 20 2 10 4. 02 1 10 10 00 -24 +10.5 +15 0170 0390 0610
T AT 3 36K 07512 33 10 2 10 4. 02 1 10 1000 -24 +10. 5 +15 01 71 03 91 0611
T AT 3 36J 07512 33 5 2 10 4. 02 1 10 1000 -24 +10. 5 +15 0172 0392 0612
T AT 406M 07513 40 20 3 9 2.99 2 12 12 50 -16 +10. 5 +12 01 73 0393 0613
T AT 4 06K 07513 40 10 3 9 2.99 2 12 12 50 -16 +10. 5 +12 0174 0394 0614
T AT 406J 07513 40 5 3 9 2.99 2 12 1250 -16 +10. 5 +12 0175 0395 0615
T AT 566M 07513 56 20 3 11 2. 61 2 17 13 35 -28 +10.5 +12 0176 0396 0616
75 Vo l ts M axi mu m at 85°C(5 0 Vo lts at 125 °C ), Su r g e Vo l tage 86. 2 at 85°C
C D E C o mmer ci al
Par t N u mb er Cap
F)
Cap
Tol
(±)
Case
Code Max
DF %
Max ESR
@+25ºC
()
60 Vo l ts M axi mu m at 85°C(4 0 Vo lts at 125 °C ), Su r g e Vo l tage 69 at 85°C
Maxim um DC
L eakag e (µA) Max
Ri pp le @
+85°C
40kH z
(mA)
50 Vo l ts M axi mu m at 85°C(3 0 Vo lts at 125 °C ), Su r g e Vo l tage 57. 5 at 85°C
Maximum % Capacitance
ch an g e fr om R o o m
Tem perature
Change from
Par t Number M I L -C-M3900 6/ 22
F ai l u re Rate L evel /%100 0
Hours
Cornell Dubilier 140 Technology Place Liberty, SC 29657 Phone: (864)843-2277 Fax: (864)843-3800 www.cde.com
Wet Tantalum - CLR 79 (MIL-C-39006/22)
CLR 81 (MIL-C-39006/25)
TAT(CLR79)
+25°C
+85°C
&
+125°C -55°C +85°C +125°C M (1.0) P (0.1) R (0.01)
T AT 566K 07513
56 10 3 11 2.61 2 17 1335 -28 10.5 +15 0177 0397 0617
T AT 566J 07 513 56 5 3 11 2.61 2 17 1335 -28 1 0.5 +15 0178 0398 0618
T AT 117M 07514 110 20 4 12 1. 45 9 36 1850 -35 +20 +20 0 179 0399 0619
T AT 117K 07514
110 10 4 12 1.45 9 36 1850 -35 +20 +20 0180 0400 0620
T AT 255M 10011 2. 5 20 1 2 10. 62 1 2 505 -16 +7 +8 0181 0401 0621
T AT 255K 10011
2.5 10 1 2 10.62 1 2 505 -16 +7 +8 0182 0402 0622
T AT 255J 10 011 2.5 5 1 2 10. 62 1 2 505 -16 +7 +8 0 183 0403 0623
T AT 475M 10011 4. 7 20 1 3 8. 47 1 2 565 -16 +7 +8 0184 0404 0624
T AT 475K 10011
4.7 10 1 3 8.47 1 2 565 -16 +7 +8 0185 0405 0625
T AT 475J 10 011 4.7 5 1 3 8. 47 1 2 56 5 -16 +7 +8 0 186 0406 0626
T AT 116M 10012 11 20 2 5 6. 03 1 4 835 -16 +8 +8 0187 0407 0627
T AT 116K 10012
11 10 2 5 6.03 1 4 835 -16 +8 +8 0188 0408 0628
T AT 116J 10 012 11 5 2 5 6. 03 1 4 83 5 -16 +8 +8 0189 0409 0629
T AT 226M 10012 22 20 2 7 .5 4. 52 1 9 965 -16 +8 +8 0190 0410 0630
T AT 226K 10012
22 10 2 7.5 4.52 1 9 965 -16 +8 +8 0191 0411 0631
T AT 226J 10 012 22 5 2 7. 5 4. 52 1 9 965 -16 +8 +8 0192 0412 0632
T AT 306M 10013 30 20 3 7 3. 10 2 12 1240 -16 +8 +8 0 193 0413 0633
T AT 306K 10013
30 10 3 7 3.10 2 12 1240 -16 +8 +8 0194 0414 0634
T AT 306J 10 013 30 5 3 7 3. 10 2 12 1240 -16 +8 +8 0 195 0415 0635
T AT 436M 10013 43 20 3 8 .5 2. 62 2 17 1335 -20 +8 +8 0 196 0416 0636
T AT 436K 10013
43 10 3 8.5 2.62 2 17 1335 -20 +8 +8 0197 0417 0637
T AT 436J 10013 43 5 3 8. 5 2. 62 2 17 1335 -20 +8 +8 0 198 0418 0638
T AT 866M 10014 86 20 4 10 1. 54 9 36 1800 -25 +15 +15 0199 0419 0639
T AT 866K 10014
86 10 4 10 1.54 9 36 1800 -25 +15 +15 0200 0420 0640
T AT 175M 12511 1. 7 20 1 2 15. 61 1 2 415 -16 +7 +8 0201 0421 0641
T AT 175K 12511
1.7 10 1 2 15.61 1 2 415 -16 +7 +8 0202 0422 0642
T AT 175J 12 511 1.7 5 1 2 15. 61 1 2 415 -16 +7 +8 0 203 0423 0643
T AT 365M 12511 3. 6 20 1 2. 7 9. 95 1 2 520 -16 +7 +8 0204 0424 0644
T AT 365K 12511
3.6 10 1 2.7 9.95 1 2 520 -16 +7 +8 0205 0425 0645
T AT 365J 12 511 3.6 5 1 2. 7 9. 95 1 2 520 -16 +7 +8 0206 0426 0646
T AT 905M 12512 9 20 2 5 7. 37 1 5 755 -16 +7 +8 0207 0427 0647
T AT 905K 12512
9 10 2 5 7.37 1 5 755 -16 +7 +8 0208 0428 0648
T AT 905J 12 512 9 10 2 5 7. 37 1 5 755 -16 +7 +8 0 209 0429 0649
T AT 146M 12512 14 20 2 6 5. 69 1 7 860 -16 +7 +8 0210 0430 0650
T AT 146K 12512
14 10 2 6 5.69 1 7 860 -16 +7 +8 0211 0431 0651
T AT 146J 12 512 14 5 2 6 5. 69 1 7 86 0 -16 +7 +8 0212 0432 0652
T AT 186M 12513 18 20 3 5 3. 69 2 9 1130 -16 +7 +8 0213 0433 0653
T AT 186K 12513
18 10 3 5 3.69 2 9 1130 -16 +7 +8 0214 0434 0654
T AT 186J 12 513 18 5 3 5 3. 69 2 9 1130 -16 +7 +8 0 215 0435 0655
T AT 256M 12513 25 20 3 6 3. 18 2 13 1200 -16 +7 +8 0 216 0436 0656
T AT 256K 12513
25 10 3 6 3.18 2 13 1200 -16 +7 +8 0217 0437 0657
T AT 256J 12 513 25 5 3 6 3. 18 2 13 1200 -16 +7 +8 0 218 0438 0658
T AT 566M 12514 56 20 4 6 .5 1. 54 10 40 1800 -25 +15 +15 0219 0439 0659
T AT 566K 12514
56 10 4 6.5 1.54 10 40 1800 -25 +15 +15 0220 0440 0660
Cap
F)
Cap
Tol
(±)
Case
Code
Maximum %
Capacitance change
from Room
Tem perature
Part Num be r MIL-C-
M39006/22 Failure Rate
Level/%1000 Hours
100 Vo l ts M aximu m at 85°C (65Vo l ts at 125°C ), Su r g e Vol tag e 115 at 85°C
125 Vo l ts M aximu m at 85°C (85 Vo l ts at 125°C ), Su r ge Vo l tag e 144 at 85°C
75 Vo l ts M aximu m at 85°C (50 Vo l ts at 125°C ), Su r ge V ol tag e 86. 2 at 85°C
Max
DF %
Max ESR
@+25ºC
()
Maximum DC
Leakage
A)
Max
Ripple
@ +85°C
40kHz
(mA)
CDE
Com m ercial
Part Num ber
Cornell Dubilier 140 Technology Place Liberty, SC 29657 Phone: (864)843-2277 Fax: (864)843-3800 www.cde.com
Wet Tantalum - CLR 79 (MIL-C-39006/22)
CLR 81 (MIL-C-39006/25)
TAX (CLR81)
+25°C
+8C
& +125°C -55°C +85°C +125°C M (1.0) P (0.1) R (0.01)
T AX227 M 00611 220 20 1 50 3. 0 2 2 9 10 00 -64 +13 +16 0 001 0089 0177
T AX227 K 00611 220 10 1 5 0 3 . 02 2 9 10 00 -64 +13 +16 0 002 0090 0178
T AX827 M 00612 820 20 2 155 2. 5 1 3 1 4 1500 -8 8 +16 +20 0 003 0091 0179
T AX827 K 00612 820 10 2 155 2. 5 1 3 1 4 1500 -88 +16 +20 0 004 0092 0180
T AX158 M 00613 15 00 20 3 172 1. 5 2 5 2 0 1900 -90 +20 +25 0 005 0093 0181
T AX158 K 00613 1500 10 3 172 1 . 52 5 20 1900 -90 +20 +25 0 006 0094 0182
T AX228 M 00614 22 00 20 4 170 1. 0 3 6 2 4 2300 -90 +25 +30 0 007 0095 0183
T AX228 K 00614 2200 10 4 170 1 . 03 6 24 2300 -90 +25 +30 0 008 0096 0184
T AX187 M 00811 180 20 1 41 3. 0 2 2 9 10 00 -60 +13 +16 0 009 0097 0185
T AX187 K 00811 180 10 1 4 1 3 . 02 2 9 10 00 -60 +13 +16 0 010 0098 0186
T AX687 M 00812 680 20 2 130 2. 5 4 3 1 4 1500 -8 3 +16 +20 0 011 0099 0187
T AX687 K 00812 680 10 2 130 2. 5 4 3 1 4 1500 -83 +16 +20 0 012 0100 0188
T AX158 M 00813 15 00 20 3 170 1. 5 0 5 2 0 1900 -90 +20 +25 0 013 0101 0189
T AX158 K 00813 1500 10 3 170 1 . 50 5 20 1900 -90 +20 +25 0 014 0102 0190
T AX188 M 00814 18 00 20 4 138 1. 0 2 7 2 5 2300 -90 +25 +30 0 015 0103 0191
T AX188 K 00814 1800 10 4 138 1 . 02 7 25 2300 -90 +25 +30 0 016 0104 0192
T AX157 M 01011 150 20 1 3 4 3. 01 2 9 9 00 -55 +13 +16 0 017 01 05 0193
T AX157 K 01011 150 10 1 3 4 3 . 01 2 9 900 -55 +13 +16 0 018 0106 0194
T AX567 M 01012 560 20 2 106 2. 5 1 3 1 6 1450 -7 7 +16 +20 0 019 0107 0195
T AX567 K 01012 560 10 2 106 2. 5 1 3 1 6 1450 -77 +16 +20 0 020 0108 0196
T AX128 M 01013 12 00 20 3 137 1. 5 1 5 2 0 1850 -88 +20 +25 0 021 0109 0197
T AX128 K 01013 1200 10 3 137 1 . 51 5 20 1850 -88 +20 +25 0 022 0110 0198
T AX158 M 01014 15 00 20 4 114 1. 0 1 7 2 5 2300 -88 +25 +30 0 023 0111 0199
T AX158 K 01014 1500 10 4 114 1 . 01 7 25 2300 -88 +25 +30 0 024 0112 0200
T AX107 M 01511 100 20 1 3 0 3. 98 2 9 9 00 -44 +13 +16 0 025 01 13 0201
T AX107 K 01511 100 10 1 3 0 3 . 98 2 9 900 -44 +13 +16 0 026 0114 0202
T AX397 M 01512 390 20 2 7 4 2. 52 3 16 1450 -6 6 +16 +20 0 027 0115 0203
T AX397 K 01512 390 10 2 7 4 2 . 52 3 16 1450 -66 +16 +20 0 028 0116 0204
T AX827 M 01513 820 20 3 111 1. 8 0 6 2 4 1800 -7 7 +20 +25 0 029 0117 0205
T AX827 K 01513 820 10 3 111 1. 8 0 6 2 4 1800 -77 +20 +25 0 030 0118 0206
T AX108 M 01514 10 00 20 4 9 2 1 . 22 8 32 2300 -77 +25 +30 0 031 0119 020 7
T AX108 K 01514 1000 10 4 92 1 . 22 8 32 2300 -77 +25 +30 0 032 0120 0208
T AX686 M 02511 68 20 1 22 4 . 29 2 9 850 -4 0 +12 +15 0033 01 21 020 9
T AX686 K 02511 68 10 1 2 2 4 . 29 2 9 850 -4 0 +12 +15 0034 01 22 021 0
T AX277 M 02512 270 20 2 5 5 2. 70 3 16 1400 -6 2 +13 +16 0 035 0123 0211
T AX277 K 02512 270 10 2 5 5 2 . 70 3 16 1400 -62 +13 +16 0 036 0124 0212
T AX567 M 02513 560 20 3 7 6 1. 80 7 28 1750 -7 2 +20 +25 0 037 0125 0213
T AX567 K 02513 560 10 3 7 6 1 . 80 7 28 1750 -72 +20 +25 0 038 0126 0214
T AX687 M 02514 680 20 4 6 3 1. 23 8 32 2100 -7 2 +25 +30 0 039 0127 0215
T AX687 K 02514 680 10 4 6 3 1 . 23 8 32 2100 -72 +25 +30 0 040 0128 0216
T AX566 M 03011 56 20 1 22 5 . 21 2 9 800 -3 8 +12 +15 0041 01 29 021 7
T AX566 K 03011 56 10 1 2 2 5 . 21 2 9 800 -3 8 +12 +15 0042 01 30 021 8
T AX227 M 03012 220 20 2 4 2 2. 53 3 16 1200 -6 0 +13 +16 0 043 0131 0219
T AX227 K 03012 220 10 2 4 2 2 . 53 3 16 1200 -60 +13 +16 0 044 0132 0220
Maximum %
Capacitance Change
from Room
Tem perature
Part Number MIL-C-
M39006/25 Failure Rate
Level/%1000 Hours
Cap
Tol
)
Case
Code
Maximum DC
LeakageA)
Max
Ripple
@ +85°C
40kHz
(mA)
6 Volts Maximum at 85°C(4 Volts at 125°C), Surge Voltage 6.9 at 85°C
Max
DF %
Max ESR
@+25ºC
()
30 Volts Maximum at 85°C(20 Volts at 125°C), Surge Voltage 34.5 at 85°C
10 Volts Maximum at 85°C(7 Volts at 125°C), Surge Voltage 11.5 at 85°C
15 Volts Maximum at 85°C(10 Volts at 125°C), Surge Voltage 17.2 at 85°C
25 Volts Maximum at 85°C(15 Volts at 125°C), Surge Voltage 28.8 at 85°C
8 Volts Maximum at 85°C(5 Volts at 125°C), Surge Voltage 9.2 at 85°C
CDE Com mercial
Part Num ber
Cap
F)
Cornell Dubilier 140 Technology Place Liberty, SC 29657 Phone: (864)843-2277 Fax: (864)843-3800 www.cde.com
Wet Tantalum - CLR 79 (MIL-C-39006/22)
CLR 81 (MIL-C-39006/25)
TAX (CLR81)
+25°C
+85°C
&
+125°C -55°C +85°C +125°C M (1.0) P (0.1) R (0.01)
T AX477M 03013 470 20 3 64 1. 81 8 32 1500 -65 +20 +25 0045 0133 0221
T AX477K 03013 470 10 3 64 1. 81 8 32 1500 -65 +20 +25 0046 0134 0222
T AX567M 03014 560 20 4 55 1. 30 9 36 2000 -65 +25 +30 0047 0135 0223
T AX567K 03014 560 10 4 55 1. 30 9 36 2000 -65 +25 +30 0048 0136 0224
T AX336M 05011 33 20 1 12. 3 4. 95 2 9 700 -29 +10 +12 0049 0137 0225
T AX336K 05011 33 10 1 12. 3 4. 95 2 9 700 -29 +10 +12 0050 0138 0226
T AX127M 05012 120 20 2 22. 5 2. 49 4 24 1200 -42 +12 +15 0 051 0139 0227
T AX127K 05012 120 10 2 22. 5 2. 49 4 24 1200 -42 +12 +15 0052 0140 0228
T AX277M 05013 270 20 3 37 1. 82 8 32 1450 -46 +20 +25 0053 0141 0229
T AX277K 05013 270 10 3 37 1. 82 8 32 1450 -46 +20 +25 0054 0142 0230
T AX337M 05014 330 20 4 38 1. 53 9 36 1900 -46 +25 +30 0055 0143 0231
T AX337K 05014 330 10 4 38 1. 53 9 36 1900 -46 +25 +30 0056 0144 0232
T AX276M 06011 27 20 1 10. 2 5. 01 3 12 700 -24 +10 +12 0057 0145 0233
T AX276K 06011 27 10 1 10. 2 5. 01 3 12 700 -24 +10 +12 0058 0146 0234
T AX107M 06012 100 20 2 19 2. 52 4 20 1100 -36 +12 +15 0059 0147 0235
T AX107K 06012 100 10 2 19 2. 52 4 20 1100 -36 +12 +15 0060 0148 0236
T AX227M 06013 220 20 3 30 1. 81 8 32 1400 -40 +16 +20 0061 0149 0237
T AX227K 06013 220 10 3 30 1. 81 8 32 1400 -40 +16 +20 0062 0150 0238
T AX277M 06014 270 20 4 27 1. 33 9 36 1850 -45 +20 +25 0063 0151 0239
T AX277K 06014 270 10 4 27 1. 33 9 36 1850 -45 +20 +25 0064 0152 0240
T AX226M 07511 22 20 1 8. 5 5. 13 3 12 600 -19 +10 +12 0065 0153 0241
T AX226K 07511 22 10 1 8. 5 5. 13 3 12 600 -19 +10 +12 0066 0154 0242
T AX826M 07512 82 20 2 15. 2 2. 46 4 24 1000 -30 +12 +15 0067 0155 0243
T AX826K 07512 82 10 2 15. 2 2. 46 4 24 1000 -30 +12 +15 0068 0156 0244
T AX187M 07513 180 20 3 24. 4 1. 80 9 36 1300 -35 +16 +20 0 069 0157 0245
T AX187K 07513 180 10 3 24. 4 1. 80 9 36 1300 -35 +16 +20 0070 0158 0246
T AX227M 07514 220 20 4 37 2. 23 10 40 1800 -40 +20 +25 0071 0159 0247
T AX227K 07514 220 10 4 37 2. 23 10 40 1800 -40 +20 +25 0072 0160 0248
T AX106M10011 10 20 1 4.5 5. 97 3 12 800 -17 +10 +12 0073 0161 0249
T AX106K10011 10 10 1 4.5 5. 97 3 12 800 -17 +10 +12 0074 0162 0250
T AX396M10012 39 20 2 10. 4 3. 54 5 24 1300 -20 +12 +15 0075 0163 0251
T AX396K10012 39 10 2 10. 4 3. 54 5 24 1300 -20 +12 +15 0076 0164 0252
T AX686M10013 68 20 3 11. 3 2. 21 10 40 1600 -30 +14 +16 0077 0165 0253
T AX686K10013 68 10 3 11. 3 2. 21 10 40 1600 -30 +14 +16 0078 0166 0254
T AX127M10014 120 20 4 25 2. 76 12 48 2000 -35 +15 +17 0079 0167 0255
T AX127K10014 120 10 4 25 2. 76 12 48 2000 -35 +15 +17 0080 0168 0256
T AX685M12511 6. 8 20 1 6 11. 71 3 12 700 -14 +10 +12 0081 0169 0257
T AX685K12511 6.8 10 1 6 11. 71 3 12 700 -14 +10 +12 0082 0170 0258
T AX276M12512 27 20 2 7.2 3. 54 5 24 1200 -18 +12 +15 0083 0171 0259
T AX276K12512 27 10 2 7.2 3. 54 5 24 1200 -18 +12 +15 0084 0172 0260
T AX476M12513 47 20 3 7.9 2. 23 10 40 1500 -26 +14 +16 0085 0173 0261
T AX476K12513 47 10 3 7.9 2. 23 10 40 1500 -26 +14 +16 0086 0 174 0262
T AX826M12514 82 20 4 17. 4 2. 82 12 48 1900 -30 +15 +17 0087 0175 0263
T AX826K12514 82 10 4 17. 4 2. 82 12 48 1900 -30 +15 +17 0088 0176 0264
100 Volts M axim um at 85°C(65Volts at 125°C), Surge Voltage 115 at 85°C
125 Volts M axim um at 85°C(85 Volts at 125°C), Surge Voltage 144 at 85°C
Cap
Tol
)
Case
Code
60 Volts M axim um at 85°C(40 Volts at 125°C), Surge Voltage 69 at 85°C
75 Volts M axim um at 85°C(50 Volts at 125°C), Surge Voltage 86.2 at 85°C
Maximum %
Capacitance Change
from Room
Tem perature
Part Num ber M IL-C-
M39006/25 Failure Rate
Leve l/%1000 HoursCDE Com m ercial
Part Num ber
Cap
F)
30 Volts M axim um at 85°C(20 Volts at 125°C), Surge Voltage 34.5 at 85°C
50 Volts M axim um at 85°C(30 Volts at 125°C), Surge Voltage 57.5 at 85°C
Maximum DC
Leak age
A)
Max
Ripple
@ +85°C
40kHz
(mA)
Max
DF %
Max ESR
@+25ºC
()
Cornell Dubilier 140 Technology Place Liberty, SC 29657 Phone: (864)843-2277 Fax: (864)843-3800 www.cde.com
Wet Tantalum - CLR 79 (MIL-C-39006/22)
CLR 81 (MIL-C-39006/25)
Performance Testing
Seal: MIL-STD-202 - Method 112
Conditions A, or D, and C
Specified Pulse Shock Test: MIL-STD-202 - Method 213 includes the following:
Condition D (500g’s)
Mount the capacitor by its body securely on a fixture taking special care not to squeeze the leads.
While testing apply DC rated voltage. Record whether open or short circuiting, arching, or intermittent contact
occurs. Use detecting equipment capable of detecting a disruption at a period of time up to 0.5 ms.
At the conclusion of testing examine the capacitors for evidence of arcing, breakdown, or mechanical damage.
Thermal Shock: MIL-STD-202 – Method 107, Condition A (with step 3 at +125°C).
In accordance with MIL-PRF-39006, the following shall apply:.
Take measurements before and after cycling.
Take measurements at 15-minute intervals at 300 cycles (Group C).
Take final measurements at room temperature.
High Frequency Vibration: MIL-STD-202 - Method 204 includes the following:
Condition H (80g’s)
Mount the capacitor body securely on a fixture with the leads firmly supported.
Apply DC rated voltage while measuring specific electrical load conditions.
The vibration duration is 4 hours in two perpendicular directions for an overall time of 8 hours.
Take measurements during the last cycle vibration to determine open, short-circuiting or intermittent operation.
Use detecting equipment capable of detecting a disruption at a period of time of 0.5ms or greater. Assess the
units for mechanical damage and test for these electrical requirements:.
oDC Leakage — Not greater than 1.25 initial limit
oCapacitance — No change greater than ±5% of the initial limit
oDF — Not greater than 1.15 of initial limit
Random Vibration: MIL-STD-202 – Method 214
Test condition II-K (51 g’s)
Salt atmosphere: MIL-STD-202 – Method 101
Condition B 48 hours
Solderability: MIL-STD-202 – Method 208
Test both terminations with the insertion depth of flux and solder within .062" of welded seam.
Lead Terminal Strength:
Pull Test: MIL-STD-202 – Method 211, condition A
Wire-lead bend: Per MIL-PRF-39006.
During the test securely clamp the capacitor body. Apply a force of 3 pounds or 1.4 kg for 30 seconds.
Moisture resistance: MIL-STD-202- Method 106, which includes the following:
Mount the capacitor body securely on a fixture taking special care not to squeeze the leads.
Apply 6 volts, polarizing and load voltage
At the time of the capacitors complete their final cycle remove them from the humidity chamber and measure
per MIL-PRF-30006 for DC Leakage, dissipation factor, and capacitance.
oDCL: 125% (Maximum) of +25°C value of standard ratings table
oCap: Within ±8% of initial measurement
oDF: 115% (maximum) of initial requirement
Cornell Dubilier 140 Technology Place Liberty, SC 29657 Phone: (864)843-2277 Fax: (864)843-3800 www.cde.com
Wet Tantalum - CLR 79 (MIL-C-39006/22)
CLR 81 (MIL-C-39006/25)
Dielectric withstanding voltage
MIL-STD-202 – Method 301, 2000 VDC minimum
Insulation Resistance (IR): MIL-STD-202 – Method 302, condition B
100 Megohms minimum
Low temperature storage: MIL-STD-810 – Method 502
DCL and DF: Initial requirements
•∆Cap within ±5% of initial measurement
Low and high temperature stability: –55°°
°°
°C to +125°°
°°
°C.
Measure capacitors for thermal stability by testing at these temperatures in this order: +25°C, –55°C, +25°C, +85°C,
+125°C, and +25°C. Measure Capacitance and DF at the temperatures listed below with the exception of the DCL, which
is not measured at –55°C.
Step 1 (+25°C)
DCL and DF: See standard ratings table
Cap: Within tolerance of standard ratings table
Step 2 (–55°C)
Impedance and Cap: See standard ratings table
Step 3 (+25°C)
DCL and DF: See standard ratings table
Cap: Within ±5% of step one value
Step 4 (+85°C)
Cap, DCL, and DF: See standard ratings table
Step 5 (+125°C)
Cap, DCL, and DF: See standard ratings table
Step 6 (+25°C)
DCL and DF: See standard ratings table
Cap: Within ±5% of step one value
Resistance to Soldering Heat: MIL-STD-202- Method 210, condition C
DCL and DF: See standard ratings table
•∆Cap: Within ±5% of initial measurement
Life test at 85°°
°°
°C/125°°
°°
°C, 2000 hours: MIL-STD-202 – Method 108
DCL and DF: See standard ratings table
•∆Cap: Within ±10% of initial measurement
Cross Reference
Type Series MIL Type Kemet Sprague Tansitor Mallory Arcotronics
Typical ESR, C,V TAT M39006/22 T192 135D AQ/HAQ THT/TLX TH
Extended Range TAX M39006/25 T195 135D AR/HAR THT/TLX TH
Cornell Dubilie r
These capacitor types are not exactly the same. Review the specifications before purchase to assure interchangeability
Cornell Dubilier 140 Technology Place Liberty, SC 29657 Phone: (864)843-2277 Fax: (864)843-3800 www.cde.com
Wet Tantalum - CLR 79 (MIL-C-39006/22)
CLR 81 (MIL-C-39006/25)
Application Guide
120 Hz 1 kHz 1 0 kHz 40 kHz 100 kHz
55° 85° 105° 125° 55° 8 105° 125° 55° 85° 105° 125° 55° 85° 105° 125° 55° 85° 105° 125°
% OF + 85°
RATED
PE AK V OLTAGE
100% .60 .39 - - .72 .45 - - .88 .55 - - 1.0 .63 - - 1.1 .69 - -
90% .60 .46 - - .72 .55 - - .88 .67 - - 1.0 .77 - - 1.1 .85 - -
80% .60 .52 .35 - .72 .62 .42 .88 .76 .52 - 1.0 .87 .59 - 1.1 .96 .65 -
70% .60 .58 .36 - .72 .70 .52 .88 .85 .64 - 1.0 .97 .73 - 1.1 1.07 .80 -
66 2/3%
and below .60 .60 .37 .27 .72 .72 .55 .32 .88 .88 .68 .40 1.0 1.0 .77 .45 1.1 1.1 .85 .50
RIPPLE CURRENT RIPPLE VOLTAGE
The ripple current listed in the Ratings Table for each The peak of the applied AC ripple voltage plus the applied DC
capacitor rating is the maximum permissible rms ripple voltage must not exceed the DC voltage rating of the cap-
current at 40 kHz, 85°C and 2/3 of the 85°C peak voltage. acitor either forward or reverse.
The rms ripple rating at 85°C and 40 kHz is based on a Capacitors must be biased such that the negative peak
maximum internal temperature rise of 50°C. The maximum is not more negative than –3 volts and the positive peak
allowable internal temperature rise decreases linearly does not exceed the voltage rating of the capacitor.
from 50°C to 10°C at an ambient of 125°C.
The applied DC voltage should be of sufficient magnitude
RIPPLE CURRENT MULTIPLIERS to prevent polarity reversal in excess of 3 volts at 85°C
The rms ripple current capability is shown in the Standard and 2 volts at 125°C.
Ratings Table for each rating at 85°C ambient and at 40 kHz.
For operation at other temperatures and frequencies use CAUTIONS AGAINST MISAPPLICATION
the multipliers shown in the Ripple Current Multipliers Table. 1. Do not operate at temperatures above the maximum rated.
2. Do not exceed rated WVdc and Surge Voltage of the capacitor.
SHELF LIFE 3. Do not apply ripple voltage or ripple current in excess of
These capacitors have an expected shelf life of ten or specification limits.
more years when stored at room temperature. Cold
storage has no adverse effects on the capacitor. Violations of above can be hazardous and can cause capacitor
failure or equipment failure.
RIPPLE CURRENT MULTIPLIERS FOR FREQUENCY, TEMPERATURE, AND APPLIED PEAK VOLTAG
E
APPLIED RIPPLE CURRENT FREQUENCY
RIPPLE CURRENT MULTIPLIERS
OP ERATING TEMPERAT URE ° C
AMBIENT STILL
AIR