SPECIFICATION
PSD-30A-5 PSD-30B-5 PSD-30C-5 PSD-30B-12 PSD-30C-12 PSD-30B-24 PSD-30C-24PSD-30A-12 PSD-30A-24
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISE,HOLDUP TIME
VOLTAGERANGE
EFFICIENCY (Typ.)
INPUT
EMSIMMUNITY
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
DCCURRENT
5V 12V 24V
5A 2.5A 1.25A
0~5A 0~2.5A 0~1.25A
25W 30W 30W
100mVp-p 120mVp-p 150mVp-p
±2.0% ±1.0% ±1.0%
4.5~5.5VDC 11~13.5VDC 22~26VDC
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
±1.0%
2s,50ms,------atfullload
A:9~18VDCB:18~36VDCC:36~72VDC
77%
4.5A/12V 2.5A/24V 1.1A/48V
105~150% ratedoutputpower
6~7.5V 14~16.5V 27~32.5V
Protectiontype:
Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
CompliancetoEN55022(CISPR22)ClassB
DesignrefertoLVD
Complianceto ENV50204,EN55024,lightEN61000-4-2,3,4,6,8; industrylevel,criteria A
-20~+60 (Refertooutputloadderatingcurve)℃
20~90%RHnon-condensing
-20~+85 ,10~95%RH℃
± ℃ ℃)0.03%/ (0~50
10~500Hz,2G10min./1cycle,60min.eachalongX, Y,Zaxes
101.6*50.8*30mm(L*W*H)
FileName:PSD-30-SPEC2012-06-25
SAFETY STANDARDS
30WSingleOutputDC-DCConverter PSD-30 series
$
$
$
$
$
$
$
$
$
2:1 wide input range
Protections: Short circuit / Overload / Over voltage/Reverse polarity
1500VAC I/O isolation
Cooling by free air convection
Built-in EMI filter, low ripple noise
100% full load burn-in test
Low cost
High reliability
year warranty2
■Features :
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
EMICONDUCTION&RADIATION
ENVIRONMENT
PROTECTION
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:1.5KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC
SAFETY &
EMC
(Note4)
1. All parameters NOT specially mentioned are measured at 12,24,48VDC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
℃
(As available on http://www.meanwell.com)
79% 80% 77% 80% 82% 78% 83% 83%
REVERSEPOLARITY
Byinternalfuseopen
Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
0.15kg 84pcs/12.6kg/0.82CUFT;
902.4Khrsmin.MIL-HDBK-217F(25 )℃