Film Capacitors
Metallized Polypropylene Film Capacitors (MKP)
Series/Type: B32671P ... B32673P
Date: April 2014
© EPCOS AG 2014. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without EPCOS' prior express consent is prohibited.
Typical applications
PFC (Power Factor Correction)
Climatic
Max. operating temperature: 125 °C
Climatic category (IEC 60068-1): 55/110/56
Construction
Dielectric: polypropylene (PP)
Wound capacitor technology
Plastic case (UL 94 V-0)
Epoxy resin sealing
Features
Very compact design
Very small dimensions
Very high ripple and peak current
High frequency AC operation capability
High voltage capability
Excellent self-healing property
RoHS-compatible
Halogen-free capacitors available on request
Terminals
Parallel wire leads, lead free, tinned
Special lead lengths available on request
Marking
Manufacturer's logo
Lot number, series number
Rated capacitance (coded)
Capacitance tolerance (code letter)
Rated DC voltage
Date of manufacture (coded)
Delivery mode
Bulk (untaped)
Taped (Ammo pack or reel)
For notes on taping, refer to chapter "Taping and packing“.
Dimensional drawing
Dimensions in mm
Lead spacing
±0.4
Lead diameter
d1±0.05
Type
10 0.6 B32671P
15 0.8 B32672P
22.5 0.8 B32673P
Metallized polypropylene film capacitors (MKP) B32671P ... B32673P
Power Factor Correction
Page 2 of 18Please read Cautions and warnings and
Important notes at the end of this document.
Overview of available types
Lead spacing 10 mm 15 mm 22.5 mm
Type B32671P B32672P B32673P
Page 4 5 6
VRMS (V AC) 160 200 200 160 200 200 160 200 200
VR(V DC) 450 520 630 450 520 630 450 520 630
CR(µF)
0.068
0.082
0.10
0.15
0.18
0.22
0.27
0.33
0.39
0.47
0.56
0.68
1.0
1.5
2.0
2.2
B32671P ... B32673P
Power Factor Correction
Page 3 of 18Please read Cautions and warnings and
Important notes at the end of this document.
Ordering codes and packing units (lead spacing 10 mm)
VR
V DC
VRMS
f1 kHz
V AC
CR
µF
Ordering code
(composition see
below)
Max. dimensions
w×h×l
mm
Ammo
pack
pcs./MOQ
Reel
pcs./MOQ
Untaped
pcs./MOQ
MOQ = Minimum Order Quantity, consisting of 4 packing units.
Further E series, intermediate capacitance values and closer tolerance on request.
Composition of ordering code
+ = Capacitance tolerance code: *** = Packaging code:
J = ±5%
K = ±10%
M = ±20%
289 = Straight terminals, Ammo pack
189 = Straight terminals, Reel
240 = Crimped down to lead spacing 7.5 mm,
Ammo pack
140 = Crimped down to lead spacing 7.5 mm,
Reel
003 = Straight terminals, untaped (lead length
3.2 ±0.3 mm)
000 = Straight terminals, untaped (lead length
61 mm)
450 160 0.10 B32671P4104+*** 4.0 ×9.0 ×13.0 4000 6800 4000
0.15 B32671P4154+*** 4.0 ×9.0 ×13.0 4000 6800 4000
0.18 B32671P4184+*** 5.0 ×11.0 ×13.0 3320 5200 4000
0.22 B32671P4224+*** 5.0 ×11.0 ×13.0 3320 5200 4000
0.27 B32671P4274+*** 5.0 ×11.0 ×13.0 3320 5200 4000
0.33 B32671P4334+*** 6.0 ×12.0 ×13.0 2720 4400 4000
0.39 B32671P4394+*** 6.0 ×12.0 ×13.0 2720 4400 4000
0.47 B32671P4474+*** 6.0 ×14.0 ×13.0 2720 4400 4000
0.68 B32671P4684+*** 7.0 ×16.0 ×13.0 4000
1.0 B32671P4105+*** 8.0 ×17.5 ×13.0 4000
520 200 0.082 B32671P5823+*** 4.0 ×9.0 ×13.0 4000 6800 4000
0.10 B32671P5104+*** 5.0 ×11.0 ×13.0 3320 5200 4000
0.15 B32671P5154+*** 5.0 ×11.0 ×13.0 3320 5200 4000
0.22 B32671P5224+*** 6.0 ×12.0 ×13.0 2720 4400 4000
0.33 B32671P5334+*** 7.0 ×16.0 ×13.0 4000
0.47 B32671P5474+*** 8.0 ×17.5 ×13.0 4000
630 200 0.068 B32671P6683+*** 4.0 ×9.0 ×13.0 4000 6800 4000
0.082 B32671P6823+*** 5.0 ×11.0 ×13.0 3320 5200 4000
0.10 B32671P6104+*** 5.0 ×11.0 ×13.0 3320 5200 4000
0.15 B32671P6154+*** 6.0 ×12.0 ×13.0 2720 4400 4000
0.18 B32671P6184+*** 6.0 ×12.0 ×13.0 2720 4400 4000
0.22 B32671P6224+*** 6.0 ×14.0 ×13.0 2720 4400 4000
0.33 B32671P6334+*** 8.0 ×17.5 ×13.0 4000
0.39 B32671P6394+*** 8.0 ×17.5 ×13.0 4000
B32671P
Power Factor Correction
Page 4 of 18Please read Cautions and warnings and
Important notes at the end of this document.
Ordering codes and packing units (lead spacing 15 mm)
VR
V DC
VRMS
f1 kHz
V AC
CR
µF
Ordering code
(composition see
below)
Max. dimensions
w×h×l
mm
Ammo
pack
pcs./MOQ
Reel
pcs./MOQ
Untaped
pcs./MOQ
MOQ = Minimum Order Quantity, consisting of 4 packing units.
Further E series, intermediate capacitance values and closer tolerance on request.
Composition of ordering code
+ = Capacitance tolerance code: *** = Packaging code:
J = ±5%
K = ±10%
M = ±20%
289 = Straight terminals, Ammo pack
189 = Straight terminals, Reel
255 = Crimped down to lead spacing 7.5 mm,
Ammo pack
155 = Crimped down to lead spacing 7.5 mm,
Reel
003 = Straight terminals, untaped (lead length
3.2 ±0.3 mm)
000 = Straight terminals, untaped (lead length
61 mm)
450 160 0.10 B32672P4104+*** 5.0 ×10.5 ×18.0 4680 5200 4000
0.22 B32672P4224+*** 5.0 ×10.5 ×18.0 4680 5200 4000
0.33 B32672P4334+*** 5.0 ×10.5 ×18.0 4680 5200 4000
0.47 B32672P4474+*** 5.0 ×10.5 ×18.0 4680 5200 4000
0.56 B32672P4564+*** 6.0 ×11.0 ×18.0 3840 4400 4000
0.68 B32672P4684+*** 6.0 ×12.0 ×18.0 3840 4400 4000
1.0 B32672P4105+*** 7.0 ×12.5 ×18.0 3320 3600 4000
1.5 B32672P4155+*** 9.0 ×17.5 ×18.0 2560 2800 2000
2.0 B32672P4205+*** 9.0 ×17.5 ×18.0 2560 2800 2000
2.2 B32672P4225+*** 11.0 ×18.5 ×18.0 2200 1200
520 200 0.15 B32672P5154+*** 5.0 ×10.5 ×18.0 4680 5200 4000
0.22 B32672P5224+*** 5.0 ×10.5 ×18.0 4680 5200 4000
0.33 B32672P5334+*** 6.0 ×11.0 ×18.0 3840 4400 4000
0.47 B32672P5474+*** 7.0 ×12.5 ×18.0 3320 3600 4000
0.68 B32672P5684+*** 8.5 ×14.5 ×18.0 2720 2800 2000
1.0 B32672P5105+*** 9.0 ×17.5 ×18.0 2560 2800 2000
1.5 B32672P5155+*** 11.0 ×18.5 ×18.0 2200 1000
630 200 0.15 B32672P6154+*** 5.0 ×10.5 ×18.0 4680 5200 4000
0.22 B32672P6224+*** 6.0 ×11.0 ×18.0 3840 4400 4000
0.33 B32672P6334+*** 7.0 ×12.5 ×18.0 3320 3600 4000
0.47 B32672P6474+*** 8.0 ×14.0 ×18.0 2920 3000 2000
0.68 B32672P6684+*** 9.0 ×17.5 ×18.0 2560 2800 2000
1.0 B32672P6105+*** 11.0 ×18.5 ×18.0 2200 1000
B32672P
Power Factor Correction
Page 5 of 18Please read Cautions and warnings and
Important notes at the end of this document.
Ordering codes and packing units (lead spacing 22.5 mm)
VR
V DC
VRMS
f1 kHz
V AC
CR
µF
Ordering code
(composition see
below)
Max. dimensions
w×h×l
mm
Ammo
pack
pcs./MOQ
Reel
pcs./MOQ
Untaped
pcs./MOQ
MOQ = Minimum Order Quantity, consisting of 4 packing units.
Further E series, intermediate capacitance values and closer tolerance on request.
Composition of ordering code
+ = Capacitance tolerance code: *** = Packaging code:
J = ±5%
K = ±10%
M = ±20%
289 = Straight terminals, Ammo pack
189 = Straight terminals, Reel
003 = Untaped (lead length 3.2 ±0.3 mm)
000 = Untaped (lead length 61 mm)
450 160 1.0 B32673P4105+*** 6.0 ×15.0 ×26.5 2720 2800 2880
1.5 B32673P4155+*** 7.0 ×16.0 ×26.5 2320 2400 2520
2.2 B32673P4225+*** 8.5 ×16.5 ×26.5 1920 2000 2040
520 200 0.47 B32673P5474+*** 6.0 ×15.0 ×26.5 2720 2800 2880
0.56 B32673P5564+*** 6.0 ×15.0 ×26.5 2720 2800 2880
0.68 B32673P5684+*** 6.0 ×15.0 ×26.5 2720 2800 2880
1.0 B32673P5105+*** 7.0 ×16.0 ×26.5 2320 2400 2520
1.5 B32673P5155+*** 10.5 ×16.5 ×26.5 1560 1600 2160
2.2 B32673P5225+*** 10.5 ×20.5 ×26.5 2160
630 200 0.33 B32673P6334+*** 6.0 ×15.0 ×26.5 2720 2800 2880
0.47 B32673P6474+*** 6.0 ×15.0 ×26.5 2720 2800 2880
0.56 B32673P6564+*** 6.0 ×15.0 ×26.5 2720 2800 2880
0.68 B32673P6684+*** 7.0 ×16.0 ×26.5 2320 2400 2520
1.0 B32673P6105+*** 8.5 ×16.5 ×26.5 1920 2000 2040
1.5 B32673P6155+*** 10.5 ×18.5 ×26.5 1560 1600 2160
2.2 B32673P6225+*** 12.0 ×22.0 ×26.5 1800
B32673P
Power Factor Correction
Page 6 of 18Please read Cautions and warnings and
Important notes at the end of this document.
Technical data
Reference standard: IEC 60384-16. All data given at T = 20 °C, otherwise is specified.
Operating temperature
range
Max. operating temperature Top, max
Upper category temperature Tmax
Lower category temperature Tmin
Rated temperature TR
+125 °C
+110 °C
55 °C
+85 °C
Dissipation factor tan δ
(in 10-3)at20°C
(upper limit values)
1 kHz
10 kHz
100 kHz
1.0
2.5
25.0
Insulation resistance Rins
at 100 V or time constant
τ= CRRins at 20 °C,
rel. humidity 65%
(minimum as-delivered
values)
30 G(CR0.33 µF)
10000 s (CR> 0.33 µF)
DC test voltage 1.4 VR,2s
Category voltage VC
(continuous operation with
VDC or VAC atf1 kHz)
TA(°C) DC voltage derating AC voltage derating
TA85
85 <TA110
VC= VR
VC= VR(165 Top)/80
VC,RMS = VRMS
VC,RMS = VRMS (165 Top)/80
Operating voltage Vop for
short operating periods
(VDC or VAC atf1 kHz)
Top (°C) DC voltage (max. hours) AC voltage (max. hours)
Top 100
100 <Top 125
Vop = 1.1 VC(1000 h)
Vop = 1.0 VC(1000 h)
Vop = 1.0 VC,RMS (1000 h)
Vop = 1.0 VC,RMS (1000 h)
Reliability:
Failure rate λ
Service life tSL
24 fit (110-7/h) at 0.5 VR,40°C
200000 h at 0.5 VR,85°C
For conversion to other operating conditions and temperatures, refer
to chapter "Reliability", page .
Failure criteria:
Total failure Short circuit or open circuit
Failure due to variation
of parameters
Capacitance change C/C
Dissipation factor tan δ
Insulation resistance Rins
Or time constant τ
> 10%
>4×upper limit values
< 150 M(CR0.33 µF)
< 50 s (CR0.33 µF)
B32671P ... B32673P
Power Factor Correction
Page 7 of 18Please read Cautions and warnings and
Important notes at the end of this document.
Pulse handling capability
"dV/dt" represents the maximum permissible voltage change per unit of time for non-sinusoidal
voltages, expressed in V/µs.
"k0" represents the maximum permissible pulse characteristic of the waveform applied to the
capacitor, expressed in V2/µs.
Note:
The values of dV/dt and k0provided below must not be exceeded in order to avoid damaging the
capacitor. These parameters are given for isolated pulses in such a way that the heat generated
by one pulse will be completely dissipated before applying the next pulse. For a train of pulses,
please refer to the curves of permissible AC voltage-current versus frequency.
dV/dt values
Lead spacing 10 mm 15 mm 22.5 mm
VRVRMS
V DC V AC dV/dt in V/µs
450 160 140 120 100
520 200 200 160 110
630 200 250 180 130
k0values
Lead spacing 10 mm 15 mm 22.5 mm
VRVRMS
V DC V AC k0in V2/µs
450 160 126000 108000 90000
520 200 208000 166000 114000
630 200 315000 226000 163000
Impedance Z versus frequency f (typical values)
B32671P ... B32673P
Power Factor Correction
Page 8 of 18Please read Cautions and warnings and
Important notes at the end of this document.
Permissible AC voltage VRMS versus frequency f (for sinusoidal waveforms TA100 °C)
For TA> 100 °C, please use derating factor Ft.
Lead spacing 10 mm
450 V DC/160 V AC 520 V DC/200 V AC
630 V DC/200 V AC
B32671P
Power Factor Correction
Page 9 of 18Please read Cautions and warnings and
Important notes at the end of this document.
Permissible AC voltage VRMS versus frequency f (for sinusoidal waveforms TA100 °C)
For TA> 100 °C, please use derating factor Ft.
Lead spacing 15 mm
450 V DC/160 V AC 520 V DC/200 V AC
630 V DC/200 V AC
B32672P
Power Factor Correction
Page 10 of 18Please read Cautions and warnings and
Important notes at the end of this document.
Permissible AC voltage VRMS versus frequency f (for sinusoidal waveforms TA100 °C)
For TA> 100 °C, please use derating factor Ft.
Lead spacing 22.5 mm
450 V DC/160 V AC 520 V DC/200 V AC
630 V DC/200 V AC
B32673P
Power Factor Correction
Page 11 of 18Please read Cautions and warnings and
Important notes at the end of this document.
Permissible AC current IRMS versus frequency f (for sinusoidal waveforms TA100 °C)
For TA> 100 °C, please use derating factor Ft.
Lead spacing 10 mm
450 V DC/160 V AC 520 V DC/200 V AC
630 V DC/200 V AC
B32671P
Power Factor Correction
Page 12 of 18Please read Cautions and warnings and
Important notes at the end of this document.
Permissible AC current IRMS versus frequency f (for sinusoidal waveforms TA100 °C)
For TA> 100 °C, please use derating factor Ft.
Lead spacing 15 mm
450 V DC/160 V AC 520 V DC/200 V AC
630 V DC/200 V AC
B32672P
Power Factor Correction
Page 13 of 18Please read Cautions and warnings and
Important notes at the end of this document.
Permissible AC current IRMS versus frequency f (for sinusoidal waveforms TA100 °C)
For TA> 100 °C, please use derating factor Ft.
Lead spacing 22.5 mm
450 V DC/160 V AC 520 V DC/200 V AC
630 V DC/200 V AC
B32673P
Power Factor Correction
Page 14 of 18Please read Cautions and warnings and
Important notes at the end of this document.
Maximum AC voltage (VRMS), current (IRMS) vs. frequency and temperature for TA> 100 ºC
The graphs described in the previous section for the permissible AC voltage (VRMS) or current
(IRMS) vs. frequency are given for a maximum ambient temperature TA100 ºC. In case of higher
ambient temperatures (TA), the self-heating (T) of the component must be reduced to avoid that
temperature of the component (Top= TA+T) reaches values above maximum operating
temperature.The factor FTshall be applied in the following way:
And FTis given by the following curve:
B32671P ... B32673P
Power Factor Correction
Page 15 of 18Please read Cautions and warnings and
Important notes at the end of this document.
Testing and Standards
Test Reference Conditions of test Performance
requirements
Electrical
Parameters
IEC 60384-16 Voltage proof, 1.4 VR, 1 minute
Insulation resistance, RINS
Capacitance, C
Dissipation factor, tan δ
Within specified limits
Robustness of
terminations
IEC 60068-2-21 Tensile strength (test Ua1) Capacitance and tan δ
within specified limitsWire diameter Tensile
force
0.5 < d10.8 mm 10 N
Resistance to
soldering heat
IEC 60068-2-20,
test Tb,
method 1A
Solder bath temperature at
260 ±5°C, immersion for
10 seconds
C/C02%
Itan δl0.001
Rapid change of
temperature
IEC 60384-16 TA= lower category temperature
TB= upper category temperature
Five cycles, duration t = 30 min.
IC/C0I2%
Itan δI0.002
RINS 50% of initial limit
Vibration IEC 60384-16 Test FC: vibration sinusoidal
Displacement: 0.75 mm
Accleration: 98 m/s2
Frequency: 10 Hz ... 500 Hz
Test duration: 3 orthogonal axes,
2 hours each axe
No visible damage
Bump IEC 60384-16 Test Eb: Total 4000 bumps with
390 m/s2mounted on PCB
6 ms duration
No visible damage
IC/C0I2%
Itan δI0.001
RINS 50% of initial limit
Climatic
sequence
IEC 60384-16 Dry heat Tb / 16 h.
Damp heat cyclic, 1st cycle
+55°C / 24h / 95% ... 100% RH
Cold Ta / 2h
Damp heat cyclic, 5 cycles
+55°C / 24h / 95% ... 100% rh
No visible damage
IC/C0I2%
Itan δI0.001
RINS 50% of initial limit
Damp Heat
Steady State
IEC 60384-16 Test Ca
40 °C / 93% RH / 56 days
No visible damage
IC/C0I3%
Itan δI0.003
RINS 50% of initial limit
High
temperature
high humidity
with load
60 °C / 95% RH / 1000 hours with
VR, DC
No visible damage
IC/C0I10%
Itan δI0.004
RINS 50% of initial limit
B32671P ... B32673P
Power Factor Correction
Page 16 of 18Please read Cautions and warnings and
Important notes at the end of this document.
Endurance A 85 °C/ 1.1 VR/ 1000 hours No visible damage
IC/C0I5%
Itan δI0.004
RINS 50% of initial limit
Endurance B 110 °C/ 1.1 VC/ 1000 hours No visible damage
IC/C0I10%
Itan δI0.004
RINS 50% of initial limit
Endurance C 125 °C/ 1.1 VC/ 1000 hours No visible damage
IC/C0I10%
Itan δI0.004
RINS 50% of initial limit
Endurance D 85 °C/ VR+4ARMS,1000 KHz/ 1000
hours
No visible damage
IC/C0I10%
Itan δI0.004
RINS 50% of initial limit
B32671P ... B32673P
Power Factor Correction
Page 17 of 18Please read Cautions and warnings and
Important notes at the end of this document.
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical re-
quirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application.
As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar
with them than the customers themselves. For these reasons, it is always ultimately incum-
bent on the customer to check and decide whether an EPCOS product with the properties de-
scribed in the product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of electronic components or
failure before the end of their usual service life cannot be completely ruled out in the
current state of the art, even if they are operated as specified. In customer applications
requiring a very high level of operational safety and especially in customer applications in
which the malfunction or failure of an electronic component could endanger human life or
health (e.g. in accident prevention or lifesaving systems), it must therefore be ensured by
means of suitable design of the customer application or other action taken by the customer
(e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by
third parties in the event of malfunction or failure of an electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as hazardous). Useful information on this will be found in our Ma-
terial Data Sheets on the Internet (www.epcos.com/material). Should you have any more de-
tailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order. We also
reserve the right to discontinue production and delivery of products. Consequently, we
cannot guarantee that all products named in this publication will always be available. The
aforementioned does not apply in the case of individual agreements deviating from the fore-
going for customer-specific products.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current ver-
sion of the "General Terms of Delivery for Products and Services in the Electrical In-
dustry" published by the German Electrical and Electronics Industry Association
(ZVEI).
7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CeraLink, CeraPlas, CSMP, CSSP,
CTVS, DeltaCap, DigiSiMic, DSSP, FilterCap, FormFit, MiniBlue, MiniCell, MKD, MKK,
MLSC, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, SIFERRIT, SIFI,
SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K, TFAP,
ThermoFuse, WindCap are trademarks registered or pending in Europe and in other coun-
tries. Further information will be found on the Internet at www.epcos.com/trademarks.
Important notes
Page 18 of 18