2. CHARACTERS:
DIELECTRIC STRENGTH
1. SCOPE:
THIS SPECIFICATION DEFINES THE ELECTRICAL AND MECHANICAL CHARACTERISTICS
OF THE DC BRUSHLESS BLOWER FLOW FAN.
BSB01703HA3-00CAJ
MAX. AIR PRESSURE
(AT ZERO AIRFLOW)
0.007 (MIN. 0.006) M3/MIN.
0.230 (MIN. 0.173) CFM
MAX. AIR FLOW
(AT ZERO STATIC PRESSURE)
4.630 (MIN. 2.604) mmH2O
0.182 (MIN. 0.103) inchH2O
ITEM DESCRIPTION
RATED VOLTAGE
0.18 (MAX 0.3) W
0.06 (MAX 0.10) A
SAFETY CURRENT ON LABEL: 0.10 A
INPUT POWER(AVG.)
3.0V
SPEED 12000±25%R.P.M.
Specification For Approval
Customer P/N :
JUL.06 2019
BSB01703HA3-00
Delta model no. :
STD
DC FAN
Sample issue date :
Delta Safety Model No.:
01
OPERATION VOLTAGE 2.0 - 3.5 VDC
PAGE 1
(continued)
ACOUSTICAL NOISE (AVG.)
TEST DISTANCE : 0.3M 26.5 (MAX. 32.5) dB-A
INSULATION TYPE UL: CLASS A
INSULATION STRENGT
5 mA MAX. AT 500 VAC 50/60 Hz ONE MINUTE,
(BETWEEN FRAME AND (+) TERMINAL)
10 MEG OHM MIN. AT 500 VDC
(BETWEEN FRAME AND (+) TERMINAL)
THE PEAK VALUE NEED MEASURE BY OSCILLOSCOPE.
# THE MAX VALUE OF CONSUMING CURRENT DOES NOT REPRESENT THE PEAK VALUE,
INPUT CURRENT(AVG.)
PART NO:
DELTA MODEL:
NOTES:
1. ALL READINGS ARE MEASURED AFTER STABLY WARMING UP
THROUGH 10 MINUTES.
2. STANDARD AIR PROPERTY IS AIR AT (Td) 25°C TEMPERATURE, (RH) 65%
RELATIVE HUMIDITY , AND (Pb) 760 mmHg BAROMETRIC PRESSURE.
3. THE VALUES WRITTEN IN PARENS , ( ), ARE LIMITED SPEC.
4. ACOUSTICAL NOISE MEASURING CONDITION:
LIFE EXPECTANCE (L10)
(AT LABEL VOLTAGE)
ROTATION
BSB01703HA3-00CAJ
LOCKED PROTECTION
30,000 HOURS CONTINUOUS OPERATION AT 40 °
C WITH 15 ~ 65 %RH.
CLOCKWISE VIEW FROM NAME PLATE SIDE
THE FAN WILL SHUT DOWN WHEN LOCKED
ROTOR.
DISTANCE OF ONE METER FROM THE FAN INTAKE.
NOISE IS MEASURED AT RATED VOLTAGE IN FREE AIR IN ANECHOIC
CHAMBER WITH B & K SOUND LEVEL METER WITH MICROPHONE AT A
PAGE 2
PART NO:
DELTA MODEL:
PAGE 3
3.MECHANICAL:
3-1. DIMENSIONS-------------------------------------------- SEE DIMENSIONS DRAWING
3-2. FRAME---------------------------------------------------------------------- PLASTIC UL: 94V-0
3-3. PILLOW---------------------------------------------------------------------- PLASTIC UL: 94V-0
3-5. BEARING SYSTEM------------------------------------------------------ SLEEVE BEARINGS
3-6. WEIGHT--------------------------------------------------------------------- 1.0 GRAMS(REF.)
4. ENVIRONMENTAL:
7. PRODUCTION LOCATION
4-1. OPERATING TEMPERATURE------------------------------- -10 TO +60 DEGREE C
4-2. STORAGE TEMPERATURE---------------------------------- -40 TO +75 DEGREE C
4-3. OPERATING HUMIDITY---------------------------------------------------- 5 TO 90 % RH
4-4. STORAGE HUMIDITY------------------------------------------------------ 5 TO 95 % RH
5. PROTECTION:
5-1. LOCKED ROTOR PROTECTION
7-1. PRODUCTS WILL BE PRODUCED IN CHINA OR THAILAND.
6. RE OZONE DEPLETING SUBSTANCES:
6-1. NO CONTAINING PBBs, PBBOs, CFCs, PBBEs, PBDPEs AND HCFCs.
BSB01703HA3-00CAJ
3-4. IMPELLER------------------------------------------------------------------ PLASTIC UL: 94V-0
IMPEDANCE OF MOTOR WINDING PROTECTS MOTOR FROM FIRE IN
96 HOURS OF LOCKED ROTOR CONDITION AT THE RATED VOLTAGE.
(THE CONTACT OF HALOGEN LESS THAN 1500 PPM FOR USING EDX ...ETC)
(THE CONTACT OF HALOGEN LESS THAN 1500 PPM FOR USING EDX ...ETC)
(THE CONTACT OF HALOGEN LESS THAN 1500 PPM FOR USING EDX ...ETC)
5-2. IP55 PROTECTION
8. P & Q CURVE:
PAGE 4
BSB01703HA3-00CAJ
9. DIMENSION DRAWING:
BSB01703HA3-00CAJ
PAGE 5
2. THIS PRODUCT IS RoHS COMPLIANT.
3. DELTA'S RESTRICTIONS ON HALOGEN APPLY ONLY TO BROMINATED AND
CHLORINATED COMPOUNDS. NO OTHER HALOGEN IS RESTRICTED.
SUBSTANCES RESTRICTIONS FOR HALOGEN-FREE(INCLUDE FAN PLASTIC
PARTS, PWB BOARD, IC, ELECTRICAL MATERIALS & CABLE ASSY),
b. CHLORINE(Cl) < 900 PPM
a. BROMINE(Br) < 900 PPM,
c. (Br) + (Cl) < 1500 PPM.
PIN 3: BLACK WIRE ---(-)
1. HOUSING: ACES 50375-0031N-001 OR EQUIVALENT
PIN 2: YELLOW WIRE ---(FG)
PIN 1: RED WIRED ---(+)
LEAD WIRE: UL10064 AWG#32
PART NO:
DELTA MODEL:
PAGE 6
BSB01703HA3-00CAJ
1.

Deltawillnotguaranteetheperformanceoftheproductsiftheapplicationcondition
fallsoutsidetheparameterssetforthinthespecification.
thisspecificationisrequired.
3.

Pleaseexercisecautionwhenhandlingfans.Damagemaybecausedwhenpressureis
appliedtotheimpeller,ifthefansarehandledbytheleadwires,orifthefanwas
hard-droppedtotheproductionfloor.
4.

Exceptaspertainstosomespecialdesigns,thereisnoguaranteethattheproductswill
befreefromanysuchsafetyproblemsorfailuresascausedbytheintroductionof
powder,dropletsofwaterorencroachmentofinsectintothehub.
5.

Theabove-mentionedconditionsarerepresentativeofsomeuniqueexamplesandviewed
asthefirstpointofreferencepriortoallotherinformation.
6.
I
tisveryimportanttoestablishthecorrectpolaritybeforeconnectingthefantothe
powersource.Positive(+)andNegative(-).Damagemaybecausedtothefansif
connectioniswithreversepolarity,ifthereisnofoolproofmethodtoprotectagainst
sucherrorspecificallymentionedinthisspec.
7.

Deltafanswithoutspecialprotectionarenotsuitablewhereanycorrosivefluidsare
introducedtotheirenvironment.
8.

Pleaseensureallfansarestoredaccordingtothestoragetemperaturelimitsspecified.
Donotstorefansinahighhumidityenvironment.Wehighlyrecommendperformance
testingisconductedbeforeshipping,ifthefanshavebeenstoredover6months.
9.

NotallfansareprovidedwiththeLockRotorProtectionfeature.Ifyouimpairthe
rotationoftheimpellerforthefansthatdonothavethisfunction,theperformance
ofthosefanswillleadtofailure.
10.Pleasebecautiouswhenmountingthefan.Incorrectmountingoffansmaycause
excessresonance,vibrationandsubsequentnoise.
11.
Itisimportanttoconsidersafetywhentestingthefans.Asuitablefanguardshouldbe
fittedtothefantoguardagainstanypotentialforpersonalinjury.
12.
Exceptwherespecificallystated,alltestsarecarriedoutatroom(ambient)temperature
andrelativehumidityconditionsof25oC,65%RH.Thetestvalueisonlyforfan
performanceitself.
13.
Becertaintoconnectan“4.7µForgreater”capacitortothefanexternallywhen
theapplicationcallsforusingmultiplefansinparallel,toavoidanyunstablepower.
Application Notice
2.AwrittenrequestshouldbesubmittedtoDeltapriortoapprovalifdeviationfrom
Doc. No: FMBG-ES Form 001 Rev. 0001 Date: June 24, 2009