Products and specifications subject to change without notice.
Order/Technical Support – Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
5/18
"Adjustable stop" series position detectors
To order, specify :Other information
Part numbers
Example : "Adjustable stop" series position
detectors - 81 923 001
1
Standard products
Standard products,
non stocked
Operating pressure psi (bar)
Orifice diameter inches(mm)
Flow at 90 psi (6 bar) cfm(NI/min)
Actuation force at 90 psi (6 bar) oz (N)
Circuit function: NC
Max. load: without shock lbs (daN)
Will stop a 2 1/2" Ø cylinder @ 90 psi: (6 bar) supply
Operating temperature °F (°C)
Mechanical life cycles
Weight (grams)
Actuation positions
PA : Operating position (max output Cv) inches(mm)
PFC: End of travel position inches(mm)
PR : Rest position inches(mm)
PO : Mid-point closed
(no exhaust, no outlet)
PRT : Release position
(max. exhaust kV)
inches(mm)
inches(mm)
Push-in connection for semi-rigid tubing
(NFE 49100)
81 923 001
Barb for tube with 5/32” (4mm) O.D. x
0.106” (2.7mm) I.D.
81 921 505
Push-in connector for tube with 5/32”
(4mm) O.D.
2 > 120 (0.1> 8)
0.079” (2)
5(130)
56 (16)
●
2,200 (1000)
●
+20>+120 (-5>+ 50)
10 million
27
0.016 (0.4)
0(0)
0.035 (0.9)
0.059 (1.5)
0.118 (3)
2 > 120 (0.1> 8)
0.106” (2.7)
7(200)
94 (21)
●
2,200 (1000)
●
+20>+120 (-5>+ 50)
10 million
90
0.028 (0.7)
0(0)
0.040 (1)
0.059 (1.5)
0.118 (3)
Part numbers
Characteristics
Symbol
Dimensions
81 923 001 81 921 505 Mounting
Exhaust
Poppet
Black barb
Principle of operation
This should be as close
as possible to the
plunger
1/2” dia. mounting hole
threaded hole
M12
(Ø12.5)
1
Actuation positions :
PA : Operating position (max output Cv)
PFC : End of travel position
PO : Mid-position closed
(no exhaust, no outlet)
PRT : Release position
(max exhaust Cv)
PR : Rest position
Use (metric) for critical data.
O.106"(2.7)