http://www.tracopower.com Page 2 of 3
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
DC/DC Converters
THD 15 Series 15 Watt
Input Specifications
Input current (no load) 24 Vin models: 50 mA typ..
48 Vin models: 30 mA typ.
Input current (full load) 24 Vin; 3.3 Vout models: 570 mA typ.
24 Vin; other output models: 730 mA typ.
48 Vin; 3.3 Vout models: 280 mA typ.
48 Vin; other output models: 360 mA typ.
Start-up voltage / 24 Vin models: 17 VDC /16.5 VDC
under voltage shut down 48 Vin models: 34.0 VDC /32.5 VDC
Surge voltage 24 Vin models: 50 V max..
(100 msec. max.) 48 Vin models: 100 V max.
Conducted noise (input) EN 55022 level A, FCC part 15, level A
(with external input capacitor, see Note 1)
Output Specifications
Voltage set accuracy ± 1 %
Regulation – Input variation Vin min. to Vin max ± 0.5% max.
– Load variation 10 – 100 %
single output models: ± 0.5 % max.
dual output models balanced: ± 2.0 % max.
dual output models unbalanced: ± 5.0 % max.
Ripple and noise 100 mVpk-pk max.
(20 MHz Bandwidth) (with external output capacitor, see Note 1)
Temperature coefficient ± 0.02 % /K
Output current limitation >105% of Iout max., foldback
Short circuit protection indefinite (automatic recovery)
Start-up time 30ms max.
Max. capacitive load 1200µF
General Specifications
Temperature ranges – Operating –25 °C ... +71°C
– Derating 2.5%/K above 50
– Case temperature +100 °C max.
– Storage –40 °C ... +110 °C
Humidity (non condensing) 85 % rel H max.
Reliability, calculated MTBF (MIL-HDBK-217 F) > 190’000h @ +25°C
Isolation voltage – Input/Output 1’500 VDC
Isolation capacity – Input/Output 235 pF typ.
Isolation resistance – Input/Output (500 VDC) >100 M Ohm
Switching frequency (fixed) 330 kHz typ. (Pulse width modulation PWM)
Safety standards UL 60950, EN 60950, IEC 60950
compliance up to 60 VDC input voltage (SELV limit)
Safety approvals UL/cUL pending
Remote On/Off – ON: open circuit on pin RC
– OFF: short circuit between pin RC and pin –Vin