ZTX653DCSM
Document Number 3517
Issue 2
Semelab plc. Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail: sales@semelab.co.uk Website: http://www.semelab.co.uk
Parameter Test Conditions Min. Typ. Max. Unit
Parameter Test Conditions Min. Typ. Max. Unit
IC= 100µA
IC= 10mA
IE= 100µA
VCB = 100V
TC= 100°C
VEB = 4V
IC= 500mA IB= 50mA*
IC= 1.0A IB= 100mA*
IC= 2A IB= 200mA*
IC= 1.0A IB= 100mA*
IC= 1.0A VCE = 2V*
IC= 50mA VCE = 2V*
IC= 500mA VCE = 2V*
IC= 1.0A VCE = 2V*
IC= 2A VCE = 2V*
ELECTRICAL CHARACTERISTICS (TA= 25°C unless otherwise stated)
V(BR)CBO Collector – Base Breakdown Voltage
V(BR)CEO Collector – Emitter Breakdown Voltage
V(BR)EBO Emitter – Base Breakdown Voltage
ICBO Collector – Cut-off Current
IEBO Emitter Cut-off Current
VCE(sat) Collector – Emitter Saturation Voltage
VBE(sat) Base – Emitter Saturation Voltage
VBE(on) Base – Emitter Turn-On Voltage
HFE DC Current Gain
120
100
5
0.1
10
0.1
0.2 0.3
0.35 0.5
0.8 1.0
1.0 1.3
0.95 1.2
70 200
100 200 300
55 110
25 55
V
µA
V
—
fTTransition Frequency
Cobo Output Capacitance
Ton Switching Times
Toff Switching Times
IC= 100mA VCE = 5V f = 100MHz
VCB = 10V f = 1.0MHz
IC= 500mA VCC = 10V
IB1=IB2=50mA
140 175
30
80
1200
MHz
pF
ns
DYNAMIC CHARACTERISTICS (TA= 25°C unless otherwise stated)
* Pulse test tp = 300ms , δ ≤ 2%
Semelab Plc reserves the right to change test conditions, parameter limits and package dimensions without notice. Information furnished by Semelab is believed
to be both accurate and reliable at the time of going to press. However Semelab assumes no responsibility for any errors or omissions discovered in its use.
Semelab encourages customers to verify that datasheets are current before placing orders.