D1U54P-W-450-12-HxxC Series 54mm 1U Front End AC-DC Power Supply Converter PRODUCT OVERVIEW The D1U54P-W-450-12-HAxC series power modules are very high efficiency, 450 watt power factor corrected front end supplies, with a 12Vdc main output and standby output. An active (digital) current share characteristic is provided to allow units to operate in parallel and share load current. The power supply may be hot plugged; recovers from overtemperature faults, and has status LEDs on the front panel in addition to hardware signal logic and PMBusTM status signals. The low profile 1U package and 14.8W/cubic inch power density make them ideal for delivering reliable, efficient power to networking equipment, workstations, storage systems and other 12Vdc distributed power architectures. ORDERING GUIDE FEATURES Part Number Power Output 90-264Vac Main Output D1U54P-W-450-12- HA3C D1U54P-W-450-12- HB3C D1U54P-W-450-12- HA4C D1U54P-W-450-12- HB4C 450W 12Vdc INPUT CHARACTERISTICS Parameter Conditions Input Source Voltage Input Source Turn-on Input Ramp up Turn-off Input Ramp down Maximum current at 450W; 100-240Vac Inrush Current Cold start between 0 to 200msec At 230Vac, 100% load Power Factor At 230Vac, 50% load At 230Vac 20% load At 230Vac 50% load Efficiency At 230Vac 100% load 450W output power 12Vdc main output 5Vdc & 12Vdc standby output options <1U height: 54.5mm x 228.6mm x 40mm (2.15" x 9.0" x 1.57") Card Edge DC Output and Signal I/O Connector IEC 60320-C14 AC Inlet 14.8 Watts per cubic inch density N+1 redundancy capable Active (digital) current sharing on 12Vdc main output; both outputs include ORING FET circuit Overvoltage, Overcurrent, Overtemperature protection Internal cooling fan (variable speed) PMBusTM/I2C interface with status indicators RoHS compliant OUTPUT VOLTAGE CHARACTERISTICS Nominal Parameter Output Voltage Output Set Point Accuracy Two Year Warranty Line and Load Regulation 2 1, 2 12V 5VSB 12VSB Available now at: www.murata-ps.com/en/3d/acdc.html Ripple Voltage & Noise Output Current Range Load Capacitance Nominal Output Voltage Line and Load Regulation 3 Ripple Voltage & Noise13 Output Current Load Capacitance Nominal Output Voltage Line and Load Regulation 3 Ripple Voltage & Noise13 Output Current Load Capacitance Min. 90 47 74 70 Standby Output 5Vdc 12Vdc 5Vdc 12Vdc Nom. 100/240 50/60 Airflow Front to Back Back to front Max. 264 63 84 80 6 Units Vac Hz Arms 20 Apk Vac 0.96 0.95 W/VA 90 94 91 Conditions 50% load; Tamb =25C Setpoint; temperature; line and load 20MHz Bandwidth % Min. 11.96 Typ. Max. Units 12.00 12.04 Vdc -1.0% +1.5 % 0 500 120 37.5 4000 mV p-p A F 5.24 75 2 1000 Vdc mV p-p A F 12.3 120 1 1000 Vdc mV p-p A F 5.0 4.76 20MHz Bandwidth 0 250 12.0 11.7 20MHz Bandwidth 0 250 Ripple and noise are measured with 0.1 F of ceramic capacitance and 10 F of tantalum capacitance on each of the power supply outputs. A short coaxial cable to the measurement `scope input, is used. Minimum Load of 1.75A 3 Minimum load of 0.28A 1 2 Certificate and Test Report www.murata-ps.com/support D1U54P-W-450-12-HXXC.A04 Page 1 of 9 D1U54P-W-450-12-HxxC Series 54mm 1U Front End AC-DC Power Supply Converter OUTPUT CHARACTERISTICS Parameter Conditions Startup Time Current sharing accuracy (main 12Vdc output) Transient Response (Single transient, main 12Vdc output) Transient Response (Single transient, Standby output) Hot Swap Transients Holdup Time (Total Effective Hold Up - See Timing Waveforms) ENVIRONMENTAL CHARACTERISTICS Parameter Storage Temperature Range Operating Temperature Range Operating Humidity Storage Humidity AC ramp up > 10% load (* % total Current) Load step of 50% max. load, > 2.5A load, 1A/s slew rate Recovery Time to within 1% Vnom Load step of 50% max. load, > 10% Max load load, 1A/s slew rate Recovery Time to within 1% Vnom Min. Typ. Max. Units -5 3 +5 s *% -5 +5 % 2 ms -5 Conditions 90V-264Vac, 450W Noncondensing; +45C Min. -40 -5 5 5 25C, 50%load 30G non-operating Sine sweep; 5-200Hz, 2G; random vibration, 5-500Hz, 1.11G Per Telcordia SR-332 Issue 3 M1C3 at 40C Operational Vibration MTBF (Target) Safety Approval Standards (Planned; Pending Submission) Input Fuse Weight +5 12 Typ. Max. 70 50 90 95 3000 Altitude (without derating at 40C) Acoustic noise levels Shock % ms % ms 2 -5 Full AC Input Source Range; 100% load +5 45 Units C % m 50 dB 520K hrs CAN/CSA C22.2 No 60950-1: 2007, A2: 2014 UL 60950-1-2014 IEC60950-1:2005+A2:2013 EN 60950-1:2006+A2:2013 BSMI: CNS14336-1 (1999/09/30), CNS13438 (1995/06/01) CCC: GB4943.1-2011; GB/T9254-2008; GB17625.1-2012 Power Supply has internal 8A/250V fast blow fuse on the AC line input 1.51 lbs (0.685 kg) PROTECTION CHARACTERISTICS Output 12V Parameter Conditions Overtemperature (intake) Overvoltage Autorestart with 4C hysteresis for recovery (warning issued at 70C) Latching The output shall shutdown when an overcurrent condition is detected. It will auto restart after 1sec; however if the overcurrent condition is redetected the output will once again shutdown. The output will once again re-start, however if the overcurrent condition persists it will latch of after the fifth unsuccessful attempt. To reset the latch it will be necessary to toggle the PS_ON_L signal or recycle the incoming DC source. Overcurrent (target) Overvoltage 5VSB Overcurrent Over-Voltage 12VSB Over-Current Latching The output shall shutdown when an overcurrent is detected. It will auto restart after 2sec; however if the overcurrent is re-detected the output will once again shutdown. This cycle will occur indefinitely while the overcurrent condition persists. Latching; toggle PS_ON or recycle DC input to reset The output shall shutdown when an overcurrent is detected. It will auto restart after 2sec; however if the overcurrent is re-detected the output will once again shutdown. This cycle will occur indefinitely while the overcurrent condition persists Min. Typ. Max. Units 13.0 14.5 C Vdc 40 50 Adc 5.4 6.0 Vdc 2.1 3.0 Adc 13.0 14.5 Vdc 1.2 2 Adc 75 www.murata-ps.com/support D1U54P-W-450-12-HXXC.A04 Page 2 of 9 D1U54P-W-450-12-HxxC Series 54mm 1U Front End AC-DC Power Supply Converter ISOLATION CHARACTERISTICS Parameter Conditions Input to Output - Reinforced Input to Chassis - Basic Output to Chassis Insulation Safety Rating Isolation Min. 3000 1500 500 Typ. Max. Units Vrms Vrms Vdc EMISSIONS AND IMMUNITY Characteristic Standard Compliance Input Current Harmonics Voltage Fluctuation and Flicker IEC/EN 61000-3-2 IEC/EN 61000-3-3 Complies Complies Conducted Emissions FCC 47 CFR Part 15 CISPR 22/EN55022 Class A with 6dB margin ESD Immunity Radiated Field Immunity IEC/EN 61000-4-2 IEC/EN 61000-4-3 Level 4 criteria A Level 3 criteria B Electrical Fast Transients/Burst Immunity IEC/EN 61000-4-4 Level 3 criteria A Surge Immunity IEC/EN 61000-4-5 1. EN61000-4-5, Lev. 3 (Com. Mode: 2kV, 12, Diff. Mode: 1kV, 2), criteria A 1 2. GR-1089-CORE (NEBS) Level 1 Table 4-30 (Com/Diff. Mode: 2kV, 2) 1 RF Conducted Immunity Magnetic Field Immunity IEC/EN 61000-4-6 IEC/EN 61000-4-8 Level 3 criteria A 3 A/m criteria B 230Vin, 80% load, Phase 0, Dip 100% Duration 10ms (A) 230Vin, 50% load, Phase 0, Dip 100% Duration 20ms (VSB:A, V1:B) Voltage Dips, Interruptions IEC/EN 61000-4-11 230Vin, 100% load, Phase 0, Dip 100% Duration > 20ms (VSB, V1:B) 1 tests are performed at 50% maximum load, and with minimum capacitance at both outputs STATUS INDICATORS AND CONTROL SIGNALS INPUT LED Condition Input Voltage Present Input Voltage fault or warning Input off POWER LED Condition Fault concurrent indication via PMBus Status_x registers Warning, concurrent indication via PMBus Status_x registers Standby, 12Vdc Main output off, Vstby On Power Good 12Vdc Main output on, Vstby On Power Off 12Vdc Main output off, Vstby Off LED Status Solid Green Blinking Green Off LED Status Solid Amber Blinking Amber Blinking Green Solid Green Off www.murata-ps.com/support D1U54P-W-450-12-HXXC.A04 Page 3 of 9 D1U54P-W-450-12-HxxC Series 54mm 1U Front End AC-DC Power Supply Converter STATUS AND CONTROL SIGNALS Signal Name Description Interface Details INPUT_OK (AC Source) Output Link to connector pin The signal output is driven high when input source is available and within acceptable limits. The output is driven low to indicate loss of input power. There is a minimum of 1ms pre-warning time before the signal is driven low prior to the PWR_OK signal going low. The power supply must ensure that this interface signal provides accurate status when AC power is lost. Pulled up internally via 10K to VDD*. A logic high >2.0Vdc A logic low <0.8Vdc Driven low by internal CMOS buffer (open drain output). PW_OK (Output OK) Link to connector pin Output The signal is asserted, driven high, by the power supply to indicate that the main output is valid. Should a main output or standby output fault occur, the PW_OK signal will de-assert + driven low. 5V & 3.3V Standby output products do not de-assert the PW_OK signal during OCP event on the standby output. PW_OK output is driven low to indicate that the Main output is outside of lower limit of regulation. Pulled up internally via 10K to VDD*. A logic high >2.0Vdc A logic low <0.8Vdc Driven low by internal CMOS buffer (open drain output). Output The signal output is driven low to indicate that the power supply has detected a warning or fault and is intended to alert the system. This output must be driven high when the power is operating correctly (within specified limits). The signal will revert to a high level when the warning/fault stimulus (that caused the alert) is removed. As reported by PMBus Status_x Registers, with exception of Status_CML. Pulled up internally via 10K to VDD*. A logic high >2.0Vdc A logic low <0.8Vdc Driven low by internal CMOS buffer (open drain output). Passive connection to +VSB_Return. A logic low <0.8Vdc SMB_ALERT (FAULT/WARNING) Link to connector pin I/O PRESENT_L (Power Supply Absent) Output Link to connector pin The signal is used to detect the presence (installation) of a PSU by the host system. The signal is connected to PSU logic +VSB_Return within the power module. PS_ON (Power Supply Enable/Disable Link to connector pin Input This signal is pulled up internally to the internal housekeeping supply (within the power supply). The power supply main 12Vdc output will be enabled when this signal is pulled low to +VSB_Return. In the low state the signal input shall not source more than 1mA of current. The 12Vdc output will be disabled when the input is driven higher than 2.4V, or open circuited. Cycling this signal shall clear latched fault conditions. PS_KILL Link to connector pin Input ADDR (Address Select) Input Link to connector pin SCL (Serial Clock) Link to connector pin Both SDA (Serial Data) Link to connector pin Both V1_SENSE V1SENSE_RTN Input ISHARE Link to connector pin BiDirectional Digital Bus Pulled up internally via 10K to VDD*. A logic high >2.0Vdc A logic low <0.8Vdc Input is via CMOS Schmitt trigger buffer. Pulled up internally via 10K to VDD*. This signal is used during hot swap to disable the main output during hot swap extraction. The input is A logic high >2.0Vdc pulled up internally to VDD* (within the power supply). A logic low <0.8Vdc The signal is provided on a short (lagging pin) and should be connected to +VSB_Return. Input is via CMOS Schmitt trigger buffer. An analog input that is used to set the address of the internal slave devices (EEPROM and DC voltage between the limits of 0 and microprocessor) used for digital communications. +3.3Vdc. Connection of a suitable resistor to +VSB_Return, in conjunction with an internal resistor divider chain, will configure the required address. See configuraiton table for details. ** VIL is 0.8V maximum A serial clock line compatible with PMBusTM Power Systems Management Protocol Part 1 - General Requirements Rev 1.1. VOL is 0.4V maximum when sinking No additional internal capacitance is added that would affect the speed of the bus. 3mA The signal is provided with a series isolator device to disconnect the internal power supply bus in the VIH is 2.1V minimum event that the power module is unpowered, ** VIL is 0.8V maximum A serial data line compatible with PMBusTM Power Systems Management Protocol Part 1 - General VOL is 0.4V maximum when sinking Requirements Rev 1.1. The signal is provided with a series isolator device to disconnect the internal power supply bus in the 3mA VIH is 2.1V minimum event that the power module is unpowered, Remote sense connections intended to be connected at and sense the voltage at the point of load. The voltage sense will interact with the internal module regulation loop to compensate for voltage drops due to connection resistance between the output connector and the load. If remote sense compensation is not required then the voltage can be configured for local sense by: 1. V1_SENSE directly connected to power gold fingers P1-P8 (inclusive) 2. V1_SENSE_RTN directly connected to gold fingers P9 to P16 (inclusive) The current sharing signal is connected between sharing units (forming an ISHARE bus). It is an input and/or an output (bi-directional analog bus) as the voltage on the line controls the current share between sharing units. A power supply will respond to a change in this voltage but a power supply can also change the voltage depending on the load drawn from it. On a single unit the voltage on the pin (and the common ISHARE bus would read 8VDC at 100% load (module capability). For two identical units sharing the same 100% load this would read Compensation for a up to 0.12Vdc total connection drop (output and return connections). Analogue voltage: +8V maximum; 10K to +12V_RTN *VDD is an internal voltage rail derived from VSB and an internal housekeeping rail ("diode ORed") and is compatible with the voltage tolerances of VSB). **For robust PMBus communications, it is recommended SDA and SCA lines be pulled up via external resistors to a voltage of 3.3V or greater. www.murata-ps.com/support D1U54P-W-450-12-HXXC.A04 Page 4 of 9 D1U54P-W-450-12-HxxC Series 54mm 1U Front End AC-DC Power Supply Converter TIMING SPECIFICATIONS Turn-On Delay & Output Rise Time: 1. The turn-on delay after application of AC input within the operating range shall as defined in the following tables. 2. The output rise times shall be measured from 10% of the nominal output to the lower limit of the regulation band as defined in the following tables. Time Vsb Rise time V1 Rise time Vsb Power-on-delay V1 Power-on-delay V1 PS_ON delay V1 PWOK delay ACOK detect Min 6ms 100ms 100ms 300ms Max 10ms 60ms 2700ms 3000ms 150ms 300ms 1500ms TIMING SPECIFICATIONS Turn-Off (Shutdown by PS_ON) Turn-Off Timing V1 Fall time V1 PS_OFF delay PW_OK delay off Min 1ms Max 10ms - Notes Must be monotonic 1. Note this characteristic is applicable for the main 12Vdc output shutdown from PS_ON pulled high. www.murata-ps.com/support D1U54P-W-450-12-HXXC.A04 Page 5 of 9 D1U54P-W-450-12-HxxC Series 54mm 1U Front End AC-DC Power Supply Converter TIMING SPECIFICATIONS Power Removal Holdup Power Removal Timing Vsb holdup V1 holdup (Effective Total) Input fail detect PWOK delay off PWOK Hold Up OUTPUT CONNECTOR & SIGNAL INTERFACE Gold Finger Layout & Pin Assignment Top Side Min 40ms 12ms 5ms 1ms 11ms Max 2S 11ms - Notes 100% load 100% load 100% load 100% load 100% load Mating Connector: FCI 10126933080820xALF; "Straddle" Connector Bottom Side P13-P16 P16 P1-P4 P1 P11-P12 P5-P6 P9-P10 P7-P8 P8 P9 S20 S1 Representative View: S11 S10 Notes: Gold Fingers S9 (PS_KILL) and S12 (PS PRESENT/L) are "last to make; fist to break" short pins. For illustraiton purposes only, actual product may appear different. Dimensions as follows: W www.murata-ps.com/support D1U54P-W-450-12-HXXC.A04 Page 6 of 9 D1U54P-W-450-12-HxxC Series 54mm 1U Front End AC-DC Power Supply Converter OUTPUT CONNECTOR PIN ASSIGNMENTS - D1U54P-W-450-12-HBxC; TO BE CONFIRMED (Power Supply Gold Finger/Card Pin# Signal Name Description/Comment P1-P8 inclusive V1 (+12VOUT) +12Vdc Main Output P9-P16 inclusive V1 (+12VOUT) RTN/PGND) +12Vdc Main Output and Standby Output Return S1 +VSB S2 +VSB Standby Output S3 S4 Reserved ISHARE No User Connection Active Current Share Bus; link back to signal definition S5 SDA I2C Serial Data Line; link back to signal definition S6 S7 S8 S9 S10 S11 S12 S13 S14 S15 S16 SCL SMB_ALERT PS_ON PS_KILL INPUT_OK PW_OK S17 ADDR S18 S19 S20 Reserved I2C Serial Clock Line; link back to signal definition Alert signal to host system; link back to signal definition Remote On/Off (Enable/Disable) ; link back to signal definition Power Supply "kill"; short pin ; link back to signal definition AC Input Source Present & "OK" ; link back to signal definition Output DC Power "OK"; link back to signal definition Power Module Present; short pin; link back to signal definition No User Connection No User Connection +12Vdc Main Output Remote Sense Return +12Vdc Main Output Remote Sense Address Protocol Selection; (select address by use of the appropriate pull down resistor - see table below) ; link back to signal definition No User Connection Standby Output Standby Output PS PRESENT Reserved Reserved V1_SENSE_RTN V1_SENSE +VSB +VSB Standby Output IRIN ADDR ADDRESS SELECTION ADDR pin (A3) resistor to GND (K-ohm)* 0.82 2.7 5.6 8.2 15 27 56 180 Power Supply Main Controller (Serial Communications Slave Address) 0xB0 0xB2 0xB4 0xB6 0xB8 0xBA 0xBC 0xBE Power Supply External EEPROM (Serial Communications Slave Address) 0xA0 0xA2 0xA4 0xA6 0xA8 0xAA 0xAC 0xAE * The resistor shall be +/-5% tolerance Link back to Address Definition G DIAGRAM FOR OUTPUT www.murata-ps.com/support D1U54P-W-450-12-HXXC.A04 Page 7 of 9 D1U54P-W-450-12-HxxC Series WIRING DIAGRAM FOR OUTPUT 54mm 1U Front End AC-DC Power Supply Converter CURRENT SHARE NOTES 1. Main Output: Current sharing is achieved using the active current share method details.) 2. Current sharing can be achieved with or without the remote (V_SENSE) connected to the common load. 3. +VSB Outputs can be tied together for redundancy but total combined output power must not exceed the rated standby power. The +VSB output has an internal ORING MOSFET for additional redundancy/internal short protection. 4. The current sharing pin B5 is connected between sharing units (forming an ISHARE bus). It is an input and/or an output (bi-directional analog bus) as the voltage on the line controls the current share between sharing units. A power supply will respond to a change in this voltage but a power supply can also change the voltage depending on the load drawn from it. On a single unit the voltage on the pin (and the common ISHARE bus would read 8VDC at 100% load. For two units sharing the same load this would read 4VDC for perfect current sharing (i.e. 50% load per unit). 5. The load for both the main 12Vdc and the VSB rails at initial startup shall not be allowed to exceed the capability of a single unit. The load can be increased after a delay of 3sec (minimum), to allow all sharing units to achieve steady state regulation. www.murata-ps.com/support D1U54P-W-450-12-HXXC.A04 Page 8 of 9 D1U54P-W-450-12-HxxC Series 54mm 1U Front End AC-DC Power Supply Converter Mechanical Envelope Front to Back Airflow D1U54P-W-450-12- Hx3C Back to Front Airflow D1U54P-W-450-12- Hx4C Shown for illustration purposes only. Refer to card edge details on Pg. 6 of this datasheet for details 1. Reference file: I:\Eng_wip\UserPDDwg\1909\M1909_Drawing for Product Datasheet_20170407 2. For illustration purposes of the envelope and main features only. Not all details visible on actual product are represented. 3D model is available upon request. 3. Dimensions are in mm Link Back to Features OPTIONAL ACCESSORIES Description Part Number 12Vdc D1U54P 450W series Output Connector Card D1U54P-12-EDGE APPLICATION NOTES Document Number Description ACAN-72 D1U54P-x Communication Protocol ACAN-73 Output Connector Card with edge connector http://power.murata.com/datasheet?/data/apnotes/acan-73.pdf Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048 -1151 U.S.A. ISO 9001 and 14001 REGISTERED Link http://power.murata.com/datasheet?/data/apnotes/acan-72.pdf This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: http://www.murata-ps.com/requirements/ Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice.(c) 2016 Murata Power Solutions, Inc. www.murata-ps.com/support D1U54P-W-450-12-HXXC.A04 Page 9 of 9