1-42
The Miniature BASIC series pressure sensors are based upon a proprietary technology to reduce the size of the
sensor and yet maintain a high level of performance. The technology is currently being patented. Output
offset errors due to change in temperature, stability to warm-up, stability to long time period, and position
sensitivity are all significantly reduced when compared to conventional compensation methods. In addition the
sensor utilizes a silicon, micromachined, stress concentration enhanced structure to provide a very linear output
to measured pressure.
These offset compensated sensors give an accurate and stable output over a wide temperature range. This series
is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like.
The output of the device is ratiometric to the supply voltage and operation from any D.C. supply voltage up to
+6V is acceptable.
Offset Compensated
Pressure Sensors
• 0 to 1 “H2O to 0 to 30 “H2O Pressure Ranges
• 0.5 % linearity
• Offset Compensated
• Medical Instrumentation
• Environmental Controls
• HVAC
General Description
Applications
Features
Miniature Basic Pressure Sensors
Physical Dimensions
1-43
1
Minimum
4.0
Parameter, note 1
Operating Range, differential pressure
Output Span, @ 1 “H2O, note 5
Offset Voltage @ zero differential pressure
Offset Temperature Shift (0°C-70°C), note 2
Offset Warm-up Shift, note 3
Offset Position Sensitivity (1g)
Offset Long Term Drift (one year)
Linearity, hysteresis error, note 4
Nominal
1.0
7.0
±0.1
±10
±15
±80
0.1
Maximum
10.0
±10
±0.5
Units
“H2O
mV
mV
mV
uV
uV
uV
%fs
One Port
Part Number
1 INCH-G-BASIC
5 INCH-G-BASIC
10 INCH-G-BASIC
20 INCH-G-BASIC
30 INCH-G-BASIC
Operating Pressure
0 - 1 “H2O
0 - 5 “H2O
0 - 10 “H2O
0 - 20 “H2O
0 - 30 “H2O
Two Ports Same Side
Part Number
1 INCH-D1-BASIC
5 INCH-D1-BASIC
10 INCH-D1-BASIC
20 INCH-D1-BASIC
30 INCH-D1-BASIC
Two Ports Opposite Side
Part Number
1 INCH-D2-BASIC
5 INCH-D2-BASIC
10 INCH-D2-BASIC
20 INCH-D2-BASIC
30 INCH-D2-BASIC
Standard Pressure Ranges
Supply Supply Voltage VS
Common-mode pressure
Lead Temperature
(soldering 2-4 sec.)
6 Vdc
5 psig
250°C
Pressure Sensor Characteristics Maximum Ratings
Temperature Ranges
Compensated
Operating
Storage
Humidity Limits
0 to 70° C
-25 to 85° C
-40 to 125° C
0 to 95% RH
(non condensing)
Environmental Specifications
Performance Characteristics for 1 INCH-x-BASIC
Single in Line Packages-SIP
1-44
Minimum
15
Parameter, note 1
Operating Range, differential pressure
Output Span, @ 20 “H2O, note 5
Offset Voltage @ zero differential pressure
Offset Temperature Shift (0°C-70°C), note 2
Offset Warm-up Shift, note 3
Offset Position Sensitivity (1g)
Offset Long Term Drift (one year)
Linearity, hysteresis error, note 4
Nominal
20.0
30
±0.1
±10
±5
±80
0.1
Maximum
145
±10
±0.5
Units
“H2O
mV
mV
mV
uV
uV
uV
%fs
Minimum
15
Parameter, note 1
Operating Range, differential pressure
Output Span, @ 10 “H2O, note 5
Offset Voltage @ zero differential pressure
Offset Temperature Shift (0°C-70°C), note 2
Offset Warm-up Shift, note 3
Offset Position Sensitivity (1g)
Offset Long Term Drift (one year)
Linearity, hysteresis error, note 4
Nominal
10.0
30
±0.1
±10
±10
±80
0.1
Maximum
145
±10
±0.5
Units
“H2O
mV
mV
mV
uV
uV
uV
%fs
Minimum
15
Parameter, note 1
Operating Range, differential pressure
Output Span, @ 5 “H2O, note 5
Offset Voltage @ zero differential pressure
Offset Temperature Shift (0°C-70°C), note 2
Offset Warm-up Shift, note 3
Offset Position Sensitivity (1g)
Offset Long Term Drift (one year)
Linearity, hysteresis error, note 4
Nominal
5.0
22.5
±0.1
±10
±15
±80
0.1
Maximum
30
±10
±0.5
Units
“H2O
mV
mV
mV
uV
uV
uV
%fs
Performance Characteristics for 5 INCH-x-BASIC
Performance Characteristics for 10 INCH-x-BASIC
Performance Characteristics for 20 INCH-x-BASIC
1-45
1
Minimum
15
Parameter, note 1
Operating Range, differential pressure
Output Span, @ 20 “H2O, note 5
Offset Voltage @ zero differential pressure
Offset Temperature Shift (0°C-70°C), note 2
Offset Warm-up Shift, note 3
Offset Position Sensitivity (1g)
Offset Long Term Drift (one year)
Linearity, hysteresis error, note 4
Nominal
20.0
30
±0.1
±10
±5
±80
0.1
Maximum
145
±10
±0.5
Units
“H2O
mV
mV
mV
uV
uV
uV
%fs
Minimum
15
Parameter, note 1
Operating Range, differential pressure
Output Span, @ 10 “H2O, note 5
Offset Voltage @ zero differential pressure
Offset Temperature Shift (0°C-70°C), note 2
Offset Warm-up Shift, note 3
Offset Position Sensitivity (1g)
Offset Long Term Drift (one year)
Linearity, hysteresis error, note 4
Nominal
10.0
30
±0.1
±10
±10
±80
0.1
Maximum
145
±10
±0.5
Units
“H2O
mV
mV
mV
uV
uV
uV
%fs
Minimum
15
Parameter, note 1
Operating Range, differential pressure
Output Span, @ 5 “H2O, note 5
Offset Voltage @ zero differential pressure
Offset Temperature Shift (0°C-70°C), note 2
Offset Warm-up Shift, note 3
Offset Position Sensitivity (1g)
Offset Long Term Drift (one year)
Linearity, hysteresis error, note 4
Nominal
5.0
22.5
±0.1
±10
±15
±80
0.1
Maximum
30
±10
±0.5
Units
“H2O
mV
mV
mV
uV
uV
uV
%fs
Performance Characteristics for 5 INCH-x-BASIC
Performance Characteristics for 10 INCH-x-BASIC
Performance Characteristics for 20 INCH-x-BASIC