ISR Series
www.xppower.com 2
DC-DC Converter
Input
Output
Characteristic Minimum Typical Maximum Units Notes & Conditions
Output Voltage 5 15 VDC See Models and Ratings table
Initial Set Accuracy ±1 ±3 % At 100% load
Minimum Load 5%
Line Regulation ±0.4 %
Load Regulation ±0.75 % 10% to full load
Start Up Delay 2 ms
Ripple and Noise 60 mV pk-pk 20 MHz bandwidth, measured using 0.1 µF capacitor
Transient Response 5 % deviation Recovery to within 1% in 5 ms for a 25% load change
Short Circuit Protection Continuous, with auto recovery
Maximum Capacitive Load See Models and Ratings table
Temperature Coefficient 0.03 %/°C
Characteristic Minimum Typical Maximum Units Notes & Conditions
Input Voltage Range
918 VDC 12 V nominal
18 36 VDC 24 V nominal
36 75 VDC 48 V nominal
Input Current See Models and Ratings table
Input Reflected Ripple 15 mA pk-pk Through 12 µH inductor and 47 µF capacitor
Input Surge
25 VDC for 1 s 12 V models
50 VDC for 1 s 24 V models
100 VDC for 1 s 24 V models
Input Filter Pi filter
General
Characteristic Minimum Typical Maximum Units Notes & Conditions
Efficiency See Models and Ratings table
Isolation: Input to Output 1500 VDC
Switching Frequency 350 kHz 100% load and nominal input voltage
Isolation Resistance 109ΩInput to output, tested at 500 VDC
Isolation Capacitance 1nF Input to output
Power Density 13.4 Win3
Mean Time Between Failure 1000 kHrs MIL-HDBK-217F, +25 °C GB
Weight 0.0115 (5.2) lb (g)
Recommended Solder Profile IPC/JEDEC J-STD-020D.1
Environmental
Characteristic Minimum Typical Maximum Units Notes & Conditions
Operating Temperature -40 +95 °C Derate linearly from 100% load at +85 °C to 50% load
at 95 °C
Storage Temperature -55 +125 °C
Case Temperature +105 °C
Operating Humidity 95 % RH Non-condensing
Cooling Natural convection