Cell Type ML2430 Specifications Nominal Capacity*1 Nominal Voltage Standard Charge/Discharge Current Max. Discharge Current Charge/Discharge Cycle Characteristics Charging Method Temperature Range Weight H D d Dimensions 100mAh 3V 0.5mA Continuous *2 10mA 20mA Pulse*3 Discharging Depth of 5% 3000 Discharging Depth of 20% 500 Constant Voltage Charge 3.10.15V Hight Temperature 2.950.15V -2060 4.1g Diameter(D) 24.5mm Height(H) 3.0mm d 20mm *1 Nominal capacity is determined to an end voltage of 2.0V when the battery is allowed to discharge at a standard current level at 23oC. *2 Current value is determined so that 50% of the nominal capacity is obtained with an end voltage of 2.0V at 23 oC. *3 Current value for obtaining 2.0V cell voltage when 15sec. pulse is applied at 50% discharge depth at 23 oC. Typical Characteristics Charge Characteristics of ML2430 Charging Voltage vs. Capacity of ML2430 3.0 100 Cell Voltage(V) Charge Capacity 2.5 Charge Circuit Temp.:23 oc 75ohm 2.0 50 3.1V ML2430 1.5 discharged cell to 2.0V 1.0 Discharge Capacity(mAh) Cell Volatge Charge Capacity(mAh) 3.5 20 40 Duration(hour) 2.6 2.8 3.0 3.2 Charging Voltage(V) Charge/ Discharge Cycle Characteristics of ML2430 10000 3.5 Number of Cycles 3.0 2.5 o 60 C 2.0 o o -20 C Charge:3.1V+75ohm Discharge:3mA o Temp.:23 C 5000 Charging Voltage : 3.1V Load : 5.6kohm Cell Voltage(V) 50 60 Temperature Characteristics of ML2430 23 C 1.5 1000 500 100 50 10 1.0 0 50 100 150 200 Duration(hour) 250 300 Discharge Characteristics after Continuous Charge of ML2430 3.5 Discharge Condition Load : 27kohm Temp. : 23 oc 3.0 Cell Voltage(V) 100 0 0 0 Charge Condition(discharged cell to 2.0V) Load:200ohm Temp.:23 oc Charge Duration: 1month Discharge Condition Load:5.6kohm Temp.:23 oc End Voltage:2.0V 2.5 2.0 Initial(3.25V charged) after 200days continuous charged 3.25V at 60oc 1.5 1.0 0 10 20 30 40 Duration(day) 50 60 70 80 0 50 Discharge Depth(%) 100