285
DC
(Pa)(inch H2O)
(CFM)
(m3/min)
静圧
風量
0
0.05
0.10
0.15
0.20
0.25
0 5010 20 30 40
20
0
10
50
30
40
60
0.5 1.0 1.5
13.8 V
12 V
10.2 V
(Pa)(inch H2O)
(CFM)
(m3/min)
静圧
風量
0
0.05
0.10
0.15
0.20
0 10 20 30 40
20
0
10
50
30
40
0.5 1.0
13.8 V
12 V
10.2 V
(Pa)(inch H2O)
(CFM)
(m3/min)
静圧
風量
0
0.05
0.10
0.15
0.20
0 10 20 30 40
20
0
10
50
30
40
0.5 1.0
13.8 V
12 V
10.2 V
Splash Proof Fan 80 mm sq.
Model no.
Rated voltage
Operating voltage range
Rated current
Rated input Rated speed Max. airow
Max. static pressure
SPL
Operating temperature
Expected life
[V] [V] [A] [W] [min-1]
[m³/min]
[CFM] [Pa] [inchH²O] [dB (A)] [˚C] [h]
9WS0812H401
12 10.2 to 13.8
0.16 1.92 3100 0.94 33.2 45.1 0.181 32
-20 to +70
40000/60˚C
9WS0812F401 0.13 1.56 2700 0.83 29.3 34.3 0.138 28
9WS0812M401 0.1 1.2 2200 0.65 23.0 23.5 0.094 23
9WS0824H401
24 20.4 to 27.6
0.09 2.16 3100 0.94 33.2 45.1 0.181 32
9WS0824F401 0.07 1.68 2700 0.83 29.3 34.3 0.138 28
9WS0824M401 0.05 1.2 2200 0.65 23.0 23.5 0.094 23
The following sensor and control options are available for selection.
Available for all models. Without sensor
Differs according to the model. Refer to the table on p. 581. Lock sensor
Static pressure
Airow
Static pressure
Airow
Static pressure
Airow
Splash Proof Fan
80×80×25 mm
San Ace 80WS 9WS type
■General Specications
・ Material ………………………………………… Frame: Plastic (Flammability: UL 94V-0), Impeller: Plastic (Flammability: UL 94V-1)
・ Expected life …………………………………… See the table below. (L10 life: 90% survival rate for continuous operation in indoor free air
at 60˚C, rated voltage)
・ Motor protection function ………………… Locked rotor burnout protection, Reverse polarity protection
For details, please refer to p. 547.
・ Dielectric strength …………………………… 50/60 Hz, 500 VAC, for 1 minute (between lead wire conductors and frame)
・ Insulation resistance ………………………… 10 MΩ or more with a 500 VDC megger (between lead wire conductors and frame)
・ Sound pressure level (SPL) ……………… At 1 m away from the air inlet
・ Storage temperature ……………………… -30 to +70˚C (Non-condensing)
・ Lead wire ……………………………………… Red Black or Blue Sensor Yellow
・ Mass ……………………………………………… 120 g
・ Ingress protection …………………………… IP54
■Specications
The models listed below have ribs and pulse sensors. For models without ribs, append "1" to the end of model numbers.
Operating voltage range Operating voltage range Operating voltage range
■Airow - Static Pressure Characteristics
9WS0812H401 With pulse sensor 9WS0812F401 With pulse sensor 9WS0812M401 With pulse sensor