XPress DR+W Industrial Device Server 2006 Copyright (c) Lantronix is a trademark of Lantronix. All rights reserved. 900-446 Rev. A 10/06 XPress DR+W Quick Start Guide XPRESS DR+W QUICK START CONTENTS What's In the Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-5 XPress DR+W Industrial Device Server Quick Connect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-7 Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Connect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-9 Configure IP Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-10 Configure WLAN Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-12 Test Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 Quick Start Guide XPress DR+W WHAT'S IN THE BOX PINOUTS Verify and inspect the contents of the package using the enclosed packing slip or the list below. If any item is missing or damaged, contact your place of purchase immediately. * XPress DR+W * CD (with protocols, utilities, and User Guide) * Quick Start Guide * P/N: 930-029 antenna * P/N: 500-103 RJ45-DB9F serial cable * Accessory Din-rail wall mount bracket * 3-terminal screw connector for power input * 5-terminal screw connector for serial port The user must supply a 9-30 VDC or 9-24 VAC power source and a CAT 5 Ethernet cable. The XPress DR+W supports RS-232 via RJ45 connectors. It also supports RS-422/485 via screw terminals (Serial Port 2 only). Note: Serial Port 2 supports RS232, RS422, and RS485, but only one mode at a time. This means you can use either the RJ45 connector or the terminal block, not both. The RJ45 serial connectors only support RS232, up to 230,400 bits per second. The supplied Lantronix P/N: 500-103 serial cable can be used to connect port 1 of XPress DR+W to a PC's com port for configuration using a terminal emulation application. Refer to the XPress DR+W User Guide for information on configuring the XPress DR+W though the serial interface. RJ45 Serial Connector Pinouts OVERVIEW The XPress DR+W industrial device server provides a quick, easy and flexible method to network-enable multiple industrial devices and equipment over an 802.11 wireless or a 10/100 Ethernet LAN. The SwitchPort+ embedded switch technology and multiple serial ports enable real-time access for remote programming, monitoring and control of PLCs, motor drives, HVAC, building automation equipment, or virtually any RS232, RS422 or RS485 device. 2 W W W. L A N T R O N I X . CO M 3 Quick Start Guide XPress DR+W PINOUTS CONTINUED... Screw Terminal Serial Connectors Serial Screw Terminal Pinout for RS422 (4-Wire) PINOUTS CONTINUED Note: Termination resistors (R = 120 Ohm) are used to match impedance of a node to the impedance of the transmission (TX) line.Termination resistors should be placed only at the extreme ends of the TX data lines, and no more than two terminations should be placed in any single segment of an RS-485 network.Termination resistors may not be needed for your application. 9-Pin RS-232 to Serial RJ45 Serial Screw Terminal Pinout for RS485 (2-Wire) The included Lantronix P/N (500-103) RJ45-DB9F serial cable assumes you are connecting a typical PC Com port to the XPress DR+W serial port. This cable is pinned to provide full serial line control to an RS232 DTE device. Lantronix offers a comprehensive list of cables and adapters to simplify device connectivity to the XPress DR+W. See the User Guide for a full listing. Lantronix P/N (500-103) RS45-DB9F Serial Cable Pinout Serial Screw Terminal Pinout for RS485 (2-Wire) 4 W W W. L A N T R O N I X . CO M 5 Quick Start Guide XPress DR+W QUICK CONNECT QUICK CONNECT CONTINUED Typical Installation Ethernet Access Point RS-232 XPress-DR+W 9-30 VDC 9-24 VAC 1. Connect a serial device to your XPress DR+W. 2. Screw the antenna that comes with the unit into the antenna connector. 3. Supply power to your XPress DR+W using a 9-30 VDC or 9-24 VAC (2.3 W maximum) source. 4. Supply power to the serial device. 5. Verify that the yellow wireless LED is lit. 6 W W W. L A N T R O N I X . CO M 7 Quick Start Guide XPress DR+W GETTING STARTED CONNECT CONTINUED REQUIRED SETTINGS 4. Enter Setup Mode by simultaneously connecting the power supply and holding down the x key on the keyboard. Upon connection, the following information displays: For the XPress DR+W to operate on a wireless network, two critical settings are required: 1. IP address settings 2. Appropriate wireless settings By default, the unit is set to Ad-Hoc network mode and its wireless Network Name (SSID) is "LTRX_IBSS". Many networks use an automatic method of assigning an IP address called DHCP. The XPress DR+W supports DHCP. However, before it can accept an IP address from DHCP, the wireless settings must be set. 5. Press Enter within 5 seconds to display the Change Setup menu. CONNECT CONFIGURE IP ADDRESS Initial configuration is done using Serial Mode. In most installations, a fixed IP address and wireless LAN settings are desired. The systems administrator generally provides these. Two configuration options must be set for the XPress DR+W to communicate on a wireless network: 1. The Server (0) settings 2. The WLAN (4) settings Current settings display in parentheses. 1. To configure the Server settings, select 0 from the Change Setup menu and edit the following fields: a) IP Address: The IP address must be set to a unique value in the network. Type each octet and press Enter between each section typed. Complete the following steps to connect and configure the XPress DR+W. 1. Connect the RJ45 side of the supplied RJ45 - DB9F null modem cable to serial port 1 on the XPress DR+W. 2. Connect the DB9 end of the serial cable to a terminal or a PC's serial COM port. 3. On the PC, open a terminal emulation application (e.g. HyperTerminal). The default serial settings are: 9600 baud, 8 bits, no parity, 1 stop bit, and no flow control (9600, 8, N, 1). 8 IP Address: (000) .(000) .(000) .(000) _ W W W. L A N T R O N I X . CO M 9 Quick Start Guide XPress DR+W CONFIGURE IP ADDRESS CONTINUED b) Set Gateway IP Address: The gateway address should be the IP address of the router connected to the same LAN segment as the XPress DR+W. Set Gateway IP Address (N)? N c) Netmask: The netmask defines the number of bits taken from the IP address that are assigned for the host part. Enter the number of host bits. If you leave this blank and press Enter, the XPress DR+W will set the subnet mask to a standard netmask for the IP address assigned in step a) above. Netmask: Number of Bits for Host Part (0=default)(0)_ d) Change Telnet Configuration Password: Change the Telnet configuration password to prevent unauthorized access to the Setup Menu. Change telnet config password (N) ? _ CONFIGURE WLAN SETTINGS 1. To configure the WLAN settings, select 4 from the Change Setup menu and answer the setup questions. The following example shows basic wireless setup without encryption. Note: For WEP or WPA encryption setup, please refer to the Users Guide on the CD. a) Select Ad-Hoc (IBSS mode) as the system topography (default is Ad-Hoc). Topology 0=Infrastructure, 1=Ad-Hoc (1) ? _ b) Enter the Network name (SSID) (default is LTRX_IBSS). Network name (LTRX_IBSS) ? _ c) Set the Ad-Hoc channel (only displays in Ad-Hoc topology). Channel (11) ? _ e) Change DHCP Device Name: Change the DHCP name if desired. Change DHCP device name (not set) ? (N) N d) Select the type of security (default is none). Security suite: 0=none, 1=WEP (0) ? e) Select either fixed or automatic data rate (default is auto fallback). TX Data rate 0=fixed, 1=auto fallback (1) ? _ 10 W W W. L A N T R O N I X . CO M 11 Quick Start Guide XPress DR+W CONFIGURE WLAN SETTINGS CONTINUED f ) For a fixed data rate, select the transmission data rate (default is 11 Mbps). TX Data rate 0=1, 1=2, 2=5.5, 3=11 4=18, 5=24, 6=36, 7=54 Mbps (3) ? _ 2. Upon completing the IP and WLAN settings, select menu option 9 to save and exit the Serial Mode setup. TEST CONNECTION LEDS MEANING Serial port - TXD LED (Yellow) Off Blinking No data being transmitted from XPress DR+ Data being transmitted from XPress DR+ Serial port - RXD LED (Green) Off Blinking No data being received by XPress DR+ Data being received by XPress DR+ Ethernet port - 10/100 Link (Green) Off Steady On No Ethernet link established Ethernet link established Ethernet port - Activity (Yellow) ) Off Blinking No data activity Data activity Power/Diagnostic LED (Orange) Steady On Blinking 2x Blinking 2x Power OK No DHCP response Setup Menu active Wireless LED (Yellow) Off Off Blinking (very short) On On when receiving or transmitting, off in-between Wireless off (not configured for wireless) Wireless on, searching Wireless on, attempting to associate Wireless on, associated, power management off Wireless on, associated, power management on The XPress DR+W is ready for wireless connection. To verify that the unit established a WLAN connection, open a browser from a PC on the same wireless network and enter the IP address of the unit in the URL field, http://xxx.xxx.xxx.xxx. The XPress DR+W web interface should display. Once you have completed the configuration, disconnect the serial cable from the PC to the unit. This cable may also be used to connect various serial devices to the XPress DR+W. STATUS CONTACT For questions and technical support, please check our online knowledge base at www.lantronix.com/support Lantronix 15353 Barranca Parkway, Irvine, CA 92618, USA Phone: (949) 453-3990 or Fax: (949) 453-3995 www.lantronix.com 12 W W W. L A N T R O N I X . CO M 13 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Lantronix: 500-104 500-101 500-135 500-137 500-103 500-102