ACA-20RM-ALM Series
True-rms-AC Ammeters with Alarm Function
MPM_ACA-20RM-ALM.B01 Page 2 of 5
TECHNICAL NOTES
IMPORTANT! To ensure safe and reliable operation, ACA-20RM-
ALM ammeters must be installed and serviced by qualifi ed
technical personnel. Contact Murata Power Solutions if there is
any doubt regarding ammeter setup, installation, or operation.
1. Measurement Type: ACA-20RM-ALM ac ammeters employ a
true-rms input circuit to measure current fl owing through L1. Stated
accuracy specifi cations are measured using a sine-wave current
at, or close to, the ammeter’s full-scale input range, at nominal line
frequency of 60Hz.
2. Calibration (Potentiometer R7): Periodic recalibration of ACA-
20RM-ALM ammeters is not required under normal, indoor operating
environments. If user calibration is necessary, it must be performed
by qualifi ed technical personnel. Calibration is performed with poten-
tially lethal voltages applied to the ACA-20RM-ALM and its associated
wiring. A plastic, fully-insulated adjusting tool must be used to access
the calibration potentiometer R7 located on the back of the ammeter
(see ‘Mechanical Specifi cations’ section). Contact MPS if additional
information is required regarding calibration, setup, or any other
technical issue pertaining to ACA-20RM-ALM ammeters.
3. Overcurrent Alarm Setup and Adjustment (Potentiometer R3):
ACA-20RM-ALM ammeters feature a user-settable, overcurrent visual
alarm indication which can be used to alert operators that a load cir-
cuit breaker or fuse is approaching an overload condition. When the
load current sensed by L1 exceeds this preset level, the ammeter’s
LED display will fl ash from normal intensity to dim intensity at rate of
approximately 1.5 times per second.
As shown in Figure 3, the alarm circuit consists of jumper JP1, and
adjustment potentiometer R3. As shipped, R3 is factory set to trip
when the load current is approximately 24 Amps for 30A models, and
approximately 45 Amps for 50A models. When R3 is set to its maxi-
mum clockwise position, the alarm indication will not activate until the
load current fl owing through L1 exceeds the maximum rating of the
ammeter, i.e., above 30.0A, or above 50.0A, depending on the model.
Performance/Functional Specifi cations
Typical at TA = +25°C, unless otherwise noted.
➀ Specifi ed full-scale currents are those passing through the ammeter’s built-in
current transformer’s primary load-circuit. See Notes 2 and 3 below for ad-
ditional model-specifi c information.
➁ The overcurrent rating of 1.5 x the rated full-scale current is a continuous rating
and applies to the current passing through the built in current transformer only,
it does not apply to any external circuit-wiring or external loads. Accuracy is
guaranteed up to the rated current level.
➂ Specifi ed accuracy applies to inputs with crest factors (CF) up to 2.0, where CF
= Vpeak/Vrms. Crest factors of 2 to 5 introduce an additional error of ±3% of full
scale. Ammeters are calibrated with a near full-scale 60Hz sine-wave current
fl owing through the ammeter’s built-in CT.
➃ All specifi ed maximum power supply currents are steady state; larger surge
currents can occur at initial application of line power.
Rated Full-Scale Current ➀Min. Typ. Max. Units
ACA-20RM-4-ACX-RL-ALM — — 50.0 Amperes
ACA-20RM-5-ACX-RL-ALM — — 30.0 Amperes
Overcurrent Rating ➁1.5 x Rated Full-Scale Current
Performance
Sampling Rate 2.5 Samples per second
Accuracy ➂±0.4%FS ±3 Counts with 60Hz
Sine-Wave Input
Measurement Type rms Responding, Crest Factors of 1-5
Temperature Drift (0 to 60 °C) — ±0.2 ±0.4 Counts/ºC
Zero-Current Reading (within
30 sec.)
–001 000 001 Counts
Dielectric Withstanding Voltage 2000 — — Vdc
UL/IEC61010-1 Measurement category II
Power Supply Voltage
ACA-20RM-X-AC3-RL-ALM 85 120 140 Vac/47-63Hz
ACA-20RM-X-AC4-RL-ALM 170 220 264 Vac/47-63Hz
Power Supply Current ➃
ACA-20RM-X-AC3-RL-ALM — 30 50 mA/47-63Hz
ACA-20RM-X-AC4-RL-ALM — 30 50 mA/47-63Hz
Alarm Function
Display indication Flashing Display with actual current
reading and display intensity change
Settable range
ACA-20RM-4-ACX-RL-ALM 13 45 50 Amps
ACA-20RM-5-ACX-RL-ALM 8 24 30 Amps
Power Supply Terminal Block
Wire Size 16-22AWG, Solid or stranded
Insulation Strip Length 0.250 inches
Screw Tightening Torque 3.6 pounds-inches (0.4Nm)
Rated Voltage 310Vac
Display
Display Type and Size 3½ Digit Red LED, 0.37”/9.4mm High
Overrange Indication “1___”
Decimal Point Fixed, model dependent
(see full-scale input current)
Physical/Environmental
Operating Temperature 0 — +60 °C
Storage Temperature –40 — +75 °C
Humidity (non-condensing) 0 — 85 %
Dimensions Model dependent, see page 4 & 5
Weight
ACA-20RM-4-XXX-XX-ALM 1.5 Ounces (43 grams) nominal
ACA-20RM-5-XXX-XX-ALM 2.1 Ounces (60 grams) nominal
Ordering Information
ACA-20RM-4-AC3-RL-ALM-C 50.0A Range (split-core CT), 85-140Vac power
ACA-20RM-4-AC4-RL-ALM-C 50.0A Range (split core CT), 170-264Vac power
ACA-20RM-5-AC3-RL-ALM-C 30.0A Range, 85-140Vac power
ACA-20RM-5-AC4-RL-ALM-C 30.0A Range, 170-264Vac power
See www.murata-ps.com/dpm-availability for model-specifi c availability.