For more information, please visit the product page. date 06/21/2018 page 1 of 10 SERIES: PDQE10 DESCRIPTION: DC-DC CONVERTER FEATURES * * * * * * * * * * industry standard footprint board, chassis and Din rail versions available industrial operating temp -40~+85C 1500 Vdc isolation voltage industry standard footprint compatible with CUI legacy PDQ10 series high efficiency up to 88% 4:1 input rating single & dual output models available output short circuit, over current & overvoltage protection compliant with CISPR22/EN55022 Class A MODEL input voltage output voltage output current output power ripple & noise1 efficiency2 typ (Vdc) range (Vdc) (Vdc) min (mA) max (mA) max (W) max (mVp-p) typ (%) PDQE10-Q24-S3 24 9~36 3.3 0 2400 7.92 80 79 PDQE10-Q24-S5 24 9~36 5 0 2000 10 80 83 PDQE10-Q24-S9 24 9~36 9 0 1111 10 80 86 PDQE10-Q24-S12 24 9~36 12 0 833 10 80 87 PDQE10-Q24-S15 24 9~36 15 0 667 10 80 87 PDQE10-Q24-S24 24 9~36 24 0 416 10 80 88 PDQE10-Q24-D53 24 9~36 5 0 1000 10 80 83 PDQE10-Q24-D9 24 9~36 9 0 555 10 80 86 PDQE10-Q24-D123 24 9~36 12 0 416 10 80 87 3 PDQE10-Q24-D15 24 9~36 15 0 333 10 80 87 PDQE10-Q24-D243 24 9~36 24 0 208 10 80 87 PDQE10-Q48-S3 48 18~75 3.3 0 2400 7.92 80 79 PDQE10-Q48-S5 48 18~75 5 0 2000 10 80 83 PDQE10-Q48-S12 48 18~75 12 0 833 10 80 87 PDQE10-Q48-S15 48 18~75 15 0 667 10 80 87 PDQE10-Q48-S24 48 18~75 24 0 416 10 80 88 PDQE10-Q48-D5 48 18~75 5 0 1000 10 80 83 PDQE10-Q48-D12 48 18~75 12 0 416 10 80 87 PDQE10-Q48-D15 48 18~75 15 0 333 10 80 87 PDQE10-Q48-D24 48 18~75 24 0 208 10 80 87 3 Notes: 1. From 5~100% load, nominal input, 20 MHz bandwidth oscilloscope, with 10 F tantalum and 1 F ceramic capacitors on the output. From 0~5% load, ripple and noise is <5% Vo. 2. Measured at nominal input voltage, full load. The typical efficiencies for the chassis mount and DIN-rail mount versions are ~2% less than the DIP versions due to the input reverse polarity protection. 3. In addition to all DIP versions, chassis mount and DIN-rail mount versions of these models are UL approved. 4. All specifications are measured at Ta=25C, humidity < 75%, nominal input voltage, and rated output load unless otherwise specified. cui.com For more information, please visit the product page. CUI Inc SERIES: PDQE10 DESCRIPTION: DC-DC CONVERTER date 06/21/2018 page 2 of 10 PART NUMBER KEY PDQE10 - QXX - X XX - X Base Number Input Voltage Output: S = single D = dual Output Voltage Mounting Style: D = DIP T = chassis mount DIN = DIN-rail mount INPUT parameter conditions/description min typ max units operating input voltage5 24 Vdc input models 48 Vdc input models 9 18 24 48 36 75 Vdc Vdc start-up voltage5 24 Vdc input models 48 Vdc input models 9 18 Vdc Vdc surge voltage for maximum of 1 second 24 Vdc input models 48 Vdc input models -0.7 -0.7 50 100 Vdc Vdc under voltage shutdown 24 Vdc input models 48 Vdc input models 5.5 12 Vdc Vdc 24 Vdc input models 3.3 Vdc output models all other models 429 515 mA mA 48 Vdc input models 3.3 Vdc output models all other models 215 258 mA mA 10 mA current remote on/off (CTRL)6 turn on (3.5~12 Vdc or open circuit) turn off (<1.2 Vdc) input current when switched off filter Pi filter input reverse polarity protection only present on chassis mount and DIN-rail mount models 6 no load power consumption Notes: 6.5 15.5 0.12 W 5. The minimum input voltage and start-up voltage for the chassis mount and DIN-rail mount versions are 1 Vdc higher than the DIP versions. 6. The voltage of the Ctrl pin is referenced to input GND pin. OUTPUT parameter conditions/description maximum capacitive load7 3.3, 5 Vdc output models 5 Vdc output models 9, 9 Vdc output models 12 Vdc output models 15 Vdc output models all other models voltage accuracy8 0% to full load line regulation from low line to high line, full load positive outputs negative outputs load regulation9 from 5% to full load positive outputs negative outputs voltage balance10 dual output models Note: min 7. Tested at input voltage range and full load. 8. At 0~5% load, the max output voltage accuracy for the 5 & 9 Vdc output models is 5%. 9. At 0~100% load, the max load regulation is 5%. 10. Unbalanced loads should not exceed 5%. If 5% is exceeded, the product performance cannot be guaranteed. cui.com typ max units 2,200 1,000 680 470 330 100 F F F F F F 1 3 % 0.2 0.5 0.5 1 % % 0.5 0.5 1 1.5 % % 5 % For more information, please visit the product page. CUI Inc SERIES: PDQE10 DESCRIPTION: DC-DC CONVERTER date 06/21/2018 page 3 of 10 OUTPUT (CONTINUED) parameter conditions/description cross regulation dual output models: main output 50% load secondary output from 10~100% load switching frequency11 PWM mode 350 transient recovery time 25% load step change, nominal input voltage 300 transient response deviation 25% load step change, nominal input voltage 3 temperature coefficient at full load Note: min typ max units 5 % kHz 500 s 5 % 0.03 %/C max units 11. Value is based on full load. At loads <10%, the switching frequency decreases with decreasing load PROTECTIONS parameter conditions/description min typ over voltage protection 110 160 % over current protection 110 140 190 % min typ max units short circuit protection continuous, self recovery SAFETY AND COMPLIANCE parameter conditions/description isolation voltage input to output for 1 minute at 1 mA 1,500 Vdc isolation resistance input to output at 500 Vdc 1,000 M isolation capacitance input to output, 100 kHz / 0.1 V safety approvals12 UL 60950-1 conducted emissions CISPR22/EN55022, class A (no external circuit); class B (external circuit required, see Figure 3-b) radiated emissions CISPR22/EN55022, class A (no external circuit); class B (external circuit required, see Figure 3-b) ESD IEC/EN61000-4-2, contact 4kV, class B radiated immunity IEC/EN61000-4-3, 10V/m, class A EFT/burst IEC/EN61000-4-4, 2kV, class B (external circuit required, see Figure 3-a) surge IEC/EN61000-4-5, line-line 2kV, class B (external circuit required, see Figure 3-a) conducted immunity IEC/EN61000-4-6, 3 Vr.m.s, class A voltage dips & interruptions IEC/EN61000-4-29, 0%-70%, class B MTBF as per MIL-HDBK-217F, 25C RoHS Note: 1,000 1,000,000 yes 12. See specific chassis mount and DIN-rail mount versions with UL approval on page 1. cui.com pF hours For more information, please visit the product page. CUI Inc SERIES: PDQE10 DESCRIPTION: DC-DC CONVERTER date 06/21/2018 page 4 of 10 ENVIRONMENTAL parameter conditions/description min max units operating temperature see derating curves -40 85 C -55 125 C 5 95 % storage temperature storage humidity non-condensing vibration 10~55 Hz for 30 minutes on each axis typ 10 G DERATING CURVES Temperature Derating Curve (Natural Convection) 120 All other outputs 3.3, 5, 5 Vdc outputs Output Load (%) 100 80 60 40 20 0 -40 0 65 71 40 85 120 Ambient Temperature (C) SOLDERABILITY13 parameter conditions/description hand soldering wave soldering max units 1.5 mm from case for 10 seconds 300 C see wave soldering profile 260 C 13. For DIP models only. Peak Temp. 260C Max. Wave Soldering Time 4 Sec. Max. 250 200 Temperature (C) Note: min 10 Sec. Max. 150 100 50 0 Time (sec.) cui.com typ For more information, please visit the product page. CUI Inc SERIES: PDQE10 DESCRIPTION: DC-DC CONVERTER date 06/21/2018 page 5 of 10 MECHANICAL parameter conditions/description DIP Chassis DIN-Rail dimensions min typ max 25.40 x 25.40 x 11.70 [1.000 x 1.000 x 0.461 inch] 76.00 x 31.50 x 21.20 [2.992 x 1.240 x 0.834 inch] 76.00 x 31.50 x 25.80 [2.992 x 1.240 x 1.016 inch] case material aluminum alloy weight DIP Chassis mount DIN-rail mount mm mm mm 15 35 55 MECHANICAL DRAWING (DIP) units: mm [inch] tolerance: 0.50[0.020] pin diameter tolerance: 0.10[0.004] PIN CONNECTIONS PIN Function Single Dual 1 GND GND 2 Vin Vin 3 +Vout +Vout 4 No Pin 0V 5 0V -Vout 6 CTRL CTRL Recommended PCB Layout Top View MECHANICAL DRAWING (CHASSIS) units: mm [inch] tolerance: 0.50[0.020] wire range: 24~12 AWG tightening torque: max 0.4 N*m PIN CONNECTIONS PIN Function Single Dual 1 CTRL CTRL 2 GND GND 3 Vin Vin 4 0V -Vout 5 NC 0V 6 +Vout +Vout cui.com units g g g For more information, please visit the product page. CUI Inc SERIES: PDQE10 DESCRIPTION: DC-DC CONVERTER date 06/21/2018 page 6 of 10 MECHANICAL DRAWING (DIN-RAIL) units: mm [inch] tolerance: 0.50[0.020] installed on DIN rail TS35 wire range: 24~12 AWG tightening torque: max 0.4 N*m PIN CONNECTIONS PIN Function Single Dual 1 CTRL CTRL 2 GND GND 3 Vin Vin 4 0V -Vout 5 NC 0V 6 +Vout +Vout cui.com For more information, please visit the product page. CUI Inc SERIES: PDQE10 DESCRIPTION: DC-DC CONVERTER date 06/21/2018 page 7 of 10 APPLICATION CIRCUIT This series has been tested according to the following recommended circuits (Figures 1 & 2) before leaving the factory. If you want to further reduce the input and output ripple, you can increase the input and output capacitors or select capacitors of low equivalent impedance provided that the capacitance is less than the maximum capacitive load of the model. Figure 1 Single Output Models Table 1 Vin (Vdc) Cin (F) Cout (F) 24 100 10 48 10~47 10 Figure 2 Dual Output Models EMC RECOMMENDED CIRCUIT Figure 3 Table 2 Recommended External Circuit Components Vin (Vdc) FUSE 24 48 choose according to actual input current MOV S20K30 S14K60 C0 330 F / 50 V 330 F / 100 V C1 1 F / 50 V 1 F / 100 V C2 10 F LDM1 4.7 H CY1, CY2 1 nF / 2 kV cui.com For more information, please visit the product page. CUI Inc SERIES: PDQE10 DESCRIPTION: DC-DC CONVERTER date 06/21/2018 page 8 of 10 PACKAGING (DIP) units: mm Tube Size: 28.6 x 19.8 mm Inner Carton Size: 575 x 135 x 100 mm Outer Carton Size: 600 x 285 x 225 mm Outer Carton QTY: 912 pcs cui.com For more information, please visit the product page. CUI Inc SERIES: PDQE10 DESCRIPTION: DC-DC CONVERTER date 06/21/2018 page 9 of 10 PACKAGING (CHASSIS, DIN-RAIL MOUNT) units: mm Inner Carton Size: 370 x 350 x 115 mm Outer Carton Size: 400 x 365 x 255 mm Outer Carton QTY: 912 pcs cui.com For more information, please visit the product page. CUI Inc SERIES: PDQE10 DESCRIPTION: DC-DC CONVERTER date 06/21/2018 page 10 of 10 REVISION HISTORY rev. 1.0 description date initial release 06/21/2018 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.