Industrial Cord NOW RED A STO ITEM CK Carolprene 90C Welding Cable (R) 600 Volt Cord & Cordset Product Construction: Conductor: * 6 AWG through 500 kcmil fully annealed stranded bare copper Class K Jacket: * Premium-grade 90C EPDM, black or red * Temperature range: -40C to +90C Jacket Marking: * CAROLPRENE (SIZE) WELDING CABLE 600 VOLT MADE IN USA (TRU-MARK SEQUENTIAL FOOTAGE) CAROLPRENE(R) WELDING CABLE - 600 VOLT - CLASS K - 30 AWG STRANDING Applications: * Secondary voltage resistance welding leads * Power supply applications not exceeding 600 volts AC Features: * Good flexibility * Abrasion-resistant * Good color retention * TRU-Mark(R) sequential footage marking Packaging: * 250' (76.2 m), 500' (152.4 m), and 1000' (304.8 m) reels * MCM sizes cut to length * Other put-ups available on special order Industry Approvals: * RoHS Compliant Suggested Ampacities For 600 Volt In-Line Applications AWG OR kcmil AMPERES AWG AMPERES 500 kcmil 695 1/0 190 350 kcmil 552 1 160 250 kcmil 445 2 140 4/0 310 4 100 3/0 265 6 75 2/0 223 Ampacities for portable cable, continuous-duty (ambient temperature of 40C). May not be suitable for all installations per National Electrical Code(R). Ordering Part Number Example 01771.38.03 4/0 500' put-up in red .03 for red jacket CATALOG NUMBER AWG OR kcmil 01778 01777 APPROX. NET WT. LBS/M'(S) STD. CTN. 9.65 135 250' 10.16 172 250' 11.81 260 250' 12.57 317 250' 0.560 14.22 400 250' 0.615 15.62 487 250' 1613/30 0.670 17.02 605 250' 2029/30 0.750 19.05 827 250' 2496/30 0.830 21.08 976 250' 3441/30 0.960 24.38 1338 250' 5054/30 1.200 30.48 1995 250' NOMINAL O.D. CONDUCTOR STRAND INCHES 6 259/30 0.380 4 406/30 0.400 01776 2 646/30 0.465 01775 1 812/30 0.495 01774 1/0 1025/30 01773 2/0 1274/30 01772 3/0 01771 4/0 99142* 250 kcmil 99432* 350 kcmil 99202* 500 kcmil mm (S) Actual shipping weight may vary. * Non-stock item; minimum quantity required. WELDING CABLE AMPACITIES SINGLE CONDUCTOR Required Cable Sizes: For Welding Cable Application AMPS 100 150 200 250 300 350 400 450 500 550 600 length in feet for total circuit for secondary voltages only - do not use this table for 600 Volt in-line applications 100' 150' 200' 250' 300' 350' 400' 4 4 2 2 1 1/0 1/0 4 2 1 1/0 2/0 3/0 3/0 2 1 1/0 2/0 3/0 4/0 4/0 1 1/0 2/0 3/0 4/0 1/0 2/0 3/0 4/0 1/0 3/0 4/0 2/0 3/0 2/0 4/0 3/0 4/0 3/0 4/0 4/0 REQUIRED CABLE SIZES SHOWN IN AWG NUMBERS The total circuit length includes both welding and ground leads (based on 4-volt drop) 60% duty cycle. These values for current-carrying capacity are based on a copper temperature of 60C (140F), an ambient temperature of 40C (104F) and yield load factors from approximately 32% for the No. 2 AWG cable to approximately 23% for the No. 3/0 AWG cable, and higher for the smaller sizes. The sizes of cables generally used range from No. 2 AWG to No. 3/0 AWG. In actual service, the load factor may be much higher than indicated without overheating the cable, as the ambient temperature will generally be substantially lower than 40C. 37 Industrial Cord Cord & Cordset Super Vu-Tron Welding Cable (R) 90C, 600 Volt, UL /CSA, RHH/RHW Product Construction: Conductor: * 6 AWG through 4/0 AWG fully annealed stranded bare copper per ASTM B172 Class M Jacket: * Super Vu-Tron(R), orange * Temperature range: -50C to +90C Jacket Marking: SUPER VU-TRON WELDING CABLE--UL/CSA--CLASS M--34 AWG STRANDING (R) mm APPROX. NET WT. LBS/M'(S) STD. CTN. 0.370 9.40 125 250' 0.415 10.54 191 250' 1634/34 0.475 12.07 259 250' 2090/34 0.530 13.46 331 250' 1/0 2597/34 0.575 14.61 401 250' 01763 2/0 3300/34 0.630 16.00 511 250' 01762 3/0 4214/34 0.700 17.78 615 250' 01761 4/0 5225/34 0.800 20.32 844 250' CATALOG NUMBER AWG SIZE CONDUCTOR STRAND 01768* 6 660/34 01767* 4 1045/34 01766 2 01765 1 01764 NOMINAL O.D. INCHES * Not MSHA Approved. (S) Actual shipping weight may vary. Type RHH/RHW - 600 V for CT use. WELDING CABLE AMPACITIES SINGLE CONDUCTOR Required Cable Sizes: For Welding Cable Application AMPS 100 150 200 250 300 350 400 450 500 550 600 length in feet for total circuit for secondary voltages only - do not use this table for 600 Volt in-line applications 100' 150' 200' 250' 300' 350' 400' 4 4 2 2 1 1/0 1/0 4 2 1 1/0 2/0 3/0 3/0 2 1 1/0 2/0 3/0 4/0 4/0 1 1/0 2/0 3/0 4/0 1/0 2/0 3/0 4/0 1/0 3/0 4/0 2/0 3/0 2/0 4/0 3/0 4/0 3/0 4/0 4/0 REQUIRED CABLE SIZES SHOWN IN AWG NUMBERS The total circuit length includes both welding and ground leads (based on 4-volt drop) 60% duty cycle. These values for current-carrying capacity are based on a copper temperature of 60C (140F), an ambient temperature of 40C (104F) and yield load factors of from approximately 32% for the No. 2 AWG cable to approximately 23% for the No. 3/0 AWG cable, and higher for the smaller sizes. The sizes of cables generally used range from No. 2 AWG to No. 3/0 AWG. In actual service, the load factor may be much higher than indicated without overheating the cable as the ambient temperature will generally be substantially lower than 40C. * #6 - #1 AWG: CAROL SUPER VU-TRON(R) WELDING CABLE-EXTRA FLEXIBLE (UL) 600 VOLT (-50C to +90C) OIL RESISTANT P-123-141 MSHA (SIZE) --- CSA 90C ARC WELDING CABLE FT1 MADE IN USA * 1/0 - 4/0 AWG: CAROL SUPER VU-TRON(R) WELDING CABLE (SIZE) EXTRA FLEXIBLE (UL) 600 VOLT (-50C to +90C) OIL RESISTANT P-123-141 MSHA --- CSA 90C ARC WELDING CABLE FT1 --- TYPE RHH OR RHW (UL) 600 V FOR CT USE MADE IN USA Applications: * Secondary voltage resistance welding leads * Power supply applications not exceeding 600 volts AC * Sizes 1/0 and larger for permanent wiring in conduit or tray of 600 V power supplies, hoists, cranes or other applications where flexible power leads must be installed in conduit, raceways or trays Features: * UL Listed * CSA Certified * Excellent flexibility to last longer in flex applications * Abrasion-resistant * Resists oils and solvents * Rated -50C for use in cold environments * Weather-resistant * Ozone-resistant * Safety-colored for high visibility * Assured longer service life, saving money in replacement costs, maintenance cost and downtime * MSHA Approved for flame resistance * Sunlight-resistant Industry Approvals: * UL Listed * CSA Certified * MSHA Approved * Meets UL Vertical Flame Test per UL 854 * RoHS Compliant Packaging: *2 50' (76.2 m), 500' (152.4 m), and 1000' (304.8 m) reels * Other put-ups available on special order Suggested Ampacities For 600 Volt In-Line Applications AWG 4/0 3/0 2/0 1/0 AMPERES 405 350 300 260 AWG 1 2 4 6 AMPERES 220 190 140 105 Appendix J Ampacities for portable cable in accordance with NEC Table 400.5(A)(2). May not be suitable for all installations per National Electrical Code (R). 38