236TD /237 Series - Time Delay Relay DPDT, 10 Amp E13224 Rugged, industrial time delay versions of the popular 219 series. On delay, off delay and interval timing is available. Contacts can be configured up to four pole double throw or six pole single throw. Blow out magnets can be added to increase DC switching capability. Time ranges are adjustable over a 1:100 range. Locking shaft potentiometer and integral hold down clip are standard. A large option list makes this product easily customized for special applications. **Nuclear versions available** GENERAL SPECIFICATIONS (@ 25 C) Timing: Functions Available Time Range Timing Adjustment Timing Repeatability (Constant voltage and temperature) Reset Time maximum Input Pulse Length minimum Contacts: Contact Configuration Contact Material Contact Rating 120 / 240VAC Resistive 28VDC Resistive Motor 120VAC Motor 240VAC Minimum Contct Load Contact Resistance, Initial 10 Amp / 5 Amp 10 Amp 500mW 100 milliohms max @ 6VDC, 1A AC and DC 5VA 2.5W 85% to 110% of nominal 80% to 110% of nominal Yes Yes Continuous Dielectric Strength: Across Open Contacts Between Mutally Insulated Points Insulation Resistance Life Expectancy: Electrical (full load operations) Mechanical (no load operations) Miscellaneous: Mounting Position Mating Socket Accessories Enclosure Weight 7/7 150mS 50mS DPDT, DPDT+NO Silver Alloy Gold Diffused Coil: Coils Available Nominal Coil Power Input Voltage Tolorance -AC Input Voltage Tolorance -DC Transient Protection Reverse Polarity Protection Duty Temperature: Operating Storage On-delay, Off-delay, Interval Up to 7 hours Locking shaft potentiometer 3% 500Vrms 1500Vrms 1,000 Mohms min @ 500VDC -20 to 70C (-4 to 158F) -40 to 105C (-40 to 221F) 100,000 10,000,000 Any 12 pin = 27390D 14 pin = 33377D Hold down clip integral to relay Clear Polycarbonate 8.6oz (244 grams) www.struthers-dunn.com (843) 664-3303 Timer / Sensor - Time Delay & Sensor Relays 5 - 25 Amp Outline Dimensions Dimensions Shown in inches & (millimeters) 120VAC 0.31 (7.95) Series 236 - On delay 237 - Off delay Contact Arrangement ABX (1 N.O. + DPDT) XBX (DPDT) - (2 form C) 4.56 (115.8) Construction Blowout Magnet - CODE 69 Bifurcated contacts CODE 33 Plug-in CODE P Timing Ranges 0.2 - 12 seconds - CODE 012 0.2 - 20 seconds - CODE 020 2.0 - 200 seconds - CODE 200 Fixed = No CODE Adjustment Options Locking shaft potentiometer - No CODE Fixed delay - CODE F (Call for more information) 3.75 (95.2) 7 236/237 Wire Diagram 9 8 2 3 4 12 7- 1 237XBXP 5 10 9 8 7- Timing Modul 1 6+ 2 3 4 5 OFF DELAY 6+ DOUBLE POLE DOUBLE THROW DOUBLE POLE DOUBLE THROW WITH NORMALLY OPEN CONTACT If the jumper wire shown in each diagram is replaced by a resistor, delay time will be added to that which is produced by an internal fixed resistor on fixed time models (Code F) or any setting on screwdriver adjustable models. 11 INPUT Timing Modul 1 2 INPUT 10 3 2.63 (66.8) 237XBXP Jumper or external resistor 12 11 10 9 8 7- Timing Modul 1 2 3 4 5 INPUT 11 4 Section 7 6 Jumper or external resistor Jumper or external resistor 12 5 1.46 (37.2) Operating Voltage AC: 24, 120, 240 (Add VAC) DC: 12, 24, 115-125 (Add VDC) 236ABXP 8 020 9 P 10 ABX 11 236 12 Ordering Code BATCH CONTROL INTERVAL 7 6+ DOUBLE POLE DOUBLE THROW www.struthers-dunn.com (843) 664-3303 7/8