(978)927-1060 FAX (978)922-6430
www.DeltaRF.com
P.O. Box 53 416 Cabot St. Beverly, MA 01915
HN Connectors
Contents
CLICK ON ANY LINE TO GO DIRECTLY TO THE INDICATED PAGE
Navigation Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Specifications and interface dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Design Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
ONLINE CATALOG
Cable Connectors
Straight Cable Plugs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Right Angle Cable Plugs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Straight Cable Jacks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Panel Cable Jacks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Receptacles
Panel Jack Receptacles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Panel Plug Receptacles. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Bulkhead Jack Receptacles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Dummy Receptacles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Accessories
Dust Caps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
In-Series Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Technical Information
Mounting Figures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Cable Groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Cable Assembly Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Ordering and Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Connect Here.
Connect Here.
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 2
Online Catalog Navigation Guide
We have configured this online catalog to take advantage of Acrobat navigation shortcuts (links).
However, these links are not visible on the pages— making them visible would compromise the
page’s readability.
Clicking on any entry in the Table of Contents will take you to the indicated page.
Shown below are the “hot spots” on all of the product pages that will take you to background
information on various connector characteristics.
After you use a link to jump to another page, you can use the “back” arrow in Acrobat’s menu bar
to return to the page you jumped from.
Configure Acrobat Reader to show bookmarks for a table of contents by specific characteristic
(for example, cable plugs broken out by cable attachment method).
To find a specific part number, use Acrobat’s search feature.
In addition, the pages are formatted to fit within the margins of standard laser or inkjet printers—
no need to use the “shrink to fit” option when printing pages from Acrobat.
Click hereto go to the Table of Contents
Panel Jack—Military Clamp for Flexible Cable
Cable Fig. Dimensions Mounting Plating Delta P/N
Group ABC Figure Body Contact
1 1 1.75 .63 .75 33 Nickel Silver 1011-001-N330 A/20
2, 3 1 1.75 .63 .75 33 Nickel Silver 1011-004-N330 A/20
5, 6 2 1.16 .55 .50 07 Nickel Silver UG-291C/U A/17
Figure 1 Figure 2
C dia.
A
B
AB
C dia.
Assembly
Procedure/
Trim Code
Click here to jump to a guide to Delta cable groups.
Click here to jump to dimensions
for Delta mounting figures.
Click here to jump to information on alternate body plating.
Click here to jump to the cable
assembly procedure for this connector.
DELTA ELECTRONICS MANUFACTURING
BNC Cable Jacks
Click on the Delta logo on any page
to jump to the table of contents. Click on the page title to jump to specifications
and interface dimensions.
Click here to go to Delta’s website if your computer is configured for Web connection via Acrobat.
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 3
HN Connectors
General Description
Delta HN series connectors are medium-size, 50impedance connectors with
34
-20 threaded
coupling and good power handling capability. They are best suited for use with cables in the
range of .350" to .450" diameter, but are available for other cables from .200" to over 1"
diameter. Our extensive line of HN receptacles includes configurations for virtually any
packaging requirement, and we can supply any adapter or accessory you need to complete
your system design.
Our HN series product line is still growing, so please call if you don’t see what you need.
For adapters between HN and other series, download the document DeltaABS.pdf
from our website.
Electrical:
Nominal Impedance: 50 ohms.
Frequency Range: DC–4 GHz.
Voltage Rating: 1,500 volts RMS.
Dielectric Withstanding Voltage: 5,000 VRMS.
Insulation Resistance: 5,000 megohms.
Materials/Finishes:
Insulators: Teflon per ASTM D1710, or
Rexolite per MIL-P-77.
Male Contacts: Brass per ASTM B16.
Female Contacts: Beryllium Copper per
ASTM B196.
Contact Plating: Silver per QQ-S-365, or
Gold per MIL-G-45204.
Gaskets: Silicone rubber per ZZ-R-765,
Class II, Grade 50.
Other Metal Parts: Brass per ASTM B16, plated:
Silver per QQ-S-365, or
Nickel per QQ-N-290.
All other specifications are in accordance
with the latest issues of MIL-PRF-39012, or
MIL-C-3643, or other applicable MIL
specifications, and interfaces are in
accordance with MIL-STD-348.
*These specifications are typical and may not apply to
all connectors. Detailed specifications for individual
connectors are available on request.
HN Specifications*
Reference
Plane
.058 max.
.005 min.
.100 min.
.358
.388
.368 min.
.138 min.
.120 min.
.750-20 UNEF-2B,
.403 min. full thread
.760
min.
Flare
to meet
gage test
*See
below
*.432 minimum I.D. when inserted
into .548 dia. ring gage.
.132
max.
.925
max. .289
min.
.263
min.
.062
.066
Plug Interface**
.077/.087 .516
.522
.328
.358
.368
max.
.005 max.
.590
min.
.750-20 UNEF-2A,
.359 min. full thread
Reference
Plane
.755 max.
.430 max.
.571/.578
I.D. to meet
performance
requirements
when mated
with .062/.066 pin
.132
max.
.548
.553
.662/.683
.268 max. .294 max.
Jack Interface**
**Some proportions altered to illustrate detail.
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 4
Design Features
About Delta’s Customer-Driven Design
At Delta, Customer-Driven Design isn’t just a catchy slogan. It means that we make RF
connectors that help you build your products efficiently, quickly, and cost-effectively. Because
we design for your needs, nobody else can offer you such a broad line of standard connectors,
along with an ever-growing list of innovative, user-friendly design variations like those detailed
on these pages.
These featured connector technologies grew out of real-world requirements, and have saved
our customers untold hours and dollars over the years. And there are thousands of other
special connector designs we’ve produced that we don’t have space to include in this catalog.
So if you don’t see the exact connector configuration you need, please call us—we may have
already made it. If not, we’ll work with you to provide the the connectors you need, with the
best price/performance balance in the business, and with quality and delivery that will enhance
your products and production schedules.
Plating Options for Economy and Performance
(Albaloy or nickel—available for all connector series except SMA)
Silver plating has long been standard on RF connectors with brass bodies, but its high cost
and low corrosion resistance make it less than ideal in most applications. Nickel plating is
less expensive and more durable than silver, and is standard on many of our connectors.
However, in some applications, nickel plating can introduce unwanted intermodulation dis-
tortion, particularly on large size connectors. For these applications, we offer optional
Albaloy plating, a tin/zinc/copper composite with a bright white finish, the corrosion resis-
tance of nickel, and the low intermodulation distortion of silver plating.
Albaloy plating has the same composition as, and is fully compatible with, other commer-
cial platings designated Sucoplate®
,IP-23, White Bronze, and Tri-Alloy.
To order a Delta connector with plating other than the listed finish, substitute
A, N, or Qin the Delta part number as below:
For silver plating: 1111-111-A111.
For nickel plating: 1111-111-N111.
For Albaloy plating: 1111-111-Q111.
Note: M39012 and M55339 QPL connectors can only be supplied with the
specified plating. SMA connectors with stainless-steel bodies are available
with gold plating or passivated finish.
Straight Plug—Military Clamp for Flexible Cable
Cable Figure Dimensions Plating Delta P/N Assembly Procedure/
Group A B Body Contact Trim Code
2, 3 1 2.38 .69 Nickel Silver UG-59B/U ***
2, 3 1 2.25 .75 Nickel Silver UG-59E/U A/26
2, 3 1 2.81 .69 Nickel Silver (C)UG-1213/U ***
4 1 2.23 .75 Nickel Silver (C)1601-079-N001 ***
5, 6 2 1.50 .50 Nickel Silver 1601-015-N000 A/17
15 3 2.84 .75 Nickel Silver UG-925B/U D/05
16 1 2.41 .88 Nickel Silver UG-494B/U A/27
17 1 2.59 1.31 Nickel Silver UG-495D/U A/28
17 3 3.53 1.31 Nickel Silver UG-1148/U ***
20 3 3.20 1.31 Nickel Silver UG-926A/U D/06
Figure 1 Figure 2
A
B dia.
A
B dia.
Figure 3 (Includes armor clamp)
Right Angle Plug—Military Clamp for Flexible Cable
Cable Figure Dimensions Plating Delta P/N Assembly Procedure/
Group A B C Body Contact Trim Code
2, 3 1 1.73 1.63 .75 Nickel Silver (C)1605-004-N001-2 A/29
2, 3 2 1.53 2.25 .69 Nickel Silver (C)1604-004-N001 ***
2, 3 2 1.56 2.48 .75 Nickel Silver 1604-005-N000 A/27
4 2 1.56 2.48 .75 Nickel Silver (C)1604-079-N001-1 ***
15 3 1.56 3.05 .75 Nickel Silver 1604-006-N000 D/05
Figure 1 Figure 2
A
B
C dia.
A
B
C dia.
A
B
C dia.
Figure 3
(Includes
armor clamp)
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 5
HN Cable Plugs
***Contact factory for cable assembly instructions. (C) in contact plating column indicates captive contact.
Panel Jack—Military Clamp for Flexible Cable
Figure 1
AB
C dia.
Cable Fig. Dimensions Mounting Plating Delta P/N
Group ABC Figure Body Contact
2, 3 1 2.53 .59 .69 40 Nickel Silver UG-61B/U ***
2, 3 1 2.03 .59 .75 40 Nickel Silver UG-61E/U A/26
2, 3 1 2.03 .59 .75 36 Nickel Silver UG-427C/U A/26
Assembly
Procedure/
Trim Code
Straight Jack—Military Clamp for Flexible Cable
Cable Figure Dimensions Plating Delta P/N Assembly Procedure/
Group A B Body Contact Trim Code
2, 3 1 2.53 .69 Nickel Silver UG-60B/U ***
2, 3 1 2.03 .75 Nickel Silver UG-60E/U A/26
2, 3 1 2.94 .69 Nickel Silver (C)UG-1214/U ***
15 2 2.63 .75 Nickel Silver UG-927B/U D/05
17 1 2.53 1.31 Nickel Silver UG-333C/U A/28
Figure 1
A
B dia.
A
B dia.
Figure 2
(Includes armor clamp)
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 6
HN Cable Jacks
(C) in contact plating column indicates captive contact. ***Contact factory for cable assembly instructions.
Panel and Bulkhead Receptacles
Figure Dimensions Mounting Plating Delta P/N
ABCD Figure Body Contact
1 1.50 .59 .106 .080 40 Nickel Silver (C)UG-496/U
2 1.88 .94 .106 .080 40 Nickel Silver (C)1623-000-N401
3 1.55 .89 .106 .25 69 Nickel Silver (C)1621-000-N691
4 .875 .125 .. 34* Nickel 1663-000-N340
Figure 1
(Panel jack receptacle)
Figure 4
(Dummy receptacle)
Figure 2
(Panel plug receptacle)
C (I.D.)
AB
D
C (I.D.)
AB
D
A
B
Figure 3
(Bulkhead jack receptacle)
1" hex
AB
D max. panel
C (I.D.)
* Except mounting holes are .120 diameter.
Dust Caps
A
B
C (I.D.)
A
B
C (I.D.)
Figure Dimensions Features Plating Delta P/N
A B C Body Contact
1 .70 3.50 .144 Bead chain Nickel 1632-000-N000
2 .70 3.50 .144 Bead chain Nickel 1633-000-N000
Figure 1 Figure 2
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 7
HN Receptacles/Accessories
(C) in contact plating column indicates captive contact. Dust caps available with other chain styles and lengths.
Bulkhead Jack–Jack Adapter
Dimensions Max. Mounting Plating Delta P/N
ABC
Panel Figure Body Contact
1.94 1.06 1.06 .25 69 Nickel Silver (C)UG-1019A/U
C dia.
AB
(Connects two plugs,
pressurized)
Straight Adapters
Figure Dimensions Plating Delta P/N
A B Body Contact
1 2.00 . Nickel Silver (C)1628-000-N000
2 1.63 .75 Nickel Silver (C)1634-000-N001
3 1.94 . Nickel Silver (C)1627-000-N000
A
A
A
B across flats
Figure 1
(Straight jack–jack;
connects two plugs)
Figure 3
(Straight plug–plug;
connects two jacks)
Figure 2
(Straight plug–jack; connects one
plug and one jack)
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 8
HN Adapters
(C) in contact plating column indicates captive contact.
Right Angle and Tee Adapters
Figure Dimensions Plating Delta P/N
A B Body Contact
1 1.50 1.38 Nickel Silver (C)UG-212C/U
2 1.63 1.63 Nickel Silver (C)1637-000-N000
3 1.94 1.88 Nickel Silver (C)1630-000-N000
4 1.94 1.28 Nickel Silver (C)1638-000-N000
5 2.33 1.50 Nickel Silver (C)UG-1109/U
A
B
A
B
A
B
A
B
Figure 1
(Right angle jack–plug; connects
one plug and one jack) Figure 2
(Right angle plug–plug;
connects two jacks)
Figure 3
(Tee jack–plug–jack; connects
two plugs and one jack)
Figure 4
(Tee jack–jack–jack;
connects three plugs)
A
B
Figure 5
(Tee plug–jack–plug; connects
two jacks and one plug)
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 9
HN Adapters
(C) in contact plating column indicates captive contact.
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 10
Mounting Figures
Connector Flanges
(Panel mounted connectors)
4-hole flanges
Figure AB C
04 1/2.360 .089
05 1/2.340 .102
07 11/16 .500 #3-56 tap
08 11/16 .500 .136
09 11/16 .500 .125
10 11/16 .500 .120
12 11/16 .500 .109
18 3/4.531 .136
26 1 .718 #6-32 tap
27 1 .718 #4-40 tap
30 1 .718 .166
32 1 .718 .136
32A 1 .718 .136*
33 1 .718 .125
34 13/32 .812 .150
36 13/16 .906 #6-32 tap
39 13/16 .906 .152
40 13/16 .906 .125
45 2 1.437 .257
91 .375 .250 .067
91A .375 .232 .093
A
square
C dia. typ.
B
(L) typ.
C
A
D
dia. typ.
B (L)
C
C
* Countersunk to .245 dia.
2-hole flanges
Figure ABCD
92 .223 .481 .625 .102
92A .260 .481 .625 .102
95 .640 1.015 1.30 .125
Panel Cutouts
(Bulkhead mounted connectors)
D-Hole
Figure A B
51 .755 .723
54 .630 .598
55 .630 .583
57 .557 .531
59 .505 .473
62 .442 .410
63 .407 .362
65 .380 .348
66 .319 .292
67 .255 .236
68 .195 .176
Double D-Hole
Figure A B
69 .755 .692
72 .630 .536
75 .380 .341
84 .319 .278
B
A dia.
B
A dia.
Round Hole
Figure A
82 .255
89 .380
A dia.
P.C. Board Drilling
Twinax connectors
Figure A B C D
PCB04 .045 .500 .250 .045
A dia. typ.
D
dia.
B (L) typ.
C
C (L) typ.
C
A dia. typ.
.0625 typ.
D
dia.
typ.
B (L) typ.
C
C (L) typ.
C
.125 (L)
C
Coaxial connectors
Figure ABCD
PCB01 .067 .400 .200 .045
PCB02 .045 .500 .250 .045
PCB03 .067 .300 .150 .035
PCB05 .067 .200 .100 .055
PCB06 .067 .200 .100 .045
PCB07 .045 .177 .088 .045
PCB08 .032 .100 .050 .032
(PCB traces are shown for illustrative purpose only,
and are not representative of actual circuitry.)
(PCB traces are shown for illustrative purpose only,
and are not representative of actual circuitry.)
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 11
Cable Groups
Delta Cable Groups
Group
Cables
1A RG-5, 5A, 5B, 21, 21A; M17/73, /162
1 1B RG-6, 6A; M17/2
1C RG-143, 143A, 212, 222; M17/73, /112, /162
22A RG-8, 8A, 213; M17/74
2B RG-11, 11A; M17/6
3A RG-9, 9A, 9B, 214; M17/75
3 3B RG-13A, 216; M17/77
3C RG-225; M17/127
4 RG-393; M17/127
5 RG-58, 58A, 58C, 141, 141A; M17/28, /111
66A RG-55A, 142, 142A, 223, 400; M17/60, /84, /128
6B RG-55, 55B, 142B; M17/60, /84
77A
RG-59, 59A, 59B, 62, 62A, 62B, 62C, 210; M17/29, /30, /97
7B RG-71, 71A, 71B; M17/90
88A RG-122; M17/54
8B RG-180, 180A, 180B, 195; M17/95, /137
99A RG-174, 188, 188A, 316; M17/152
9B RG-179A, 179B, 187, 187A; M17/94, /136
10 Double-Shielded RG-174, 316; M17/152
11 RG-178, 178A, 178B, 196, 196A; M17/93
12 .250" semi-rigid; RG-401; M17/129
13 .141" semi-rigid; RG-402; M17/130
14 .085" semi-rigid; RG-405; M17/133
15 RG-10, 12, 215; M17/6, /74
16 RG-14A, 217; M17/78, /165
17 RG-17A, 218
18 RG-18A, 219
19 RG-115A
20 RG-118A, 228A
21 RG-126
22 RG-302
23 RG-303
24 RG-304
25 Special 8X cable; contact factory for details.
26 Belden 8281
27 RG-108, 108A; M17/45
28 RG-22, 22A, 22B; M17/15
29 Belden 9207; Dearborn 6207; IBM 7362211
30 M17/176
31 AT&T 735A
RG-5, 5A, B 1A
RG-6, 6A 1B
RG-8, 8A 2A
RG-9, 9A, B 3A
RG-10 15
RG-11, 11A 2B
RG-12 15
RG-13A 3B
RG-14A 16
RG-17A 17
RG-18A 18
RG-21, 21A 1A
RG-22, 22A, B 28
RG-55, 55B 6B
RG-55A 6A
RG-58, 58A, C 5
RG-59, 59A, B 7A
RG-62, 62A, B, C 7A
RG-71, 71A, B 7B
RG-108, 108A 27
RG-115A 19
RG-118A 20
RG-122 8A
RG-126 21
RG-141, 141A 5
RG-142, 142A 6A
RG-142B 6B
RG-143, 143A 1C
RG-174 9A
RG-174DS 10
RG-178, 178A, B 11
RG-179A, 179B 9B
RG-180, 180A, B 8B
RG-187, 187A 9B
RG-188, 188A 9A
RG-195 8B
RG-196, 196A 11
RG-210 7A
RG-212 1C
RG-213 2A
RG-214 3A
RG-215 15
RG-217 16
RG-218 17
RG-219 18
RG-222 1C
RG-223 6A
RG-225 3C
RG-228A 20
RG-302 22
RG-303 23
RG-304 24
RG-316 9A
RG-316DS 10
RG-393 4
RG-400 6A
RG-401 12
RG-402 13
RG-405 14
M17/2 1B
M17/6 2B
M17/15 28
M17/28 5
M17/29 7A
M17/30 7A
M17/45 27
M17/73 1A
M17/162 1A
M17/112 1C
M17/74 2A
M17/75 3A
M17/127 3C
M17/77 3B
M17/60 6A
M18/84 6A
M17/128 6A
M17/97 7A
M17/54 8A
M17/95 8B
M17/137 8B
M17/152 9A
M17/93 11
M17/129 12
M17/130 13
M17/133 14
M17/78 16
M17/165 16
M17/176 30
AT&T 735A 31
Belden 8281 26
Belden 9207 29
Dearborn 6207 29
IBM 7362211 29
Cable Group Finder
Cable
Group
Cable
Group
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 12
Assembly Procedures
Assembly Procedure A
1) Trim cable jacket to dimension A.
Slide backnut, washer, V-gasket, and
braid clamp onto cable as shown.
Cable jacket should bottom on step
in braid clamp.
2) Comb braid wires out straight and fold back over front
shoulder of braid clamp (braid wires should not overlap
one another after folding). Trim braid wires flush with step
of braid clamp. Trim cable dielectric and center conductor
to dimensions B and C.
3) If support insulator is provided for RG-62 or 71 cable, insert
into hollow in dielectric. Assemble rear bushing or washer (if
supplied), rear insulator (if captive contact) and contact, and
solder contact to center conductor. Rear of contact should be
flush with cable dielectric end. For right angle connectors
with access cap, omit this step entirely.
4) Insert prepared cable and hardware into body
and tighten backnut. For right angle connectors
with access cap, solder center conductor into slot
in contact and tighten access cap.
Code A B C
A/01 .375 (3/8) .047 (3/64) .203 (13/64)
A/02 .375 (3/8) .109 (7/64) .203 (13/64)
A/03 .438 (7/16) .250 (1/4) .188 (3/16)
A/04 .281 (9/32) .047 (3/64) .125 (1/8)
A/05 .313 (5/16) .125 (1/8) .109 (7/64)
A/06 .594 (19/32) .391 (25/64) .156 (5/32)
A/07 .375 (3/8) .047 (3/64) .125 (1/8)
A/08 .281 (9/32) .109 (7/64) .094 (3/32)
A/09 .344 (11/32) .109 (7/64) .094 (3/32)
A/10 .406 (13/32) .109 (7/64) .203 (13/64)
A/11 .500 (1/2) .281 (9/32) .156 (5/32)
A/12 .343 .040 .219
A/13 .375 (3/8) .125 (1/8) .156 (5/32)
A/14 .355 .090 .188 (3/16)
A/15 .425 .094 (3/32) .259
A/16 .328 (21/64) .094 (3/32) .188 (3/16)
A/17 .375 (3/8) .109 (7/64) .125 (1/8)
A/18 .375 (3/8) .062 (1/16) .172 (11/64)
A/19 .375 (3/8) .188 (3/16) .094 (3/32)
Code A B C
A/20 .375 (3/8) .047 (3/64) .172 (11/64)
A/21 .500 (1/2) .313 (5/16) .172 (11/64)
A/22 .375 (3/8) .188 (3/16) .141 (9/64)
A/23 .438 (7/16) .078 (5/64) .172 (11/64)
A/24 .500 (1/2) .094 (3/32) .141 (9/64)
A/25 .438 (7/16) .141 (9/64) .172 (11/64)
A/26 .625 (5/8) .281 (9/32) .250 (1/4)
A/27 .688 (11/16) .281 (9/32) .125 (1/8)
A/28 .656 (21/32) .297 (19/64) .250 (1/4)
A/29 .688 (11/16) .125 (1/8) .313 (5/16)
A/30 .688 (11/16) .469 (15/32) .156 (5/32)
A/31 .700 (21/32) .453 (29/64) .250 (1/4)
A/32 .313 (5/16) .078 (5/64) .188 (3/16)
A/33 .250 (1/4) .078 (5/64) .094 (3/32)
A/34 .250 (1/4) .062 (1/16) .109 (7/64)
A/35 .837 .575 .150
A/36 .450 .250 .150
A/37 .281 .038 .188
A/38 .281 .069 .156
Trim Codes For Assembly Procedure A
Backnut Washer
(if supplied)
V-Gasket Braid Clamp
A
Washer and/or bushing
(if supplied)
Contact
(non-captive)
or
Contact (captive)
& insulator
Fold braid over
B
C
Non-captive Contact
Solder
Solder
Captive Contact
Washer or bushing (if supplied)
DELTA ELECTRONICS MANUFACTURING
(978)927-1060 • FAX (978)922-6430 • www.deltarf.com 13
Assembly Procedures
Ordering and Warranty Information
Warranty: We warrant our parts to be free from defects in materials and workmanship for one year from date of
purchase. During that time, we will repair or replace (at our option) any parts found to be defective.
This warranty does not apply to parts which have been modified, used in conditions exceeding Delta or military
specifications, or disassembled. We will not, under any circumstances, be responsible for consequential or incidental
damages or installation costs.
No other warranties apply, and no other liability may be assumed or extended by representatives or distributors.
Returns: Returns will be accepted only with a Return Authorization number issued by Delta, and are subject to
inspection and acceptance upon arrival. Restocking charges will be determined prior to issuance of Return
Authorization.
All claims for shortages must be made within 30 days of receipt by customer.
Ordering Information: Orders are subject to the terms and conditions on our order acknowledgement, which
may only be modified by written agreement prior to sale. Order changes, cancellation, or termination will be
accepted only with written approval from Delta Electronics Manufacturing.
Copyright, Trademarks, and Patents: Entire contents copyright 2003, Delta Electronics Manufacturing
Corporation. Reproduction rights are hereby granted for, and specifically limited to, printing or other reproduction
of drawings and specifications for inclusion in specification or source control drawings, or for purchasing procedures,
by Delta customers only. Heli-Grip, PressMount, and the New England Craftsmanship logo are trademarks.
The Heli-Grip design is covered by U.S. and foreign patents.
Delta Electronics Manufacturing Corporation
416 Cabot Street, P.O. Box 53
Beverly, MA 01915
FSCM/CAGE 00795
Catalog # HNpdf 1.2 (7/09)
Assembly Procedure D
V-Gasket
Backnut Washer
Braid Clamp
Contact (captive)
& insulator
Contact
(non-captive)
Fold braid over
A
B
C
or
Armor Clamp
Non-captive
Captive
Solder
1) Slide armor clamp over cable. Push
armor back to expose cable end.
Slide backnut, washer (if supplied),
gasket, and braid clamp onto cable
as shown. Cable jacket should
bottom on step in braid clamp.
Trim cable jacket to dimension A.
2) Comb braid wires out straight and fold back over
front shoulder of braid clamp (braid wires should
not overlap one another after folding). Trim braid
wires flush with edge of braid clamp. Trim cable
dielectric and center conductor to dimensions B
and C.
3) Assemble rear insulator (if captive contact) and
contact, and solder contact to center conductor.
Rear of contact should be flush with cable
dielectric end.
4) Insert prepared cable and hardware into body and tighten backnut.
Trim armor to fit between armor clamp and braid clamp. Tighten armor clamp.
Trim Codes
Code A B C
D/01 .375 (3/8) .047 (3/64) .250 (1/4)
D/02 .500 (1/2) .188 (3/16) .219 (7/32)
D/03 .344 (11/32) .047 (3/64) .219 (7/32)
D/04 .313 (5/16) .047 (3/64) .172 (11/64)
D/05 .625 (5/8) .281 (9/32) .250 (1/4)
D/06 .313 (5/16) .062 (1/16) .109 (7/64)