220W AC-DC High Reliability Industrial Adaptor UL62368-1 EN62368-1 J60950-1 R33100 RoHS AS/NZS60950-1 GST220A series GB4943.1 THOMAS SAMUEL THOMAS SAMUEL MS IEC60950-1 IS13252 K60950-1 TPTC004 (optional) (except for 36V) (except for 36V) (except for 36V) (except for 36V) IEC62368-1 Features Global certificates Universal AC input / Full range 3 pole AC inlet IEC320-C14,Classpower unit Built-in active PFC function No load power consumption<0.15W Energy efficiency Level VI Comply with EISA 2007/DoE,NRCan,AU/NZ MEPS, Applications Consumer electronic devices Telecommunication devices Office facilities Industrial equipments EU ErP and CoC Version 5 Protections: Short circuit / Overload / Over voltage /Over temperature Fanless design with -30~+70 working temperature Fully enclosed plastic case LED indicator for power on 3 years warranty Description GST220A is a highly reliable, 220W desktop style single-output green adaptor series. This product is a classpower unit (with FG), equipped with a standard IEC320-C14 AC inlet and adopting the input range from 85VAC to 264VAC. The entire series supplies different models with output voltages ranging between 12VDC and 48VDC that can satisfy the demands for various types of consumer electronic devices. With the efficiency up to 94.5% and the extremely low no-load power consumption below 0.15W, GST220A is compliant with USA EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, Korea K-MEPS, EU ErP and Code of Conduct (CoC) Version 5. The supreme feature allows the adaptor to save the energy when it is either under the operating mode or the standby mode. The entire series utilizes the 94V-0 flame retardant plastic case.GST220A is certified for the international safety regulations. Model Encoding GST 220 A 12 - R7B DC plug type { R7B: Standard model,Power DIN 4Pin with lock type Other options available by customer requested (see Page 4~5) Output voltage IEC320-C14 AC inlet Rated wattage Series name File Name:GST220A-SPEC 2019-05-20 GST220A 220W AC-DC High Reliability Industrial Adaptor series SPECIFICATION ORDER NO. SAFETY MODEL NO. DC VOLTAGE OUTPUT GST220A20-R7B GST220A24-R7B GST220A36-R7B GST220A48-R7B GST220A12 GST220A15 15V GST220A20 20V GST220A24 24V GST220A36 36V GST220A48 48V Note.2 12V 15A 13.4A 11A 9.2A 6.1A 4.6A CURRENT RANGE 0 ~ 15A 0 ~ 13.4A 0 ~ 11A 0 ~ 9.2A 0 ~ 6.1A 0 ~ 4.6A RATED POWER (max.) 180W 201W 220W 221W 219.6W 221W 100mVp-p 120mVp-p 150mVp-p 200mVp-p 200mVp-p VOLTAGE TOLERANCE Note.4 5.0% 5.0% 4.0% 3.0% 2.0% 2.0% Note.5 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 5.0% 5.0% 4.0% 3.0% 2.0% 2.0% 93.5% 93% 94.5% RIPPLE & NOISE (max.) Note.3 80mVp-p LOAD REGULATION SETUP, RISE TIME Note.6 2000ms, 50ms / 230VAC HOLD UP TIME (Typ.) VOLTAGE RANGE Note.7 85 ~ 264VAC 20ms / 230VAC 2000ms, 50ms / 115VAC at full load 20ms / 115VAC at full load 120 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.91 / 230VAC EFFICIENCY (Typ.) 90% AC CURRENT (Typ.) INRUSH CURRENT (max.) 4A / 115VAC 2A / 230VAC Cold start 95A / 115VAC 120A / 230VAC LEAKAGE CURRENT(max.) OVERLOAD PROTECTION GST220A15-R7B RATED CURRENT LINE REGULATION INPUT GST220A12-R7B OVER VOLTAGE PF>0.98 / 115VAC at full load 92% 90% 0.75mA / 240VAC 105 ~ 135% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 105 ~ 135% rated output voltage OVER TEMPERATURE Protection type : H iccup mode @ 10%load Shut down o/p voltage, recovers automatically after temperature goes down WORKING TEMP. WORKING HUMIDITY -30 ~ +70 (Refer to "Derating Curve") 20% ~ 90% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION -40 ~ +85, 10 ~ 95% RH non-condensing 0.03% / (0~50) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL62368-1, CSA C22.2 No.62368-1, TUV EN62368-1, BSMI CNS14336, CCC GB4943.1, PSE J60950-1,AS/NZS 60950.1 , SAFETY STANDARDS Note. 8 BIS IS13252, KC K60950-1, EAC TP TC 004 approved; SIRIM MS IEC60950-1 (optional) approved (UL62368-1, CSA C22.2 No.62368-1, TUV EN62368-1, BSMI CNS14336, CCC GB4943.1, PSE J60950-1,AS/NZS 60950.1 for GST220A36-R7B) WITHSTAND VOLTAGE ISOLATION RESISTANCE I/P-O/P: 3KVAC I/P-FG: 2KVAC O/P-FG:SHORT I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH Standard EN55032(CISPR32),FCC PART 15 / CISPR22 CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1 EAC TP TC 020,MSIP KN32 EN55032(CISPR32),FCC PART 15 / CISPR22 CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1 EAC TP TC 020,MSIP KN32 EN61000-3-2,GB9254 Test Level / Note Parameter EN61000-3-3 Standard ESD RF field susceptibility EN61000-4-2 EN61000-4-3 ------Test Level /Note Level 4, 15KV air; Level 4, 8KV contact EFT bursts EN61000-4-4 Level 2, 1KV Surge susceptibility Conducted susceptibility Level 3, 1KV/Line-Line , 2KV/Line-FG Magnetic field immunity EN61000-4-5 EN61000-4-6 EN61000-4-8 Voltage dips , interruption EN61000-4-11 Parameter Conducted emission EMC EMISSION SAFETY & EMC (Note. 9) Harmonic current Voltage flicker EMC IMMUNITY OTHERS CONNECTOR NOTE Radiated emission PACKING PLUG 209.4K hrs min. MIL-HDBK-217F(25) 210*85*46mm (L*W*H) 1.1Kg; 12pcs/14.2Kg/0.96CUFT See page 4~5 ; Other type available by customer requested CABLE See page 4~5 ; Other type available by customer requested MTBF DIMENSION Class B Class B Class A Level 2, 3V/m Level 2, 3V Level 2, 3A/m 95% dip 0. 5 periods, 30% dip 25 periods, 95% interruptions 250 periods 1. All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. 2. DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1f & 47f capacitor. 4. Tolerance: includes set up tolerance, line regulation, load regulation. 5. Line regulation is measured from low line to high line at rated load. 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. Derating may be needed under low input voltage. Please check the derating curve for more details. 8. The demand for Malaysia safety is processed with the order no. GST220A -SIRIM by request. Please contact MEAN WELL for details. 9. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on http://www.meanwell.com) File Name:GST220A-SPEC 2019-05-20 GST220A 220W AC-DC High Reliability Industrial Adaptor Derating Curve series Static Characteristics 100 230VAC 100 90 For others 80 80 100VAC for others 110VAC for 12~15V 40 20 -30 10 0 20 30 40 50 For 12~15V 70 50 LOAD (%) LOAD (%) 60 60 70 (HORIZONTAL) 60 50 40 85 90 95 100 AMBIENT TEMPERATURE () 110 120 140 160 180 200 220 240 INPUT VOLTAGE (VAC) 60Hz Mechanical Specification Case No. 961A 46 264 Unit:mm 210 UL2464 16AWGx4C 100050mm 303mm 85 Power LED AC Inlet IEC320-C14 DC output plug Standard plug: R7B R7B Pin Assignment 2 1 2 3 1 4 KYCON KPPX - 4P equivalent 3 4 AC FG -V connected to AC FG PIN NO. OUTPUT 1 +Vo 2 -Vo 3 -Vo 4 +Vo File Name:GST220A-SPEC 2019-05-20 220W AC-DC High Reliability Industrial Adaptor GST220A series Optional DC plug: Type No. Min. DIN 4 Pin with Lock (female) R7BF 23 14 KYCON KPJX-CM-4S equivalent DIN 5 Pin (male) Type No. R1B 3 1 4 2 5 NEUTRIK XLR NC4FX equivalent 4 3 Type No. 1 MIC4 2 MOLEX 39-01-2060 (4.2mm) equivalent 4 5 6 1 2 3 Type No. C6P Type No. AMP 1-480702-0 (6.35mm) equivalent 4 3 2 1 C4P Stripped and tinned leads Type No. L Pin Assignment Output PIN No. +Vo 1 -Vo 2 3 -Vo 4 +Vo Pin Assignment Output PIN No. -Vo 1 -Vo 2 3 +Vo -Vo 4 5 +Vo Pin Assignment Output PIN No. +Vo 1 +Vo 2 3 -Vo -Vo 4 Pin Assignment Output PIN No. +Vo 1 +Vo 2 3 +Vo -Vo 4 5 -Vo 6 -Vo Pin Assignment Output PIN No. +Vo 1 +Vo 2 3 -Vo 4 -Vo Pin Assignment Output PIN No. (red,blue) 1 2 L1 (black,white) Length of Land L1 by request 1 +Vo 2 -Vo by customer ( MW's standard length, L: 25 mm, L1: 5 mm) Installation Manual Please refer to : http://www.meanwell.com/manual.html File Name:GST220A-SPEC 2019-05-20