Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview...................................................................................................................................... 2 ESB Installation Contactors 20 A / AC-1/AC-7a ESB20 .................................................................................................... 4 24 A / AC-1/AC-7a ESB24 .................................................................................................... 5 40 A / AC-1/AC-7a ESB40 .................................................................................................... 6 63 A / AC-1/AC-7a ESB63 .................................................................................................... 7 Main Technical Data ................................................................................................................... 8 Lighting application .................................................................................................................. 13 EN Installation Contactors - Manually/Automatic Operated 20 A / AC-1/AC-7a EN20 ................................................................................................... 14 24 A / AC-1/AC-7a EN24 .................................................................................................... 15 40 A / AC-1/AC-7a EN40 .................................................................................................... 16 Main Technical Data ................................................................................................................. 17 ESB/EN Installation Contactors Main Accessories ..................................................................................................................... 19 1SBC103011S0201 Index .......................................................................................................................................... 20 ABB | 1 Modular DIN rail components Installation Contactors ESB and EN All over the world, commercial and industrial buildings such as hospitals, hotels, shopping and sport centers, domestic and residential installation are equipped with ABB low voltage products and systems. From switchboard to light switch, ABB covers the complete range of equipment required for controlling and protecting electrical installations. Typical segments 1-2 Residential installations | 3 Hotels 1 2 | ABB 2 3 For controlling and remote switching, ABB offers a complete range of installation contactors that are mainly used in the following applications: s Lighting s Heating s Ventilation s Pumps and motors. ESB and EN installation contactors are designed to match the Modular DIN rail components for common use in dedicated panels. The ESB range includes 4 ratings from 20 A to 63 A with 2 to 4-pole version. The EN range includes 3 ratings from 20 A to 40 A. Many contacts variations are available for managing all application. Products comply with standards IEC60947-4-1 and IEC61095. Construction: The ESB20, EN20 operates with an AC solenoid system. Types ESB24...63, EN24...40 are fitted with a DC solenoid actuator and are therefore hum-free. The noise during switching is barely audible making it beneficial for use in buildings such as hospitals, hotels or houses. An incorporated varistor protects the coil against remote lightning strikes and overvoltages up to 5 kV. In addition, it limits the interference voltage peaks of the solenoid system. The contactors can therefore be combined with programmable logic controllers. There is no need for a protective circuit. The solenoid system is provided with radio interference suppression. Accessories are available, such as auxiliary contacts and sealing covers. ESB advantages: s Powerful for lamp switching s Operation flag indicator s DC coil: - Noiseless and hum free - Low power consumption - Integrated overvoltage protection. The EN contactors have a built-in toggle switch for automatic and manual operation. EN advantages: s Facilitate commissioning s Functional test before start-up s Ease maintenance operation s High degree of safety and availability in case of automation system failure. 4 Shopping centers | 5 Hospitals | 6 Commercial & industrial buildings 4 5 6 ABB | 3 20 A AC-1/AC-7a ESB20 Installation Contactors AC Operated Application Certifications and Approvals The ESB contactors are used mainly in buildings for switching and controlling lighting, heating, ventilation and pumps. They are part of the complete range of Din rail products and can be integrated easily in dedicated panels. UL CSA CCC RMRS CE BV Description The ESB20 contactors are used for the control of single phase loads up to 20 A. They operate with an AC coil. You can choose between a various N.O. and N.C. contacts combination. Ordering Details Main poles A1 1 3 A2 2 4 Nb of Control coil voltage modules 50 Hz 60 Hz Type Order code Pack(ing) Weight pieces kg (1 pce) 1 ESB20-20 GHE3211102R1004 GHE3211102R1005 GHE3211102R0001 GHE3211102R0002 GHE3211102R0003 GHE3211102R0004 GHE3211102R0006 GHE3211102R0005 GHE3211102R0007 GHE3211202R1004 GHE3211202R1005 GHE3211202R0001 GHE3211202R0002 GHE3211202R0003 GHE3211202R0004 GHE3211202R0006 GHE3211202R0005 GHE3211202R0007 GHE3211302R1004 GHE3211302R1005 GHE3211302R0001 GHE3211302R0002 GHE3211302R0003 GHE3211302R0004 GHE3211302R0006 GHE3211302R0005 GHE3211302R0007 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 12 V 20 V 24 V 42 V 48 V 110 V 230 V 240 V 400 V 12 V 20 V 24 V 42 V 48 V 110 V 230 V 240 V 400 V 12 V 20 V 24 V 42 V 48 V 110 V 230 V 240 V 400 V 2 N.O. A1 R1 R3 A2 R2 R4 1 2 N.C. A1 1 R3 A2 2 R4 1 1 N.O. 1 N.C. 14 V 24 V 28 V 48 V 55 V 125...127 V 264 V 278 V 14 V 24 V 28 V 48 V 55 V 125...127 V 264 V 278 V 14 V 24 V 28 V 48 V 55 V 125...127 V 264 V 278 V - ESB20-02 ESB20-11 Main Technical Data Main poles acc to. IEC 60947-4-1 and IEC 61095 Magnet system Connecting capacity Mounting positions Pos. 2 +30 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 For complete technical data see 1SBC103005S0201.pdf Rated operational voltage Ue Ie AC-1 / AC-7a Rated operational current (for air temperature close to contactor 55C) AC-3 / AC-7b Ratings (for air temperature close to contactor 55C) Rated operational power 1 phase 230 V 1 phase Ie Rated operational current 230 V Coil operating limits (acc. to IEC 60947-4-1) Average pull-in coil consumption value Average holding coil consumption value Main pole terminals Rigid Coil terminals Rigid -30 59 2.32" 250 V 20 A 1.1 kW 9A 0.85 ... 1.1 Uc (at 55C) 8 VA / 5 W 3.2 VA / 1.2 W 1 x 1.5 ... 10 mm2 2 x 1.5 ... 4 mm2 1 x 0.5 ... 4 mm2 2 x 0.75 ... 2.5 mm2 17.5 0.69" Pos. 4 Pos. 3 6.8 0.68" 4 | ABB 43.5 1.71" Dimensions: mm, inches 1SBC103001S0201 85 3.35" 35 mm EN/IEC 60175 45 1.77" Pos. 1, 3, 4, 1 30 1.1 0.43" Pos. 1 24 A AC-1/AC-7a ESB24 Installation Contactors AC / DC Operated Application Certifications and Approvals The ESB contactors are used mainly in buildings for switching and controlling lighting, heating, ventilation and pumps. They are part of the complete range of Din rail products and can be integrated easily in dedicated panels. UL CSA CCC RMRS BV GL LRS CE DNV Description The ESB24 contactors are used for the control of single and three-phases loads up to 24 A. Due to their DC solenoid actuator, the ESB24 can be connected to AC or DC voltages. This provides the following benefits: Hum-free operating system, no vibration, silent in operation, low power consumption, integrated high overvoltage protection 5 kV. You can choose between a various N.O. and N.C. contacts combination. Main accessories: Auxiliary contact blocks EH04. Ordering Details Main poles A1 1 3 5 7 A2 2 4 6 8 Nb of Control coil voltage modules 40... 450 Hz DC 2 12 V 12 V 24 V 24 V 42 V 42 V 48 V 48 V 110...120 V 110...120 V 230...240 V 230...240 V 400...415 V 400...415 V 2 12 V 12 V 24 V 24 V 42 V 42 V 48 V 48 V 110...120 V 110...120 V 230...240V 230...240V 400...415 V 400...415 V 2 12 V 12 V 24 V 24 V 42 V 42 V 48 V 48 V 110...120 V 110...120 V 230...240 V 230...240 V 400...415 V 400...415 V 2 12 V 12 V 24 V 24 V 42 V 42 V 48 V 48 V 110...120 V 110...120 V 230...240 V 230...240 V 400 ...415 V 400 ...415 V 2 12 V 12 V 24 V 24 V 42 V 42 V 48 V 48 V 110...120 V 110...120 V 230...240 V 230...240 V 400 ... 415 V 400 ... 415 V 4 N.O. A1 R1 R3 R5 R7 A2 R2 R4 R6 R8 4 N.C. A1 1 R3 R5 7 A2 2 R4 R6 8 2 N.O. 2 N.C. A1 1 R3 5 7 A2 2 R4 6 8 3 N.O. 1 N.C. A1 R1 3 R5 R7 A2 R2 4 R6 R8 1 N.O. 3 N.C. Type Order code ESB24-40 GHE3291102R1004 GHE3291102R0001 GHE3291102R0002 GHE3291102R0003 GHE3291102R0004 GHE3291102R0006 GHE3291102R0007 GHE3291202R1004 GHE3291202R0001 GHE3291202R0002 GHE3291202R0003 GHE3291202R0004 GHE3291202R0006 GHE3291202R0007 GHE3291302R1004 GHE3291302R0001 GHE3291302R0002 GHE3291302R0003 GHE3291302R0004 GHE3291302R0006 GHE3291302R0007 GHE3291602R1004 GHE3291602R0001 GHE3291602R0002 GHE3291602R0003 GHE3291602R0004 GHE3291602R0006 GHE3291602R0007 GHE3291702R1004 GHE3291702R0001 GHE3291702R0002 GHE3291702R0003 GHE3291702R0004 GHE3291702R0006 GHE3291702R0007 ESB24-04 ESB24-22 ESB24-31 ESB24-13 Main Technical Data Main poles acc to. IEC 60947-4-1 and IEC 61095 Magnet system Connecting capacity Mounting positions Pos. 2 +30 Pack(ing) pieces 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Weight kg (1 pce) 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28 0.28 For complete technical data see 1SBC103005S0201.pdf Rated operational voltage Ue Ie AC-1 / AC-7a Rated operational current (for air temperature close to contactor 55C) AC-3 / AC-7b Ratings (for air temperature close to contactor 55C) Rated operational power 3 phases 400 V 3 phases Ie Rated operational current 400 V Coil operating limits (acc. to IEC 60947-4-1) Average pull-in coil consumption value Average holding coil consumption value Main pole terminals Rigid Coil terminals Rigid 400 V 24 A 4 kW 9A 0.85 ... 1.1 Uc (at 55C) 4 VA / 4 W 4 VA / 4 W 1 x 1.5 ... 10 mm2 2 x 1.5 ... 4 mm2 1 x 1 ... 4 mm2 2 x 0.75 ... 2.5 mm2 -30 59 2.32" 36 1.42" Pos. 4 Pos. 3 Pos. 5 6.8 0.68" 43.5 1.71" Dimensions: mm, inches ABB | 5 1SBC103002S0201 1.1 0.43" Pos. 1, 3, 4, 1 30 90 3.54" 45 1.77" 35 mm EN/IEC 60175 Pos. 1 40 A AC-1/AC-7a ESB40 Installation Contactors AC / DC Operated Application Certifications and Approvals The ESB contactors are used mainly in buildings for switching and controlling lighting, heating, ventilation and pumps. They are part of the complete range of Din rail products and can be integrated easily in dedicated panels. UL CSA RMRS CCC BV GL LRS CE DNV Description The ESB40 contactors are used for the control of single and three-phases loads up to 40 A. Due to their DC solenoid actuator, the ESB40 can be connected to AC or DC voltages. This provides the following benefits: Hum-free operating system, no vibration, silent in operation, low power consumption, integrated high overvoltage protection 5 kV. You can choose between a various N.O. and N.C. contacts combination. Main accessories: Auxiliary contact blocks EH04. Ordering Details Main poles A1 1 3 5 7 A2 2 4 6 8 4 N.O. A1 1 R3 R5 7 A2 2 R4 R6 8 GHE3491102R1004 GHE3491102R0001 GHE3491102R0002 GHE3491102R0003 GHE3491102R0004 GHE3491102R0006 GHE3491102R0007 GHE3491102R0008 GHE3491302R0001 GHE3491302R0006 Pack(ing) pieces 3 3 3 3 3 3 3 3 3 3 Weight kg (1 pce) 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 0.40 ESB40-31 GHE3491602R0001 GHE3491602R0006 3 3 0.40 0.40 24 V 230 V 400 V ESB40-30 GHE3491502R0001 GHE3491502R0006 GHE3491502R0007 3 3 3 0.39 0.39 0.39 24 V 230 V ESB40-20 GHE3491402R0001 GHE3491402R0006 3 3 0.38 0.38 Nb of Control coil voltage modules 40... 450 Hz DC 3 12 V 12 V 24 V 24 V 42 V 42 V 48 V 48 V 110...120 V 110...120 V 230...240 V 230...240 V 400...415 V 400...415 V 415 V 415 V 3 24 V 24 V 230 V 230 V Type Order code ESB40-40 3 24 V 230 V 24 V 230 V 3 24 V 230 V 400 V 3 24 V 230 V ESB40-22 2 N.O. 2 N.C. A1 1 R3 5 7 A2 2 R4 6 8 3 N.O. 1 N.C. A1 1 3 5 A2 2 4 6 3 N.O. A1 1 3 A2 2 4 2 N.O. Main Technical Data Main poles acc to. IEC 60947-4-1 and IEC 61095 For complete technical data see 1SBC103005S0201.pdf Rated operational voltage Ue 400 V Ie AC-1 / AC-7a Rated operational current (for air temperature close to contactor 55C) 40 A AC-3 / AC-7b Ratings (for 1500 r.p.m., 50 Hz or 1800 r.p.m., 60 Hz, 3-phase motors) (for air temperature close to contactor 55C) Rated operational power 3 phases Ie Max. Rated operational current 3 phases Coil operating limits (acc. to IEC 60947-4-1) Average pull-in coil consumption value Average holding coil consumption value Main pole terminals Rigid Magnet system Connecting capacity Mounting positions Pos. 2 +30 Coil terminals Rigid -30 59 2.32" 400 V 400 V 11 kW 22 A 0.85 ... 1.1 Uc (at 55C) 5 VA / 5 W 5 VA / 5 W 1 x 1.5 ... 25 mm2 2 x 1.5 ... 10 mm2 1 x 1 ... 4 mm2 2 x 0.75 ... 2.5 mm2 54 2.13" Pos. 4 Pos. 3 Pos. 5 6 | ABB 6.8 0.68" 43.5 1.71" Dimensions: mm, inches 1SBC103003S0201 90 3.54" 35 mm EN/IEC 60175 45 1.77" Pos. 1, 3, 4, 1 30 1.1 0.43" Pos. 1 63 A AC-1/AC-7a ESB63 Installation Contactors AC / DC Operated Application Certifications and Approvals The ESB contactors are used mainly in buildings for switching and controlling lighting, heating, ventilation and pumps. They are part of the complete range of Din rail products and can be integrated easily in dedicated panels. UL CSA RMRS CCC BV GL LRS CE DNV Description The ESB63 contactors are used for the control of single and three-phases loads up to 63 A. Due to their DC solenoid actuator, the ESB63 can be connected to AC or DC voltages. This provides the following benefits: Hum-free operating system, no vibration, silent in operation, low power consumption, integrated high overvoltage protection 5 kV. You can choose between a various N.O. and N.C. contacts combination. Main accessories: Auxiliary contact blocks EH04. Ordering Details Main poles A1 1 3 5 7 A2 2 4 6 8 4 N.O. A1 1 R3 R5 7 A2 2 R4 R6 8 2 N.O. GHE3691102R1004 GHE3691102R0001 GHE3691102R0002 GHE3691102R0003 GHE3691102R0004 GHE3691102R0006 GHE3691102R0007 GHE3691102R0008 GHE3691302R0007 Pack(ing) pieces 3 3 3 3 3 3 3 3 3 Weight kg (1 pce) 0.42 0.42 0.42 0.42 0.42 0.42 0.42 0.42 0.42 ESB63-31 GHE3691602R0004 GHE3691602R0006 3 3 0.42 0.42 230 V 400 V ESB63-30 GHE3691502R0006 GHE3691502R0007 3 3 0.41 0.41 24 V 230 V 24 V 230 V ESB63-20 GHE3691402R0001 GHE3691402R0006 3 3 0.40 0.40 230 V 230 V ESB63-11 GHE3691802R0006 3 0.40 Nb of Control coil voltage modules 40... 450 Hz DC 3 12 V 12 V 24 V 24 V 42 V 42 V 48 V 48 V 110...120 V 110...120 V 230...240 V 230...240 V 400...415 V 400...415 V 415 V 415 V 3 400 V 400 V Type Order code ESB63-40 3 110 V 230 V 110 V 230 V 3 230 V 400 V 3 3 ESB63-22 2 N.C. A1 1 R3 A2 2 R4 3 N.O. 5 7 6 8 1 N.C. A1 1 3 5 A2 2 4 6 3 N.O. A1 1 3 A2 2 4 2 N.O. A1 1 R3 A2 2 R4 1 N.O. 1 N.C. Main Technical Data Main poles acc to. IEC 60947-4-1 and IEC 61095 For complete technical data see 1SBC103005S0201.pdf Rated operational voltage Ue 400 V Ie AC-1 / AC-7a Rated operational current (for air temperature close to contactor 55C) 63 A AC-3 / AC-7b Ratings (for 1500 r.p.m., 50 Hz or 1800 r.p.m., 60 Hz, 3-phase motors) (for air temperature close to contactor 55C) Rated operational power 3 phases Ie Max. rated operational current 3 phases Coil operating limits (acc. to IEC 60947-4-1) Average pull-in coil consumption value Average holding coil consumption value Main pole terminals Rigid Magnet system Connecting capacity Mounting positions Pos. 2 +30 Coil terminals Rigid -30 59 2.32" 400 V 400 V 15 kW 30 A 0.85 ... 1.1 Uc (at 55C) 65 VA / 65 W 4.2 VA / 4.2 W 1 x 1.5 ... 25 mm2 2 x 1.5 ... 10 mm2 1 x 1 ... 4 mm2 2 x 0.75 ... 2.5 mm2 54 2.13" Pos. 4 Pos. 3 Pos. 5 6.8 0.68" 43.5 1.71" Dimensions: mm, inches ABB | 7 1SBC103004S0201 90 3.54" 35 mm EN/IEC 60175 45 1.77" Pos. 1, 3, 4, 1 30 1.1 0.43" Pos. 1 ESB Installation Contactors Technical Data Main Pole - Utilization Characteristics according to IEC Contactor types: AC operated AC / DC operated Rated operational voltage Ue max. Rated frequency limits Utilization category AC-1 / AC-7a V Hz ESB20 ESB24 ESB40 ESB63 AC: 250, DC: 220 50/60, DC AC: 400, DC: 220 20 20 24 24 40 30 63 30 9 - 9 9 22 22 30 30 1.1 10 x Ie / AC-3 8 x Ie / AC-3 1.3 4 3.7 11 5 15 20 35 63 80 72 1 3 176 4 240 6 150000 500000 150000 170000 150000 240000 for air temperature close to contactor < 55 C 300 600 150000 150000 1 U U U U Max. rated operational current Ie AC-1 / AC-7a N.O. A N.C. A Utilization category AC-3 / AC-7b for air temperature close to contactor < 55 C Max. rated operational current Ie AC-3/AC-7b A 230 V - 1 phase N.O. A 400 V - 3 phases N.O. Rated operational power AC-3 230 V - 1 phase kW 400 V - 3 phases kW Rated making capacity AC-3 Rated breaking capacity AC-3 Short-circuit protection for contactors gG type fuse A Rated short-time withstand current Icw at 40 C ambient temp., in free air, from a cold state 10 s A W Heat dissipation per pole Ie / AC-1/AC-7a Max. electrical switching frequency - for AC-1 / AC-7a cycles/h - for AC-3 / AC-7b cycles/h Electrical durability - for AC-1 / AC-7a cycles - for AC-3 / AC-7b cycles Mechanical durability - millions of operating cycles Single-phase (AC-1, AC-7a) Three-phase (AC-1, AC-7a) L1 L1 U L2 U V M M Single-phase (AC-7b) 8 | ABB V L3 Three-phase (AC-7b, AC-3) W 1SBC103005S0201 L2 ESB Installation Contactors Technical Data Main Pole - Utilization Characteristics according to UL/CSA Contactor types: AC operated AC / DC operated General use rating Amp rating ESB20 ESB24 ESB40 ESB63 240 V 480 V A A 20 - 24 40 63 120 V - 1 phase 240 V - 1 phase N.O. N.C. 440 - 480 V - 3 phases N.O. N.C. A A A A A 9.8 9.8 8 - 9.6 9.6 7.6 3.4 22 22 21 - 28 30 21 - 120 V - 1 phase 240 V - 1 phase 440 - 480 V - 3 phases hp hp hp 1/2 1 - 3 5 7.5 15 10 15 25 - 25 / K5 - 40 / K5 - 75 / K5 - Motor rating Amp rating Motor power Short-circuit protection for contactors without thermal O/L relay - Motor protection excluded Fuse rating, 480 V Fuse type, 600 V Max. electrical switching frequency - for general use - for motor use A cycles/h cycles/h 300 600 General Technical Data Rated insulation voltage Ui according to IEC 60947-4-1 according to UL/CSA Rated impulse withstand voltage Uimp Standards Air temperature close to contactor - for operation at 0.85 ... 1.1 Uc - for storage Climatic withstand Operating altitude Shock withstand Mounting positions Pos 1, 3, 4, 130 Pos 5 : not allowed for ESB20 V V kV 400 500 240 600 6 IEC 60947-4-1 / EN 60947-4-1 and IEC 61095 / EN 61095, UL 508, CSA C22.2 N14-05 C C -25 ... +55 (Type ESB24...63: for ambient temperature > 40C, add ESB-DIS (1/2 module) at every second contactor) -40 ... +80 IEC 60068-2-30, UTE 63-100 execution 1* 2000 10 g / 4 ms / axes X Y Z m Pos. 2 +30 -30 Pos. 4 Pos. 3 Pos. 1 Fixing on rail acc. to IEC 60715 and EN 60715 35 x 7.5 Pos. 1/3/4/1 30 Pos. 5 35 x 15 1SBC103005S0201 * ESB20 only ABB | 9 ESB Installation Contactors Technical Data Magnet System Characteristics Contactor types: AC operated AC / DC operated Rated operational voltage Ue max. - at 50 Hz V - at 60 Hz V - at 400 Hz V DC V Coil operating limits acc. to IEC 60947-4-1 Drop-out voltage in % of Uc Frequency range Hz Coil consumption VA / W Average pull-in value Average holding value VA / W Operating time between coil energization and: - N.O. contact closing ms between coil de-energization and: - N.O. contact opening ms ESB20 ESB24 ESB40 ESB63 12 ... 400 12 ... 415 14 ... 380 12 ... 415 12 ... 415 12 ... 415 0.85 ... 1.1 x Uc (at 55 C) approx. 20 ... 75 % approx. 10 ... 75 % 50/60 DC, 50 ... 400 24 ... 415 24 ... 415 24 ... 415 24 ... 415 8/5 3.2 / 1.2 4/4 4/4 5/5 5/5 65 / 65 4.2 / 4.2 12 40 12 40 ESB24 ESB40 ESB63 16-8 1.5 ... 25 1.5 ... 10 16-4 Connecting Characteristics Contactor types: AC operated AC / DC operated Connecting capacity (min. ... max.) Main pole terminals Rigid Capacity acc. to UL/CSA Coil terminals Rigid Capacity acc. to UL/CSA Degree of protection ESB20 1 x mm 2 x mm AWG 1.5 ... 10 1.5 ... 4 14-8 1 x mm 2 x mm AWG 0.5 ... 4 0.75 ... 2.5 18-14 1 ... 4 16-10 acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529 Protection against direct contact in acc. with EN 50274 IP20 Flat O 5 / Pozidriv 1 Flat O 5 / Pozidriv 1 Flat O 7.5 / Pozidriv 2 Flat O 5 / Pozidriv 1 mm mm 10 7 13 Nm Nm 1.2 0.9 1 2.5 1SBC103005S0201 All terminals Screwdriver type Main poles Coil terminals Stripping length Main poles Coil terminals Tightening torque Main poles Coil terminals 10 | ABB ESB Installation Contactors Technical Data EH04... Auxiliary Contact Block - Utilization Characteristics according to IEC Contactor types: AC operated AC / DC operated Rated operational voltage Ue max. Conventional free air thermal current Ith < 40 C Rated frequency limits Rated operational current Ie / AC-15 acc. to IEC 60947-5-1 240 V 50/60 Hz 415 V 50/60 Hz 500 V 50/60 Hz acc. to IEC 60947-5-1 Making capacity Breaking capacity acc. to IEC 60947-5-1 Short-circuit protection gI type fuse Minimum switching capacity with failure rate acc. to IEC 60947-5-4 Heat dissipation per pole at 6 A ESB20 ESB24 ESB40 V - 500 A Hz - 6 50/60 A A A A - 4 3 2 11 x Ie AC-15 11 x Ie AC-15 10 V/mA W - 17 / 5 0.1 ESB63 Electrical durability AC-1 / 400 V / 3-phase for ESB20...63 1,5 2 ESB63 ESB24 1 ESB40 ESB20 Millions of operating cycles 2 1 0.8 0.6 0.5 0.4 0.3 0.2 0.1 0.08 0.06 0.05 0.04 0.03 0.02 0.01 AC-3 / 400 V / 3-phase for ESB24...63 Breaking current [A] 3 4 5 6 8 10 16 20 24 30 40 50 63 80 ESB63 ESB40 ESB24 Millions of operating cycles 2 1 0.8 0.6 0.5 0.4 0.3 0.2 0.1 0.08 0.06 0.05 0.04 0.03 0.02 Breaking current [A] Switching capacity [kW] 0.01 1.5 2 3 1.1 4 5 6 8 10 2.2 3 4 16 7.5 11 24 30 40 50 63 80 1SBC103005S0201 1 15 ABB | 11 ESB Installation Contactors Technical Data DC-1/DC-3 switching DC with N.O. contacts (N.O.) Type Rated operating voltage Ue DC-1 (L/R 1 ms) 1 current path 2 current paths 3 current paths in series in series DC-3 (L/R 2 ms) 1 current path 2 current paths 3 current paths in series in series ESB20-20 24 V DC 48 V DC 60 V DC 110 V DC 220 V DC 24 V DC 48 V DC 60 V DC 110 V DC 220 V DC 24 V DC 48 V DC 60 V DC 110 V DC 220 V DC 24 V DC 48 V DC 60 V DC 110 V DC 220 V DC 20 A 15 A 15 A 5A 0.5 A 24.0 A 21.0 A 17.0 A 7.0 A 0.9 A 40.0 A 23.0 A 18.0 A 8.0 A 1.0 A 50.0 A 25.0 A 20.0 A 9.0 A 1.1 A 15 A 7A 5A 1.5 A 0.2 A 16.0 A 8.0 A 4.0 A 1.6 A 0.2 A 19.0 A 10.0 A 5.0 A 1.8 A 0.3 A 21.0 A 11.0 A 5.5 A 2.0 A 0.3 A ESB24 ESB40 ESB63 20 A 20 A 20 A 15 A 5A 24.0 A 24.0 A 24.0 A 16.0 A 4.5 A 40.0 A 40.0 A 32.0 A 17.0 A 5.0 A 63.0 A 43.0 A 35.0 A 19.0 A 5.5 A 24.0 A 24.0 A 24.0 A 24.0 A 13.0 A 40.0 A 40.0 A 40.0 A 30.0 A 15.0 A 63.0 A 63.0 A 60.0 A 33.0 A 17.0 A 20 A 15 A 10 A 5A 1.5 A 24.0 A 18.0 A 14.0 A 6.5 A 1.0 A 40.0 A 20.0 A 16.0 A 7.0 A 1.1 A 44.0 A 22.0 A 18.0 A 8.0 A 1.2 A 24.0 A 24.0 A 24.0 A 16.0 A 4.0 A 40.0 A 40.0 A 34.0 A 18.0 A 4.5 A 63.0 A 47.0 A 38.0 A 21.0 A 5.0 A DC-1/DC-3 switching DC with N.C. contacts (N.C.) Type Rated operating voltage Ue DC-1 (L/R 1 ms) 1 current path 2 current paths 3 current paths in series in series DC-3 (L/R 2 ms) 1 current path 2 current paths 3 current paths in series in series ESB20-02 24 V DC 48 V DC 60 V DC 110 V DC 220 V DC 24 V DC 48 V DC 60 V DC 110 V DC 220 V DC 14 A 7A 4.5 A 1.5 A 0.2 A 14.5 A 7.5 A 4.5 A 1.6 A 0.2 A 6A 3A 2A 0.6 A 0.1 A 6.3 A 3.1 A 2.0 A 0.7 A 0.1 A 24.0 A 22.0 A 17.5 A 9.5 A 3.8 A 10 A 6A 4A 1.8 A 0.6 A 11.0 A 5.4 A 4.3 A 1.9 A 0.6 A 19.0 A 9.4 A 7.5 A 4.1 A 1.6 A 1SBC103005S0201 ESB24 20 A 14 A 10 A 4.4 A 1.5 A 24.0 A 12.5 A 10.0 A 4.4 A 1.4 A 12 | ABB ESB Installation Contactors - Lighting Application Technical Data Switching of lamp load The following table shows the number of lamps which can be connected per phase at 230 V, 50 Hz. Air temperature, near the contactor, must be limited to 55C. Please, note that the given capacitor load must not be exceeded, otherwise inadmissible high inrush current peaks could occur. These are influenced by the length and cross section of the wire used, the type of power supply unit and specifications of the lamp brand. For these reasons, values in the table are for information only. Numbers are given for a 230V voltage distributed between phase and neutral: single phase (phase + neutral) or three-phases (3 phases + neutral), lamps are wired in star connection. In the case of three-phase supply without neutral, 230V phase-to-phase, the permissible number of lamps per phase will be that given in the table multiplied by 0.58. Lamp type Incandescent lamps Fluorescent lamps Uncompensated and series compensation Two-lamp circuit Parallel compensation High pressure mercury-vapor lamps Uncompensated Parallel compensation Lamps with electronic power supply units Lamp data Permissible number of lamps per phase (230 V, 50 Hz ) Watt 60 100 200 300 500 1000 15 20 40 42 58 65 115 140 2 x 20 2 x 40 2 x 42 2 x 58 2 x 65 2 x 115 2 x 140 15 20 40 42 58 65 115 140 50 80 125 250 400 700 1000 2000/ 400 V 50 80 125 250 400 700 1000 2000/ 400 V 1 x 18 2 x 18 1 x 36 2 x 36 1 x 58 2 x 58 Capacitor In A 0.26 0.43 0.87 1.30 2.17 4.35 0.33 0.37 0.43 0.54 0.64 0.67 1.3 1.5 2 x 0.13 2 x 0.22 2 x 0.24 2 x 0.34 2 x 0.34 2 x 0.65 2 x 0.75 0.11 0.13 0.22 0.24 0.34 0.34 0.65 0.75 0.61 0.8 1.15 2.15 3.25 5.40 7.5 8 ESB20 ESB24 ESB40 ESB63 F 21 13 7 4 3 1 40 37 32 26 21 21 9 9 2 x 22 2 x 17 2 x 13 2 x 10 2 x 10 2x4 2x4 16 16 16 13 11 11 4 4 30 15 10 6 2 2 1 - 25 15 7 5 3 1 30 26 20 16 12 12 5 5 2 x 26 2 x 20 2 x 16 2 x 12 2 x 12 2x5 2x5 8 8 8 6 5 5 2 2 14 10 7 4 2 1 1 1 54 32 16 11 6 3 100 85 65 52 40 40 18 18 2 x 85 2 x 65 2 x 52 2 x 40 2 x 40 2 x 18 2 x 18 16 16 16 12 10 10 4 4 36 27 19 10 7 4 3 3 83 50 25 16 10 5 155 135 105 85 65 65 28 28 2 x 140 2 x 105 2 x 65 2 x 65 2 x 65 2 x 28 2 x 28 67 67 67 50 43 43 17 17 50 38 26 14 10 6 4 4 0.28 0.41 0.65 1.22 1.95 3.45 4.8 5.45 4 3 2 1 - - - - 5 4 3 2 1 - - 1 10 8 6 3 3 1 1 2 43 37 26 15 10 5 4 3 - - - - - - 15 8 12 7 11 6 24 18 16 11 14 8 55 34 34 20 32 17 76 48 47 29 46 24 4.5 4.5 4.5 6 7 7 18 18 7 8 10 18 25 45 60 35 Lamp type Lamp data Permissible number of lamps per phase (230 V, 50 Hz ) Watt ESB20 ESB24 ESB40 ESB63 9 4 3 1 1 - - - - 10 5 3 2 1 - - - - 28 14 8 5 4 1 1 2 1 38 20 11 7 6 2 1 2 1 - - - - - - - - - 5 3 1 1 - - - - - 11 5 3 2 2 - - 1 - 30 18 9 7 6 2 1 2 1 In A 0.53 1 1.8 3 3.5 9.5 16.5 10.5 18 35 Halogen metal-vapor lamps 70 150 Uncompensated 250 400 1000 2000 2000/ 3500/ 400 V 35 0.25 Parallel 70 0.45 compensation 150 0.75 250 1.5 400 2.5 1000 5.8 2000 11.5 2000/ 6.6 3500/ 11.6 400 V 35 1.5 Low pressure 55 1.5 sodium-vapor 90 2.4 lamps 135 3.5 Uncompensated 150 3.3 180 3.3 200 2.3 35 0.31 Parallel 55 0.42 compensation 90 0.63 135 0.94 150 1.0 180 1.16 200 1.32 150 1.8 High pressure 250 3.0 sodium-vapor 330 3.7 lamps 400 4.7 Uncompensated 1000 10.3 150 0.83 Parallel 250 1.5 compensation 330 2.0 400 2.4 1000 6.3 Transformers Transformers for halogen for Watt low voltage lamps 20 (12 or 24 V AC) 50 75 100 150 200 300 Capacitor F 6 12 20 33 35 95 148 58 100 10 8 22 30 10 8 22 30 5 5 13 19 3 3 10 13 3 3 10 14 3 3 10 14 3 5 14 20 1 4 15 20 1 4 15 20 1 3 10 30 2 7 45 2 8 40 2 8 40 1 3 12 25 3 4 15 20 2 3 9 15 1 2 8 10 1 6 8 3 4 1 3 15 20 1 2 9 33 2 7 40 1 6 48 2 106 Permissible number of transformers per circuit (230 V, 50 Hz) 40 50 110 174 20 24 50 80 13 16 35 54 10 12 27 43 7 9 19 29 5 6 14 23 3 4 9 14 L1 L1 230 V N L3 N Single-phase Three-phase Three-phase with neutral 400 V 1SBC103007S0201 230 V 230 V 230 V L3 230 V L2 L1 230 V 230 V L2 ABB | 13 20 A AC-1/AC-7a EN20 Installation Contactors - Manually / Automatic Operated AC Operated Application Certifications and Approvals The EN contactors are used mainly in buildings for switching and controlling lighting, heating, ventilation and pumps. They are part of the complete range of Din rail products and can be integrated easily in dedicated panels. UL CSA CE CCC Description The EN20 contactors are used for the control of single phase loads up to 20 A. They operate with an AC coil. EN contactors have a built-in toggle switch to select between three function modes: Off position, automatic run (normal contactor function), manual override with a return to Auto the next time the coil is energized. This offers many advantages as: You can make functional test before installation start-up. It can be used for maintenance operation, to change lamps and test it. It provides higher safety and drop out as you can switch the application manually. The toggle switch is also used for household application like water heating where double tariff of kWh is used. Ordering Details 1 Main poles 3 0 = Off A1 0 1 3 A2 2 4 Type Order code Pack(ing) Weight pieces kg (1 pce) 1 EN20-20 GHE3221101R0001 GHE3221101R0006 10 10 24 V 230 V 28 V 264 V 0.14 0.14 2 N.O. S T 0 P A U T O A1 Nb of Control coil voltage modules 50 Hz 60 Hz Automatic run M A N 1 2 I = ON 2 4 Main Technical Data Main poles acc to. IEC 60947-4-1 and IEC 61095 Magnet system Connecting capacity Coil terminals Mounting positions Pos. 2 +30 For complete technical data see 1SBC103005S0201.pdf Rated operational voltage Ue Ie AC-1 / AC-7a Rated operational current (for air temperature close to contactor 55C) 230 V Pe AC-1 Rated operational power Coil operating limits (acc. to IEC 60947-4-1) Average pull-in coil consumption value Average holding coil consumption value Main pole terminals Rigid Rigid -30 58 2.28" 250 V 20 A 4 kW 0.85 ... 1.1 Uc (at 55C) 8 VA / 5 W 3.2 VA / 1.2 W 1 x 1.5 ... 10 mm2 2 x 1.5 ... 4 mm2 1 x 0.5 ... 4 mm2 2 x 0.75 ... 2.5 mm2 17.5 0.69" Pos. 4 Pos. 3 6.8 0.68" 14 | ABB 43.5 1.71" Dimensions: mm, inches 1SBC103008S0201 85 3.35" 35 mm EN/IEC 60175 45 1.77" Pos. 1, 3, 4, 1 30 1.1 0.43" Pos. 1 24 A AC-1/AC-7a EN24 Installation Contactors - Manually / Automatic Operated AC / DC Operated Application Certifications and Approvals The EN contactors are used mainly in buildings for switching and controlling lighting, heating, ventilation and pumps. They are part of the complete range of Din rail products and can be integrated easily in dedicated panels. UL CSA CE CCC Description The EN24 contactors are used for the control of single and three-phase loads up to 24 A. They operate with a DC coil. EN contactors have a built-in toggle switch to select between three function modes: Off position, automatic run (normal contactor function), manual Override with a return to Auto the next time the coil is energized. This offers many advantages as: You can make functional test before installation start-up, it can be used for maintenance operation, to change lamps and test it, it provide higher safety and drop out as you can switch the application manually. The toggle switch is also used for household application like water heating where double tariff of kWh is used. Ordering Details 1 Main poles 3 0 = Off A1 0 5 7 A2 2 4 6 8 Pack(ing) Weight pieces kg (1 pce) 2 24 V 230/240 V 24 V 230/240 V EN24-40 GHE3261101R0001 GHE3261101R0006 5 5 0.24 0.24 A1 1 R3 5 7 2 24 V 230/240 V 24 V 230/240 V EN24-31 GHE3261601R0001 GHE3261601R0006 5 5 0.24 0.24 A2 2 R4 6 8 2 230/240 V 230/240 V EN24-30 GHE3261501R0006 5 0.23 3 N.O. 1 N.C. 2 I = ON 2 3 Order code Automatic run M A N 1 1 Type 4 N.O. S T 0 P A U T O A1 Nb of Control coil voltage modules 40...450 Hz DC A1 1 3 5 A2 2 4 6 3 N.O. 4 Main Technical Data Main poles acc to. IEC 60947-4-1 and IEC 61095 Magnet system Connecting capacity Mounting positions Pos. 2 +30 For complete technical data see 1SBC103005S0201.pdf Rated operational voltage Ue 400 V Ie AC-1 / AC-7a Rated operational current (for air temperature close to contactor 55C) 24 A 230 V Pe AC-1 Rated operational power 5.3 kW 400 V 16 kW Coil operating limits (acc. to IEC 60947-4-1) 0.85 ... 1.1 Uc (at 55C) Average pull-in coil consumption value 4 VA / 4 W Average holding coil consumption value 4 VA / 4 W Main pole terminals Rigid 1 x 1.5 ... 10 mm2 2 x 1.5 ... 4 mm2 Coil terminals Rigid 1 x 1 ... 4 mm2 2 x 0.75 ... 2.5 mm2 -30 36 1.42" 58 2.28" Pos. 4 Pos. 3 Pos. 5 6.8 0.68" 43.5 1.71" Dimensions: mm, inches ABB | 15 1SBC103009S0201 85 3.35" 35 mm EN/IEC 60175 45 1.77" Pos. 1, 3, 4, 1 30 1.1 0.43" Pos. 1 40 A AC-1/AC-7a EN40 Installation Contactors - Manually / Automatic Operated AC / DC Operated Application Certifications and Approvals The EN contactors are used mainly in buildings for switching and controlling lighting, heating, ventilation and pumps. They are part of the complete range of Din rail products and can be integrated easily in dedicated panels. UL CSA CE CCC Description The EN40 contactors are used for the control of single and three-phase loads up to 40 A. They operate with a DC coil. EN contactors have a built-in toggle switch to select between three function modes: Off position, automatic run (normal contactor function), manual Override with a return to Auto the next time the coil is energized. This offers many advantages as: You can make functional test before installation start-up, it can be used for maintenance operation, to change lamps and test it, it provide higher safety and drop out as you can switch the application manually. The toggle switch is also used for household application like water heating where double tariff of kWh is used. Ordering Details 1 Main poles 3 0 = Off A1 0 5 7 A2 2 4 6 8 Pack(ing) Weight pieces kg (1 pce) 3 24 V 110 V 230/240 V 24 V 110 V 230/240 V EN40-40 GHE3421101R0001 GHE3421101R0004 GHE3421101R0006 3 3 3 0.41 0.41 0.41 A1 1 R3 5 7 3 24 V 230/240 V 24 V 230/240 V EN40-31 GHE3421601R0001 GHE3421601R0006 3 3 0.41 0.41 A2 2 R4 6 8 3 230/240 V 230/240 V EN40-30 GHE3421501R0006 3 0.40 3 230/240 V 230/240 V EN40-20 GHE3421401R0006 3 0.30 3 N.O. 1 N.C. 2 I = ON 2 3 Order code Automatic run M A N 1 1 Type 4 N.O. S T 0 P A U T O A1 Nb of Control coil voltage modules 40...450 Hz DC A1 1 3 5 A2 2 4 6 3 N.O. 4 A1 1 3 A2 2 4 2 N.O. Main Technical Data Main poles acc to. IEC 60947-4-1 and IEC 61095 Magnet system Connecting capacity Mounting positions Pos. 2 +30 -30 For complete technical data see 1SBC103005S0201.pdf Rated operational voltage Ue 400 V Ie AC-1 / AC-7a Rated operational current (for air temperature close to contactor 55C) 40 A 230 V Pe AC-1 Rated operational power 8.8 kW 400 V 26 kW Coil operating limits (acc. to IEC 60947-4-1) 0.85 ... 1.1 Uc (at 55C) Average pull-in coil consumption value 5 VA / 5 W Average holding coil consumption value 5 VA / 5 W Main pole terminals Rigid 1 x 1.5 ... 25 mm2 2 x 1.5 ... 10 mm2 Coil terminals Rigid 1 x 1 ... 4 mm2 2 x 0.75 ... 2.5 mm2 54 2.13" 58 2.28" Pos. 4 Pos. 3 Pos. 5 6.8 0.68" 16 | ABB 43.5 1.71" Dimensions: mm, inches 1SBC103012S0201 85 3.35" 35 mm EN/IEC 60175 45 1.77" Pos. 1, 3, 4, 1 30 1.1 0.43" Pos. 1 EN Installation Contactors - Manually / Automatic Operated Technical Data Main Pole - Utilization Characteristics according to IEC Contactor types: AC operated AC / DC operated Rated operational voltage Ue max. Rated frequency limits Utilization category AC-1 / AC-7a V Hz EN20 EN24 EN40 250 50/60 400 A A 20 - 24 24 40 30 A 20 35 63 10 s A Heat dissipation per pole Ie / AC-1 / AC-7a W Max. electrical switching frequency - for AC-1 / AC-7a cycles/h Electrical Durability - for AC-1 / AC-7a cycles Mechanical durability - millions of operating cycles 72 1 for air temperature close to contactor < 55 C Max. rated operational current Ie AC-1 / AC-7a N.O. N.C. Short-circuit protection for contactors gG type fuse Rated short-time withstand current Icw at 40 C ambient temp., in free air, from a cold state 176 4 300 150000 1 General Technical Data Contactor types: AC operated AC / DC operated Rated insulation voltage Ui according to IEC 60947-4-1 Rated impulse withstand voltage Uimp. Standards Air temperature close to contactor - for operation at 0.85 ... 1.1 Uc - for storage Climatic withstand Operating altitude Shock withstand Mounting positions Pos 1, 3, 4, 130 Pos 5 : not allowed for EN20 EN20 EN24 EN40 V kV 400 500 6 IEC 60947-4-1 / EN 60947-4-1 and IEC 61095 / EN 61095 C C -25 ... +55 (Type EN24...40: for ambient temperature > 40C, add ESB-DIS (1/2 module) at every second contactor) -40 ... +80 IEC 60068-2-30, UTE 63-100 execution 1* 2000 10 g / 4 ms / axes X Y Z m Pos. 2 +30 -30 Pos. 4 Pos. 3 Pos. 1 Fixing on rail acc. to IEC 60715 and EN 60715 Pos. 1/3/4/1 30 Pos. 5 35 mm 1SBC103014S0201 * EN20 only ABB | 17 EN Installation Contactors - Manually / Automatic Operated Technical Data Magnet System Characteristics Contactor types: AC operated AC / DC operated Rated operational voltage Ue max. - at 50 Hz V - at 60 Hz V V DC Coil operating limits acc. to IEC 60947-4-1 Drop-out voltage in % of Uc Frequency range Hz Coil consumption Average pull-in value VA / W Average holding value VA / W Operating time between coil energization and: - N.O. contact closing ms between coil de-energization and: - N.O. contact opening ms EN20 EN24 EN40 12 ... 415 12 ... 415 12 ... 415 24 ... 415 24 ... 415 24 ... 415 12 ... 400 14 ... 380 0.85 ... 1.1 x Uc (at 55 C) approx. 20 ... 75 % 50/60 approx. 10 ... 75 % 40 ... 450 8/5 3.2 / 1.2 4/4 4/4 12 40 12 40 5/5 5/5 Connecting Characteristics EN20 Contactor types: Connecting capacity (min. ... max.) Main pole terminals Rigid Capacity acc. to UL/CSA Coil terminals Rigid Capacity acc. to UL/CSA Degree of protection 1 x mm 2 x mm AWG 1.5 ... 10 1.5 ... 4 14 ... 8 1 x mm 2 x mm AWG 0.5 ... 4 0.75 ... 2.5 18 ... 14 EN24 EN40 16 ... 8 1.5 ... 25 1.5 ... 10 16 ... 4 1 ... 4 16 ... 10 acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529 Protection against direct contact in acc. with EN 50274 IP20 Flat O 5 / Pozidriv 1 Flat O 5 / Pozidriv 1 Flat O 7.5 / Pozidriv 2 Flat O 5 / Pozidriv 1 mm mm 10 7 13 Nm Nm 1.2 0.9 1 2.5 1SBC103014S0201 All terminals Screwdriver type Main poles Coil terminals Stripping length Main poles Coil terminals Tightening torque Main poles Coil terminals 18 | ABB ESB, EN Installation Contactors Main Accessories Ordering Details Auxiliary Contact Blocks Type Order code Pack(ing) Weight pieces kg (1 pce) EH04-20 EH04-11 GHE3401321R0001 GHE3401321R0002 10 10 Contactor type Type Order code Pack(ing) Weight pieces kg (1 pce) ESB24, EN24 ESB40...63, EN40 ESB-PLK24 GHE3201903R0001 ESB-PLK40/63 GHE3401903R0002 10 10 Contactor type Type Order code Pack(ing) Weight pieces kg (1 pce) ESB24...63, EN24...40 ESB-DIS GHE3201902R0001 10 Contactor type ESB20...63, EN20...40 Type Order code Pack(ing) Weight pieces kg (1 pce) Label - unlabelled* Label - numbering 1-40 Label - numbering 2 * 1-20 Label - numbering 4 * 1-10 Label - numbering 4 * 11-20 Label - labelled L1 Label - labelled L2 Label - labelled L3 SZ-KZS SZ-KZS/1 SZ-KZS/6 SZ-KZS/9 SZ-KZS/10 SZ-KZS/11 SZ-KZS/12 SZ-KZS/13 GHS2101946R0004 GHS2101946R0005 GHS2101946R0010 GHS2101946R0013 GHS2101946R0014 GHS2101946R0015 GHS2101946R0016 GHS2101946R0017 30 30 30 30 30 30 30 30 Contactor type Sealing cover ESB-PLK40/63 Contact blocks ESB24...63 EN24...40 ESB-PLK24 2 1 1 0.004 0.004 Sealing cover 0.002 0.009 Auxiliary Contact Blocks Distance piece 0.002 Labelling material ESB24-40 EH04-20 Contact Blocks EH04-20 EH04-11 Distance piece 0.008 0.008 0.008 0.008 0.008 0.008 0.008 0.008 Note: * The unlabelled can be labelled by water-resistant and permanent marker or by means of computer-controlled labelling system (plotter). Special labels on request: minimum quantities 50 Labelling material ESB-DIS 1SBC103006S0201 SZ-KZS... ABB | 19 Index Order codes Order code Type Order code Type Order code Type GHE3201902R0001 ESB-DIS Page 19 GHE3291302R0004 ESB24-22 Page 5 GHE3691302R0007 ESB63-22 Page 7 GHE3201903R0001 ESB-PLK24 19 GHE3291302R0006 ESB24-22 5 GHE3691402R0001 ESB63-20 7 GHE3211102R0001 ESB20-20 4 GHE3291302R0007 ESB24-22 5 GHE3691402R0006 ESB63-20 7 GHE3211102R0002 ESB20-20 4 GHE3291302R1004 ESB24-22 5 GHE3691502R0006 ESB63-30 7 GHE3211102R0003 ESB20-20 4 GHE3291602R0001 ESB24-31 5 GHE3691502R0007 ESB63-30 7 GHE3211102R0004 ESB20-20 4 GHE3291602R0002 ESB24-31 5 GHE3691602R0004 ESB63-31 7 GHE3211102R0005 ESB20-20 4 GHE3291602R0003 ESB24-31 5 GHE3691602R0006 ESB63-31 7 GHE3211102R0006 ESB20-20 4 GHE3291602R0004 ESB24-31 5 GHE3691802R0006 ESB63-11 GHE3211102R0007 ESB20-20 4 GHE3291602R0006 ESB24-31 5 GHS2101946R0004 SZ-KZS 19 GHE3211102R1004 ESB20-20 4 GHE3291602R0007 ESB24-31 5 GHS2101946R0005 SZ-KZS/1 19 19 7 GHE3211102R1005 ESB20-20 4 GHE3291602R1004 ESB24-31 5 GHS2101946R0010 SZ-KZS/6 GHE3211202R0001 ESB20-02 4 GHE3291702R0001 ESB24-13 5 GHS2101946R0013 SZ-KZS/9 19 GHE3211202R0002 ESB20-02 4 GHE3291702R0002 ESB24-13 5 GHS2101946R0014 SZ-KZS/10 19 GHE3211202R0003 ESB20-02 4 GHE3291702R0003 ESB24-13 5 GHS2101946R0015 SZ-KZS/11 19 GHE3211202R0004 ESB20-02 4 GHE3291702R0004 ESB24-13 5 GHS2101946R0016 SZ-KZS/12 19 GHE3211202R0005 ESB20-02 4 GHE3291702R0006 ESB24-13 5 GHS2101946R0017 SZ-KZS/13 19 GHE3211202R0006 ESB20-02 4 GHE3291702R0007 ESB24-13 5 GHE3211202R0007 ESB20-02 4 GHE3291702R1004 ESB24-13 5 GHE3211202R1004 ESB20-02 4 GHE3401321R0001 EH04-20 19 GHE3211202R1005 ESB20-02 4 GHE3401321R0002 EH04-11 19 GHE3211302R0001 ESB20-11 4 GHE3401903R0002 ESB-PLK40/63 19 GHE3211302R0002 ESB20-11 4 GHE3421101R0001 EN40-40 16 GHE3211302R0003 ESB20-11 4 GHE3421101R0004 EN40-40 16 GHE3211302R0004 ESB20-11 4 GHE3421101R0006 EN40-40 16 GHE3211302R0005 ESB20-11 4 GHE3421401R0006 EN40-20 16 GHE3211302R0006 ESB20-11 4 GHE3421501R0006 EN40-30 16 GHE3211302R0007 ESB20-11 4 GHE3421601R0001 EN40-31 16 GHE3211302R1004 ESB20-11 4 GHE3421601R0006 EN40-31 16 GHE3211302R1005 ESB20-11 4 GHE3491102R0001 ESB40-40 6 GHE3221101R0001 EN20-20 14 GHE3491102R0002 ESB40-40 6 GHE3221101R0006 EN20-20 14 GHE3491102R0003 ESB40-40 6 GHE3261101R0001 EN24-40 15 GHE3491102R0004 ESB40-40 6 GHE3261101R0006 EN24-40 15 GHE3491102R0006 ESB40-40 6 GHE3261501R0006 EN24-30 15 GHE3491102R0007 ESB40-40 6 GHE3261601R0001 EN24-31 15 GHE3491102R0008 ESB40-40 6 GHE3261601R0006 EN24-31 15 GHE3491102R1004 ESB40-40 6 GHE3291102R0001 ESB24-40 5 GHE3491302R0001 ESB40-22 6 GHE3291102R0002 ESB24-40 5 GHE3491302R0006 ESB40-22 6 GHE3291102R0003 ESB24-40 5 GHE3491402R0001 ESB40-20 6 GHE3291102R0004 ESB24-40 5 GHE3491402R0006 ESB40-20 6 GHE3291102R0006 ESB24-40 5 GHE3491502R0001 ESB40-30 6 GHE3291102R0007 ESB24-40 5 GHE3491502R0006 ESB40-30 6 GHE3291102R1004 ESB24-40 5 GHE3491502R0007 ESB40-30 6 GHE3291202R0001 ESB24-04 5 GHE3491602R0001 ESB40-31 6 GHE3291202R0002 ESB24-04 5 GHE3491602R0006 ESB40-31 6 GHE3291202R0003 ESB24-04 5 GHE3691102R0001 ESB63-40 7 GHE3291202R0004 ESB24-04 5 GHE3691102R0002 ESB63-40 7 GHE3291202R0006 ESB24-04 5 GHE3691102R0003 ESB63-40 7 GHE3291202R0007 ESB24-04 5 GHE3691102R0004 ESB63-40 7 GHE3291202R1004 ESB24-04 5 GHE3691102R0006 ESB63-40 7 GHE3291302R0001 ESB24-22 5 GHE3691102R0007 ESB63-40 7 GHE3291302R0002 ESB24-22 5 GHE3691102R0008 ESB63-40 7 GHE3291302R0003 ESB24-22 5 GHE3691102R1004 ESB63-40 7 20 | ABB Index Types Type Order code EH04-11 GHE3401321R0002 Page 19 GHE3291702R0004 5 GHE3691102R0004 EH04-20 GHE3401321R0001 19 GHE3291702R0006 5 GHE3691102R0006 7 EN20-20 GHE3221101R0001 14 GHE3291702R0007 5 GHE3691102R0007 7 7 GHE3221101R0006 14 EN24-30 GHE3261501R0006 15 EN24-31 GHE3261601R0001 EN24-40 Type Order code Page Type Order code Page 7 GHE3291702R1004 5 GHE3691102R0008 GHE3291302R0001 5 GHE3691102R1004 7 15 GHE3291302R0002 5 ESB-DIS GHE3201902R0001 19 GHE3261601R0006 15 GHE3291302R0003 5 ESB-PLK24 GHE3201903R0001 19 GHE3261101R0001 15 GHE3291302R0004 5 ESB-PLK40/63 GHE3401903R0002 19 GHE3261101R0006 15 GHE3291302R0006 5 SZ-KZS GHS2101946R0004 19 EN40-20 GHE3421401R0006 16 GHE3291302R0007 5 SZ-KZS/1 GHS2101946R0005 19 EN40-30 GHE3421501R0006 16 GHE3291302R1004 5 SZ-KZS/6 GHS2101946R0010 19 EN40-31 GHE3421601R0001 16 GHE3291602R0001 5 SZ-KZS/9 GHS2101946R0013 19 19 EN40-40 ESB20-02 ESB20-11 ESB20-20 ESB24-04 ESB24-13 ESB24-22 ESB24-31 GHE3421601R0006 16 GHE3291602R0002 5 SZ-KZS/10 GHS2101946R0014 GHE3421101R0001 16 GHE3291602R0003 5 SZ-KZS/11 GHS2101946R0015 19 GHE3421101R0004 16 GHE3291602R0004 5 SZ-KZS/12 GHS2101946R0016 19 GHE3421101R0006 16 GHE3291602R0006 5 SZ-KZS/13 GHS2101946R0017 19 GHE3211202R0001 4 GHE3291602R0007 5 GHE3211202R0002 4 GHE3291602R1004 5 GHE3211202R0003 4 GHE3291102R0001 5 GHE3211202R0004 4 GHE3291102R0002 5 GHE3211202R0005 4 GHE3291102R0003 5 GHE3211202R0006 4 GHE3291102R0004 5 5 ESB24-40 GHE3211202R0007 4 GHE3291102R0006 GHE3211202R1004 4 GHE3291102R0007 5 GHE3211202R1005 4 GHE3291102R1004 5 GHE3211302R0001 4 GHE3211302R0002 4 ESB40-20 ESB40-22 GHE3491402R0001 6 GHE3491402R0006 6 GHE3211302R0003 4 GHE3211302R0004 4 GHE3211302R0005 4 GHE3211302R0006 4 GHE3491502R0006 6 GHE3211302R0007 4 GHE3491502R0007 6 GHE3211302R1004 4 GHE3491602R0001 6 GHE3211302R1005 4 GHE3211102R0001 4 ESB40-30 ESB40-31 ESB40-40 GHE3491302R0001 6 GHE3491302R0006 6 GHE3491502R0001 6 GHE3491602R0006 6 GHE3491102R0001 6 GHE3211102R0002 4 GHE3491102R0002 6 GHE3211102R0003 4 GHE3491102R0003 6 GHE3211102R0004 4 GHE3491102R0004 6 GHE3211102R0005 4 GHE3491102R0006 6 GHE3211102R0006 4 GHE3491102R0007 6 GHE3211102R0007 4 GHE3491102R0008 6 GHE3211102R1004 4 GHE3491102R1004 6 GHE3211102R1005 4 ESB63-11 GHE3691802R0006 7 GHE3291202R0001 5 ESB63-20 GHE3691402R0001 7 GHE3291202R0002 5 GHE3291202R0003 5 ESB63-22 GHE3291202R0004 5 ESB63-30 GHE3291202R0006 5 GHE3291202R0007 5 GHE3291202R1004 5 ESB63-31 GHE3691402R0006 7 GHE3691302R0007 7 GHE3691502R0006 7 GHE3691502R0007 7 GHE3691602R0004 7 GHE3691602R0006 7 GHE3291702R0001 5 GHE3691102R0001 7 GHE3291702R0002 5 GHE3691102R0002 7 GHE3291702R0003 5 GHE3691102R0003 7 ESB63-40 ABB | 21 ABB France Low Voltage Products Division 10, rue Ampere Z.I. - B.P. 114 F-69685 Chassieu cedex / France ABB STOTZ-KONTAKT GmbH Eppelheimer Strae 82 D-69123 Heidelberg / Germany Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents - in whole or in parts - is forbidden without prior written consent of ABB. Copyright(c) 2011 ABB All rights reserved You can find the address of your local sales organisation on the ABB home page http://www.abb.com/contacts -> Low Voltage products www.abb.com/lowvoltage 1SBC 103 001 C0202 - Printed in France (W 10.2011 Ferreol) Contact us