Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 29513 Composite - 1000V UL Flexible Motor Supply Cable For more Information please call 1-800-Belden1 General Description: 1 pr.(Signal)-16 AWG stranded (26x30) TC cond., XLPE insul., Beldfoil(R) shield (100% c; 3 cond.(VFD) plus 1 ground wire-10 AWG stranded (105x30) TC cond., XLPE insul., Duofoil(R) and TC braid Shield (100% acdrain, PVC jacket. Usage (Overall) Suitable Applications: AC Motor Drive, VFD, Variable Frequency Drive Twisted Pair Physical Characteristics Conductor AWG: # Pairs AWG Stranding Conductor Material 1 16 26x30 TC - Tinned Copper Insulation Insulation Material: Insulation Material Dia. (mm) XLPE - Cross Linked Polyethylene 0.762 Twisted Pair Color Code Chart: Number Color 1 Black and White Inner Shield Inner Shield Material: Inner Shield Trade Name Type Inner Shield Material Beldfoil(R) Coverage (%) Tape Aluminum Foil-Polyester Tape 100 Inner Shield Drain Wire AWG: AWG Stranding Conductor Material 18 19x30 TC - Tinned Copper Electrical Characteristics Nom. Capacitance Conductor to Conductor: Capacitance (pF/m) 111.554 Nom. Conductor DC Resistance: DCR @ 20C (Ohm/km) 13.124 Nom. Inner Shield DC Resistance: DCR @ 20C (Ohm/km) 16.372 Multi Conductor Physical Characteristics Conductor AWG: # Conductors AWG Stranding Conductor Material Page 1 of 4 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 29513 Composite - 1000V UL Flexible Motor Supply Cable 1 10 105x30 TC - Tinned Copper Ground Wire Ground Wire (Y/N): Yes Ground Wire Material: AWG Stranding Conductor Material Insulation Material 10 105x30 TC - Tinned Copper PVC - Polyvinyl Chloride Insulation Insulation Material: Insulation Material Dia. (mm) XLPE - Cross Linked Polyethylene 1.143 Insulation Color Code Chart: Number Color 1 Black #1 2 Black #2 3 Black #3 4 Green/Yellow Outer Shield Outer Shield Material: Layer # Outer Shield Trade Name Type Outer Shield Material 1 Duofoil(R) Coverage (%) Tape Aluminum Foil-Polyester Tape-Aluminum Foil 100.000 2 Braid TC - Tinned Copper 85.000 Outer Shield Drain Wire AWG: AWG Stranding Drain Wire Conductor Material 10 105x30 TC - Tinned Copper Electrical Characteristics Nom. Inductance: Inductance (H/m) 0.604 Nom. Capacitance Conductor to Shield: Capacitance (pF/m) 173.893 Nom. Capacitance Conductor to Conductor: Capacitance (pF/m) 95.149 Nom. Conductor DC Resistance: DCR @ 20C (Ohm/km) 3.242 Physical Characteristics (Overall) Conductor Outer Jacket Outer Jacket Material: Outer Jacket Material Nom. Wall Thickness (mm) PVC - Polyvinyl Chloride 2.667 Outer Jacket Ripcord: Yes Overall Cable Overall Nominal Diameter: 25.019 mm Mechanical Characteristics (Overall) Operating Temperature Range: -40C To +90C Max. Recommended Pulling Tension: 3193.808 N Min. Bend Radius/Minor Axis: 251.460 mm Page 2 of 4 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 29513 Composite - 1000V UL Flexible Motor Supply Cable Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: RHW-2 Singles, TC-ER, XHHW-2 NEC Articles: 336 - ER CEC/C(UL) Specification: 600V Type CIC TC CSA Specification: 1000 V AWM I/II A/B EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 09/21/2006 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Other Specification: 1000V UL Flexible Motor Supply Cable Flame Test UL Flame Test: UL1685 UL Loading CSA Flame Test: FT4 IEEE Flame Test: 1202, IEEE 383 Vertical Tray Flame Test (70,000 BTU) Suitability Suitability - Indoor: Yes Suitability - Outdoor: Yes Suitability - Burial: Yes Sunlight Resistance: Yes Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Max. Operating Voltage - UL: Voltage 1000 V RMS (Flexible Motor Supply Cable) Max. Operating Voltage - Other: Voltage 1000 V RMS (CSA AWM I/II A/B Put Ups and Colors: Item # Putup Ship Weight Color Notes Item Desc 29513 010100 30 MT 40.506 KG BLACK C COMPOSITE CABLE SH PVC 29513 0101000 305 MT 255.374 KG BLACK C COMPOSITE CABLE SH PVC 29513 0103000 914 MT 757.956 KG BLACK C COMPOSITE CABLE SH PVC 29513 010500 152 MT 129.955 KG BLACK C COMPOSITE CABLE SH PVC Notes: C = CRATE REEL PUT-UP. Page 3 of 4 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 29513 Composite - 1000V UL Flexible Motor Supply Cable Revision Number: 1 Revision Date: 08-20-2013 (c) 2013 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 4 of 4 10-30-2013