Digital Multimeter Series Series Series of 4.5-digit Handheld Multimeters Series of 3.5-digit Handheld Multimeters Series of 3.5-digit Handheld Multimeters of 3.5-digit Pocket Digital Multimeter Pocket DMM 0.09% Accuracy RMS Measurement Low-end Model 0.020% Maximum Measurement Accuracy Bulletin DMM-E Glossary Integral Action Time Frequency Characteristic Refers to a characteristic that shows variations in input, measurement, or response with frequency. When measuring alternating current signals, a measured signal does not have a simple frequency, but often includes various frequencies ranging from lower frequencies to higher harmonics. To measure such signals more accurately, it is preferable to use a measurement device that has a broader frequency characteristic range. Digital multimeters (DMMs) employ an A/D converter with a dual-integration system, which determines the measurement value by converting the input voltage into time using an integration AD converter. The interval to perform an integral action periodically is referred to as the integralaction time. Measurement Accuracy With DMMs, the measurement accuracy is generally expressed as: __% of reading + __digits. ("Reading" refers to the reading value, and is abbreviated as "rdg"; "digits" refers to the number displayed in the smallest decimal place, and is abbreviated as "dgt.") This expresses the range of values that a DMM may measure or represent for a given actual value. Input Impedance To prevent the measured object from being influenced during voltage measurement, you should use a measurement device with an extremely high input impedance. Root Mean Square Value Decibel The value most directly related to the energy of a given waveform. Refers to the square root of a value found by averaging the squares of instantaneous values of a waveform over a single cycle. (See Table 1,Figures 1 and 2.) A unit used for describing the change in electrical signal amplitude or noise level, or transmission systems in wired devices, etc. This parameter is also used to represent the level differences in voltage, current or related values, but is generally restricted to cases characterized by the relationship: (I1/I2)2 = (V1/V2)2 = P1/P2. In the abbreviation "dB," "d" (deci) denotes 1/10, and "B" (Bell) denotes logarithm. Mean Value Refers to the average of the sum of instantaneous values, determined for a current half-wave. It is equivalent to calculating the surface area of a waveform. Table 1. RMS Value, Average Value, Waveform Factor and Crest Factor for a Typical Periodic Waveform Form Factor Item Ratio of RMS value with respect to average value. Form factor = RMS value/mean value (See Figures 1 and 2.) Waveform RMS Mean value Waveform factor Crest factor Sine wave Half rectification wave Full rectification wave Crest Factor Ratio of maximum value to RMS value. Crest factor = maximum value/RMS value(See Figures 1 and 2.) Triangular wave Peak-to-Peak (P-P) value Refers to the distance between the smallest and largest amplitudes in a waveform (see Figure 1). Square wave Figure 1. RMS and Mean Values of Sine Wave Figure 2. RMS of Distorted Waves Instantaneous value and spectrum RMS value (energy) Ep (crest value) Ep (Amplitude) Mean value DC component Fundamental wave Harmonic component component RMS of each spectrum (surface area) E (RMS value) Emean (mean value) E (RMS value) Emean (mean value) Calibration of RMS value by mean value rectification RMS value Crest factor (CF) CF = Crest value RMS value Waveform factor = RMS value mean value P-P value CE Mark Measurement categories (CAT) The products of Yokogawa Meters & Instruments Corporation are subjected to design and evaluation testing to ensure compliance with the safety and EMC standards in accordance with the directives issued by the EC. In order to ensure the safety of the user, IEC 60664 defines the ranges of use of measuring instruments by classifying power levels into measurement categories II through IV and O (None, other). This is because the excessive impulse or surge levels induced in a power line vary depending on the location of measurement (category). Categories with higher numerals designate locations that include larger surge voltages. Instruments that are designed for category III can thus withstand higher surge voltages than instruments designed for category II. Electromagnetic Compatibility (EMC) The parameters EMI and EMS are referred to as electromagnetic compatibility as they relate to compatibility within an electromagnetic environment. Safety Standards These standards lay out safety requirements that are to be met by a product with the objective of the preservation of human life and property. The applicable international standard is IEC 61010, and while a product must conform to this standard, there are also domestic standards laid out by individual countries. With these safety regulations, the range of use of a measurement device is specified by categorization in measurement categories I through IV to ensure the safety of the user. The designations "CAT II, 1000 V" or "CAT III, 600 V" at the input terminals of a measurement device, for example, indicates the applicable category and the maximum voltage for the device in terms of safety. Measurement category O (None, other) 1 Internal wiring Service drop Outlet Description Remarks Other circuits that are not directly connect to MEAINS. For measurement performed on circuits directly connected to the low-voltage installation. Appliances, portable equipments, etc. For measurement performed in the building installation. Switchboard, circuit breaker, etc. For measurement performed at the source of the low-voltage installation. Overhead wire, cable systems, etc. 73101 Pocketsized .V alu e al rG Ba raph ckAC lit RM S Vo lta ge AC + Cu DC rre AC nt + Re DC A sis Co tanc e nti n Dio uity Ch de ec Fre Test k qu e nc Te y mp e Ca ratu r pa cit e a Fil ter nce Co mm Da unic ta ati Ma Mem on o x./ ry Re Min. Va lat lu i Lo ve Va e M ga e rith lue C mor y Da m o m Co ta Ho mp puta Au tio l uta d to n tio Ho n Pe ld ak Ov Hold erv PC oltag e Co nn Inpu Au tW ec to arn Po tion ing we rO Ex f f ter na lV iew Ba Du Ma x e Typ el Mo d Digital Multimeter Selection Guide Display Measurement Items TY710 50000 TY720 TY520 6000 TY530 Handheld 73201 73202 4300 73203 73204 4300 : Also functions as excessive current input warning. 2 Additional Functions Most Reliable Handheld Digital Multimeters Series Maximum Measurement Accuracy 0.020% rdg + 2 dgt (DC voltage) True RMS measurement Model TY720 TY710 Safe Design Conforms to EN61010-1 safety standard 4.5 50,000 count Conforms to measurement category 1000 V AC/DC, CAT and 600 V AC/DC, CAT RMS USB Shutters prevent erroneous insertion of test leads into current measurementterminals (terminal shutters) Terminal shutters 0.020% LPF AC50mV digits (TY720) The current terminals have terminal shutters that prevent erroneous setting of the measurement function and leadwire connections resulting from operational errors. The terminal shutters open and close according to the function switch position. (DCV) (TY720) Closed Case Calibration User calibration function The TY series, simply performing special operations via front panel allows for quick and reliable adjustment. In addition, the series allows for onetouch adjustment of AC voltage- and AC current-to-frequency characteristics. The user calibration function leads to improved operation efficiency and cost reduction. * External standard instrument required for calibration. Full Support for Data Management Two memory modes Real-time measurement * SAVE-mode memory A mode for manually saving any data * Logging-mode memory A mode for automatically saving data at a specified interval Logging interval: 1 second to 30 minutes The optional communication package*1 sold separately (Model 92015) allows you to connect to a PC for transmitting large amounts of data that cannot be saved in the DMM internal memory. You can transmit the saved data from the internal memory to a PC and process it using application software or spreadsheet software (Excel*2) for data management. *1 Communication cable and application software are included. *2 Excel is a registered trademark of Microsoft Corporation in the United States. *3 The communication cable employs an infrared system, so the device is electrically insolated. Memory capacity Model SAVE-mode memory* Logging-mode memory* TY710 For details of the application software, refer to page 7. 1000 100 10000 TY720 * Saved data can be checked on the display. Loaded with Measurement Functions Peak hold function (TY720, for DC V/A measurement) Minimum/maximum/average display Supports waveforms of 1 ms or greater. You can capture instantaneous crest values not possible with ordinary maximum measurement functions. Allows recording of minimum, maximum and average values along with their respective times (time passed since the start of measurement) Relative and percentage value computation Decibel calculation Can display the measured values as the values relative to a reference value (defined by the REL key; even after data hold) or as the percentages of the reference value. Percentage calculation: (Measured value - reference value) / (reference value), expressed as percentage. Computes the logarithm of an alternating current, and uses it together with the relative value computation to display the relative value. You can select the standard resistance according to the application, such as audio or communication circuit signal measurement. * Selectable standard resistance values: 4/8/16/32/50/75/93/110/125/135/150/200/250/300/500/600/800/900/1000/1200 Duty ratio (%) measurement Full Display Functions Displays the duty ratio of a pulse waveform: (High level period/1 cycle of waveform) x 100 = (t2/t1) x 100 [%] 50,000-count, 51-segment bar graph display Backlight provided as standard for when working in dark places. Simultaneous display of frequency and voltage, frequency and duty ratio or decibels and voltage on the dual display. Display: V AC and V DC measurements Sub-display AC+DC measurement Measures RMS of a waveform in which ripple waveforms are superimposed on a direct current. Auto hold In addition to the above, the sub-display can display the reference value for differential calculation, memory storage numbers for measured data, minimum/maximum/average value recording times, and standard resistance during decibel calculation. Automatically hold the data measured when the test leads are disconnected from the measured object, thus freeing both hands for performing reliable measurement. 3 TY700 General Specifications Model and Specification Code Measurement Functions :DC voltage, AC voltage, DCV+ACV, DC current, AC current, DCA+ACA, resistance, frequency, temperature, capacitance, duty cycle, decibel calculation, continuity check, diode test, low-power resistance (TY720 only) For AC voltage/current, RMS/MEAN detection can be switched (TY720 only). For AC voltage/current, the low-pass filter can be turned on/off (TY720 only). Additional Functions :Data hold/auto hold/peak hold (TY720 only), range hold, maximum/minimum/average values resistance, capacitance zero, relative and percentage value calculation, manual-mode memory, logging-mode memory, auto power off, backlight (white LED) Display :5-digit LCD: 7-segment Digital display: Main display; [50,000] counts Sub-display ; [50,000] counts Bar graph display: 51-segment Polarity indicator: "-" appears automatically when the polarity is negative Overrange indicator: "OL" Low-battery indicator: " + -- " appears at or below the minimum operating voltage. Measuring Rate :6 times/sec (Frequency: 1 time/sec, Capacitance: max. 0.03 times/sec (50mF), Resistance: 4 times/sec) Bar graph display: 15 times/sec Operating Temp. and Humidity :-20 to 55C; 80% RH or less (no condensation) 40 to 55C: 70% RH or less Storage Temp. and Humidity :-40 to 70C; 70% RH or less (no condensation) Temperature Coefficient :Add the accuracy 0.05/C to the basic accuracy at a temperature within -20 to 18C and 28 to 55C. For continuous measurements, add 1 digit/C for DC voltage (DCV) and DC current (DCA). (Add 3 digits/C for 50mV, 5A, and 10A ranges) Power Supply :Four AA (R6) dry cells Battery Life :Approx. 120 hours (for continuous DC voltage measurement with alkaline cells) Withstanding Voltage :6.88kV for 5 seconds (between input terminals and casing) Dimensions :Approx. 90(W) x 192(H) x 49(D) mm Weight :Approx. 560g (including batteries) Compliance with Standards :Safety EN61010-1, EN61010-2-030, EN61010-031, 1000V CAT#, 600V CAT$, pollution level 2, indoor, 2000m max. above sea level UL 61010-1, CAN/CSA-C22.2 No. 61010-1, UL 61010-031, CAN/CSA-C22.2 No. 61010-031 EMC: EN61326-1 Class B, EN55011 Class B Group 1, EN61326-2-2 Standard Accessories :AA (R6) dry cells: 4, Test lead set (98015): 1, Fuse (installed) 440mA/1000V and 10A/1000V, Instruction manual: 1 Name Model TY710 Digital Multimeter TY720 Optional Accessories Name Model Specification DMM communication package 92015 Test leads Test leads with Alligator Clip Fuse 98073 99014 99015 99016 90050 90051 90055 90056 96001 93029 USB communication adapter + USB communication cable + Application software 1000V CAT#, 600V CAT$ Red/black (1 set) 1000V CAT#, 600V CAT$ Red/black (1 set) 440 mA/1000V (1 piece/1 unit) 10 A/1000 V (1 piece/1 unit) -50 to 600C (For liquids) -50 to 600C (For liquids) -20 to 250C (For surfaces) -20 to 500C (For surfaces) For 400A, AC Output: 10mV/A, AC Hard type (Houses the DMM, the test leads and communication cable) TC-K temperature probe Current clamp probe Carrying case Performance Test conditions: Temperature and humidity = 23 5C, 80% RH or less; Accuracy = (% rdg + dgt). Note: A response time is the time required for achieving the accuracy specified for the corresponding range. DC Current Measurement ( A) DC Voltage Measurement( V) Range Accuracy TY710,TY720 0.05+10 Resolution Input Resistance Maximum Input Voltage 50mV 0.001mV 500mV 0.01mV Approx. 100M 0.02+2 2400mV 0.1mV 5V 0.0001V 0.025+5 50V 0.001V 10M 500V 0.01V 0.03+2 1000V 0.1V NMRR: 80dB or greater for 50/60Hz 0.1%At 50mV of range, 70dB or greater for 50/60Hz 0.1% CMRR: 100dB or greater for 50/60Hz(Rs=1k) Response time: 0.3 seconds or less 1000V DC 1000V rms AC Accuracy Range Resolution TY710,TY720 500A 0.01A 5000A 0.1A 0.2+5 50mA 0.001mA 500mA *3 0.01mA 5A 0.0001A 0.6+10 10A 0.001A 0.6+5 Response time: 0.3 seconds or less *3: Maximum testing current at 500mA of range is 440mA Voltage Drop <0.11mV/A Maximum Input Current 440mA fuse-protected <4mV/mA 10A fuse-protected <0.1V/A AC Voltage Measurement [RMS] (~V) AC coupling, RMS detection, crest factor for 1000V of range: 1.5 ; crest factor for ranges other than 1000V: 3 Accuracy (Upper: TY710; Lower: TY720; the display of "--" is not specified) Input Maximum Range Resolution 10 20Hz 1k 10k 20k 50k Impedance Input Voltage 20Hz 1kHz 10kHz 20kHz 50kHz 100kHz -- -- -- -- -- 50mV 0.001mV 15+40*2 0.4+40*2 5+40*2 5.5+40*2 2+80*2 11M<50pF 500mV 0.01mV 1000V rms AC 2+50*2 -- -- 5V 0.0001V 1.5+30*1 0.7+30*1 1000V DC 1+40*1 2+70*2 5+200*2 50V 0.001V 1+30*1 0.4+30*1 500V 0.01V 10M<50pF 2 2 2 3+30* -- * * 1000V 0.1V 3+30*2 -- *2 *2 *1: At 5 to 100% of range *2: At 10 to100% of range CMRR: 80dB or greater for DC to 60Hz(Rs= 1k) Response time: 1 second or less AC Current Measurement [RMS] (~A) RMS detection crest factor: 3 Maximum Input Accuracy (Upper: TY710; Lower: TY720; the display of "--" is not specified) Range Resolution Voltage Drop Current 10 - 20Hz 20Hz - 1kHz 1k - 5kHz 500A 0.01A <0.11mV/A 440mA -- 5000A 0.1A 1.5+20 1+20 fuse-protected 50mA 0.001mA 1+20 0.75+20 1+30 <4mV/mA 500mA *3 0.01mA 10A -- 5A 0.0001A 1.5+20 1+20 <0.1V/A 10A 0.001A 1.5+20 1+20 2+30 fuse-protected Shown above is the accuracy at 5 to 100% of range (10 to 100% for 10A range). Response time: 1 second or less *3: Maximum testing current at 500mA of range is 440mA. AC Voltage Measurement [MEAN] (~V) AC Voltage Measurement [MEAN] (~A) AC coupling, Mean-value detection and RMS-value calibration (sinusoidal wave) Accuracy TY720 20 - 500Hz 1.5+30*2 Range Mean-value detection and RMS-value calibration (sinusoidal wave) Accuracy TY720 20 - 500Hz Resolution 50mV 0.001mV 500mV 0.01mV 11M<50pF 1000V rms AC 5V 0.0001V 1000V DC 1+30*1 3+30*1 2+30*1 50V 0.001V 500V 0.01V 10M<50pF 1000V 0.1V *2 *2 *2 *1: At 5 to 100% of range *2: At 10 to 100% of range CMRR: 80dB or greater for DC to 60Hz (Rs= 1k) Response time: 1 second or less Voltage Drop 10 - 20Hz 500Hz - 1kHz 500A 0.01A <0.11mV/A 5000A 0.1A 2+20 1.5+20 2+30 50mA 0.001mA <4mV/mA 500mA *3 0.01mA 5A 0.0001A 3+20 2+20 4+30 <0.1V/A 10A 0.001A Shown above is the accuracy at 5 to 100% of range (10 to 100% for 10A range). Response time: Approx. second or less *3: Maximum testing current at 500mA of range is 440mA. DCV + ACV ( +~) DCA + ACA ( +~) Range Resolution 10 - 20Hz 4+80*2 Range 5V 50V 500V Resolution 0.0001V 0.001V 0.01V 500 - 1kHz 5+30*2 Input Impedance Maximum Input Voltage AC coupling, RMS detection crest factor for 1000V of range: 1.5 ; crest factor for ranges other than 1000 V: 3 Accuracy (Upper: TY710; Lower: TY720; the display of "--" is not specified) Input Maximum DC,1k DC,10k DC,20k DC,50k DC,10 DC,20Hz Impedance Input Voltage 20Hz - 1kHz 10kHz 20kHz 50kHz 100kHz 11M<50pF 1.5+10*1 1+10*1 2+10*2 -- -- 1.5+10*1 0.5+10*1 1+10*1 2+10*2 5+20*2 1000V rms AC 10M<50pF 1000V DC *2 -- *2 1000V 0.1V -- *2 *2 *1: At 5 to 100% of range *2: At 10 to 100% of range CMRR: 80dB or greater for DC to 60Hz (Rs = 1k) Response time: Approx. 2 seconds Resistance Measurement () Accuracy Maximum Testing Open-circuit Current Voltage 500 0.01 <1mA 5k 0.0001k <0.25mA 0.1+2*1 0.05+2*1 50k 0.001k <25A <2.5V 500k 0.01k <2.5A 5M 0.0001M 0.5+2 <1.5A 50M 0.001M 1+2 <0.13A *1: Accuracy after zero calibration Response time: 1 second or less for 500 to 500k, 5 seconds or less for 5M to 50M Range Resolution TY710 TY720 Low-power Resistance Measurement (LP-) Accuracy Range Resolution TY720 5k 0.001k 50k 0.01k 0.2+3 500k 0.1k 5M 0.001M 1+3 Continuity Check ( ) Range Resolution 500 0.1 Continuity Beeper TY710, TY720 Buzzer sounds at 100 50 or less. Input Protection Voltage 1000V rms Maximum effective display: 5000 Maximum Testing Current <10A <1.0A <0.6A <0.05A Testing Current Approx. 0.5mA Open-circuit Voltage Input Protection Voltage <0.7V 1000V rms Maximum effective display: 5000 Open-circuit Voltage Input Protection Voltage <5V 1000V rms Range Resolution Maximum Input Current 440mA fuse-protected 10A fuse-protected Maximum effective display: 50,000, crest factor: 3 Accuracy (Upper: TY710; Lower: TY720; the display of "--" is not specified) Maximum Input Voltage Drop Current DC,10 - 20Hz DC,20Hz - 1kHz DC,1k - 5kHz 500A 0.01A <0.11mV/A 440mA 5000A 0.1A 2+10 1.5+10 -- fuse-protected 50mA 0.001mA 1.5+10 1+10 1.5+10 <4mV/mA 3 500mA * 0.01mA 10A -- 5A 0.0001A 2+10 1.5+10 <0.1V/A 10A 0.001A 2+10 1.5+10 3+10 fuse-protected Shown above is the accuracy at 5 to 100% of range (10 to 100% for 10A range). Response time: Approx. 2 seconds *3: Maximum testing current for 500mA of range is 440mA. Diode Test ( ) Range Resolution 2.4V 0.0001V Accuracy TY710,TY720 1+2 Testing Current (Vf = 0.6 V) Approx. 0.5mA Temperature Measurement (TEMP) Range Resolution AccuracyTY710,TY720 Input Protection Voltage -200 - 1372C 0.1C 1+1.5C 1000V rms Temperature probe: Type K thermocouple sensor (optional) Capacitance ( ) Maximum effective display:5000 Range Resolution AccuracyTY710,TY720 Input Protection Voltage 5nF 0.001nF 50nF 0.01nF 500nF 0.1nF 1+5*1 5F 0.001F 1000V rms 50F 0.01F 500F 0.1F 2+5 5mF 0.001mF 3+5 50mF 0.01mF *1: Accuracy after zero calibration Open-circuit Voltage <5V Frequency Measurement (Hz) AC coupling, Maximum effective display: 9999 Range (auto-ranging) Resolution Accuracy TY710,TY720 2.000 - 9.999Hz 0.001Hz 9.00 - 99.99Hz 0.01Hz 0.02+1*1 90.0 - 999.9Hz 0.1Hz 0.900 - 9.999kHz 0.001kHz 9.00 - 99.99kHz 0.01kHz *2 *1: At 10 to 100% of input voltage or current range *2: At 40 to 100% of input voltage or current range Duty Cycle (%) Range Resolution Accuracy TY710,TY720 10 - 90% 1% 1%*1 *1: For input of a square wave with a frequency within 10.00 to 500.0Hz At 40 to 100% of input voltage or current range Peak Hold Function (PH) TY720 only Range DCV, DCA 4 Input Protection Voltage 1000V rms Maximum effective display: 5000 Accuracy TY720 100 digit Response Time >250s Safe design and supports various maintenance applications. Series Maximum Reliability and Safety Reliability High accuracy and safety Model TY530 TY520 3.5 digits RMS Accuracy: 0.09% rdg + 2 dgt (DC voltage) True RMS measurement Only TY530 can switch RMS and mean detection. Safe Design 6000 Conforms to EN61010-1 safety standard. count Conforms to overvoltage category 1000 V AC/DC, CAT and 600 V AC/DC, CAT IV. USB (TY530) Terminal shutters 0.09% Sensor LPF Shutters prevent erroneous insertion of test leads into current measurement terminals (terminal shutters). If the function is switched to other than current measurement while a test lead remains inserted in a current measurement terminal, the fuse built into the DMM can not protect the circuits. The terminal shutters prevent such accidental errors. (DCV) Closed Case Calibration User calibration function The TY series, simply performing special operations via front panel allows for quick and reliable adjustment. In addition, the series allows for onetouch adjustment of AC voltage- and AC current-to-frequency characteristics. The user calibration function leads to improved operation efficiency and cost reduction. * External standard instrument required for calibration. Direct reading of various sensor output signals Data Storage Method The DMM can directly read the various sensor output signals (mV DC/AC) at any scaling. The units can be changed (16 units are available). Output signal and scaled value are simultaneously displayed. Two memory modes (TY530 only) Selectable from 2 types of memory mode to suit field needs. * SAVE-mode memory A mode for manually saving any data * Logging-mode memory A mode for automatically saving data at a specified interval Sub-display Sensor output signal Memory capacity Main display Scaled value Model SAVE-mode memory Logging-mode memory TY530 100 1600 Real-time measurement Small motor The optional communication package*1 sold separately (Model 92015) allows you to connect to a PC for transmitting large amounts of data that cannot be saved in the DMM internal memory. You can transmit the saved data from the internal memory to a PC and process it using application software or spreadsheet software (Excel*2) for data management. *1 Communication cable and application software are included. *2 Excel is a registered trademark of Microsoft Corporation in the United States. *3 The communication cable employs an infrared system, so the device is electrically insolated. For details of the application software, refer to page 7. Power supply AC/DC clamp-on probe (Model 96095) Reads maximum 60 A when used with the TY500 series. 5 TY500 General Specifications Model and Specification Code Measurement Functions :DC Voltage, AC voltage, DC current, AC current, resistance, frequency, temperature, capacitance, continuity check, diode test For AC voltage/current, RMS/MEAN detection can be switched (TY530 only). Low-pass filter can be switched on/off Additional Functions :Data hold/auto hold/range hold, maximum/minimum/average values (TY530 only), resistance, relative and percentage value calculation, memory function (TY530 only), communication function (TY530 only), logging-mode memory (TY530 only), auto power off, backlight Display :3.5-digit LCD: 7-segment Digital display: [6000] counts Bar graph display: 31-segment Polarity indicator: "-" appears when the polarity is negative Overrange indicator: "OL" Low-battery indicator: " + -- " appears at or below the minimum operating voltage. Measuring Rate :5 times/sec (Frequency: 1 time/sec, Capacitance: max. 0.14 times/sec (1000F), Resistance: 2.5 times/sec, Temperature: 0.7 times/sec), Bar graph display: 25 times/sec (DC voltage, diode test: 5 times/sec) Operating Temp. and Humidity :-10 to 55C; 80% RH or less (no condensation) 40 to 55C; 70% RH or less Storage Temp. and Humidity :-30 to 70C; 70% RH or less (no condensation) Temperature Coefficient :Add the accuracy 0.1/C to the basic accuracy at a temperature within -10 to 18C and 28 to 55C. Power Supply :Four AA (R6) dry cells Battery Life :Approx. 300 hours (for continuous DC voltage measurement with alkaline cells) Withstanding Voltage :6.88kV for 5 seconds (between input terminals and casing) Dimensions :Approx. 90(W) x 192(H) x 49(D) mm Weight :Approx. 570g (including batteries) Compliance with Standards :Safety EN61010-1, EN61010-2-030, EN61010-031, 1000V CAT#, 600V CAT$, pollution level 2, 2000m max. above sea level UL 61010-1, CAN/CSA-C22.2 No. 61010-1, UL 61010-031, CAN/CSA-C22.2 No. 61010-031 EMC: EN61326-1 Class B, EN55011 Class B Group 1, EN61326-2-1 Standard Accessories :AA (R6) dry cells: 4, Test lead set (98015): 1, Fuse (installed) 440mA/1000V and 10A/1000V, Instruction manual: 1 Name Model TY520 Digital Multimeter TY530 Optional Accessories Name Model Specification DMM communication package 92015 Communication package for printer Test leads Test leads with Alligator Clip Fuse 97016 98073 99014 99015 99016 90050 90051 90055 90056 96001 96030 96031 96032 96033 96034 96035 93029 USB communication adapter + USB communication cable + Application software Printer adapter + Printer cable 1000V CAT #, 600V CAT $ Red/black (1 set) 1000V CAT #, 600V CAT $ Red/black (1 set) 440mA/1000V (1 piece/1 unit) 10A/1000V (1 piece/1 unit) -50 to 600C (For liquids) -50 to 600C (For liquids) -20 to 250C (For surfaces) -20 to 500C (For surfaces) For 400A,AC Output: 10mV/A, AC 200A,AC 500A,AC 700A,AC 50A,AC 3000A,AC 3000A,AC Hard type (Houses the DMM, the test leads and communication cable) TC-K temperature probe TC-K temperature probe Current clamp probe Carrying case Performance Test conditions: Temperature and humidity = 23 5C, 80% RH or less; Accuracy = (% rdg + dgt). Note: A response time is the time required for achieving the accuracy specified for the corresponding range. DC Voltage Measurement( V) Range DC Current Measurement ( A) Resolution Accuracy TY520, TY530 Input Resistance 600mV 0.1mV 6V 0.001V 0.09+2 60V 0.01V 600V 0.1V 1000V 1V 0.15+2 NMRR: 60dB or greater for 50/60Hz 0.1% CMRR: 120dB or greater for 50/60Hz (Rs = 1k) Response time: 1 second or less Range Maximum Input Voltage 10M 11M 1000V DC 1000V rms AC 10M Resolution Accuracy Voltage Drop 600A 0.1A 6000A 1A 0.2+2 60mA 0.01mA 0.1mA 600mA 6A 0.001A 0.5+5 10A 0.01A Maximum testing current at 600mA of range is 440mA. Response time: 1 second or less. AC coupling, RMS detection (TY530, TY520) crest factor: 3/mean-value detection (TY530 only) sinusoidal wave Accuracy Maximum Input Input Impedance Voltage 40-500Hz 500Hz - 1kHz 600mV 0.1mV 10M, <200pF 6V 0.001V 11M, <50pF 1.5+5 1000V rms AC 60V 0.01V 0.5+5 1+5 1000V DC 600V 0.1V 10M, <50pF 1000V 1V Shown above is the accuracy at 5 to 100% of range (200 to 1000V for 1000V range, peak 1500V or less). Response time: 2 seconds or less Add accuracy = (2% of reading + 2% of F.S.), except for sinusoidal wave. CMRR: 60dB or greater for DC to 60Hz (Rs = 1k). 4 counts or less is corrected to 0. <0.12mV/A Maximum Input Current 440mA fuse-protected <3.3mV/mA <0.1V/A 10A fuse-protected AC Voltage Measurement (~V) Range Resolution AC Current Measurement (~A) 50/60Hz Range Resolution 600 6k 60k 600k 6M 0.1 0.001k 0.01k 0.1k 0.001M Diode Test( Accuracy 0.4+1*1 Maximum Testing Current <1.2mA <110A <13A <1.3A Open-circuit Voltage <3.5V Input Protection Voltage Range (auto-ranging) 10.00 - 99.99Hz 90.0 - 999.9Hz 0.900 - 9.999Hz 9.00 - 99.99kHz NEW Resolution 0.01Hz 0.1Hz 0.001kHz 0.01kHz Input Voltage Range 0.2 - 600V rms 0.02+1 40Hz - 1kHz RMS detection crest factor: 3 Maximum Input Current Voltage Drop 440mA fuse-protected 10A fuse-protected ) Resolution 0.001V Accuracy 1+2 Testing Current (Vf=0.6V) Approx. 0.5mA Open-circuit Voltage <3.5V Input Protection Voltage 1000V rms Continuity Check( ) AC coupling, Maximum effective display: 9999 Accuracy Range 2V Range 600 1000V rms <1.3V 0.5+1 <130nA 1+2(0-40M) 60M 0.01M 2+2(40-60M) *1: Accuracy after zero calibration for 600 to 6k range. Response time: 2 seconds or less for 600 to 600k, 10 seconds or less for 6M to 60M. Frequency Measurement (Hz) 50/60Hz 600A 0.1A <0.12mV/A 6000A 1A 60mA 0.01mA 0.75+5 1.5+5 <3.3mV/mA 0.1mA 600mA 6A 0.001A <0.1V/A 10A 0.01A Shown above is the accuracy at 5 to 100% of range (2 to 10A for 10A range). Response time: 3 seconds or less Add accuracy = (2% of reading + 2% of F.S.), except for sinusoidal wave. 4 counts or less is corrected to 0. Resistance Measurement () Range Accuracy Resolution 0.4 - 600V rms 0.8 - 100V rms Capacitance( Resolution 0.1 Accuracy Buzzer sounds at 50+30 or less Testing Current (Vf=0.6V) Open-circuit Voltage Approx. 1.2mA <3.5V Input Protection Voltage 1000V rms Temperature Measurement (TEMP) ) Range Resolution Accuracy Input Protection Voltage 10nF 0.01nF 2+10*1 100nF 0.1nF 1F 0.001F 2+5 1000V rms 10F 0.01F 100F 0.1F 3+5 1000F 1F *1: Accuracy after zero calibration for 10nF to 1F range. Range Resolution Accuracy Input Protection Voltage -50 - 600C 0.1C 2+2C 1000V rms Temperature probe: Type K thermocouple sensor (optional) Accessory AC/DC clamp-on probe (Model 96095) Features A compact, light, and portable device with 12-mm caliber useful for tangled wiring. When used with this probe*1, the DMM can measure and display current (which it otherwise cannot do by itself). The TY500 series can directly read up to 60 A when used with the probe (in sensor mode). Specifications Model Diameter of measurable conductor Current to measure Basic performance 96095 12 mm max. Output voltage AC 0.1 to 130 A Output: 10 mV/A AC (AC 1 to 1300 mVrms) DC 0 to 180 A Accuracy (at 23C 5C) 50/60 Hz 40 Hz to 1 kHz 1.2%+0.4 mV 2.5%+0.4 mV 1.2% + 0.4 mV Output: DC10 mV/A (DC 0 to 1800 mV) General specifications -10 to 55C, 80%RH or less (no condensation) -30 to 70C, 85%RH or less (no condensation) AAA alkaline cell x 2 Power alert: LED light on at 2.2 V 0.2 V Auto power off at 1.9 V 0.2 V Approx. 35 hours (continuous) (until LED light on)*2 127(L) x 42(W) x 22(D) mm Cable length: 1200 mm Weight: Approx. 140 g (including cells) EN61010-1: CAT III 300V, pollution degree 2, operation at maximum altitude of 2,000 m, EN61010-2-032 EN61326-1: Class B, EN61326-2-2, EN55011 Class B Group 1 Soft carrying case (93040), Battery, User's manual Operating temperature and humidity Storage temperature and humidity Power supply Battery life Dimensions and weight Safety standard Accessories *1 Readings must be converted when used with the DMM. *2 After the battery alert, approx. 5 hours remain to automatic power-off. 6 92015 DMM Communication Package Communication Functions and Application Software Allow Analyses and Management of Measurement Data Data management by dedicated application software Example of document windows in DMM application software Data saved in the DMM can be managed by the dedicated application software (Model 92015). Saved data can be transmitted from the internal memory to a PC. Data collected in SAVE-memory mode or logging-memory mode Measurements by the DMM can be monitored on a PC in real time. Large amounts of data that cannot be saved in the DMM internal memory can be transmitted to a PC in real time. Data can be written to an Excel* spreadsheet. Maximum number of real-time data transmission: 32767 Measurement data can be laid out in an Excel spreadsheet. Graphs can be automatically created on a spreadsheet. * Excel is a registered trademark of Microsoft Corporation in the United States. 92015 Communications Package Specifications Specifications Communication cable Communication cable: IR communication adapter, USB communication cable: 1 Cable length: 2m Interface: USB 1.1 Supported models: TY710, TY720, TY530 Enlarged view USB communication Application software System requirements of PC Operating system: WindowsXP/Vista(*)/7 CPU: Pentium 133 MHz or higher TY720 Memory: 64 MB or larger Storage device: Hard disk with 10 MB or more free space CD-ROM drive: 1 Excel: Excel2003 or later (*) Contents: CD-ROM software: 1 Communication cable (communication adapter included): 1 User's manual * Windows and Excel is a registered trademark of Microsoft Corporation in the United States. Optional Accessories* * For TY710, TY720, and TY530 only Item DMM communication package Model Data layout on Excel spreadsheet Specification 92015 USB communication cable (adaptor included), application software 7 PC Data layout example on Excel spreadsheet Low-cost Handheld DMM Series General Specifications 73201 / 02 / 03 / 04 Additional Functions Display Measuring Rate Operating Temp.and Humidity Storage Temp.and Humidity Temperature Coefficient Model 73201 73202 73203 73204 Withstanding Voltage Power Supply Battery Life Auto Power Off Dimensions Weight Standard Accessories 3.5 digits 4300 :Auto hold, overvoltage and current warning :Digital display: 4300-count digital reading :Digital display: Approx. 2 times/sec :0 to 50C; 80% RH or less at 0C to 40C, or 70% RH or less at 40C to 50C (no condensation) :-20C to 60C, 70 RH or less (no condensation) :Add accuracy x 0.1/ C to the basic accuracy at a temperature within 0C to 18C and 28C to 50C :3.7 kV AC for 1 minute (between input terminals and casing, for 73201,73202, 73203) 5.55 kV AC for 1 minute (between input terminals and casing, for 73204) :Two AAA (LR03 or R03) dry cells :Approx. 600 hours (for continuous DC voltage measurement with alkaline cells) :The power is automatically turned off when no operation is made for approx. 20 minutes (can be disabled). N/A for 73204 :74 (W) x 155 (H) x 31 (D) mm :Approx. 240 g (including batteries) :User's manual: 1 Test lead set (RD031): 1 AAA (LR03/R03) dry cells (built in): 2 Spare fuse F05 (500 mA/250 V, not included for 73204): 1 Spare fuse F02 (15 A/250 V, not included for 73204): 1 count Optional Accessories Name Model Specification Fuse F05 F02 RD031 B9646GB 93007 500 mA/600 V 15 A/600 V Red / black (1 set) Houses the DMM and test leads For DMM Test leads Carrying case (hard) Rubber case * Compact size, ideal for carrying * Large display for easy viewing * Safe design allows measurement in excess of 20 A (excluding 73204) * Special model for voltage measurement (73204) * Simple auto hold function * Capacitors can be checked (73202/73203) Performance Test conditions: Temperature and humidity = 23C 5C, 80% RH or less;Accuracy = (% of reading + digits). Note: Response time is the time required for achieving accuracy specified for the corresponding range. DC Voltage Measurement ( Range V) Resistance Measurement ( Accuracy 73202/04 73201 73203 Input Resistance 400.0 mV >100 M 0.5% + 1 4.000 V 11 M 40.00 V 0.5% + 1 0.3% + 1 400.0 V 0.75% + 1 10 M 600 V Response time: 1.5 seconds or less for 400 mV range, 1 seconds or less for all other ranges AC Voltage Measurement ( Range V) 4.000 V 40.00 V 400.0 V 600 V Response time: 2 seconds or less DC Current Measurement ( Not available with 73204 Range Accuracy 73202 73201 73203/04 1% + 5 0.75% + 5 Maximum Input Voltage Accuracy Maximum Testing Open-circuit Input Protection 73201 to 73204 Current Voltage Voltage 400.0 0.75% + 2 <1 mA <3.4 V 4.000 k <0.5 mA <1.0 V 40.00 k 0.75% + 1 <70 A 600 V 400.0 k <7 A <0.7 V 4.000 M 2% + 1 <0.7 A 40.00 M 5% + 2 <70 A Response time: 1 second or less for 400 k range or less, 5 seconds or less for 4 M range, 15 seconds or less for 40 M range 600 V Mean-value detection and RMS-value calibration Maximum Input Input Resistance Voltage >11 M, <50 pF >10 M, <50 pF Continuity Check ( Continuity Beeper 73201 to 73204 400.0 Buzzer sounds at 50 20 or less Response time: 0.2 second or less (buzzer response) 600 Vrms Diode Test ( Accuracy 73202 73203 Voltage Drop Accuracy 73201 to 73204 2.00 V 1% + 1 (testing current 1 mA or less) Response time: 1 second or less Maximum Input Current Range Capacitor Check ( Range 73201 Mean-value detection and RMS-value calibration Accuracy (40 - 500 Hz) 73202 73203 2% + 20 2% + 5 2% + 20 2% + 5 Voltage Drop Maximum Input Current 400.0 A *1 <0.17 mV/A 4000 A 400 mA 40.00 mA *1 (500 mA/600 V fuse-protected) <3 mV/mA 400.0 mA 4.000 A 10 A 2.5% + 20 <0.04 V/A 10.00 A *2 (15 A/600 V fuse-protected) *1: Drift in the least significant digit may occur. *2: Measurement of 11 to 20 A can be performed within 30 seconds. A warning buzzer sounds when 30 seconds have passed. Response time: 2 second or less 8 Input Protection Voltage <3.4 V 600 V Open-circuit Voltage Input Protection Voltage <3.4 V 600 V ) 73201/04 20.00 nF 200.0 nF 2.000 F Not available 20.00 F 200.0 F Response time: 1 second or less A) Open-circuit Voltage ) Range 400.0 A *1 <0.17 mV/A 4000 A 400 mA 1% + 2 40.00 mA *1 (500 mA/600 V fuse-protected) <3 mV/mA 400.0 mA 4.000 A 10 A 2% + 2 <0.04 V/A 10.00 A *2 (15 A/600 V fuse-protected) *1: Drift in the least significant digit may occur. *2: Measurement of 11 to 20 A can be performed within 30 seconds. A warning buzzer sounds when 30 seconds have passed. Response time: 1 second or less AC Current Measurement ( Not available with 73204 ) Range A) 73201 ) Range Accuracy 73202 73203 2% + 5, typical (20 nF range: Accuracy after zero calibration) Input Protection 500 mA/250 V fuse-protected Pocket DMM with Superb Portability General Specifications 73101 Additional Functions Display Measuring Rate Operating Temp.and Humidity Storage Temp.and Humidity Power Supply Battery Life Model 73101 Auto Power Off Dimensions Weight Compliance with Standards 3.5 digits 4300 Standard Accessories count :Auto hold :Digital display: 4300-count digital reading :Digital display: Approx. 2 times/sec :0 to 50C; 80% RH or less (no condensation) :-10C to 60C, 70 RH or less (no condensation) :Two LR44 dry cell :Approx. 200 hours (for continuous DC voltage measurement) :The power is automatically turned off when no operation is made for approx. 20 minutes (can be disabled). :76 (W) x 117 (H) x 18 (D) mm :Approx. 110 g (including batteries) :Safety EN61010-2-30, EN61010-031, EN61010-1 (300 V, CAT II; contamination level 2) EMC EN61326-1, EN61326-2-2 EN55011 Class B Group 1 :User's manual: 1 LR44 dry cells: 2 Performance Test conditions: Temperature and humidity = 23C 5C, 80% RH or less;Accuracy = (% of reading + digits). DC Voltage Measurement ( Range 400.0 mV 4.000 V 40.00 V 400.0 V 600 V V) AC Voltage Measurement ( Range 4.000 V 40.00 V 400.0 V 600 V V) Accuracy 1.2 + 2 0.7 + 1 Input Resistance >100 M 11 M 1.2 + 1 10 M Resistance Measurement ( ) Range Accuracy 400.0 4.000 k 1.2 + 2 40.00 k 400.0 k 4.000 M 2.0 + 3 40.00 M 5.0 + 3 Maximum Input Voltage 600 V DC Accuracy 2.0 + 5 Mean-value detection and RMS-value calibration Input Resistance Maximum Input Voltage >11 M, <50 pF >10 M, <50 pF Continuity Check ( Range 400.0 600 Vrms Diode Test ( Range 2.00 V 9 Maximum Testing Current <1 mA <0.5 mA <70 A <7 A <0.7 A <70 nA Open-circuit Voltage <3.4 V <1.0 V Input Protection Voltage 600 V <0.7 V ) Continuity Beeper 50 20 Open-circuit Voltage <3.4 V Input Protection Voltage 600 V ) Accuracy 1.5 + 1 Testing Current <1.0 mA Open-circuit Voltage <3.4 V Input Protection Voltage 600 V Optional Accessories and Spare Parts Name DMM communication package Test leads Test leads with Alligator Clip Alligator clips Model Specification 92015 USB communication adapter + USB communication cable + Application software TY700 series TY530 98073 1000V CAT.III 600V CAT.IV Red/black (1set) All models except 73101 RD031 L-plug, Red/black (1set) 732 series 99014 1000V CAT.III 600V CAT.IV Red/black (1set) All models except 73101 Red/black(1set) All models B9646HF Fuse Rubber case Applicable DMM Models F02 15A/250V (3pcs/1set) F05 500mA/250V(3pcs/1set) 99015 440mA/1000V(1pc/1set) 99016 10A/1000V(1pc/1set) Carrying case 93029 Temperature (thermocouple type K) probe 98073 99014 73201/73202/73203 TY700/TY500 series 93007 B9646GB Appearance 732 series Hard case Hard case (Houses the DMM, the test leads and communication cable) 90050 -50C to 600C(for liquid) 90051 -50C to 600C(for liquid) 90055 -20C to 250C(for surface) 90056 -20C to 500C(for surface) 96001 For 400A AC; 10mV/A AC output 96095 For 130A AC/180A DC; 10mV/A AC/DC output TY700/TY500 series TY700/TY500 series All models except 73101 (with TY500 series upto 60A can be read directly) Current clamp probe Current Clamp Probe:TY700/TY500 series (Direct reading is possible for TY500 series) Name 96036 96033 96030 96031 96032 96034 96035 Current Clamp Probe *9V battery-operated. Can be AC adaptor-operated (optional) Measurable Conductor Diameter dia. 40mm Measurement Range 2A,AC dia. 18mm dia. 30mm dia. 65mm dia. 65 x 100mm 1000A, 2000A, 3000A, AC 500mV,AC dia. 170mm 200A,AC 500A,AC 500mV,AC 500mV,AC 700A,AC (1000A for 5 minutes) 250mV,AC 0.5% of rdg 0.5% of rdg 1.0% of rdg 1.0% of rdg 20Hz - 20kHz 20Hz - 5kHz 45Hz - 66Hz 30Hz - 1.5kHz 10Hz - 20kHz 600V,AC 600V,AC 600V,AC 600V,AC 1000V,AC (pri) 50A,AC Output Voltage 50mV,AC 500mV,AC Accuracy *varies according 0.5% of rdg 0.5% of rdg to input/Amplitude Frequency Range 20Hz - 5kHz 20Hz - 20kHz Maximum Circuit 50V,AC 300V,AC Voltage Note:Use AC voltage range of the DMM. Note:Need to covert the meter reading except TY500series. dia. 30mm 300 - 3000A,AC 500mV,AC 1.0% of rdg Basic Usage Digital Multimeters Voltage/Resistance Measurement Current Measurement Diode Test The COM terminal and V/ terminal are used. To measure a voltage, set the dial to voltage measurement. To measure a resistance, set the dial to resistance measurement. Some DMM models can also display the frequency and calculated decibel value at the same time when measuring an AC voltage. During resistance measurement, it is possible to switch the function to checking of the continuity of the measured circuit. The COM terminal, and A, A or mA terminal are used. Some models have shutters for preventing erroneous insertion into the current terminals and allow a contact of a lead to a current terminal only when the dial is set to current measurement. For these models, you cannot set the dial to voltage measurement while a lead is left inserted into a current terminal. This feature provides greater safety. A current flows through a diode when the power supply is connected as (1) below, while, almost no current flows when the power supply is connected as (2). The diode test function applies an adequate forward voltage across a diode to make a constant current flow and measures the voltage drop in the forward direction to determine the forward and reverse directions of the diode. Measuring a Voltage and Resistance Measuring a Current Measurement probe Checking the Polarity of a Diode Measurement probe Measurement probe A Load Current DC power supply AC power supply DC power supply AC power supply Current Load The circuit needs to be open for connection. 10 DC power supply (2) (1) K Anode Cathode NOTICE World Wide Web site at http://tmi.yokogawa.com YOKOGAWA METERS & INSTRUMENTS CORPORATION International Sales Dept. Tachihi Bld. No.2, 6-1-3 Sakaecho, Tachikawa-shi, Tokyo, 190-8586 Japan Phone: +81-42-534-1413 Facsimile: +81-42-534-1438 YOKOGAWA CORPORATION OF AMERICA 2 Dart Road, Newnan, GA. 30265-1094 U.S.A. Phone: +1-770-253-7000 Facsimile: +1-770-254-0928 YOKOGAWA EUROPE B. V. Euroweg 2 3825 HD Amersfoort, THE NETHERLANDS Phone: +31-88-4641000 Facsimile: +31-88-4641111 YOKOGAWA ENGINEERING ASIA PTE. LTD. 5 Bedok South Road, Singapore 469270 SINGAPORE Phone: +65-6241-9933 Facsimile: +65-6241-2606 YOKOGAWA AMERICA DO SUL LTDA. Praca Acapulco, 31-Santo Amaro, Sao Paulo/SP, BRAZIL CEP-04675-190 Phone: +55-11-5681-2400 Facsimile: +55-11-5681-4434 YOKOGAWA ELECTRIC KOREA CO., LTD. C&M Sales Seoul Office 1301-1305, 13rd floor, Kolon digital tower, 106-1, Yangpyongdong-5Ga, Yeongdeungpo-Gu, Seoul, 150-105, Korea Phone: +82-2-2628-3810 Facsimile: +82-2-2628-3899 Before using the product, read the instruction manual carefully to ensure proper and safe operation Represented by: YOKOGAWA AUSTRALIA PTY. LTD. Tower A/112-118 Talavera Road Macquarie Park, NSW 2113 Australia Phone: +61-2-8870-1100 Facsimile: +61-2-8870-1111 YOKOGAWA INDIA LTD. Plot No. 96. Electronic City Complex, Hosur Road, Bangalore 560100, INDIA Phone: +91-80-4158-6000 Facsimile: +91-80-2852-1441 YOKOGAWA SHANGHAI TRADING CO., LTD. 4F Tower D, Cartelo Crocodile Building, No.568 West Tianshan Road, Shanghai, CHINA Phone: +86-21-6239-6363 Facsimile: +86-21-6880-4987 YOKOGAWA MIDDLE EAST B. S. C.(C) P.O.BOX 10070, Manama, Building 577, Road 2516, Busaiteen 225, Muharraq, BAHRAIN Phone: +973-17-358100 Facsimile: +973-17-336100 YOKOGAWA ELECTRIC CIS LTD. Grokholskiy per. 13, Build. 2, 4th Floor, 129090, Moscow RUSSIAN FEDERATION Phone: +7-495-737-7868 Facsimile: +7-495-737-7869 Subject to change without notice. All Rights Reserved. Copyright (c) 2009, Yokogawa Meters & Instruments Corporation. [Ed: 12/b] MIK-EM18 Printed in Japan: sep. 2013(C)/ (KP)