12
1626A
1627A
Output Voltage 0-18V 0-18 V 0-60 V 0-60 V 0-30 V 0-30 V
Output Current 0-5A 0-5A 0-1.5 A 0-1.5 A 0-3 A 0-3 A
Constant Voltage
Operation
Voltage Regulation
Line (120VAC +10%, -6%) <0.02% + 3mV
Load (no load - full load) <0.02% + 3mV
Recovery Time <500ms
Ripple & Noise <1mVrms
Temperature Coefficient <300ppm/˚C
Constant Current Operation
Adjustable Current Range 0-100%
Current Regulation
Line (120VAC +10%, -6%) <0.02% + 3mA
Load <0.02% + 3mA
Current Ripple <3mA
Metering
Type Analog 3-digit LED Analog 3-digit LED Analog 3-digit LED
Voltmeter Range 0-18V 0-18V 0-60V 0-60V 0-30V 0-30V
Voltmeter Accuracy ±7% FS ±2% + 2 digits ±7% FS ±2% +2 digits ±7% FS ±2% +2 digits
Ammeter Range 0-5 A 0-9.99 A 0-3 A 0-9.99 A 0-3 A 0-9.99 A
Ammeter Accuracy ±7% FS ±2% +2 digits ±7% FS ±2% =2 digits ±7% FS ±2% +2 digits
Overload Protection Current, limiting, reverse polarity, overvoltage, short circuit
Power Requirements 120VAC ±10%, 60Hz (120/220/230/24CVAC ±10%, 50/60Hz version available)
Power Consumption 210W 220W 210W 220W 210W 220W
Operating Temperature 32° to 104°F (0˚ to 40˚C), <75% R.H.
Storage Temperature 5° to 158°F (-15° to +70°C), <85% R.H.
Dimensions (HxWxD) 8.07 x 4.53 x 10.63" (205 x 115 x 270 mm)
Weight 13.2 lbs. (6 kg) 16.3 lbs. (7.4 kg) 13.2 lbs. (6 kg) 16.3 lbs. (7.4 kg) 13.2 lbs. (6 kg) 16.3 lbs. (7.4 kg)
Specifications
■Connect two supplies in parallel to double the current
output
■Connect two supplies in series to double the voltage
output
■New compact style
■Reliable, Durable
■Operate continuously at full load without overheating
■Fully overload protected
■Coarse and fine voltage controls
■Great regulation
■Low ripple
■Constant voltage or constant current operation
■Continuously monitor voltage and current output on two
meters
One Year Warranty
OPTIONAL: Hook-up leads
up to 5 amps Model TL-5A
up to 30 amps Model TL-30
models
1620A 1621A 1622A 1623A 1626A 1627A