1627A 1626A Connect two supplies in parallel to double the current output Fully overload protected output New compact style Reliable, Durable Operate continuously at full load without overheating Low ripple Connect two supplies in series to double the voltage Coarse and fine voltage controls Great regulation Constant voltage or constant current operation Continuously monitor voltage and current output on two meters Specifications 1620A Output Voltage Output Current 0-18V 0-5A 1622A 1623A 1626A 0-18 V 0-5A 0-60 V 0-1.5 A 0-60 V 0-1.5 A 0-30 V 0-3 A 0-30 V 0-3 A 3-digit LED 0-60V 2% +2 digits 0-9.99 A 2% =2 digits Analog 0-30V 7% FS 0-3 A 7% FS 3-digit LED 0-30V 2% +2 digits 0-9.99 A 2% +2 digits 210W 220W 13.2 lbs. (6 kg) 16.3 lbs. (7.4 kg) Constant Voltage Operation Voltage Regulation Line (120VAC +10%, -6%) Load (no load - full load) Recovery Time Ripple & Noise Temperature Coefficient <0.02% + 3mV <0.02% + 3mV <500ms <1mVrms <300ppm/C Constant Current Operation Adjustable Current Range Current Regulation Line (120VAC +10%, -6%) Load Current Ripple Metering Type Voltmeter Range Voltmeter Accuracy Ammeter Range Ammeter Accuracy 0-100% <0.02% + 3mA <0.02% + 3mA <3mA Analog 0-18V 7% FS 0-5 A 7% FS 3-digit LED 0-18V 2% + 2 digits 0-9.99 A 2% +2 digits Analog 0-60V 7% FS 0-3 A 7% FS Overload Protection Current, limiting, reverse polarity, overvoltage, short circuit Power Requirements 120VAC 10%, 60Hz (120/220/230/24CVAC 10%, 50/60Hz version available) Power Consumption 210W 220W 210W Operating Temperature 5 to 158F (-15 to +70C), <85% R.H. Dimensions (HxWxD) 8.07 x 4.53 x 10.63" (205 x 115 x 270 mm) Accessories OPTIONAL: Hook-up leads up to 5 amps Model TL-5A up to 30 amps Model TL-30 12 220W 32 to 104F (0 to 40C), <75% R.H. Storage Temperature Weight models 1627A 1621A 13.2 lbs. (6 kg) 16.3 lbs. (7.4 kg) 13.2 lbs. (6 kg) 16.3 lbs. (7.4 kg) One Year Warranty