PRODUCT OVERVIEW Infinity STM Power System Compact, Dual Voltage, Rack Mounted Power System * Dual Voltage power system with ultimate flexibility Benefits Reliability * -48V up to 600A (32KW) or +24V up to 800A (22KW) - Distributed fault tolerance * Secondary voltage up to 120A - Controller continuity * High availability wireless telecom applications Intelligence * Telecom service providers - Ethernet interface for remote access * Efficiency approaching 97% - Proven field performance - Industry leading controller features - Centralized network management Investment Protection - Module Compatibility Overview The GE Infinity STM DC energy system is a compact power plant that supports dual voltage (+24V/-48V) operation through the use of a comprehensive range of advanced rectifiers and DC-DC converters. Primary voltage is supported by rectifiers and battery reserve, while secondary voltage is supported by DC-DC converter modules. Primary voltage can be -48V or +24V. The Infinity S Power System has primary voltage capacity for +24V and -48V power up to 800A; secondary voltage capacity is up to 120A per expansion module. Shelf / Bay Options Infinity S systems features mounting rails for field install applications and may be equipped in a 7 ft 23" relay rack; or a half height rack for mounting on battery stands. The distribution module is 4U tall and accommodates up to 26 single voltage or selectable voltage bullet breaker positions. Universal shelves are 1U tall with four slots that accept any Infinity series rectifier or converter interchangeably in any power slot. This allows the available slots to be filled with the mix of power modules desired. The only restriction is whether AC power 01/13 Infinity S Product Line Brochure is applied to the shelf. This gives extreme flexibility in the provisioning of power modules within the system. Infinity Rectifier and Converter Family The Infinity S offers DC rectifiers and converters for +24V to -48V applications. Rectifiers and converters are color coded to quickly identify both the voltage and whether it is a rectifier or converter (orange for +24V and blue for -48V). - Secondary Voltage flexibility +24V / -48V - Flexible Upgrade Options On Time Delivery - Standard building blocks - 4 - 6 week availability - 24/7 technical support Rectifier and Converter Options: Total Efficiency - NE100AC24ATEZ Rectifier, 100A/24V Output The GE Total EfficiencyTM (TE) architecture reduces energy loss and lowers cooling costs by 50-70%. TE products will prioritize sustainable energy sources like solar, wind, water and fuel cells over traditional utility grid or diesel generator sources - and they will intelligently respond to smart grid information to reduce consumption during peak demand periods. Active Rectifier Management (ARM) and Battery Charging Optimization (BCO) features increase efficiency on current and legacy power infrastructures. The Total Efficiency architecture addresses issues endto-end based on our proven experience and expertise in batteries, power distribution, DC energy systems, AC-DC power supplies, and DC-DC board mounted power to deliver a solution that is more safe, reliable and energy efficient than competitive alternatives. - NE050AC48ATEZ Rectifier, 50A/48V Output - NE075DC24 Converter, 75A/24V Output - NE030DC48 Converter, 30A/48V Output Pulsar Plus Controller The Infinity S utilizes the industry leading Pulsar Plus controller with Ethernet and SNMP communications to deliver extensive monitoring and control features with remote access. (c) 2013 General Electric Company. All rights reserved. TECHN I CAL SP ECI FI CATI ON S - P OW ER MODUL ES Infinity Rectifiers and Converters * Compact - 1RU form factor providing high power density (24 W/in3) * Dual Voltage compatibility - the unique connector pin designation allows the rectifier to be used in a "universal" power shelf, alongside rectifiers or DC-DC converters with different output voltages. * Plug and Play - installation of the rectifier in a shelf connected to a compatible system controller initializes all set up parameters automatically. No adjustments are needed. * Extended service life - parallel operation with automatic load sharing ensures that parallel units are not unduly stressed even when a unit fails or is removed. * Monitoring / control - the built in microprocessor controls and monitors all critical rectifier functions and communicates with the system controller using the built in Galaxy Protocol serial interface. * Fail safe performance - hot insertion capabilities allow for converter replacement without system shutdown; soft start and inrush current protection prevent nuisance tripping of upstream breakers. Applications * Telecommunications networks * Routers/switches * Data networks * Digital subscriber line (DSL) * Fiber in the loop * PBX * Indoor/outdoor wireless * Transmission Key Features * Extended temperature range * 1U height, hi power density * Hot pluggable * Redundant fan cooling * 220/110V AC input * RoHS compliant * Front panel LED indicators * Digital load sharing Specifications Input NE100AC24ATEZ NE050AC48ATEZ NE030DC48 NE075DC24 Voltage Range 95-275Vac 95-275Vac 21-30Vdc 42-60Vdc Input Current 15-12A @ 100-120Vac 15A @ 200-240Vac 15-12A @ 100-120Vac 15A @ 200-240Vac 63A @ 27Vdc 81A @ 21Vdc 41A @ 54.5Vdc 54a @ 42Vdc Input Frequency 45 - 66Hz 45 - 66Hz - - Power Factor 0.98 at>50% load 0.98 at>50% load - - Efficiency > 95% (Peak 95.6%) > 96% (Peak 96.9%) - - Total Harmonic Distortion <5% @loads over 50% <5% @loads over 50% - - Voltage Adjust Range 21-29Vdc 42-58Vdc 46-57Vdc 23-28Vdc Voltage Nominal 27.25V 54.5V 52.0V 27.2V Regulation (with controller) 0.5% 0.5% 0.5% 0.5% Ripple 100mVrms 100mVrms 100mVrms 100mVrms Output Current - High-Line - Low-Line 100A @27.25V 44A @27.25V 50A @54.5V 22A @54.5V 30A @52.0V - 75A @27.2V - Heat Dissipation @ max out 174W / 594 BTU/hr 158W / 539 BTU/hr 154W / 525 BTU/hr 202W / 689 BTU/hr Output Page 2 01/13 Infinity S Product Line Brochure (c) 2013 General Electric Company. All rights reserved. TECHN I CAL SP ECI FI CATI ON S - P OW ER MODUL ES Environmental Operating Temperature -40C to +75C (-40 to 167F) Storage Temperature -40C to +85C (-40 to 185F) Humidity < 95% non-condensing Altitude 4000M (for altitudes above 2000M, peak operating temperature de-rates 0.656 C /100M; 4000M peak temperature rating is 62 C Mechanical Length (inch/mm) 13.85 / 351.8 Width (inch/mm) 5.23 / 133 Height (inch/mm) 1.63 / 42 Weight (lb/Kg) 5.05 / 2.2 Safety and Standards Compliance NEBs Level 3 Evaluated by independent NRTL test lab to Telcordia GR63, Issue 3 & GR 1089, Issue 5 Safety CE mark to Low Voltage Directive 2006/95/EC and EMC Directive 2004/108/E (Rectifiers only) UL 60950-1, 2nd Ed. Recognized CSA C22.2 No. 60950-1-03 Certified RoHS Compliant to RoHS EU Directive 2002/95/EC; RoHS 6/6 EMC European Directive 2004/108/EC; EN55022, Class A; EN55024; FCC, Class A; GR1089-CORE, Issue 5 ESD EN61000-4-2, Level 4 Outline Drawing Page 3 01/13 Infinity S Product Line Brochure (c) 2013 General Electric Company. All rights reserved. TECHN I CAL SP ECI FI CATI ON S - CON TR OL L ER Pulsar Plus Controller The Pulsar Plus family of controllers provides system monitoring and control features for Infinity, CP, and other power systems. These controllers monitor and control system components including rectifiers, converters, and distribution modules via a multi-drop RS485 digital communications bus. System status, parameters, settings, and alarm thresholds can be viewed and configured from the controller's front panel display. Assignment and configuration of alarm inputs and output relays can be performed from a laptop computer connected to a local RS-232 or Ethernet port, or by remote access is through a network connection to the World Wide Web (internet) or your enterprise network (intranet). An optional modem is also available. * Telecommunications networks * Routers/switches * Data networks * Digital subscriber line (DSL) * Fiber in the loop * PBX * Indoor/outdoor wireless * Transmission This controller utilizes standard network management protocols allowing for advanced network supervision. The GE Galaxy ManagerTM software is the centralized visibility and control component of a comprehensive power management system designed to meet engineering, operations and maintenance needs. The Galaxy Manager client-server architecture enables remote access to system controllers across the power network. Applications Key Features Remote Access and Features Standard System Features Standard Battery Management Features * Integrated 10/100Base-T Ethernet Network - TCP/IP - SNMP V2c for management - SMTP for email - Telnet for command line interface - DHCP for plug-n-play - FTP for rapid backup and upgrades - HTTP for standard web pages and browsers - Compatible with Galaxy Manager and other management packages - Shielded RJ-45 interface referenced to chassis ground * Password protected security levels: User, Super-User, Administrator for all access * Ground-referenced RS232 system port * ANSI T1.317 command-line interface * Modem access support - Remote via external modem - Callback security * EasyView2, Windows-based GUI software for local terminal or Modem access * Monitor and control of more than 40 connected devices - Robust RS485 system bus * Standard and user defined alarms - Alarm test - Assignable alarm severity: Critical, Major, Minor, Warning, and record-only - 10 alarm relays (7 user assigned) * Rectifier management features - Automatic rectifier restart - Active Rectifier Management ARM (energy efficiency) - Remote rectifier (on/off) - Reserve Operation - Automatic rectifier sequence control - N + X redundancy check * Multiple Low Voltage Load and Low Voltage Battery Disconnect thresholds * Configuration, statistics, and history - All stored in non-volatile memory - Remote/local backup and restore of configuration data * Industry standard defaults - Customer specific configurations available * Remote/ local software upgrade * Basic, busy hour, and trend statistics * Detailed event history * User defined events and derived channels * Float/boost mode control - Manual boost - Manual timed boost locally, T1.317, and remotely initiated - Auto boost terminated by time or current * Battery discharge testing - Manual (local/remote) - Periodic - Plant Battery Test (PBT) input driven - Configurable threshold or 20% algorithm - Graphical discharge data - Rectifiers on-line during test * Slope thermal compensation - High temperature - Low temperature - Step temperature - STC Enable/Disable, low temperature Enable/Disable - Configurable mV/C slopes * State of charge indication * High temperature disconnect setting * Reserve-time prediction * Recharge current limit * Emergency Power-Off input Page 4 01/13 Infinity S Product Line Brochure (c) 2013 General Electric Company. All rights reserved. TECHN I CAL SP ECI FI CATI ON S - CON TR OL L ER Integrated Monitoring Inputs/Outputs Galaxy Manager Compatible * System plant voltage (accuracy 0.5%, resolution 0.01V) * Centralized web server and database with multiple user access to live or managed data with drill down to problem details * One system shunt (accuracy 0.5% full scale, resolution 1A) - Battery or load - Mounted in the return side of DC bus * Up to 15 binary inputs - Six inputs close/open to battery - 9 input close/open to return - User assignable * Monitor and control of more than 40 connected devices * Management information from polling or alarms received from alarm traps from multiple sites are available on one screen via the inter/ intranet * Trend user selected data over time * Automatic or manual report generation * Up to 7 Form-C output alarms (60VDC @ .5A) - User assignable * Standard engineering tools like reserve time calculators and cable voltage drop analyzer * 1-WireTM bus devices - Up to 16 temperature probes (QS873) - Up to 6 mid-string monitors (ES771) Safety and Standards Compliance General Operating Voltage 24 Vdc, 48 Vdc (Range: 18 to 60 Vdc) NEBs Evaluated by independent NRTL test lab to Telcordia GR63, Issue 3 and GR1089-CORE, Issue 5 Input Power Less than 7W Safety Operating Temperature Range -40C to +75C (-40F to 167F) CSA C22.2 No. 60950-1-03 Certified for Canada and U.S.; UL60950-1 1st Ed. Operating Relative Humidity 0 - 95% (non-condensing) RoHS Compliant to RoHS EU Directive 2002/95/EC RoHS 5/6 Storage Temperature Range -40C to +85C (-40F to 185F) EMC Physical Specifications Sizes vary by packaging option European Directive 2004/108/EC; EN55022, Class A, EN55024; FCC, Class A; GR1089-CORE, Issue 5 Display 8-line by 40-character with alarm context sensitive backlit LCD Agency Certifications NEBs Level 3 Evaluated by independent NRTL test lab to Telcordia GR63, Issue 3 and GR1089-CORE, Issue 5 EMC European Directive 2004/108/EC; EN55022, (CISPR22) Class A, EN55024 (CISPR24) Safety Underwriters Laboratories (UL) Listed per Subject Letter 1801: Power Distribution Center for Communications Equipment, and cUL Certified (CSA 22.2 950): Safety of Information Technology Equipment Page 5 01/13 Infinity S Product Line Brochure (c) 2013 General Electric Company. All rights reserved. TECHN I CAL SPECI FI CATI ON S - SY S T EM Infinity S System Infinity S may be configured as a +24V or -48V single voltage power system or as a dual voltage power system that supports rectifiers and converters. The primary voltage is supported by +24V or -48V rectifiers and battery reserve, while secondary voltage is supported by DC-DC converters. Infinity-S includes dedicated 24V, 48V and return buses. The primary voltage capacity is 800A at 24V and 600A at 48V. Secondary (-48V) voltage capacity is up to 120A. The system includes low voltage battery disconnect option for the primary voltage. A low voltage load disconnect option can be used for load shedding to maintain critical loads. Applications * Wireless Telecom networks * Transmission * Indoor/outdoor wireless * Data networks * ECO Priority Source Key Features * Dual Voltage Flexibility * 1U height, hi power density * Hot pluggable * Redundant fan cooling * 220/110 V AC input * RoHS compliant * Front panel LED indicators * Digital load sharing Specifications Input Voltage Range - High-Line - Low-Line Min Typ Max 175Vac 85Vac 220Vac 110Vac 275Vac 140Vac 66Hz Frequency 45Hz 60Hz Power Factor 98% 99.5% Total Harmonic Distortion Only available in 24V Rectifiers 5% Primary Output Nominal Voltage 24Vdc Output Current 1,200A 800A 27.2Vdc1% -54.5Vdc1% Vo Setpoint (factory) Vo Range -48Vdc +21Vdc to +29Vdc Regulation -42Vdc to -58Vdc 0.5% Secondary Output Nominal Voltage -48Vdc Output Current Vo Setpoint (factory) Vo Range +24Vdc 120A 300A -54.5Vdc1% 27.25Vdc1% -42Vdc to -58Vdc +21Vdc to +29Vdc Regulation 0.5% Mechanical System Only Frame Mounted System Height (in. /mm) 21.25 / 540 (Base system with 4 power shelves and 2 distributions) 84 / 2134 Width (in. /mm) 23 / 584.2 26 / 660.4 Depth (in. /mm) 21 / 533 21 / 533 Weight (lb / Kg) 108 / 49 (Base system with 4 power shelves and 2 distributions) 292 / 132 Page 6 01/13 Infinity S Product Line Brochure (c) 2013 General Electric Company. All rights reserved. TECHN I CAL SPECI FI CATI ON S - SY S T EM Environmental Operating Temperature -40C to +75C (-40F to 167 F) Storage Temperature -40C to +85C (-40F to 185 F) Relative Humidity 95% max, non-condensing Altitude 4000M (for altitudes above 2000M, peak operating temperature de-rates 0.656 C /100M; 4000M peak temperature rating is 62 C Safety and Standards Compliance NEBs Evaluated by independent NRTL test lab to Telcordia GR63, Issue 3 and GR1089-CORE, Issue 5 Safety CSA C22.2 No. 60950-1-03 Certified for Canada and U.S.; UL60950-1 1st Ed. RoHS Compliant to RoHS EU Directive 2002/95/EC RoHS 5/6 EMC European Directive 2004/108/EC; EN55022, Class A; EN55024; FCC, Class A; GR1089-CORE, Issue 5 Agency Certifications CSA CSA C22.2 No 60950-1-03 and UL 60950-1 1st Ed EMI/EMC European Directive 2004/108/EC; EN55022 (CISPR22) Class A; EN55024 (CISPR24) NEBS LEVEL 3 GR1089-CORE, Issue 5 Outline Drawing Page 7 01/13 Infinity S Product Line Brochure (c) 2013 General Electric Company. All rights reserved. ORDERING INFORMATION - INFINIT Y S P OWER SYSTEM Ordering Information - Infinity S Power System Ordering Guide Infinity S may be configured as a +24V or -48V single voltage power system or as a "dual voltage" power system that supports rectifiers and converters. The primary voltage is supported by +24V or -48V rectifiers and battery reserve, while secondary voltage is supported by DC-DC converters. The primary voltage capacity is 800A at 24V and 600A at 48V. Secondary voltage capacity is up to 120A. Infinity S systems may be equipped in a 7ft framework, a half height (42") frame for mounting on battery stands, or supplied frameless for field install applications. Features * Infinity Series Rectifiers for +24V and -48V applications. * Dual Voltage Bus architecture for easy growth and voltage migration * DC-DC Converter support for dual voltage systems * DC Distribution for both voltages, with Selectable Voltage panel availability * Temperature hardened harsh environments. (-40C to +75C) * Compact size: Base System with 1 power shelf occupies 5 RU (8.75 in) of 23" rack space (18" depth) * Frame options - Factory installed in 7ft or 42" tall, 23" wide frame or field installed in user supplied frame * Battery connections, LVBD and LVLD options. * Plug-N-Play Pulsar Plus controller with Web based interface for local and remote (LAN) access. * Distribution options include 3A-250A bullet style circuit breakers, and GMT fuses Page 8 01/13 Infinity S Product Line Brochure (c) 2013 General Electric Company. All rights reserved. ORDERING INFORMATION - INFINIT Y S P OWER SYSTEM AC Input Types Type Description AC1 Dual Feed, Molex Mini-fit Sr Schematic 23" Shelves AC3 Individual Feed, IEC-320 C19 Receptacles AC5 Individual Feed, Terminal Strip Rear cover is equipped with a 1" conduit knockout Page 9 01/13 Infinity S Product Line Brochure (c) 2013 General Electric Company. All rights reserved. ORDERING INFORMATION - INFINIT Y S P OWER SYSTEM DC Output Types -48V Single Voltage Type Description DC1E Single External Bullet Breaker Distribution Panel 26 Positions for 23" configuration Ratings: 600A output (600A discharge), 250A max breaker (65C Ambient) Schematic DC2E Dual External Bullet Breaker Distribution Panel 52 Positions for 23" configuration Ratings: 600A output (800A discharge), 250A max breaker (65C Ambient) Page 10 01/13 Infinity S Product Line Brochure (c) 2013 General Electric Company. All rights reserved. DC Output Types For Dual Voltage Systems Type Description DC1E Single External Dual Voltage Bullet Breaker Distribution Panel 26 Positions for 23" configuration Ratings: 800A primary voltage output (800A discharge) and up to 300A secondary voltage output, 250A max breaker (65C Ambient) Schematic DC2E Dual External Dual Voltage Bullet Breaker Distribution Panel 52 Positions for 23" configuration Ratings: 800A primary voltage output (800A discharge) and up to 300A secondary voltage output, 250A max breaker (65C Ambient) Page 11 01/13 Infinity S Product Line Brochure (c) 2013 General Electric Company. All rights reserved. ORDERING INFORMATION - INFINIT Y S P OWER SYSTEM Step 1: Select the Base Power System Single Voltage System -48V Output Rating Description 200A 200A Infinity S Power system equipped with 4 rectifier positions and 26 distribution positions selectable between -48V Load and Battery 400A 600A 600A 600A 800A 400A Infinity S Power system equipped with 8 rectifier positions and 26 distribution positions selectable between -48V Load and Battery 600A Infinity S Power system equipped with 12 rectifier positions and 26 distribution positions selectable between -48V Load and Battery 600A Infinity S Power system equipped with 12 rectifier positions and 52 total distribution positions, 26 of which selectable between -48V Load and Battery 600A Infinity S Power system equipped with 16 rectifier positions and 26 distribution positions selectable between -48V Load and Battery 800A Infinity S Power system equipped with 4 rectifier positions and 52 total distribution positions, 26 of which selectable between -48V Load and Battery Ordering Code Model No CC109163696 NES48 -23 -AC1 -PS4 -DC1E No CC109163663 NES48 -23 -AC3 -PS4 -DC1E Ind. Term Block No 150029007 NES48 -23 -AC5 -PS4 -DC1E Dual Molex LVBD CC109160438 NES48 -23 -AC1 -PS4 -DC1E -LVBD Individual C19 LVBD CC109167904 NES48 -23 -AC3 -PS4 -DC1E -LVBD Ind. Term Block LVBD 150029001 NES48 -23 -AC5 -PS4 -DC1E -LVBD Dual Molex No CC109163705 NES48 -23 -AC1 -PS8 -DC1E Individual C19 No CC109163671 NES48 -23 -AC3 -PS8 -DC1E Ind. Term Block No 150029008 NES48 -23 -AC5 -PS8 -DC1E Dual Molex LVBD CC109165998 NES48 -23 -AC1 -PS8 -DC1E -LVBD Individual C19 LVBD CC109165981 NES48 -23 -AC3 -PS8 -DC1E -LVBD Ind. Term Block LVBD 150029002 NES48 -23 -AC5 -PS8 -DC1E -LVBD Dual Molex No CC109163713 NES48 -23 -AC1 -PS12 -DC1E Individual C19 No CC109163688 NES48 -23 -AC3 -PS12 -DC1E Ind. Term Block No 150029009 NES48 -23 -AC5 -PS12 -DC1E Dual Molex LVBD CC109167920 NES48 -23 -AC1 -PS12 -DC1E -LVBD Individual C19 LVBD CC109167912 NES48 -23 -AC3 -PS12 -DC1E -LVBD Ind. Term Block LVBD 150029003 NES48 -23 -AC5 -PS12 -DC1E -LVBD Dual Molex No CC109171286 NES48 -23 -AC1 -PS12 -DC2E Individual C19 No CC109171261 NES48 -23 -AC3 -PS12 -DC2E Ind. Term Block No 150029011 NES48 -23 -AC5 -PS12 -DC2E Dual Molex LVBD CC109171278 NES48 -23 -AC1 -PS12 -DC2E -LVBD Individual C19 LVBD CC109171253 NES48 -23 -AC3 -PS12 -DC2E -LVBD Ind. Term Block LVBD 150029006 NES48 -23 -AC5 -PS12 -DC2E -LVBD Ind. Term Block No 150029010 NES48 -23 -AC5 -PS16 -DC1E Ind. Term Block LVBD 150029004 NES48 -23 -AC5 -PS16 -DC1E -LVBD Ind. Term Block No 150029012 NES48 -23 -AC5 -PS16 -DC2E Ind. Term Block LVBD 150029006 NES48 -23 -AC5 -PS16 -DC2E -LVBD AC Input LVD Dual Molex Individual C19 Frame Photo Page 12 01/13 Infinity S Product Line Brochure (c) 2013 General Electric Company. All rights reserved. ORDERING INFORMATION - INFINIT Y S P OWER SYSTEM Step 1: Select the Base Power System (cont.) Dual Voltage Infinity S Power Systems, -48V Primary with +24V Secondary Ordering Code Model No 150022649 NES4824-23-AC1-PS8-DC1E Individual C19 No 150022653 NES4824-23-AC3-PS8-DC1E Dual Molex LVBD 150022648 NES4824-23-AC1-PS8-DC1E-LVBD Individual C19 LVBD 150022652 NES4824-23-AC3-PS8-DC1E-LVBD Dual Molex LVBD 150024038 NES4824-23-AC1-PS8-DC2E-LVBD Individual C19 LVBD 150024039 NES4824-23-AC3-PS8-DC2E-LVBD Dual Molex No 150022651 NES4824-23-AC1-PS16-DC1E Individual C19 No 150022655 NES4824-23-AC3-PS16-DC1E Dual Molex LVBD 150022650 NES4824-23-AC1-PS16-DC1E-LVBD Individual C19 LVBD 150022654 NES4824-23-AC3-PS16-DC1E-LVBD Dual Molex No CC109172508 NES4824-23-AC1-PS16-DC2E Individual C19 No 150022657 NES4824-23-AC3-PS16-DC2E Ind. Term Block No 150027199 NES4824-23-AC5-PS16-DC2E Dual Molex LVBD CC109170643 NES4824-23-AC1-PS16-DC2E-LVBD Individual C19 LVBD 150022656 NES4824-23-AC3-PS16-DC2E-LVBD Ind. Term Block No 150027200 NES4824-23-AC5-PS16-DC2E-7FTR Output Rating Description AC Input LVD Dual Molex 400A 400A Infinity S Power system equipped with 8 universal positions and 26 distribution positions selectable between -48V Load and +24V Converter load 400A 800A 800A 400A Infinity S Power system equipped with 8 universal positions and 52 total distribution positions, 26 dedicated to -48V and 26 of which selectable between -48V Load and 24V Converter Load 800A Infinity S Power system equipped with 16 universal positions and 26 distribution positions selectable between -48V Load and +24V Converter load 800A Infinity S Power system equipped with 16 universal positions and 52 total distribution positions, 26 dedicated to -48V and 26 of which selectable between -48V Load and 24V Converter Load Frame 84" Zone 4 Photo Page 13 01/13 Infinity S Product Line Brochure (c) 2013 General Electric Company. All rights reserved. ORDERING INFORMATION - INFINIT Y S P OWER SYSTEM Step 1: Select the Base Power System (cont.) Dual Voltage Infinity S Power Systems, +24V Primary with -48V Secondary Ordering Code Model No CC109172524 NES2448-23-AC1-PS8-DC1E Individual C19 No 150022660 NES2448-23-AC3-PS8-DC1E Dual Molex LVBD CC109172516 NES2448-23-AC1-PS8-DC1E-LVBD Individual C19 LVBD 150022659 NES2448-23-AC3-PS8-DC1E-LVBD Dual Molex No CC109163135 NES2448-23-AC1-PS16-DC1E Individual C19 No 150022662 NES2448-23-AC3-PS16-DC1E Dual Molex LVBD CC109160818 NES2448-23-AC1-PS16-DC1E-LVBD Individual C19 LVBD 150022661 NES2448-23-AC3-PS16-DC1E-LVBD Dual Molex No CC109172540 NES2448-23-AC1-PS16-DC2E Individual C19 No 150022664 NES2448-23-AC3-PS16-DC2E Ind. Term Block No 150027197 NES2448-23-AC5-PS16-DC2E Dual Molex LVBD CC109172532 NES2448-23-AC1-PS16-DC2E-LVBD Individual C19 LVBD 150022663 NES2448-23-AC3-PS16-DC2E-LVBD Ind. Term Block No 150027198 NES2448-23-AC5-PS16-DC2E-7FTR Output Rating Description AC Input LVD Dual Molex 800A 800A Infinity S Power system equipped with 8 universal positions and 26 distribution positions selectable between +24V Load and -48V Converter load 1000A Infinity S Power system equipped with 16 universal positions and 26 distribution positions selectable between+24V Load and -48V Converter load 1000A 1000A 1000A Infinity S Power system equipped with 16 universal positions and 52 total distribution positions, 26 dedicated to +24V and 26 of which selectable between +24V Load and -48V Converter Load Frame 84" Zone 4 Photo Page 14 01/13 Infinity S Product Line Brochure (c) 2013 General Electric Company. All rights reserved. ORDERING INFORMATION - INFINIT Y S P OWER SYSTEM Step 2: Select Rectifiers and Converters Rectifiers Ordering Code Model CC109160834 95 - 145Vac input, 24V, 44A Output, 175 - 275Vac input, 24V, 100A output; 145 - 175 linear output increase from 44A to 100A 100A Photo NE100AC24ATEZ 150027075 100A 95 - 145Vac input, 24V, 44A Output, 175 - 275Vac input, 24V, 100A output; 145 - 175 linear output increase from 44A to 100A 100 - 310 VDC input from Solar resource with full power above 250VDC. NE100ECO24ATEZ CC109158878 50A 95 - 145Vac input, 48V, 22A Output, 175 - 275Vac input, 48V, 50A output; 145 - 175 linear output increase from 22A to 50A NE050AC48ATEZ 150027074 50A 95 - 145Vac input, 48V, 22A Output, 175 - 275Vac input, 48V, 50A output; 145 - 175 linear output increase from 22A to 50A 100 - 310 VDC input from Solar resource with full power above 250VDC. NE050ECO48ATEZ Converters Ordering Code Model CC109112471 21-29 Vdc input, 48V, 30A output 30A NE030DC48 CC109142881 75A Photo 42-58 Vdc input, 24V, 75A output NE075DC24 Page 15 01/13 Infinity S Product Line Brochure (c) 2013 General Electric Company. All rights reserved. ORDERING INFORMATION - INFINIT Y S P OWER SYSTEM Step 3: Select AC Cord Example: 208/240VAC for a NES48-AC1-PS4-DC1E-LVBD shelf using 50A rectifiers would use a 848710711 AC 8 gauge which provides 2 AC cords; enough to power 4 rectifiers. Customer should provide one 40A protecting circuit breaker per two rectifiers. For AC3 cable sets, it is recommended that a 20A circuit breaker is used per rectifier. Note: If PS# of your shelf model number is not listed in table, choose the next higher number. AC cords are 10 feet long and unterminated on the end. See optional accessories for twist lock connectors. Ordering Code AC Type Gauge Shelf Termination Order # of Cords Shelf Dual Indiv. Cord Type Length User Termination 120 Vac 208/240 Vac x x x CC848801977 Molex 1 x Sleeved 3' Unterminated CC848830522 Molex 1 x Sleeved 4' Unterminated Molex 1 x Sleeved 10' Unterminated Molex 2 x SO 10' Unterminated x 848710711 AC1 8 CC848906586 CC848773515 10 Molex 2 SO 15' Unterminated CC848847368 12 IEC - No Plug 4 x SO 8' Unterminated x CC848850792 12 IEC 5-15P 4 x SO 8' 5-15P x 12 IEC 5-20P 4 x SO 8' 5-20P x 12 IEC 6-15P 4 x SO 8' 6-15P x CC848850801 CC848850826 AC3 CC848850834 12 IEC 6-20P 4 x SO 8' 6-20P x CC848850842 12 IEC L6-20P 4 x SO 8' L6-20P x CC848850850 12 IEC L6-30P 4 x SO 8' L6-30P X Step 4: Select Alarm Cables Alarm Cables Ordering Code Model CC848865980 15ft Auxiliary input alarm cable for Pulsar Plus Controller Photo CC848817651 50ft Auxiliary input alarm cable for Pulsar Plus Controller CC848817668 150ft Auxiliary input alarm cable for Pulsar Plus Controller CC109157442 15ft alarm cable for Pulsar Plus Controller CC848817635 50ft alarm cable for Pulsar Plus Controller CC848817643 150ft alarm cable for Pulsar Plus Controller Page 16 01/13 Infinity S Product Line Brochure (c) 2013 General Electric Company. All rights reserved. ORDERING INFORMATION - INFINIT Y S P OWER SYSTEM Step 5: Select Distribution Components Note: Infinity S systems all support plug-in (bullet style) breakers or fuse modules. Larger breakers can be 2 or even 3 poles. The multi-pole breakers MUST be used with the appropriate multi-pole adapter to parallel the poles for proper operation. Bullet Style Load Circuit Breakers Ordering Code Amperage CB Positions (Poles) Min Wire Gauge 407998137 3 1 10 407998145 5 1 10 407998152 10 1 10 407998160 15 1 10 407998178 16 1 10 407998186 20 1 10 407998194 25 1 10 407998202 30 1 10 408213486 40 1 8 407998210 45 1 8 407998228 50 1 6 407998236 60 1 6 407998244 70 1 2 407998251 80 1 2 407998269 90 1 2 407998277 100 1 2 CC848808551 100 2 2 408185353 125 2 2 408185346 150 2 1/0 408564941 200 3 2/0 408573975 225 3 4/0 408535752 250 3 4/0 CC848756916 2-pole Adapter bus for 100-150A breakers (order 2 per 2 pole breaker to accommodate load and return lugs) 850021775 2-pole Adapter bus for 100-150A breakers; used for 3/8" on 1" lugs (order 2 per 2 pole breaker to accommodate load and return lugs) CC848756924 3-pole Adapter bus for 200-250A breakers (order 2 per 3 pole breaker to accommodate load and return lugs) 850021955 3-pole Adapter bus for 200-250A breakers; centered connection (order 2 per 3 pole breaker to accommodate load and return lugs) Photo Page 17 01/13 Infinity S Product Line Brochure (c) 2013 General Electric Company. All rights reserved. ORDERING INFORMATION - INFINIT Y S P OWER SYSTEM Step 5: Select Distribution Components (cont.) Bullet Battery Circuit Breakers (Yellow Handle) (Alarms on Mid-trip and in Off position) Ordering Code Amperage Ordering Code Amperage CC408612758 30 CC408574387 70 CC408612766 40 CC408574395 100 (2-pole) CC408612774 45 CC408574404 125 (2-pole) CC408574370 50 CC408574412 150 (2-pole) 408560123 60 CC408574420 200 (2-pole) CC109106548 100A battery bullet bus strap (substitute for battery breaker) Photo Bullet Style Fuse Holder and TPS Fuses Ordering Code Amperage WP-92461 List Min Wire Gauge 406700567 3 100 10 406700583 5 101 10 406700591 6 102 10 406700609 10 103 10 406700617 15 104 10 406700625 20 105 10 406700633 25 106 10 406700641 30 107 10 406700658 40 108 10 406700674 50 109 8 406700682 60 110 6 406700690 70 111 6 402328926 0.18 Alarm Fuse 408548944 Bullet Fuse Holder, TFD-101-011-09 (Alarms on Blown Fuse or Fuse Head Removal) CC408617410 Bullet Fuse Holder, TFD-101-011-10 (Alarms on Blown Fuse Only) Photo Page 18 01/13 Infinity S Product Line Brochure (c) 2013 General Electric Company. All rights reserved. ORDERING INFORMATION - INFINIT Y S P OWER SYSTEM Step 5: Select Distribution Components (cont.) Bullet Style GMT Fuse Holder and GMT Fuses Ordering Code Amperage WP-92461 List Min Wire Gauge 405006222 0.25A 3150439 0.5A 405673146 1.33A 405181983 2A 406976985 3A 406159061 5A 405725433 7.5A 406159236 10A 407845197 12A 406473959 15A CC109103157 6-pos GMT Bullet Fuse Holder (Requires 2 bullet postions) 408515823 Fuse Puller 402099436 Dummy Fuse Photo Terminal Lugs for Bullet Style Breakers and TPS Fuses (1/4" bolt on 5/8" centers) Ordering Code STR Wire GA (Class B) Flex Wire GA (Class I) WP-91412 List 406021626 8 8 75 405347519 6 6 3 405347576 4 4 5 405348202 2 - 54 405347683 - 2 8 Photo Terminal Lugs for Battery and Large Breakers (3/8" bolt on 1" centers) 406338665 2 - - 405348228 1/0 - - 405348236 2/0 1/0 - 406021725 - 2/0 - 405348251 4/0 - - 405347923 - 4/0 - Page 19 01/13 Infinity S Product Line Brochure (c) 2013 General Electric Company. All rights reserved. ORDERING INFORMATION - INFINIT Y S P OWER SYSTEM Step 6: Select Battery Monitoring Ordering Code Description CC109142980 QS873A Thermal Probe (A) Photo CC848817024 10 ft wire set CC109157434 20 ft wire set (B:thermal probe to controller) CC848822560 1 ft wire set (C: thermal probe to thermal probe) 848719803 5 ft wire set (C: thermal probe to thermal probe) CC848822321 10 ft wire set (C: thermal probe to thermal probe) 850027334 20 ft wire set (C: thermal probe to thermal probe) 108958422 ES771A Battery Voltage Monitor Card CC848791517 2-1/2 ft wire set CC848797290 6 ft wire set (D: ES771A to thermal probe) 848719829 10 ft wire set (D: ES771A to thermal probe) CC848791500 4 ft wire set (G: ES771A to ES771A or controller) 848652947 10 ft wire set (G: ES771A to ES771A or controller) 555052-1 In-Line Coupler (for extending item G above) (B: thermal probe to controller) (D: ES771A to thermal probe) Temperature/Voltage probes are needed for battery monitoring. They are connected to each battery or battery string to provide slope thermal compensation, temperature alarms and voltage imbalance alarms. Temperature Measurement Temperature and Voltage Measurement Page 20 01/13 Infinity S Product Line Brochure (c) 2013 General Electric Company. All rights reserved. ORDERING INFORMATION - INFINIT Y S P OWER SYSTEM Shelf Specifications Mechanical Height 4RU main cabinet plus 1RU per power shelf - Base system 5RU (8.75 inches / 222mm) Width (with mounting ears) 23 inches (584mm) Depth 18 inches (457mm), 21 inches (533mm) for systems equipped with AC5 input Weight (without rectifiers) Approximately 42lbs (19kg) - Base system with 1 rectifier shelf Environmental NEBs Evaluated by independent NRTL test lab to Telcordia GR63, Issue 3 and GR1089-CORE, Issue 5 Safety CSA C22.2 No. 60950-1-03 Certified for Canada and U.S.; UL60950-1 1st Ed. RoHS Compliant to RoHS EU Directive 2002/95/EC RoHS 5/6 EMC European Directive 2004/108/EC; EN55022, Class A; EN55024; FCC, Class A; GR1089-CORE, Issue 5 Agency Certifications UL CSA C22.2 No 60950-1-03 and UL 60950-1 1st Ed EMI/EMC European Directive 2004/108/EC; EN55022 (CISPR22) Class A; EN55024 (CISPR24) NEBS LEVEL 3 GR1089-CORE, Issue 5 Additional Information Product Documentation H5692448: Ordering Guide. A copy of the appropriate installation manuals below ship with each system. CC848815325: H5692448 Installation Guide CC848815341: Advanced Features User Guide for the Pulsar Plus Controller, 167-792-183 Page 21 01/13 Infinity S Product Line Brochure (c) 2013 General Electric Company. All rights reserved. ORDERING INFORMATION - INFINIT Y S P OWER SYSTEM Management Visibility Service & Support Galaxy ManagerTM software is the centralized visibility and control component of a comprehensive power management system designed to meet engineering, operations and maintenance needs. The Galaxy Manager client-server architecture enables remote access to system controllers across the power network. GE field service and support personnel are trusted advisors to our customers - always available to answer questions and help with any project, large or small. Our certified professional services team consists of experts in every aspect of power conversion with the resources and experience to handle large turnkey projects along with custom approaches to complex challenges. Proven systems engineering and installation best practices are designed to safely deliver results that exceed our customers' expectations. * Dashboard display with one-click access to management information database * Trend analysis Warranty * Scheduled or on demand reports * Fault, configuration, asset, and performance management Training GE offers on-site and classroom training options based on certification curriculum. Technical training can be tailored to individual customer needs. Training enables customers and partners to more effectively manage and support the power infrastructure. We have built our training program on practical learning objectives that are relevant to specific technologies or infrastructure design objectives. GE is committed to providing quality products and solutions. We have developed a comprehensive warranty that protects you and provides a simple way to get your products repaired or replaced as soon as possible. For full warranty terms and conditions please go to www.ge.com/powerelectronics. Contact Us For more information, call us toll free at +1 877 546 3243, or +1 972 244 9288 and visit us on the web at www.ge.com/powerelectronics 01/13 Infinity S Product Line Brochure (c) 2013 General Electric Company. All rights reserved. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: GE (General Electric): 848710711