Solid State Relay G3TB I/O SSR Used as Interface between Logic Circuitry and Load * A variety of AC/DC input and output modules classified by color. * Operation can be monitored easily through an LED indicator. * Dielectric strength of 4,000 V between input and output terminals. * Certified by UL and CSA. Ordering Information Input Modules Isolation Indicator Logic level Supply voltage Photocoupler Yes 4 to 32 VDC Supply current 25 mA Rated input voltage Model 100 to 240 VAC G3TB-IAZR02P-US 4 to 24 VDC G3TB-IDZR02P-US Output Modules Isolation Photocoupler Zero cross function Yes Indicator Yes --- Model 5 to 24 VDC G3TB-OA203PZ-US G3TB-OA203PZM-US Yes 5 to 24 VDC G3TB-OA203PL-US No 4 to 24 VDC G3TB-OA203PLM-US 5 to 24 VDC G3TB-ODX03P-US 4 to 24 VDC G3TB-ODX03PM-US Yes No Yes No 3 A at 100 to 240 VAC (3 A at 75 to 264 VAC) Rated input voltage 4 to 24 VDC No No Rated output voltage (Applicable output load) 3 A at 5 to 48 VDC (3 A at 4 to 60 VAC) 1.5 A at 48 to 200 VDC 5 to 24 VDC (1.5 A at 40 to 200 VDC) 4 to 24 VDC G3TB-OD201P-US G3TB-OD201PM-US Note: When ordering, specify the rated input voltage. Solid State Relay G3TB 387 Specifications Ratings (at an Ambient Temperature of 25C) Input Module Input Model Rated voltage Operating voltage Input current Voltage level Must operate voltage Must release voltage G3TB-IAZR02P-US 100 to 240 VAC 80 to 264 VDC G3TB-IDZR02P-US 4 to 24 VDC 3 to 32 VDC 5 mA max. 80 VAC max. 10 VAC min. 3 VDC max. 1 VDC min. Output Model G3TB-IAZR02P-US Logic level supply voltage Output breakdown voltage 4 to 32 VDC 32 VDC max. Output current 25 mA max. G3TB-IDZR02P-US Output Module Input Model Rated voltage Operating voltage Input current Voltage level Must operate voltage Must release voltage G3TB-OA203PZ-US 5 to 24 VDC 4 to 32 VDC G3TB-OA203PZM-US 4 to 24 VDC 3 to 32 VDC 5 mA max. 4 VDC max. 3 VDC max. G3TB-OA203PL-US 4 VDC max. 5 to 24 VDC 4 to 32 VDC G3TB-OA203PLM-US 4 to 24 VDC 3 to 32 VDC 3 VDC max. G3TB-ODX03P-US 5 to 24 VDC 4 to 32 VDC 4 VDC max. G3TB-ODX03PM-US 4 to 24 VDC 3 to 32 VDC 3 VDC max. G3TB-OD201P-US 5 to 24 VDC 4 to 32 VDC 4 VDC max. G3TB-OD201PM-US 4 to 24 VDC 3 to 32 VDC 3 VDC max. 1 VDC min. Output Model Applicable load Rated load voltage G3TB-OA203PZ-US Load voltage range Load current (See note.) Inrush current 100 to 240 VAC 75 to 264 VAC 0.05 to 3 A 45 A (60 Hz, 1 cycle) 5 to 48 VDC 4 to 60 VDC 0.01 to 3 A 18 A (10 ms) 48 to 200 VDC 40 to 200 VDC 0.01 to 1.5 A 12 A (10 ms) G3TB-OA203PZM-US G3TB-OA203PL-US G3TB-OA203PLM-US G3TB-ODX03P-US G3TB-ODX03PM-US G3TB-OD201P-US G3TB-OD201PM-US Note: The minimum current value is measured at 10C min. 388 Solid State Relay G3TB Characteristics Input Module Item G3TB-IAZR02P-US G3TB-IDZR02P-US Operate time 20 ms max. 1 ms max. Release time 20 ms max. 1 ms max. Output ON voltage drop 0.4 V max. Leakage current 100 A max. Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 4,000 VAC, 50/60 Hz for 1 min between input and output Vibration resistance Malfunction: 10 to 55 Hz, 1.5-mm single amplitude Shock resistance Malfunction: 1,000 m/s2 Ambient temperature Operating: Storage: Ambient humidity Operating: 45% to 85% Certified standards UL File No. E41515/CSA File No. LR35535/TUV R90381 (VDE0806) Weight Approx. 22 g -30C to 80C (with no icing or condensation) -30C to 100C (with no icing or condensation) Output Module Item G3TBOA203PZ-US G3TBOA203PZM-US G3TB-OA G3TB-OA G3TBG3TB203PL-US 203PLM-US ODX03P-US ODX03PM-US Operate time 1/2 of load power source cycle + 1 ms max. 1 ms max. Release time 1/2 of load power source cycle + 1 ms max. Output ON voltage drop 1.6 V max. Leakage current 5 mA max. (at 200 VAC) G3TB-OD 201P-US G3TB-OD 201PM-US 0.5 ms max. 2 ms max. 2.5 V max. 1 mA max. Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 4,000 VAC, 50/60 Hz for 1 min between input and output Vibration resistance Malfunction: 10 to 55 Hz, 1.5-mm single amplitude Shock resistance Malfunction: 1,000 m/s2 Ambient temperature Operating: -30C to 80C (with no icing or condensation) Storage: -30C to 100C (with no icing or condensation) Ambient humidity Operating: 45% to 85% Certified standards UL File No. E64562/CSA File No. LR35535/TUV R90381 (VDE0806) Weight Approx. 32 g Solid State Relay G3TB 389 Engineering Data Load Current vs. Ambient Temperature Characteristics G3TB-OD201P-US/-OD201PM-US Load current (A) Load current (A) G3TB-OA203PZ-US/-OA203PZM-US /-OA203PL-US/-OA203PLM-US/ G3TB-ODX03P-US/-ODX03PM-US Ambient temperature (C) Ambient temperature (C) One Cycle Surge Current: Non-repetitive Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.) Energized time (ms) 390 Solid State Relay Energized time (ms) G3TB G3TB-OD201P-US/-OD201PM-US Inrush current (A) G3TB-ODX03P-US/-ODX03PM-US Inrush current (A) Inrush current (A. Peak) G3TB-OA203PZ-US/-OA203PZM-US/ -OA203PL-US/-OA203PLM-US Energized time (ms) Operation Circuit Configuration Type AC input Model Case color G3TB-IAZR02P-US Yellow Indicator Circuit Yes Constantcurrent circuit Rectification circuit DC input G3TB-IDZR02P-US White Yes Constantcurrent circuit AC output G3TB-OA203PZ-US G3TB-OA203PL-US Black G3TB-ODX03P-US G3TB-OD201P-US Amplification circuit Yes G3TB-OA203PZM-US G3TB-OA203PLM-US DC output Amplification circuit No Red Constantcurrent circuit Zero cross circuit Constantcurrent circuit Amplification circuit Drive circuit Yes G3TB-ODX03PM-US G3TB-OD201PM-US No Example of Logic Output Circuit Example 1. G3TB-I Example 2. G3TB-I 4 to 32 VDC SW (+) 3.3 K +3 +3 Load Sequential circuit or CPU 4 ( ) (-) 3.3 K SW (+) 4 ( ) (-) -5 -5 4 to 32 VDC Example: Relay with built-in inrush absorption diode Logic circuitry Note: AC- and DC-input versions are available. Dimensions Note: All units are in millimeters unless otherwise indicated. Input SSR PCB Dimensions (Bottom View) G3TB-I Five, 1.3-dia. holes 2.54 10 max. 2.54 20.5 23.2 max. 6.05 6.6 10.16 12.7 5.08 5.08 Terminal Arrangement (Bottom View) 0.6 2 - 3 + 4 External input 5 - 1 ~ Output 2 ~ Vcc 3 + 4 5 - Vcc Load 1 + Output Solid State Relay Logic circuitry External input Logic circuitry 10.16 22.86 27.94 33.02 43.5 max. Load 6.050.1 G3TB 391 Output SSR PCB Dimensions (Bottom View) G3TB-O 10 max. Four, 1.2-dia. holes 2.54 2.54 30.5 33.2 max. 29.5 6.05 6.050.1 10.16 22.86 27.94 43.5 max. 6.6 12.7 External AC output 2 ~ Logic input 3 + 4 - External DC output 1 ~ Z2 Z1 Load 5.08 Terminal Arrangement (Bottom View) 0.6 1 ~ 10.16 2 ~ Logic input 3 + 4 - Z Load Note: Z1, Z2, and Z refer to overvoltage absorption elements that you should connect. 392 Solid State Relay G3TB Safety Precautions Precautions for Correct Use Please observe the following precautions to prevent failure to operate, malfunction, or undesirable effect on product performance. G3TB I/O classification by the color is as follows: AC equipment 100 to 240 VAC DC equipment 5 to 24 VAC G3TB-IAZR02P Yellow AC input module G3TB-IDZR02P White DC input module G3TB-OA203PZ 5 to 24 VDC 5 to 24 VDC Black G3TB-OA203PZM AC equipment 100 to 240 VAC 3 A 5 to 24 VDC (4 to 24 VDC) G3TB-OA203PL PLC or logic circuitry G3TB-OA203PLM AC output module G3TB-ODX03P Red G3TB-ODX03PM DC equipment 4 to 60 VDC/ 40 to 200 VAC 3 A G3TB-OD201P* 5 to 24 VDC (4 to 24 VDC) G3TB-OD201PM* *With 1.5-A output. DC output module When mounting more than one output module, make a distance of 5 mm minimum between adjacent SSRs. Up to 16-point, 3-A load switching is possible 5 mm min. Connection With the SSR for DC switching, the load can be connected to either positive or negative output terminal of the SSR. Output module Protective Component Since the SSR does not incorporate an overvoltage absorption component, be sure to connect an overvoltage absorption component when using the SSR under an inductive load. Complete "Terms and Conditions of Sale" for product purchase and use are on Omron's website at http://www.components.omron.com - under the "About Us" tab, in the Legal Matters section. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Solid State Relay G3TB 393 MEMO 394 Solid State Relay G3TB Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2010.1 14 OMRON Corporation Industrial Automation Company In the interest of product improvement, specifications are subject to change without notice. OMRON ELECTRONICS LLC * THE AMERICAS HEADQUARTERS * Schaumburg, IL USA * 847.843.7900 * 800.556.6766 * www.omron247.com OMRON CANADA, INC. * HEAD OFFICE Toronto, ON, Canada * 416.286.6465 * 866.986.6766 www.omron247.com OMRON ARGENTINA * SALES OFFICE Cono Sur * 54.11.4783.5300 OMRON ELETRONICA DO BRASIL LTDA * HEAD OFFICE Sao Paulo, SP, Brasil * 55.11.2101.6300 * www.omron.com.br OMRON CHILE * SALES OFFICE Santiago * 56.9.9917.3920 OMRON ELECTRONICS MEXICO SA DE CV * HEAD OFFICE Apodaca, N.L. * 52.811.156.99.10 * 001.800.556.6766 * mela@omron.com OTHER OMRON LATIN AMERICA SALES 54.11.4783.5300 Omron Europe B.V. Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. Tel: +31 (0) 23 568 13 00 Fax: +31 (0) 23 568 13 88 www.industrial.omron.eu Cat. No. J30I-E-01 06/09 Note: Specifications are subject to change. (c) 2010 Omron Electronics LLC