48
Compression
CAT. NO. WIRE SIZE Dimensions in. (mm) Die Set
Cat. No.
Color
Code
Code Flex Class G, H, I, K, M* A B
54504 #8 AWG #8 AWG, 37/24, #8 Weld 1.00 (25.4) 0.27 (6.9) 21 Red
54505 #6 AWG #6 AWG, 61/24, #6 Weld, 133/0.014 1.00 (25.4) 0.30 (7.6) 24 Blue
54506 #4 AWG #4 AWG, 91/24, 133/0.0177, 49/0.029 1.00 (25.4) 0.37 (9.4) 29 Grey
54507 #2 AWG 125/24, #4 Weld 1.25 (31.8) 0.41 (10.4) 33 Brown
54508 #1 AWG #2 AWG, 150/24, 175/24, #2 Weld, 133/0.0223 1.50 (38.1) 0.47 (11.9) 37 Green
54509 1/0 AWG 225/24, #1 Weld, 133/0.0254 1.63 (41.4) 0.52 (13.2) 42 Pink
54510 2/0 AWG 1/0 AWG, 275/24, 1/0 Weld, 427/0.0155, 133/0.0282 1.75 (44.5) 0.57 (14.5) 45 Black
54511 3/0 AWG 2/0 AWG, 325/24, 2/0 Weld, 133/0.0316, 259/0.0227, 427/0.0177 1.75 (44.5) 0.63 (16.0) 50 Orange
53962 375/24, 179 kcmil, 133/0.0355, 259/0.0255, 427/0.0199 1.81 (46.0) 0.70 (17.8) 50 Orange
54512 4/0 AWG 3/0 AWG, 450/24, 3/0 Weld, 703/0.0154 1.88 (47.8) 0.70 (17.8) 54 Purple
54513 250 kcmil 4/0 AWG, 550/24, 4/0 Weld, 133/0.0399, 259/0.0286, 637/0.0183 2.25 (57.2) 0.77 (19.6) 62 Yellow
53964 4/0 AWG, 550/24, 4/0 Weld, 133/0.0399, 259/0.0286, 637/0.0183 2.13 (54.1) 0.79 (20.1) 62 Yellow
54514 300 kcmil –2.13 (54.1) 0.83 (21.1) 66 White
54515 350 kcmil – 2.25 (57.2) 0.90 (22.9) 71 Red
54516 400 kcmil –2.75 (69.9) 0.93 (23.6) 76 Blue
53968 300 kcmil, 775/24 (313 kcmil) 3.00 (76.2) 1.13 (28.7) 87 Brown
54518 500 kcmil –2.75 (69.9) 1.11 (28.2) 87 Brown
54520 600 kcmil – 3.00 (76.2) 1.18 (30.0) 94 Green
54522-TB 700 kcmil –3.25 (82.6) 1.23 (31.2) 99 Pink
53969 1325/24 = 500/535 kcmil, 427/0.0342 3.00 (76.2) 1.24 (31.5) 99 Pink
54523-TB 750 kcmil –3.00 (76.2) 1.30 (33.0) 106 Black
54528 1000 kcmil – 3.63 (92.2) 1.50 (38.1) 125 N/A
54530 1250 kcmil –4.13 (104.9) 1.67 42.4) 140 N/A
Connectors for Copper Conductors
Two-Way Splice Connectors – Standard Barrel Certified to 600V
and Recommended up to 35 kV
A
E
Material: High-Conductivity
Wrought Copper
Finish: Electro Tin Plate
Two-way connectors provide high pullout values, are easy to
insulate and provide a low-resistance connection of high quality
and low installed cost.
CAT. NO. WIRE SIZE Dimensions in. (mm) Die
Code
Color
Code
Code Flex Class G, H, I, K, M A E
54804 #8 AWG #8, 37/24 = 14.9 kcmil 1.75 (44.5) 0.27 (6.9) 21 Red
54805 #6 AWG #6, 61/24 = 24.6 kcmil 1.75 (44.5) 0.31 (7.9) 24 Blue
54806 #4 AWG #4, 91/24 = 36.7 kcmil 1.75 (44.5) 0.39 (9.9) 29 Grey
54807 #2 AWG 125/24 = 50.4 kcmil 1.88 (47.8) 0.43 (11.0) 33 Brown
54808 #1 AWG #2, 150/24 = 60.5 kcmil
175/24 = 70.6 kcmil 2.00 (50.8) 0.49 (12.4) 37 Green
54809 1/0 AWG 225/24 = 90.8 kcmil 2.00 (50.8) 0.54 (13.7) 42 Pink
54810 2/0 AWG 1/0, 275/24 = 111 kcmil 2.13 (54.1) 0.59 (15.0) 45 Black
54811 3/0 AWG 2/0, 325/24 = 131 kcmil 2.25 (57.2) 0.65 (16.5) 50 Orange
54812 4/0 AWG 450/24 = 182 kcmil 2.75 (69.9) 0.72 (18.3) 54 Purple
54813 250 kcmil 4/0, 550/24 = 222 kcmil 3.38 (85.9) 0.79 (20.1) 62 Yellow
Two-Way Splice Connectors – Long Barrel Certified to 600V and
Recommended up to 35 kV Applications
*Contact Technical Services for specific stranding listings.
Tooling: pp. 116–145 Die Selector Chart: pp.146–153
Material: High-Conductivity
Wrought Copper
Finish: Electro Tin Plate E DIA.
54 DIE
PURPLE
54 DIE
PURPLE
54 DIE
PURPLE
54 DIE
PURPLE
T&B
4/0
A
CAT. NO. WIRE SIZE Dimensions in. (mm) Die
Code
Color
Code
Code Flex Class G, H, I, K, M AE
54814 300 kcmil 250, 650/24 = 262 kcmil 3.50 (88.9) 0.87 (22.1) 66 White
54815 350 kcmil –3.75 (95.3) 0.95 (24.1) 71 Red
54816 400 kcmil 775/24 = 313 kcmil 3.75 (95.3) 0.98 (24.9) 76 Blue
54818 500 kcmil 350, 925/24 = 373 kcmil 4.75 (120.6) 1.11 (28.2) 87 Brown
54820 600 kcmil 1100/24 = 444 kcmil 4.25 (108.0) 1.21 (30.7) 94 Green
54823 750 kcmil 500, 1325/24 = 535 kcmil 4.75 (120.6) 1.34 (34.0) 106 Black
58524 1600/24 = 646 kcmil 5.00 (127.0) 1.39 (35.3) 106 Black
58526* 900 kcmil 750, 1925/24 = 777 kcmil 5.50 (139.7) 1.51 (38.4) 115 Yellow
54828 1000 kcmil –5.63 (143.0) 1.56 (39.6) 125 N/A
54833 1500 kcmil –5.63 (143.0) 1.56 (39.6) 125 N/A
54839 2000 kcmil –7.06 (179.3) 2.13 (54.1) –N/A
*CSA approved code cable only
Tooling: pp. 116–145
Die Selector Chart: pp. 146–153
¥
¥ For installations from 16 kV up to 35 kV, consult shielded cable manufacturers for stress relief and insulation requirements.
¥
¥ For installations from 16 kV up to 35 kV, consult shielded cable
manufacturers for stress relief and insulation requirements.
¥ For installations from 16 kV up to 35 kV, consult shielded
cable manufacturers for stress relief and insulation
requirements.
Colorkeyed_e.pdf 48 11/7/2011 1:11:17 PM