611 Industrial Way West, Eatontown, NJ 07724 tel: 732-460-0212 fax: 732-460-0214 sales@advanced-control.com www.advanced-control.com
Features:
Exceptional Temperature Stability
Low Video Resistance (112 typical)
Flat Output vs. Frequency Over Broadband Performance
Very Fast Pulse Response
No Bias Required
Flexible Design Options
Applications:
Transmitter Monitoring
Missile Guidance Systems
Input to Low-Noise Amplifiers
Broadband Or Narrowband ECM Receivers
Power and Signal Monitors
Doppler Radar and Beacon Receivers
Matched units available for Multi-channel Receivers, Amplitude Comparator Systems and Discriminators
Minimum (2) Flatness Nominal (5)
Frequency Sensitivity vs Typical (3) Video Standard Optional
Range Part (1) K Frequency TSS Typical (4) Capacitance Case Case
(GHz) Number (mV/mW) (+/-dB) (dBm) VSWR (pF) Styles Styles
0.1 - 0.5 ACTP1523N 800 0.3 -51 2.5:1 270 C3 C8,C15,C62
0.1 - 1 ACTP1572N 900 0.4 -51 2.5:1 270 C3 C8,C15,C62
0.5 - 1 ACTP1524N 800 0.2 -51 2.5:1 39 C2 C3,C8,C15
0.1 - 2 ACTP1629N 900 0.35 -51 2.3:1 75 C3 C8,C15,C62
0.5 - 2 ACTP1501N 800 0.35 -51 2.3:1 39 C2 C3,C15
1 - 2 ACTP1525N 800 0.25 -51 2.5:1 20 C2 C3,C15
0.1 - 4 ACTP1573N 800 0.3 -51 2.3:1 75 C3 C8,C15,C62
2 - 4 ACTP1502N 800 0.2 -51 2.3:1 20 C2 C3,C15
2 - 6 ACTP1514N 800 0.5 -51 2.3:1 20 C32 C3,C5,C15
1 - 12 ACTP1663N 700 0.85 -50 2.5:1 20 C3 C8,C15,C62
2 - 8 ACTP1555N 750 0.5 -51 2.5:1 20 C2 C3,C8,C15
4 - 8 ACTP1503N 750 0.4 -51 2.5:1 9 C1 C3,C32
4 - 8 ACTP1648N 650 0.4 -50 2.0:1 12 C8 C15
6 - 12 ACTP1583N 750 0.4 -50 2.5:1 12 C3 C8,C15
8 - 12 ACTP1504N 700 0.4 -50 2.4:1 9 C1 C3
2 - 18 ACTP1528N 650 1.0 -50 2.8:1 12 C3 C32
0.5 - 18 ACTP1584N 600 1.3 -50 3.0:1 20 C32 C3,C15
1 - 18 ACTP1625N 650 1.1 -50 2.7:1 20 C32 C3,C15
6 - 18 ACTP1563N 600 0.9 -50 2.8:1 12 C32 C3,C15
7 - 18 ACTP1662N 650 1.0 -50 2.7:1 12 C32 C3
8 - 18 ACTP1506N 650 0.7 -50 2.3:1 12 C1 C3
12 - 18 ACTP1505N 700 0.4 -51 2.1:1 9 C1 C3
NOTES:
1) Standard output polarity is negative. If positive output is required, substitute “P” for “N” in part number.
2) Diode values can be changed to alter the level of sensitivity. As sensitivity is increased, VSWR will degrade. VSWR will improve as
sensitivity is lowered. Flatness and TSS will also be influenced by these changes. If your applications require something special,
please contact the factory.
3) Tangential Signal Sensitivity (TSS) is a measure of low level sensitivity with respect to noise. It is measured using a video amplifier with
a 2MHz bandwidth and a 3dB noise figure.
4) VSWR measured at or below -20dBm input power level.
5) Video capacitance is used for RF bypass. This value can be changed if required for video response time or other considerations.
Contact the factory if value other than those shown are needed.
Superior performance and high reliability are designed into these detectors.
They offer extremely stable output voltage over wide temperature excursions,
typically +/-0.15dB from -65°C to +100°C at 1GHz and approx. +/-0.3dB at
18GHz. No bias is required for operation. Designs are available, in selected
frequency bands, from 100MHz (or lower) to 18GHz. Typical output impedance
is in the range of 95 to 125. This allows for fast pulsed video response and
use in wide bandwidth requirements. Video bandwidths may be modified by
selection of the RF bypass capacitor and load value. Square law typically
ranges from TSS up to -17dBm. The upper limit can be raised as high as -
13dBm with selected load values. The output polarity is usually negative but
can be made positive if requested.
COAXIAL TUNNEL DIODE DETECTORS
611 Industrial Way West, Eatontown, NJ 07724 tel: 732-460-0212 fax: 732-460-0214 sales@advanced-control.com www.advanced-control.com
ENVIRONMENTAL SPECIFICATIONS: SCREENING :
MIL-E-5400, MIL-STD-202, MIL-E-16400 Standard Screening:
Operating Temp: -65°C to +100°C Internal Visual per MIL-STD-883, Method 2017
Storage Temp: -65°C to +100°C Temperature Cycle: -65°C to +100°C, 10 cycles
Humidity: MIL-STD-202F, M103, Cond B Optional High-Rel Screening (Ref MIL-PRF-38534):
Shock: MIL-STD-202F, M213, Cond B Internal Visual per MIL-STD-883, Method 2017
Altitude: MIL-STD-202F, M105, Cond B Stabilization Bake per MIL-STD-883, Method 1008
Vibration : MIL-STD-202F, M204, Cond B Temperature Cycle per MIL-STD-883, Method 1010
Thermal Shock: MIL-STD-202F, M107, Cond A Constant Acceleration per MIL-STD-883, Method 2001
Temperature Cycle: MIL-STD-202F, M105C, Cond D Burn-in per MIL-STD-883, Method 1015
Maximum Input Power: +14dBm Leak Test per MIL-STD-883, Method 1014
(This allows for 3dB margin from possible burnout at +17dBm) External Visual per MIL-STD-883, Method 2009
CASE STYLE C1 CASE STYLE C2 CASE STYLE C3 CASE STYLE C5
CASE STYLE C8 CASE STYLE C15 CASE STYLE C32 CASE STYLE 62
Part Number Ordering Information: Example: ACTP1555NC312
ACTP1555: Coaxial Tunnel Diode Detector, 2 – 8GHz
N: Negative output polarity
C3: Package type
12: 12pF custom video capacitance (omit for standard value)
TP-0205
SMA
MALE
(INPUT)
Ø0.312
SMA
FEMALE
(OUTPUT)
1.73±0.020
2.80±0.020
BNC
FEMALE
(OUTPUT)
Ø0.625
TYPE-N
MALE
(INPUT)
1.36±0.020
Ø0.312
SMA
MALE
(INPUT)
SMA
FEMALE
(OUTPUT)
Ø0.312
1.32±0.020
SMA
MALE
(INPUT)
SMA
FEMALE
(OUTPUT)
BNC
FEMALE
(OUTPUT)
SMA
MALE
(INPUT)
2.00
0.43
0.42
Ø0.500
Ø0.312
SMA
FEMALE
(OUTPUT)
SMA
MALE
(INPUT)
1.16±0.020
SMA
FEMALE
(OUTPUT)
Ø0.312
SMA
FEMALE
(INPUT)
1.22±0.050
SMA FEMALE
(OUTPUT)
SMA MALE
(INPUT)
Ø0.312
1.55±0.020