littelfuse.com© 2015 Littelfuse
Specifications are subject to change without notice.
DRR-129 50.8mm Close-Differential Reed Switch
Description
The DRR-129 Reed Switch is a standard, normally open switch with a 50.80mm
long x 5.25mm diameter (2.000” x .207”) glass envelope, capable of high voltage
and power switching up to 400Vdc at 100W. Will carry 6A and switch 3A. It has
high insulation resistance of 1010 ohms minimum and contact resistance of less
than 100 milli-ohms.
Agency Approvals
Agency Agency File Number Ampere-Turns Range
E47258
E471070 42-83 AT
DEMKO 14 ATEX 1393U 42-83 AT
Switch Type
Contact Form A (SPST-NO)
Materials Body: Glass
Leads: Tin-plated Ni-Fe wire
Axial Lead Reed Switches
Features
• Normally open switch
• Capable of switching 400Vdc or
3.0A at up to 100W
• Minimum voltage breakdown
600Vdc
• Available sensitivity range
42-83 AT
Benefits
• Hermetically sealed switch
contacts are not affected by and
have no effect on their external
environment
• Capable of switching European
mains voltage
• Zero operating power required for
contact closure
Applications
• Security
• Limit switching
• Industrial safety applications
Dimensions
Dimensions in mm (inch)
High Power > DRR-129
RoHS
Note: SPST-NO = Single-pole, single-throw, normally open
Electrical Ratings
Contact Rating 1W/VA - max. 100
Voltage 3
Switching 2
Breakdown 4
Vdc - max.
Vac - max.
Vdc - min.
400
280
600
Current 3
Switching 2
Carry
Adc - max.
Aac - max.
Adc - max.
3.0
2.1
6.0
Resistance Contact, Initial
Insulation
Ω - max.
Ω - min.
0.100
1010
Capacitance Contact pF - typ. 0.6
Temperature Operating
Storage 5
°C
°C
-40 to +125
-65 to +125
Notes:
1. Contact rating - Product of the switching voltage and current should never exceed the wattage rating. Contact Littelfuse for additional load/life information.
2. When switching inductive and/or capacitive loads, the effects of transient voltages and/or currents should be considered. Refer to Application Notes AN108A and AN107 for details.
3. Electrical Load Life Expectancy - Contact Littelfuse with voltage, current values along with type of load.
4. Breakdown Voltage - per MIL-STD-202, Method 301.
5. Storage Temperature - Long time exposure at elevated temperature may degrade solderability of the leads
41.27
(1.625) REF.
12.70
(.500) REF.
15.24
(.600) MIN.
50.80
(2.000) MAX.
82.55
5.25
(.207) MAX.
0.53