1E3X-DA-S
Digital Fiber Sensors
E3X-DA-S
High functionality digital fiber
amplifier
High functionality digital fiber amplifier with advanced timing,
LED power control and signal processing functionality
providing highest detection accuracy and stability even for the
most challenging objects and settings.
Power tuning function to adjust the received light to a
maximum, minimum or pre-defined value
Auto power and threshold adjustment functions for highest
operational stability
Two outputs for window monitoring
or two level detections (e.g. object + object state change)
Ordering information
Fiber amplifier connectors
Mounting Bracket End Plate
Item
Function Order code
Power
tuning Timer
Auto-
threshold
compensa-
tion (ATC)
Twin out-
put
External
input
Diffe-
rential
operation
Wet
process
'tough
mode’
Power
saving 'Eco'
functions
(display/
LED off)
NPN PNP
Pre-wired Yes Yes Yes Yes Yes Yes Yes Yes E3X-DA21-S 2M E3X-DA51-S 2M
Fiber amplifier
connector*1
*1. Order fiber amplifier connector E3X-CN_ separately
Yes Yes Yes Yes - selectable Yes Yes Yes E3X-DA7-S E3X-DA9-S
M8 con-
nector
3 pin Yes Yes *2
*2. For fiber amplifiers with these functions and connecting with M8 connector, order the fiber amplifier connector models above and the
pigtail connector E3X-CN21-M3J-2 with 30cm PVC cable and M8 plug.
E3X-DA13-S E3X-DA43-S
4 pin E3X-DA14-S E3X-DA44-S
Shape Type Comment Order code
Fiber amplifier
connector
2 m PVC cable E3X-CN21
30 cm PVC cable with M12 plug connector (4 pin) E3X-CN21-M1J 0.3M
30 cm PVC cable with M8 plug connector (4 pin) E3X-CN21-M3J-2 0.3M
Appearance Model Quantity
E39-L143 1
Appearance Model Quantity
PFP-M 1
E10E-EN-05+E3X-DA-S+Datasheet.fm Seite 1 Donnerstag, 6. Oktober 2011 4:51 16
2
Features
Power tuning
Timer functions
Adjust the output signal length and timing
Active-threshold control (ATC)
ON delay OFF delay One-shot ON delay and OFF delay
T1: ON-delay set time
T2: OFF-delay set time
T1 and T2 can be set
separately.
Increase or decrease the LED
power and received light intensity
to the desired level e.g. a pre-
defined value.
Incident light
No incident light
ON
OFF
ON
OFF
L-ON
D-ON
T
T
Incident light
No incident light
ON
OFF
ON
OFF
L-ON
D-ON
T
T
Incident light
No incident light
ON
OFF
ON
OFF
L-ON
D-ON
T
T
Incident light
No incident light
ON
OFF
ON
OFF
L-ON
D-ON
T2T1
T1T2
Triggering on single or double signal edges
Output 1: ON
Output 2: OFF
The two outputs can be used to detect two different light levels
Output 1: ON
Output 2: ON
Twin output Differential detection
T/ms
Output V Received light
Sensor output
Threshold
without ATC
Incident level
ATC threshold
Without ATC: malfunction caused by
temperature drift, pollution or condensation
Operation with ATC
Operation without ATC
Higher signal stability compensating for
power reduction caused by temperature drift,
dust or condensation.
E10E-EN-05+E3X-DA-S+Datasheet.fm Seite 2 Donnerstag, 6. Oktober 2011 4:51 16
3E3X-DA-S
Specifications
Input Specifications
Amplifier unit connectors
Item Pre-wired models Fiber amplifier connector models M8 connector models
E3X-DA_ 1-S E3X-DA7-S, E3X-DA9-S E3X-DA_ 3-S, E3X-DA_ 4-S
Light source
(wave length)
Red LED (650 nm) Red LED (625 nm)
Power supply
voltage
12 to 24 VDC ± 10%; ripple (p-p): 10% max
Protective circuits Reverse polarity protection, output short circuit protection, mutual interference prevention*1
*1. The reverse polarity protection for the pre-wired and fiber amplifier connector models is for the power supply and the output. For M8 connector models the reverse
polarity protection is for the power supply.
Response time
Super-high-speed
mode*2
*2. The communication function and mutual interference prevention function are disabled if detection is set to Super-high-speed Mode.
80 µs for operation and reset max. 55 µs for operation and reset max.
Standard mode 1 ms for operation and reset
High
resolution mode
4 ms for operation and reset
Wet process
'tough mode'
16 ms for operation and reset *3
*3. For fiber amplifiers with these functions and connecting with M8 connector, order the fiber amplifier connector models above and the
pigtail connector E3X-CN21-M3J-2 with 30 cm PVC cable and M8 plug.
Sensitivity setting Teaching and digital up/down keys
Functions
Power tuning Light emission power and reception gain, digital control method
Timer OFF-delay, ON-delay, one-shot timer. 1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms incre-
ments, 200 ms to 1 s set in 100-ms increments, and 1 to 5 s set in 1 s-increments)
Auto power
control (APC)
LED power monitoring and auto-control function by LED emission current adjustment.
Active-threshold
control (ATC)
Monitoring of received light average and deviation adjustment of
threshold for output 1
*3
Twin
output
Output 1: incident level
Output 2: incident level or alarm output
Output 1: incident level
Output 2: incident level or alarm output
(not available if external input is used)
*3
External
input
External teach or function trigger (pow-
er tuning, emitter OFF, ATC start)
External teach or function trigger (pow-
er tuning, emitter OFF, ATC start) (not
available if output 2 is used)
*3
Differential opera-
tion
Single edge or double edge detection mode *3
Wet process
'tough mode'
Incident level triggering on floating average of received light. *3
Power saving
'Eco' functions
LED: ON/OFF switchable (external input)
Display: ON/ DIM / OFF selectable (Eco mode*4)
*4. When the ECO Mode is enabled, the rated sensing distance is approx. 1/2 and the incident level is approx. 1/3 of the normal levels.
*3
Digital display Incident level + threshold or user specific
Contact input (relay or switch) Non-contact input (transistor)
NPN ON: Shorted to 0 V (sourcing current: 1 mA max.).
OFF: Open or shorted to Vcc.
ON: 1.5 V max. (sourcing current: 1 mA max.)
OFF: Vcc - 1.5 V to Vcc (leakage current: 0.1 mA max.)
PNP ON: Shorted to Vcc (sinking current: 3 mA max.).
OFF: Open or shorted to 0 V.
ON: Vcc - 1.5 V to Vcc (sinking current: 3 mA max.)
OFF: 1.5 V max. (leakage current: 0.1 mA max.)
E3X-CN21_
Rated current 2.5 A
Rated voltage 50 V
Contact resistance 20 mmax. (20 mVDC max., 100 mA max.) (The figure is for connection to the amplifier unit and the adjacent con-
nector. It does not include the conductor resistance of the cable.)
No. of insertions Destruction: 50 times (The figure for the number of insertions is for connection to the amplifier unit and the adjacent
connector.)
Mate-
rials
Housing Polybutylene terephthalate (PBT)
Contacts Phosphor bronze/gold-plated nickel
Weight (packed state) Approx. 55 g
E10E-EN-05+E3X-DA-S+Datasheet.fm Seite 3 Donnerstag, 6. Oktober 2011 4:51 16
4
Exemplary sensing distances
(measured with E3X-DA51-S 2M) *1 (Unit: mm)
Reflective Models (Unit: mm)
Type Tough Mode High-resolution
Mode Standard Mode High-speed
Mode
Super-high-
speed Mode
Through-beam
E32-T11N/
E32-TC200BR(B4R) 2,000 1,400 1,000 700 280
E32-T14LR/E32-T15YR/
E32-T15ZR 750 550 450 260 100
E32-T21R/E32-T22R/
E32-T222R/
E32-TC200FR(F4R)
450 300 250 150 60
E32-T24R 170 120 100 50 20
E32-TC200/E32-T12/
E32-T15X/E32-TC200B(B4) 2,800 2,000 1,550 1,000 400
E32-T14L/E32-T15Y/
E32-T15Z 1,700 1,200 950 600 240
E32-TC200A 2,500 1,800 1,350 900 360
E32-TC200E/E32-T22/
E32-T222/
E32-TC200F(F4)
750 550 450 250 100
E32-T24 450 300 250 150 60
E32-T11/E32-T12B/
E32-T15XB 2,500 1,800 1,350 900 360
E32-T21/E32-T221B/
E32-T22B 680 480 400 220 90
E32-T11U 2,500 1,800 1,350 900 360
E32-T17L 20,000*1
*1. The sensing distances with M8 connector models E3X-DA[]3-S and E3X-DA@4-S are approximately 50% of the exemplary values measured with E3X-DA51-S.
20,000*120,000*120,000*18,000
Type Tough Mode High-resolution
Mode Standard Mode High-speed
Mode
Super-high-
speed Mode
Diffuse-
reflective
E32-D11N/
E32-D12R/E32-D15XR/
E32-DC200BR(B4R)
840 600 350 240 100
E32-D14LR 220 160 100 60 28
E32-D15YR/E32-D15ZR 200 140 100 52 24
E32-D211R/E32-D21R/
E32-D22R/
E32-DC200FR(F4R)
140 100 60 40 16
E32-D24R 70 52 30 20 8
E32-DC200/E32-D15X/
E32-DC200B(B4) 1,400 1,000 600 400 180
E32-D12 1,120 800 450 320 140
E32-D14L 560 400 220 160 72
E32-D15Y/E32-D15Z 480 340 200 130 60
E32-D211/E32-DC200E/
E32-D22/
E32-DC200F(F4)
360 260 160 100 44
E32-D24 140 100 60 40 16
E32-D11/E32-D15XB 840 600 350 240 100
E32-D21B/E32-D221B 300 220 280 90 40
E32-D21/E32-D22B 140 100 60 40 16
E32-D11U 840 600 350 240 100
E10E-EN-05+E3X-DA-S+Datasheet.fm Seite 4 Donnerstag, 6. Oktober 2011 4:51 16
5E3X-DA-S
I/O Circuit Diagrams
NPN Output
PNP Output
Note: 1 .Operation with area settings is as follows:
LIGHT ON: ON when the incident level is between the thresholds for channels 1 and 2.
DARK ON: OFF when the incident level is between the thresholds for channels 1 and 2.
2 .Not available for M8 connector types E3X-DA4@-S and E3X-DA1@-S.
Model Operation
mode Timing charts Operation
selector Output circuit
E3X-DA21-S
Light-ON LIGHT ON
(L-ON)
Dark-ON DARK ON
(D-ON)
E3X-DA7-S
Light-ON LIGHT ON
(L-ON)
Dark-ON DARK ON
(D-ON)
Model Operation
mode Timing charts Operation
selector Output circuit
E3X-DA51-S
Light-ON LIGHT ON
(L-ON)
Dark-ON DARK ON
(D-ON)
E3X-DA9-S
Light-ON LIGHT ON
(L-ON)
Dark-ON DARK ON
(D-ON)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
(Between brown and black leads)
ch1/
ch2
Operation indicator
(orange)
Output transistor
Load
(e.g., relay) Load
Load
Operation indicator
(orange) ch2 Brown
Black
Control output
ch1
Control output
ch2
External
input
Orange
Blue
Pink
12 to
24 VDC
Opera-
tion
indicator
(orange)
ch1
Display
Photo-
electric
Sensor
main
circuit
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
(Between brown and black leads)
ch1/
ch2
Operation indicator
(orange)
Output transistor
Load
(e.g., relay)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
(Between brown and black leads)
ch1/
ch2
Operation indicator
(orange)
Output transistor
Load
(e.g., relay) Load
Load
Operation indicator
(orange) ch2 Brown
Black
Control output
ch1
Control output
ch2
Orange
Blue
12 to
24 VDC
Opera-
tion
indicator
(orange)
ch1
Display
Photo-
electric
Sensor
main
circuit
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
(Between brown and black leads)
ch1/
ch2
Operation indicator
(orange)
Output transistor
Load
(e.g., relay)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
(Between blue and black leads)
ch1/
ch2
Operation indicator
(orange)
Output transistor
Load
(e.g., relay)
Load
Load
Operation indicator (orange) ch2
Brown
Black
Control output
ch1
Control
output ch2
External
input
Orange
Blue
Pink
12 to
24 VDC
Opera-
tion
indicator
(orange)
ch1
Display
Photo-
electric
Sensor
main
circuit
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
(Between blue and black leads)
ch1/
ch2
Operation indicator
(orange)
Output transistor
Load
(e.g., relay)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
(Between blue and black leads)
ch1/
ch2
Operation indicator
(orange)
Output transistor
Load
(e.g., relay)
Load
Load
Operation indicator (orange) ch2
Brown
Black
Control output
ch1
Control
output ch2
Orange
Blue
12 to
24 VDC
Opera-
tion
indicator
(orange)
ch1
Display
Photo-
electric
Sensor
main
circuit
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
(Between blue and black leads)
ch1/
ch2
Operation indicator
(orange)
Output transistor
Load
(e.g., relay)
E10E-EN-05+E3X-DA-S+Datasheet.fm Seite 5 Donnerstag, 6. Oktober 2011 4:51 16
6
M8 connector models
NPN Output
PNP Output
Connector Pin Arrangement for 4-pole connector
Note:Terminal 2 is not used
Model Operation
mode Timing charts Operation
selector Output circuit
E3X-DA13-S
E3X-DA14-S
Light-ON LIGHT ON
(L-ON)
Dark-ON DARK ON
(D-ON)
Model Operation
mode Timing charts Operation
selector Output circuit
E3X-DA43-S
E3X-DA44-S
Light-ON LIGHT ON
(L-ON)
Dark-ON DARK ON
(D-ON)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
(Between brown and black leads)
ch1/
ch2
Operation indicator
(orange)
Output transistor
Load
(e.g., relay)
DisplayOperation indicator
(orange)
Power
tuning
indicator
(orange) Photo-
electric
Sensor
main
circuit
Brown
Black Load
Control output
Blue
12 to
24 VDC
1
4
3
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
(Between brown and black leads)
ch1/
ch2
Operation indicator
(orange)
Output transistor
Load
(e.g., relay)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
(Between blue and black leads)
ch1/
ch2
Operation indicator
(orange)
Output transistor
Load
(e.g., relay)
Display
Photo-
electric
Sensor
main
circuit
Brown
Black
Load
Control
output
Blue
12 to
24 VDC
Operation indicator
(orange)
Power
tuning
indicator
(orange)
1
4
3
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
(Between blue and black leads)
ch1/
ch2
Operation indicator
(orange)
Output transistor
Load
(e.g., relay)
13
24
E10E-EN-05+E3X-DA-S+Datasheet.fm Seite 6 Donnerstag, 6. Oktober 2011 4:51 16
7E3X-DA-S
Nomenclature
Amplifier Units
E3X-DA@-S (@: 21/51/7/9)
Safety Precautions
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Do not use the Sensor with voltage in excess of the
rated voltage. Excess voltage may result in
malfunction or fire.
Never use the Sensor with an AC power supply.
Otherwise, explosion may result.
Precautions for Safe Use
The following precautions must be observed to ensure safe opera-
tion of the Sensor.
1. Do not use the Sensor in an environment where explosive or
flammable gas is present.
2. Do not use the Sensor in a location subject to splattering with
water, streams, oils, or chemicals.
3. Do not attempt to disassemble, repair, or modify the Sensor.
4. Do not apply voltages or currents that exceed the rated range to
the Sensor.
5. Do not use the Sensor in an ambient atmosphere or environment
that exceeds the ratings.
6. Wire the power supply correctly, including the polarity.
7. Connect the load correctly.
8. Do not short-circuit the load at both ends.
9. Do not use the Sensor if the case is damaged.
10.Dispose of the Sensor as industrial waste.
11.Do not use the Sensor in locations subject to direct sunlight.
Precautions for Correct Use
Do not use the product in atmospheres or environments that exceed
product ratings.
Amplifier Unit
Designing
Operation after Turning Power ON
The Sensor is ready to detect within 200 ms after the power supply is
turned ON. If the Sensor and load are connected to separate power
supplies, be sure to turn ON the Sensor first.
Time may be required for the incident level to stabilize after the
power supply is turned ON.
Operation at Power OFF
A pulse may be output when the power supply is turned OFF. Turn
OFF the power supply to the load or the load line before turning OFF
the power supply to the Sensor.
Mounting
Connecting and Disconnecting Connectors
Mounting Connectors
1. Insert the Master or Slave Connector into the Amplifier Unit until it
clicks into place.
2. Attach the protective seals (provided as accessories) to the sides
of master and slave connectors that are not connected.
Note:Attach the seals to the sides with grooves.
Removing Connectors
1. Slide the slave Amplifier Unit away from the other Unit.
2. After the Amplifier Unit has been separated, press down on the
lever on the Connector and remove it. (Do not attempt to remove
a Connector without first separating the Amplifier Unit from the
other Units.)
To ensure safe operation, be sure to read and follow the Instruction Manual provided with the Sensor.
Locks the fiber.
Incident level, function, etc. Threshold, function settings,
etc.
Use to select the channel to display and set.
Use to select SET or RUN Mode.
Function setting
operations UP
DOWN
MODE
ON when output is ON.
OFF when output is OFF.
Operation Indicator
(ch1) (orange)
Lock lever
Main Display (Red) Sub-Display (Green)
Channel Selector
Mode Selector
ON when output is ON.
OFF when output is OFF.
Operation Indicator
(ch2) (orange)
Operation Keys
WARNING
CAUTION
Insert
Remove
Lever
Press down
E10E-EN-05+E3X-DA-S+Datasheet.fm Seite 7 Donnerstag, 6. Oktober 2011 4:51 16
8
Adding and Removing Amplifier Units
Adding Amplifier Units
1. Mount the Amplifier Units one at a time onto the DIN track.
2. Slide the Amplifier Units together, line up the clips, and press the
Amplifier Units together until they click into place.
Removing Amplifier Units
Slide Amplifier Units away from each other, and remove from the DIN
track one at a time. (Do not attempt to remove Amplifier Units from
the DIN track without separating them first.)
Note 1. The specifications for ambient temperature will vary accord-
ing to the number of Amplifier Units used together. For details,
refer to Input Specifications on page 3.
2. Always turn OFF the power supply before joining or separat-
ing Amplifier Units.
Mounting the End Plate (PFP-M)
Use an End Plate if the Amplifier Unit might move due to vibration.
Fiber Connection
The E3X Amplifier Unit has a lock button for easy connection of the
Fiber Unit. Connect or disconnect the fibers using the following pro-
cedures:
1. Connecting Fibers
Open the protective cover, insert the fibers according to the fiber
insertion marks on the side of the Amplifier Unit, and lower the lock
lever.
Note:Do not pull on the fiber, apply pressure on it, or otherwise sub-
ject it to excessive force when it is attached to the Amplifier Unit.
(Use a force of 0.3 N·m max.)
Fibers with E39-F9 Attachment
Fibers That Cannot Be Free-Cut (with Sleeves)
2. Disconnecting Fibers
Remove the protective cover and raise the lock lever to pull out the
fibers.
Note 1. To maintain the fiber properties, confirm that the lock is re-
leased before removing the fibers.
2. Be sure to lock or unlock the lock button within an ambient
temperature range between 10C and 40C.
Adjusting
Mutual Interference Protection Function
The values that appear on the digital display may fluctuate somewhat
due to light from other Sensors. If this occurs, you can stabilize
detection by lowering the threshold to provide a greater margin in the
allowable values.
Output Short-circuits
OVER/CUR will flash on the display if the output short-circuit function
operates due to a load short-circuit in a control output. If this occurs,
check the load connections.
EEPROM Writing Error
If the data is not written to the EEPROM correctly due to a power fail-
ure or static-electric noise, initialize the settings with the keys on the
Amplifier Unit. ERR/EEP will flash on the display when a writing error
has occurred.
Optical Communications
Several Amplifier Units can be slid together and used in groups. Do
not, however, slide the Amplifier Units or attempt to remove any of
the Amplifier Units during operation.
Others
Protective Cover
Always keep the protective cover in place when using the Amplifier
Unit.
Mobile Console
The E3X-MC11-SV2 Mobile Console does not currently support the
new Tough Mode and ON-delay + OFF-delay timer. You also cannot
use the E3X-MC-S.
Communications Unit
Use an E3X-DRT21-S Version 3 Communications Unit.
Click into place
End Plate
9 mm
Insertion position
Locked Unlocked
Protective cover
Lock button
Fiber insertion mark
Fiber
Fiber Unit
9 mm
13 mm
9 mm
13 mm
Locked Unlocked
Protective cover
E10E-EN-05+E3X-DA-S+Datasheet.fm Seite 8 Donnerstag, 6. Oktober 2011 4:51 16
9E3X-DA-S
Dimensions
Amplifier Units
(Unit: mm)
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
10
4.5
5.65
Two,
2.4 dia.
3.4
3.9 × 3
= 11.7
12.15
15.1
32.8
3.25
29.8
3.9 × 3 = 11.7
4.3
70
32
12.5
9.9
16
3.4 4.4
34.8
28.1
1628.1
16
18.7
44.3
A *
Hole for optical communications
Mounting Bracket (E39-L143): Sold separately.
SUS304 stainless steel
Two, M3
Two, 3.2-dia. holes
* The Mounting Bracket can
also be used on this side.
Operation indicator (1ch)
Main displaySub-displayVinyl-insulated round cable
Standard length: 2 m *
Operation indicator (2ch)
* Cable Specifications
With Mounting Bracket Attached
Mounting Holes
E3X-DA21-S
E3X-DA51-S
4-dia., 5-conductor (Conductor
cross section: 0.2 mm2, insulator
diameter: 1.1 mm)
Pre-wired Models
E3X-DA21-S
E3X-DA51-S
E10E-EN-05+E3X-DA-S+Datasheet.fm Seite 9 Donnerstag, 6. Oktober 2011 4:51 16
10
Operation indicator (1ch)
Main display Sub-display
Operation indicator (2ch)
10
4.5
5.65
Two,
2.4 dia.
3.4
3.9 × 3
= 11.7
12.15
15.1
32.8
3.25
29.8
3.9 × 3 = 11.7
A *1
4.3 70
8.1
32
12.95
9.9
16
34.8
28.1
18.7
44.3
Hole for optical communications
Mounting Bracket (E39-L143): Sold separately.
SUS304 stainless steel
Two, 3.2-dia. holes
3.4 4.4
16
Two, M3
Connector
Dia. A *2
*1. The Mounting Bracket can
also be used on this side.
*2. Cable Diameters
16 28.1
Models with fiber amplifier connectors
E3X-DA7-S
E3X-DA9-S
With Mounting Bracket Attached
Mounting Holes
E3X-CN21
(4 conductors) 4.0 dia.
E10E-EN-05+E3X-DA-S+Datasheet.fm Seite 10 Donnerstag, 6. Oktober 2011 4:51 16
11E3X-DA-S
Main displaySub display
Operating indicator Circle: Power tuning indicator
Oval: Second operating indicator
16
44.3
12.65
9.9
28.1
18.7
32
70
4.3
3.4
34.8
11.2
M8*2
28.1 16
4.4
3.4
12.15
15.133.9x3=11.7
29.8
3.25
32.783.9x3=11.7
B*1
5.65 4.5
10
16
3
1
4
*1. The Mounting Bracket can
also be used on this side.
*2. Connector size
Two,
2.4 dia.
Two,
3.2 dia.
Optical communication
position
Two, M 3
Models with M8 connectors
E3X-DA13-S
E3X-DA14-S
E3X-DA43-S
E3X-DA44-S
With Mounting Bracket Attached
Mounting Holes
16
44.3
12.65
9.9
28.1
18.7
32
70
4.3
3.4
34.8
11.2
M8*2
28.1 16
4.4
3.4
12.15
15.133.9x3=11.7
29.8
3.25
32.783.9x3=11.7
B*1
5.65 4.5
10
16
3
1
24
*1. The Mounting Bracket can
also be used on this side.
*2. Cable Diameters
Two,
2.4 dia.
Two,
3.2 dia.
Optical communication
position
Two, M 3
Mounting Holes
With Mounting Bracket Attached
E3X-DA14-S
E3X-DA44-S
E3X-DA13-S
E3X-DA43-S
E10E-EN-05+E3X-DA-S+Datasheet.fm Seite 11 Donnerstag, 6. Oktober 2011 4:51 16
12
Amplifier Unit Connectors
Master Connectors
E3X-CN21
14.4
2.6
6
2.9
0.8 8.4
6.8
10.7
50+50
0
30±2
4 dia.
10±2
4
15.1
6
,0
*
* E3X-CN21: 4-dia. vinyl-insulated round cable with 4 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm)
E10E-EN-05+E3X-DA-S+Datasheet.fm Seite 12 Donnerstag, 6. Oktober 2011 4:51 16
13E3X-DA-S
E10E-EN-05+E3X-DA-S+Datasheet.fm Seite 13 Donnerstag, 6. Oktober 2011 4:51 16
14
READ AND UNDERSTAND THIS DOCUMENT
Please read and understand this document before using the
products. Please consult your OMRON representative if you have
any questions or comments.
WARRANTY
OMRON’s exclusive warranty is that the products are free from
defects in materials and workmanship for a period of one year (or
other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION,
EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE
OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES
THAT THE BUYER OR USER ALONE HAS DETERMINED THAT
THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS
OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL,
INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS
OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE
PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT,
WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the
individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR
WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE
PRODUCTS UNLESS OMRON’S ANALYSIS CONFIRMS THAT
THE PRODUCTS WERE PROPERLY HANDLED, STORED,
INSTALLED, AND MAINTAINED AND NOT SUBJECT TO
CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE
MODIFICATION OR REPAIR.
SUITABILITY FOR USE
THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT
SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR
ENSURING SAFETY OF PERSONS, AND SHOULD NOT BE
RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE
DEVICE FOR SUCH PURPOSES. Please refer to separate catalogs
for OMRON's safety rated products.
OMRON shall not be responsible for conformity with any standards,
codes, or regulations that apply to the combination of products in the
customer’s application or use of the product.
At the customer’s request, OMRON will provide applicable third party
certification documents identifying ratings and limitations of use that
apply to the products. This information by itself is not sufficient for a
complete determination of the suitability of the products in
combination with the end product, machine, system, or other
application or use.
The following are some examples of applications for which particular
attention must be given. This is not intended to be an exhaustive list
of all possible uses of the products, nor is it intended to imply that the
uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or
electrical interference, or conditions or uses not described in this
document.
Nuclear energy control systems, combustion systems, railroad
systems, aviation systems, medical equipment, amusement
machines, vehicles, safety equipment, and installations subject to
separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or
property.
Please know and observe all prohibitions of use applicable to the
products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING
THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO
ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS
PROPERLY RATED AND INSTALLED FOR THE INTENDED USE
WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PERFORMANCE DATA
Performance data given in this document is provided as a guide for
the user in determining suitability and does not constitute a warranty.
It may represent the result of OMRON’s test conditions, and the
users must correlate it to actual application requirements. Actual
performance is subject to the OMRON Warranty and Limitations of
Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time
based on improvements and other reasons.
It is our practice to change model numbers when published ratings or
features are changed, or when significant construction changes are
made. However, some specifications of the product may be changed
without any notice. When in doubt, special model numbers may be
assigned to fix or establish key specifications for your application on
your request. Please consult with your OMRON representative at any
time to confirm actual specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for
manufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is
believed to be accurate; however, no responsibility is assumed for
clerical, typographical, or proofreading errors, or omissions.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user’s programming of a
programmable product, or any consequence thereof.
COPYRIGHT AND COPY PERMISSION
This document shall not be copied for sales or promotions without
permission.
This document is protected by copyright and is intended solely for
use in conjunction with the product. Please notify us before copying
or reproducing this document in any manner, for any other purpose.
If copying or transmitting this document to another, please copy or
transmit it in its entirety.