Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 10GX13 Multi-Conductor - Enhanced Category 6A Nonbonded-Pair Cable For more Information please call 1-800-Belden1 General Description: CAT6A (625MHz), 4-Pair, U/UTP-Unshielded, Plenum-CMP, Premise Horizontal Cable, 23 AWG Solid Bare Copper Conductors, FEP Insulation, Patented Double-H Spline, Ripcord, Flamarrest(R) Jacket Usage (Overall) Suitable Applications: Premise Horizontal Cable, 10 Gigabit Ethernet, 100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM, NTSC/PAL Component or Composite Video, AES/EBU Digital Audio, AES51, RS-422, Noisy Environments, PoE Physical Characteristics (Overall) Conductor AWG: # Pairs AWG Stranding Conductor Material 4 23 Solid BC - Bare Copper Total Number of Conductors: 8 Insulation Insulation Material: Insulation Material FEP - Fluorinated Ethylene Propylene Outer Jacket Outer Jacket Material: Outer Jacket Trade Name Outer Jacket Material Flamarrest(R) PVC - Polyvinyl Chloride Outer Jacket Ripcord: Yes Overall Cable Overall Cabling Separator Material: Patented RoundFleX - Double H Cross-Web Overall Nominal Diameter: 7.493 mm Pair Pair Color Code Chart: Number Color 1 White/Blue Stripe & Blue 2 White/Orange Stripe & Orange 3 White/Green Stripe & Green 4 White/Brown Stripe & Brown Mechanical Characteristics (Overall) Storage Temperature Range: -20C To +75C Installation Temperature Range: +5C To +50C Operating Temperature Range: -20C To +60C Bulk Cable Weight: 56.552 Kg/Km Max. Recommended Pulling Tension: 177.928 N Min. Bend Radius/Minor Axis: 30.480 mm Min. Bend/Installation: 76.200 mm Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CMP CEC/C(UL) Specification: CMP EU Directive 2011/65/EU (ROHS II): Yes Other Standards: ISO/IEC 11801 ed 2.1 (2008) Class EA Page 1 of 4 01-09-2015 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 10GX13 Multi-Conductor - Enhanced Category 6A Nonbonded-Pair Cable EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Telecommunications Standards: Category 6A - TIA 568.C.2 Applicable Patents: Country www.belden.com/p Flame Test UL Flame Test: NFPA 262 Plenum Flame Test (UL910)(FT6) C(UL) Flame Test: FT6 CSA Flame Test: FT6 Suitability Suitability - Outdoor: No Sunlight Resistance: No Plenum/Non-Plenum Plenum (Y/N): Yes Non-Plenum Number: 10GX12 Electrical Characteristics (Overall) Nom. Mutual Capacitance: Capacitance (pF/m) 55.777 Maximum Capacitance Unbalance (pF/100 m): 50 Nominal Velocity of Propagation: VP (%) 68.000 Maximum Delay: Delay (ns/100 m) 537 @ 100MHz Typical Delay Skew: Delay Skew (ns/m) 114.835 Max. Delay Skew: Delay Skew (ns/100 m) 45 Maximum Conductor DC Resistance: DCR @ 20C (Ohm/100 m) 7.400 Max. Operating Voltage - UL: Voltage 300 V RMS Maximum DCR Unbalanced: DCR Unbalance @ 20C (%) 3.000 Electrical Characteristics-Premise (Overall) Premise Cable Electrical Table 1: Freq. (MHz) Max. Attenuation (dB/100 m) Min. PSNEXT (dB) Min. PSACR (dB) Min RL (dB) 1 2.100 73.3 71.2 20.000 4 3.800 64.3 60.5 23.000 8 5.300 59.8 54.4 24.500 10 5.900 58.3 52.4 25.000 16 7.500 55.2 47.8 25.000 Page 2 of 4 01-09-2015 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 10GX13 Multi-Conductor - Enhanced Category 6A Nonbonded-Pair Cable 20 8.400 53.8 45.4 25.000 25 9.400 52.3 43 24.300 31.25 10.500 50.9 40.4 23.600 62.5 15.000 46.4 31.4 21.500 100 19.100 43.3 24.2 20.100 200 27.600 38.8 11.2 18.000 250 31.100 37.3 6.3 17.300 300 34.300 36.1 1.9 16.800 350 37.200 35.1 16.300 400 40.100 34.3 15.900 450 42.700 33.5 15.500 500 45.300 32.8 15.200 550 47.700 32.2 14.900 600 50.100 31.6 14.700 625 51.200 31.4 14.500 750 56.700 30.2 14.000 860 61.200 29.3 13.600 Premise Cable Electrical Table 2: Freq. (MHz) Input (Unfitted) Imp. (Ohms) Fitted Impedance Min. PSACRF (dB) 1 100+/- 15 105+/- 10 68.8 4 100+/- 15 100+/- 10 56.8 8 100+/- 15 100+/- 10 50.7 10 100+/- 15 100+/- 10 48.8 16 100+/- 15 100+/- 10 44.7 20 100+/- 15 100+/- 10 42.8 25 100+/- 15 100+/- 10 40.8 31.25 100+/- 15 100+/- 10 38.9 62.5 100+/- 15 100+/- 10 32.9 100 100+/- 15 100+/- 10 28.8 200 100+/- 22 100+/- 10 22.8 250 100+/- 32 100+/- 10 20.8 300 100+/- 32 100+/- 10 19.3 350 100+/- 32 100+/- 10 17.9 400 100+/- 32 100+/- 10 16.8 450 100+/- 32 100+/- 10 15.7 500 100+/- 32 100+/- 10 14.8 550 100+/- 32 100+/- 10 14.0 600 100+/- 32 100+/- 10 13.2 625 100+/- 32 100+/- 10 12.9 750 11.3 860 10.1 Premise Cable Electrical Table 4: Frequency (MHz) Min. PSANEXT (dB) Min. PSAACRF (dB) Min. TCL (dB) Min. ELTCTL (dB) 1.000 67.000 67.000 40.000 35.000 4.000 67.000 67.000 40.000 23.000 8.000 67.000 61.100 40.000 16.900 10.000 67.000 59.200 40.000 15.000 16.000 67.000 55.100 38.000 10.900 20.000 67.000 53.200 37.000 9.000 25.000 67.000 51.200 32.000 7.000 31.250 67.000 49.300 35.100 62.500 66.600 43.300 32.000 100.000 63.500 39.200 30.000 200.000 59.000 33.200 27.000 250.000 57.500 31.200 26.000 300.000 56.300 29.700 25.200 350.000 55.300 28.300 24.600 400.000 54.500 27.200 24.000 450.000 53.700 26.100 23.500 500.000 53.000 25.200 23.000 550.000 52.400 24.400 600.000 51.800 23.600 625.000 51.600 23.300 750.000 50.400 21.700 860.000 49.500 20.500 Page 3 of 4 01-09-2015 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 10GX13 Multi-Conductor - Enhanced Category 6A Nonbonded-Pair Cable Notes (Overall) Notes: Jacket sequentially printed every 2 ft/1m. 0.295" cable dimension per TIA 6@1 equivalent diameter. Third party channel verified to TIA/EIA-568-C.2, Category 6a. Put Ups and Colors: Item # Putup Ship Weight Color 10GX13 D151000 1,000 FT 43.000 LB BLUE CAT6A 4PR U/UTP CMP REEL 10GX13 D152500 2,500 FT 115.000 LB BLUE CAT6A 4PR U/UTP CMP REEL 10GX13 0041000 1,000 FT 43.000 LB YELLOW CAT6A 4PR U/UTP CMP REEL 10GX13 0042500 2,500 FT 115.000 LB YELLOW CAT6A 4PR U/UTP CMP REEL 10GX13 0045000 5,000 FT 215.000 LB YELLOW CAT6A 4PR U/UTP CMP REEL 10GX13 0051000 1,000 FT 43.000 LB GREEN, DARK CAT6A 4PR U/UTP CMP REEL 10GX13 0071000 1,000 FT 43.000 LB VIOLET CAT6A 4PR U/UTP CMP REEL 10GX13 0081000 1,000 FT 43.000 LB GRAY CAT6A 4PR U/UTP CMP REEL 10GX13 0091000 1,000 FT 43.000 LB WHITE CAT6A 4PR U/UTP CMP REEL 10GX13 0101000 1,000 FT 43.000 LB BLACK CAT6A 4PR U/UTP CMP REEL 10GX13 0101500 1,500 FT 64.500 BLACK CAT6A 4PR U/UTP CMP REEL Revision Number: 12 Notes Item Desc Revision Date: 02-27-2014 (c) 2015 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 4 of 4 01-09-2015