For more Information
please call
1-800-Belden1
General Description:
CAT6A (625MHz), 4-Pair, U/UTP-Unshielded, Plenum-CMP, Premise Horizontal Cable, 23 AWG Solid
Bare Copper Conductors, FEP Insulation, Patented Double-H Spline, Ripcord, Flamarrest® Jacket
Usage (Overall)
Suitable Applications: Premise Horizontal Cable, 10 Gigabit Ethernet, 100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM,
NTSC/PAL Component or Composite Video, AES/EBU Digital Audio, AES51, RS-422, Noisy
Environments, PoE
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material
423 Solid BC - Bare Copper
Total Number of Conductors: 8
Insulation
Insulation Material:
Insulation Material
FEP - Fluorinated Ethylene Propylene
Outer Jacket
Outer Jacket Material:
Outer Jacket Trade Name Outer Jacket Material
Flamarrest® PVC - Polyvinyl Chloride
Outer Jacket Ripcord: Yes
Overall Cable
Overall Cabling Separator Material: Patented RoundFleX - Double H Cross-Web
Overall Nominal Diameter: 7.493 mm
Pair
Pair Color Code Chart:
Number Color
1White/Blue Stripe & Blue
2White/Orange Stripe & Orange
3White/Green Stripe & Green
4White/Brown Stripe & Brown
Mechanical Characteristics (Overall)
Storage Temperature Range: -20°C To +75°C
Installation Temperature Range: +5°C To +50°C
Operating Temperature Range: -20°C To +60°C
Bulk Cable Weight: 56.552 Kg/Km
Max. Recommended Pulling Tension: 177.928 N
Min. Bend Radius/Minor Axis: 30.480 mm
Min. Bend/Installation: 76.200 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CMP
CEC/C(UL) Specification: CMP
EU Directive 2011/65/EU (ROHS II): Yes
Other Standards: ISO/IEC 11801 ed 2.1 (2008) Class EA
Page 1 of 4 01-09-2015
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
10GX13 Multi-Conductor - Enhanced Category 6A Nonbonded-Pair Cable
EU CE Mark: Yes
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Telecommunications Standards: Category 6A - TIA 568.C.2
Applicable Patents:
Country
www.belden.com/p
Flame Test
UL Flame Test: NFPA 262 Plenum Flame Test (UL910)(FT6)
C(UL) Flame Test: FT6
CSA Flame Test: FT6
Suitability
Suitability - Outdoor: No
Sunlight Resistance: No
Plenum/Non-Plenum
Plenum (Y/N): Yes
Non-Plenum Number: 10GX12
Electrical Characteristics (Overall)
Nom. Mutual Capacitance:
Capacitance (pF/m)
55.777
Maximum Capacitance Unbalance (pF/100 m): 50
Nominal Velocity of Propagation:
VP (%)
68.000
Maximum Delay:
Delay (ns/100 m)
537 @ 100MHz
Typical Delay Skew:
Delay Skew (ns/m)
114.835
Max. Delay Skew:
Delay Skew (ns/100 m)
45
Maximum Conductor DC Resistance:
DCR @ 20°C (Ohm/100 m)
7.400
Max. Operating Voltage - UL:
Voltage
300 V RMS
Maximum DCR Unbalanced:
DCR Unbalance @ 20°C (%)
3.000
Electrical Characteristics-Premise (Overall)
Premise Cable Electrical Table 1:
Freq. (MHz) Max. Attenuation (dB/100 m) Min. PSNEXT (dB) Min. PSACR (dB) Min RL (dB)
12.100 73.3 71.2 20.000
43.800 64.3 60.5 23.000
85.300 59.8 54.4 24.500
10 5.900 58.3 52.4 25.000
16 7.500 55.2 47.8 25.000
Page 2 of 4 01-09-2015
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
10GX13 Multi-Conductor - Enhanced Category 6A Nonbonded-Pair Cable
20 8.400 53.8 45.4 25.000
25 9.400 52.3 43 24.300
31.25 10.500 50.9 40.4 23.600
62.5 15.000 46.4 31.4 21.500
100 19.100 43.3 24.2 20.100
200 27.600 38.8 11.2 18.000
250 31.100 37.3 6.3 17.300
300 34.300 36.1 1.9 16.800
350 37.200 35.1 16.300
400 40.100 34.3 15.900
450 42.700 33.5 15.500
500 45.300 32.8 15.200
550 47.700 32.2 14.900
600 50.100 31.6 14.700
625 51.200 31.4 14.500
750 56.700 30.2 14.000
860 61.200 29.3 13.600
Premise Cable Electrical Table 2:
Freq. (MHz) Input (Unfitted) Imp. (Ohms) Fitted Impedance Min. PSACRF (dB)
1100+/- 15 105+/- 10 68.8
4100+/- 15 100+/- 10 56.8
8100+/- 15 100+/- 10 50.7
10 100+/- 15 100+/- 10 48.8
16 100+/- 15 100+/- 10 44.7
20 100+/- 15 100+/- 10 42.8
25 100+/- 15 100+/- 10 40.8
31.25 100+/- 15 100+/- 10 38.9
62.5 100+/- 15 100+/- 10 32.9
100 100+/- 15 100+/- 10 28.8
200 100+/- 22 100+/- 10 22.8
250 100+/- 32 100+/- 10 20.8
300 100+/- 32 100+/- 10 19.3
350 100+/- 32 100+/- 10 17.9
400 100+/- 32 100+/- 10 16.8
450 100+/- 32 100+/- 10 15.7
500 100+/- 32 100+/- 10 14.8
550 100+/- 32 100+/- 10 14.0
600 100+/- 32 100+/- 10 13.2
625 100+/- 32 100+/- 10 12.9
750 11.3
860 10.1
Premise Cable Electrical Table 4:
Frequency (MHz) Min. PSANEXT (dB) Min. PSAACRF (dB) Min. TCL (dB) Min. ELTCTL (dB)
1.000 67.000 67.000 40.000 35.000
4.000 67.000 67.000 40.000 23.000
8.000 67.000 61.100 40.000 16.900
10.000 67.000 59.200 40.000 15.000
16.000 67.000 55.100 38.000 10.900
20.000 67.000 53.200 37.000 9.000
25.000 67.000 51.200 32.000 7.000
31.250 67.000 49.300 35.100
62.500 66.600 43.300 32.000
100.000 63.500 39.200 30.000
200.000 59.000 33.200 27.000
250.000 57.500 31.200 26.000
300.000 56.300 29.700 25.200
350.000 55.300 28.300 24.600
400.000 54.500 27.200 24.000
450.000 53.700 26.100 23.500
500.000 53.000 25.200 23.000
550.000 52.400 24.400
600.000 51.800 23.600
625.000 51.600 23.300
750.000 50.400 21.700
860.000 49.500 20.500
Page 3 of 4 01-09-2015
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
10GX13 Multi-Conductor - Enhanced Category 6A Nonbonded-Pair Cable
Notes (Overall)
Notes: Jacket sequentially printed every 2 ft/1m. 0.295" cable dimension per TIA 6@1 equivalent diameter. Third party channel verified to TIA/EIA-568-C.2, Category 6a.
Put Ups and Colors:
Item # Putup Ship Weight Color Notes Item Desc
10GX13 D151000 1,000 FT 43.000 LB BLUE CAT6A 4PR U/UTP CMP REEL
10GX13 D152500 2,500 FT 115.000 LB BLUE CAT6A 4PR U/UTP CMP REEL
10GX13 0041000 1,000 FT 43.000 LB YELLOW CAT6A 4PR U/UTP CMP REEL
10GX13 0042500 2,500 FT 115.000 LB YELLOW CAT6A 4PR U/UTP CMP REEL
10GX13 0045000 5,000 FT 215.000 LB YELLOW CAT6A 4PR U/UTP CMP REEL
10GX13 0051000 1,000 FT 43.000 LB GREEN, DARK CAT6A 4PR U/UTP CMP REEL
10GX13 0071000 1,000 FT 43.000 LB VIOLET CAT6A 4PR U/UTP CMP REEL
10GX13 0081000 1,000 FT 43.000 LB GRAY CAT6A 4PR U/UTP CMP REEL
10GX13 0091000 1,000 FT 43.000 LB WHITE CAT6A 4PR U/UTP CMP REEL
10GX13 0101000 1,000 FT 43.000 LB BLACK CAT6A 4PR U/UTP CMP REEL
10GX13 0101500 1,500 FT 64.500 BLACK CAT6A 4PR U/UTP CMP REEL
Revision Number: 12 Revision Date: 02-27-2014
© 2015 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to
change without notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for
any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether
in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities
and in our Distributor’s inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is
correct to the best of Belden’s knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the
safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification.
Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the
product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 4 of 4 01-09-2015
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
10GX13 Multi-Conductor - Enhanced Category 6A Nonbonded-Pair Cable