VS-VSUD400CW60
www.vishay.com Vishay Semiconductors
Revision: 25-Sep-2018 1Document Number: 93117
For technical questions within your region: DiodesAmericas@vishay.com, DiodesAsia@vishay.com, DiodesEurope@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
FRED Pt®,
Ultrafast Soft Recovery Diode Module, 400 A
FEATURES
Ultrafast recovery
UL approved file E222165
Designed for industrial level
Material categorization: for definitions of compliance
please see www.vishay.com/doc?99912
BENEFITS
Reduced RFI and EMI
Higher frequency operation
Reduced snubbing
Reduced parts count
DESCRIPTION / APPLICATIONS
FRED Pt® diodes are optimized to reduce losses and
EMI/RFI in high frequency power conditioning systems. The
softness of the recovery eliminates the need for a snubber in
most applications. These devices are ideally suited for HF
welding, power converters and other applications where
switching losses are significant portion of the total losses.
PRIMARY CHARACTERISTICS
IF(AV) 400 A
VR600 V
Qrr 4730 nC
trr 90 ns
Type Modules - diode, FRED Pt®
Package TO-244
Circuit configuration Two diodes common cathode
Base common
cathode
Lug
terminal
anode 1
Lug
terminal
anode 2
TO-244
ABSOLUTE MAXIMUM RATINGS
PARAMETER SYMBOL TEST CONDITIONS MAX. UNITS
Cathode to anode voltage VR600 V
Continuous forward current per diode IF(AV)
TC = 25 °C 330
A
TC = 85 °C 230
TC = 97 °C 200
Single pulse forward current per diode IFSM TC = 25 °C 2520
Maximum power dissipation PD
TC = 25 °C 660 W
TC = 97 °C 280
Operating junction and storage
temperatures TJ, TStg -40 to +150 °C
ELECTRICAL SPECIFICATIONS PER LEG (TJ = 25 °C unless otherwise specified)
PARAMETER SYMBOL TEST CONDITIONS MIN. TYP. MAX. UNITS
Breakdown voltage VBR IR = 100 μA 600 - -
V
Forward voltage VFM
IF = 200 A - 1.45 2.0
IF = 400 A - 1.67 2.3
IF = 200 A, TJ = 150 °C - 1.13 1.4
IF = 400 A, TJ = 150 °C - 1.39 1.8
Reverse leakage current IRM TJ = 150 °C, VR = VR rated - 0.3 1.38 mA
Series inductance LSFrom top of terminal hole to mounting plane - 5 - nH
VS-VSUD400CW60
www.vishay.com Vishay Semiconductors
Revision: 25-Sep-2018 2Document Number: 93117
For technical questions within your region: DiodesAmericas@vishay.com, DiodesAsia@vishay.com, DiodesEurope@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Fig. 1 - Typical Forward Voltage Drop vs.
Instantaneous Forward Current (Per Leg)
Fig. 2 - Typical Reverse Current vs. Reverse Voltage
(Per Leg)
DYNAMIC RECOVERY CHARACTERISTICS (TJ = 25 °C unless otherwise specified)
PARAMETER SYMBOL TEST CONDITIONS MIN. TYP. MAX. UNITS
Reverse recovery time trr
TJ = 25 °C IF = 200 A,
dIF/dt = 200 A/μs,
VR = 200 V
-90-
ns
TJ = 150 °C - 240 -
Peak recovery current IRRM
IF = 200 A, dIF/dt = 200 A/μs, VR = 200 V - 8.3 - A
IF = 200 A, dIF/dt = 200 A/μs, VR = 200 V, TJ = 150 °C - 24 -
Reverse recovery charge Qrr
IF = 200 A, dIF/dt = 200 A/μs, VR = 200 V - 830 - nC
IF = 200 A, dIF/dt = 200 A/μs, VR = 200 V, TJ = 150 °C - 4730 -
THERMAL - MECHANICAL SPECIFICATIONS
PARAMETER SYMBOL MIN. TYP. MAX. UNITS
Thermal resistance,
junction to case
per leg RthJC - - 0.19
°C/W
per module - - 0.095
Thermal resistance,
case to heatsink RthCS -0.10-
Weight -68- g
-2.4-oz.
Mounting torque 30 (3.4) - 40 (4.6)
lbf · in
(N · m)
Mounting torque center hole 12 (1.4) - 18 (2.1)
Terminal torque 30 (3.4) - 40 (4.6)
Vertical pull --80
lbf · in
2" lever pull --35
Case style TO-244
VF - Forward Voltage Drop (V)
IF - Instantaneous Forward Current (A)
TJ = 25 °C
TJ = 150 °C
1
10
100
1000
0 0.5 1.0 1.5 2.0 2.5
VR - Reverse Voltage (V)
I
R
- Reverse Current (μA)
0.01
0.1
1
10
100
1000
0 100 200 300 400 500 600
25 °C
TJ = 150 °C
VS-VSUD400CW60
www.vishay.com Vishay Semiconductors
Revision: 25-Sep-2018 3Document Number: 93117
For technical questions within your region: DiodesAmericas@vishay.com, DiodesAsia@vishay.com, DiodesEurope@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Fig. 3 - Maximum Current Rating Capability (Per Leg)
Fig. 4 - Forward Power Loss Characteristics
Fig. 5 - Typical Reverse Recovery Time vs.
dIF/dt (Per Leg)
Fig. 6 - Typical Reverse Recovery Charge vs. dIF/dt
(Per Leg)
Fig. 7 - Typical Reverse Recovery Current vs. dIF/dt
(Per Leg)
I
DC
-
Current Rating (A)
Allowable Case Temperature (°C)
0 100 200 300 400
40
0
80
120
160
DC
Square wave (D = 0.50)
rated VR applied
0
50
100
150
200
0 50 100 150 200
DC
D = 0.01
D = 0.02
D = 0.05
D = 0.10
D = 0.20
D = 0.50
Forward Power Loss (W)
Forward Current (A)
RMS Limit
t
rr
(ns)
dI
F
dt (A/μs)
0
100
200
300
100 200 300 400 500
IF = 200 A
Vrr = 200 V
TJ = 25 ˚ C
TJ = 150 ˚ C
Qrr (nC)
dIFdt (A/μs)
0
2000
4000
6000
8000
100 200 300 400 500
IF = 200 A
Vrr = 200 V
TJ = 25 °C
TJ = 150 °C
IRR (A)
dIFdt (A/μs)
0
10
20
30
40
100 200 300 400 500
IF = 200 A
Vrr = 200 V
TJ = 25 ˚ C
TJ = 150 ˚ C
VS-VSUD400CW60
www.vishay.com Vishay Semiconductors
Revision: 25-Sep-2018 4Document Number: 93117
For technical questions within your region: DiodesAmericas@vishay.com, DiodesAsia@vishay.com, DiodesEurope@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Fig. 8 - Reverse Recovery Parameter Test Circuit
ORDERING INFORMATION TABLE
CIRCUIT CONFIGURATION
CIRCUIT CIRCUIT
CONFIGURATION CODE CIRCUIT DRAWING
Two diodes common cathode C
LINKS TO RELATED DOCUMENTS
Dimensions www.vishay.com/doc?95021
IRFP250
D.U.T.
L = 70 μH
V
R
= 200 V
0.01 Ω
G
D
S
dIF/dt
adjust
1- Vishay Semiconductors product
2- UD = FRED Pt®
3- Current rating (400 = 400 A)
4
5
- Circuit configuration:
6
-W = TO-244 wire bondable not insulated
- Voltage rating (60 = 600 V)
C = two diodes common cathode
Device code
51 32 4 6
VS-VS UD 400 C W 60
Base common
cathode
Lug
terminal
anode 2
Lug
terminal
anode 1
Outline Dimensions
www.vishay.com Vishay Semiconductors
Revision: 24-Apr-15 1Document Number: 95021
For technical questions within your region: DiodesAmericas@vishay.com, DiodesAsia@vishay.com, DiodesEurope@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
TO-244
DIMENSIONS in millimeters (inches)
3
2
3
1
Ø 5.2 (Ø 0.20)
9.6 (0.37) MIN.
93 (3.66) MAX.
¼" - 20 UNC
80 (3.15)
40 (1.57)
13 (0.51)
35 (1.37) REF.
7 (0.27)
6 (0.23)
17.5 (0.69)
16.5 (0.65)
21 (0.82)
20 (0.78)
Ø 7.2 (Ø 0.28)
(2 places)
12.6 (0.5)
Legal Disclaimer Notice
www.vishay.com Vishay
Revision: 08-Feb-17 1Document Number: 91000
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of
typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding
statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a
particular product with the properties described in the product specification is suitable for use in a particular application.
Parameters provided in datasheets and / or specifications may vary in different applications and performance may vary over
time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk.
Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for
such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document
or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
© 2017 VISHAY INTERTECHNOLOGY, INC. ALL RIGHTS RESERVED
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Vishay:
VS-VSUD400CW60 IRUD400CW60 VS-VSUD400CW20