Product: 19115
Portable Cordage, 2 C #18 Str BC, Rubber Ins, UL Type SP-1
Product Description
Portable Cordage, 2 Conductor 18AWG (41x34) Bare Copper, Rubber Insulation, UL Type SP-1
Technical Specifications
Physical Characteristics (Overall)
Conductor
AWG Stranding Material Nominal Diameter No. of Conductors
18 41x34 BC - Bare Copper 0.035 in 2
Conductor Count: 2
Insulation
Material Nominal Wall Thickness
SBR - Styrene Butadiene Rubber 0.035 in
Outer Shield Material
Material
No Shield
Outer Jacket Material
Nominal Diameter Separator Material
0.123 x 0.227 in Cotton Serve
Construction and Dimensions
Type of Cordage: SP-1
Electrical Characteristics
Current
Max. Recommended Current [A]
10 Amps per Conductor at 25ºC (7 Amps over 50 ft)
7 Amps per Conductor at 25ºC (over 50 ft)
Voltage
Dielectric Withstand Voltage UL Voltage Rating
1500 V Applied for 1 Min. 300 V RMS
Electrical Characteristics Notes: 1500 V Applied for 1 Min.
Temperature Range
UL Temp Rating: 60°C
Mechanical Characteristics
Bulk Cable Weight: 24 lbs/1000ft
Min Bend Radius/Minor Axis: 1.25 in
Standards
NEC/(UL) Compliance: SP-1
Applicable Environmental and Other Programs
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2003/96/EC (BFR): Yes
EU Directive 2011/65/EU (ROHS II): Yes
EU Directive 2012/19/EU (WEEE): Yes
EU Directive Compliance: EU Directive 2003/11/EC (BFR)
EU CE Mark: Yes
EU RoHS Compliance Date (yyyy-mm-dd): 2004-01-01
MII Order #39 (China RoHS): Yes
Flammability, LS0H, Toxicity Testing
UL voltage rating: 300 V RMS
Plenum/Non-Plenum
Plenum (Y/N): No
Part Number
Variants
Item # Color Putup Type Length UPC
19115 010250 Black Reel 250 ft 612825126522
Footnote: F - MAY CONTAIN MORE THAN 1 PIECE. MINIMUM LENGTH OF ANY ONE PIECE IS 50'.
History
Update and Revision: Revision Number: 0.162 Revision Date: 03-16-2021
© 2021 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without
notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages
(including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief
at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product
Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and
regulations based on their individual usage of the product.