Raychem Circuit Protection
308 Constitution Drive
Menlo Park, CA 94025-1164
800-227-4856
FAX 800-227-4866
RAYCHEM
Circuit Protection®
PTC Devices
Resettable Fuse
PRODUCT: AGR800S
DOCUMENT: SCD 24645
PCN: 846426
REV LETTER: A
REV DATE: NOVEMBER 2, 2000
PAGE NO.: 1 OF 2
Specification Status: RELEASED
Electrical Rating
Voltage: 16VDC MAX
Insulating Material:
Cured, Flame Retarded Epoxy Polymer
Lead Material:
20 AWG Tin/Lead Plated Copper
(0.8 mm [0.032] nom. diameter)
Marking:
Raychem Logo
and Voltage
Lot Identification
(can be on back)
Part Identification
16
G8
TABLE I. DIMENSIONS:
A B C D E F G
MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MIN MAX
mm::
-- 12.7 16.0 20.9 4.3 5.8 7.6 -- -- 3.0 1.2 -- 5.08
in*: -- (0.50) 0.630 (0.820) (0.17) (0.23) (0.30) -- -- (0.12) (0.05) -- (0.200)
*Rounded off approximation
TABLE II. PERFORMANCE RATINGS:
CURRENT RATINGS TIME TO
TRIP INITIAL
RESISTANCE R1 MAX
1 HR. POST TRIP
RESISTANCE
STANDARD TRIP
RA MAX
TRIPPED-STATE
POWER
DISSIPATION
AMPS
AT 25°C SECONDS
AT 25°C, 40 A OHMS
AT 25°C OHMS
AT 25°C OHMS
AT 25°C WATTS AT
25°C
HOLD
AT
R1 MAX
HOLD
AT
RA MAX
TRIP MAX MIN MAX TYP
8.0 7.6 15.0 5.5 0.0049 0.0113 0.0175 0.0181 3.2
Reference Documents: PS400, PS300 (reference for R1 MAX)
Precedence: This specification takes precedence over documents referenced herein.
Effectivity: Reference documents shall be the issue in effect on the date of invitation for bid.
CAUTION: Operation beyond the rated voltage or current may result in rupture, electrical arcing or flame.
Raychem Circuit Protection
308 Constitution Drive
Menlo Park, CA 94025-1164
800-227-4856
FAX 800-227-4866
RAYCHEM
Circuit Protection®
PTC Devices
Resettable Fuse
PRODUCT: AGR800S
DOCUMENT: SCD 24645
PCN: 846426
REV LETTER: A
REV DATE: NOVEMBER 2, 2000
PAGE NO.: 2 OF 2
TABLE III. AUTOMOTIVE SPECIFIC STRESS TESTS AND TEST CONDITIONS:
ELECTRICAL STRESS TESTS
TEST CONDITIONS (see note 2)
ESD Voltage Withstand
(see note 1) 25kV
Short Circuit Fault Current Durability 25 cycles, 16V, 200A
Fault Current Durability
350 cycles, 16V/100A
End-of-life Mode Verification
1750 cycles, 16V/100A
Jump Start Endurance
(see note 1) 3 cycles, 26V, 1 minute duration
Load Dump Endurance
(see note 1) 10 cycles, 86.5V
Note 1: The PolySwitch devices are tested in series with a load resistance and the voltages specified in the test conditions are
shared between the PolySwitch device and the load resistance as specified in PS400.
Note 2: Please refer to Appendix A of PS400 for the detailed test procedures