I NSTALL ATI ON :
•LEDdriversshallbeinstalledinsideelectricalenclosures •MaxRemoteinstallationdistanceis18ft
•18AWG600V/105Ctinnedstrandcopperlead-wiresarerequiredtouseininstallation •LEDdrivercasesshouldbegrounded
WIRING:
ELECTRICAL SPECIFICATIONS:
•ULandcULRecognized,Class2
•ULOutdoorType1
•ClassAsoundrating
•OverloadProtection
•ApprovedDimmers:
SAFET Y:
•Warranty:5yrsbasedonmaxcasetempof
<75°C;
•Input/OutputIsolation
•FCCTitle47CFRPart15
•SurgeProtection(2KV)
•Open/ShortCircuitProtection
•LEDdriverhasalifeexpectancyof
50,000hoursatTcaseof≤75°C
•LEDdriverhasalifeexpectancyof
100,000hoursatTcaseof≤65°C
Dimensions
Length(L) 4.33"
Width(W) 1.77"
Height(H) 1.1"
Mounting(M) 4.1"
*ACElectronics/ACLEDPowerDesignswarrantstothepurchaserthateachLEDDriverwillbefreefromdefectsinmaterialorwork-
manshipforaperiodof5yearswhenoperatedatmaxcasetempofupto<75°C;whenproperlyinstalledandundernormalconditionsof
use.Seeaceleds.comforcompletewarrantypolicy.
©2015
Revised11/17/2015
3401 Avenue D, Arlington, TX 76011 • 800-375-6355 • www.aceleds.com
Data is based upon tests performed by AC Electronics in a controlled environment and representative performance. Actual performance can vary
depending on operating conditions. Specications are subject to change without notice. All specications are nominal unless otherwise noted.
TRIAC-Dimming
Compatible with both leading edge
and trailing edge dimmers
PHYSICAL:
ConstantCurrentLEDDriver
Model Number
AC-35CT700APT
InputVoltage:120V
InputFrequency:50/60Hz
SideMount/Leads
RoHS
COMPLIANT
LEAD-FREE
Output
Power
Input
Current
Input
Power
Min
PF
(fullload)
Max
THD(full
load)
Output
Voltage
Output
Current
T
case
Max
Min
Starting
Temp
Efciency
UpTo
Dimming
Protocol
TRIAC
Dimming
35W 0.35A@120V 42W >0.90 <20 35-50V 700mA
+/-5% 75˚C 0˚C 83%
120Vac
Normwith
Dimmer
100to1%
Lead Lengths
Black 5.9" Blue 5.9"
White 5.9" Red 5.9"
ACELEDS.COM
DimmerCompatibilityChartonBack
RED