Communication Markets Division 3MTM High Density Cross-Connect Modules STG2000 Series The 3MTM Modules STG2000 Series are insulation displacement connector (IDC) copper crossconnect blocks that can be used in a wide variety of network applications using copper (twisted pair). 3M STG2000 modules can be used at most indoor and outdoor cross-connect and interconnectivity points of the copper wire line serving voice and data, fixed and mobile networks. The 3M STG2000 modules feature 3M IDC technology which offers reliable performance for mechanical wire retention, multiple re-terminations, and environmental protection to gas-tight connection. The modules can connect solid copper conductors in a range of diameters from 26 (0.4 mm) to 20 AWG (0.8 mm) with a maximum insulation sheath of 15 AWG (1.5 mm). 3MTM High Density Cross-Connect Module STG2000 in a 100-pair block configuration Features Benefits Innovative design - quiet front/embedded IDC contacts in plastic casing Non-protruding contacts offer good protection and a long life cycle. May prevent accidental contact or disconnection. Cable with single wire conductors from 26 AWG (0.4 mm) to 20 AWG (0.8 mm) on cable and jumper sides. Multiple re-terminations (as per Telcordia NWT 1195) T-connection possible with two wires in one slot 3M straight IDC technology offers outstanding mechanical, electrical, environmental connection performances. Very compact mounting pitch of 0.63 in./ 16 mm, vertical space between block rows Can be used in applications where density is required (overcrowded MDFs, confined spaces of remote terminals or telecom closets in MDUs). Specific disconnection area for testing, monitoring, disconnection or adding protection to each line Keeps the integrity of the wire connection; look both ways testing capability. Versatile mounting Mounting on a metallic back mount frame to affix on a wall, in an equipment rack or in enclosures. Integrated front mount forward surge protection Enables front facing frame over-voltage and over-current protection to equipment and staff while preserving the density. A full range for different applications The 3MTM High Density Cross-Connect Modules STG2000 offer two different types of IDC circuits. The 3M Disconnection Module STG2 C2 features a normally closed contact that provides a disconnection point between the cable and jumper sides by insertion of a disconnection plug as well as a "look both ways" test point for line measurement and monitoring. The disconnection module can typically be used in the subscriber or network side of frame or cross-connect fields where isolating the line for disconnection and test purposes is necessary. 3MTM Disconnection Module STG2 C2 The 3MTM Switching Module ("normally opened") STG2 02 provides a connection that can only be made by insertion of a test cord, patch cord or a protector. It is typically used as a flexible connection point with patch cords or a safety connection point which allows isolation of the line when the protector is removed. Built for high speed In the critical NEXT (near-end cross-talk) measurement, the 3M STG2000 module typically exceeds -52 dB (decibels) at 30MHz. This equates to high bandwidth now, and reserve bandwidth for future upgrades. The 3M STG2000 module can handle VDSL2 bit rates, enabling service providers to support their customer requirements for high speed applications and quality of service. 3MTM Switching Module STG2 O2 Over-voltage and over-current protection of equipment 3-point protection 5-point protection 3M STG2000 modules can be protected with a heavy-duty 3-electrode/pole gas discharge tube also featuring a fail-safe device. Three-point protectors handle large voltage spikes commonly generated by lightning surges. In case of a lasting surge, the fail-safe device will ground the voltage to earth. 3M STG2000 disconnection and switching modules can also be protected with single pair 5-point protectors that combine a heavyduty 3-electrode/pole gas discharge tube (with a fail-safe device) together with two series elements, that limit the current by increasing their resistance. This feature is achieved by careful selection of the protective elements used and greatly limits the need for maintenance. A wide range of single-pair or multi-pair protection products are available in the 3M STG2000 product line. Lightning is not the only potential cause of damage to network equipment. Direct or indirect contact between power and telecommunications cables, known as power cross, can also pose a threat to equipment and personal safety. There are some basic differences between 3-point and 5-point protection circuits. Three-point protection solutions for the 3M STG2000 modules are available in multi-pair protection magazines, typically 8 or 10 pairs, or single-pair protector modules. Specifications Mechanical Dimensions: Height/Length Width Depth 8-pair block 126.2 mm/4.968 in. 14.0 mm/0.055 in. 50.1 mm/1.972 in. 10-pair block 146.2 mm/5.598 in. 14.0 mm/0.055 in. 50.1 mm/1.972 in. Wire range IDC contacts - solid copper conductor 0.4 mm to 0.8 mm 26 AWG to 20 AWG T-connection/double jumpering possible with different wire gauges Wire re-terminations: 250 re-terminations of 24 AWG per Telcordia TR-NWT-001195 Materials Plastics Thermoplastic Contacts Bronze, tin (Sn) plating Electrical Insulation resistance > 1x1010 Contact resistance < 10 m Dielectric strength 3000 V rms, 60 Hz AC High voltage surge 3000 V DC surge Transmission Insertion loss < 0.01 dB to 2.2 MHz < 0.02 dB to 12 MHz < 0.03 dB to 30 MHz Return loss > 50 dB to 2.2 MHz > 38 dB to 12 MHz > 30 dB to 30 MHz Crosstalk > 73 dB to 2.2 MHz > 60 dB to 12 MHz > 53 dB to 30 MHz 3MTM High Density Cross-Connect Module STG2000 100-pair block with single pair protectors Environmental Telcordia TR-NWT-001195 - 3rd party tested "Generic requirements for Insulation Displacement Connector (IDC) crossconnect terminal blocks" Operating temperature range -40C to 70C Storage temperature range -40C to 90C Flammability rating UL 94 V-0 materials used RoHS: Compliant with EU RoHS Directive (2011/65/EU)* 3MTM 10-pair Protection Magazine 3MTM High Density Cross-Connect Modules STG2000 Ordering Information Model Number Product Description 3M ID Minimum Order STG2 C2 8 STG2 C2 8 disconnection module 8 pairs (1 to 8 marking) IA340532273 256 STG2 C2 8P STG2 C2 8P disconnection module 8 pairs for 8 pair SOR CH8 protection magazine (1 to 8 marking) IA340502714 256 STG2 C2 10 STG2 C2 10 disconnection module 10 pairs (1 to 0 marking) IA340532265 320 STG2 C2 10 STG2 C2 10 disconnection module 10 pairs (0 to 9 marking) IA340502698 320 STG2 C2 10P STG2 C2 10P disconnection module 10 pairs for 10 pair SOR CH10 protection magazine IA340532257 320 STG2 C2 10PU STG2 C2 10PU disconnection module 10 pairs for SOR PU protectors IA340532281 320 STG2 O2 10PU STG2 O2 10PU switching (normally open) module 10 pairs for SOR PU protectors IA340535037 320 BSTG2 C2 8 96 BSTG2 C2 8 96 disconnection block 96 pairs IA340502706 50 BSTG2 C2 8 128 BSTG2 C2 8 128 disconnection block 128 pairs IA340532232 8 BSTG2 C2 10 BSTG2 C2 10 disconnection block 100 pairs IA340580066 16 BSTG2 C2 10P BSTG2 C2 10P disconnection block 100 pairs for 10 pair SOR CH10 protection magazine IA340580074 16 BSTG2 C2 10PU BSTG2 C2 10PU disconnection block 100 pairs for SOR PU protectors IA340532240 16 BSTG2 O2 10PU BSTG2 O2 10PU switching (normally open) block 100 pairs for SOR PU protectors IA340500601 16 C232280A STG back mount frame - 125 ways - 2 meters - 55mm depth - 16mm pitch - 10 pair FQ100004503 1 set/2 pieces C232281A STG back mount frame - 125 ways - 2 meters - 55mm depth - 16mm pitch - 8pair FQ100004511 1 set/2 pieces C220673B SOR E8 8-pair label holder FQ100004057 20 C220674B SOR E10 10-pair label holder FQ100004065 20 C222950A SOR ER8 8-pair swivelling label holder (box of 10 pieces) FQ100004248 1 C222951A SOR ER10 10-pair swivelling label holder (box of 10 pieces) FQ100004255 1 C222909A SOR FC disconnection plug - red FQ100004156 10 bags/100 pieces C222903A STG SOR PE 3 digits (bag of 100 pieces) FQ100004149 10 C222014B SOR TB 4-wire test probe FQ100026845 5 C234056A SOR OC SI-S termination tool FQ100029781 10 234058CA SOR OC PKSI-S termination tool FQ100030532 10 234062CA SOR OC QPKSI-S termination tool FQ100030573 10 234062CA Set of 10 spare blades FQ100027595 1 C233726B SOR CH protection magazine 10-pair w/o arresters FQ100004537 20 C233728B SOR CH protection magazine 10-pair w/o arresters w/earth cord FQ100004552 400 C233740B SOR CH protection magazine 10-pair w/250V arresters FQ100004578 400 C231039A 3-POLE 250V arrester w/fail-safe for SOR CH protection magazine FQ100027579 500 C233803A SPPM SORPU7 230V GDT w/PTCRS IA340513653 1000 233808CA SPPM SORPU8 230V GDT IA340513661 1000 "RoHS 2011/65/EU" means that the product or part does not contain any of the substances in excess of the maximum concentration values ("MCVs") in EU RoHS Directive 2011/65/EU. The MCVs are by weight in homogeneous materials. This information represents 3M's knowledge and belief, which may be based in whole or in part on information provided by third party suppliers to 3M. 3M is a trademark of 3M Company. Important Notice All statements, technical information, and recommendations related to 3M's products are based on information believed to be reliable, but the accuracy or completeness is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Any statements related to the product which are not contained in 3M's current publications, or any contrary statements contained on your purchase order shall have no force or effect unless expressly agreed upon, in writing, by an authorized officer of 3M. Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture for a period of 12 months from the time of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M's option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any loss or damage arising from this 3M product, whether direct, indirect, special, incidental or consequential regardless of the legal theory asserted. Communication Markets Division 6801 River Place Blvd. Austin, TX 78726-9000 USA Phone 1-800-426-8688 Fax 1-800-626-0329 Web 3M.com/Telecom Please recycle. Printed in USA (c) 3M 2016. All rights reserved. 80-6113-2882-6