Digital Counter (DIN 72 x 72) H7AN CSM_H7AN_DS_E_4_1 A DIN 72 x 72 mm Best-selling Counter * Easy setting with thumbwheel switches. * A draw-out construction enables maintenance without rewiring. * Models with 2-, 4-, 6-, or 8-digit displays are also available. * Total Counter models are also Available. * Complies with UL and CSA Marking. Refer to Safety Precautions for All Counters and Safety Precautions on page 17. This product was upgraded in January 2006. Refer to Changes in Specifications on page 18 for details. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. 1 H7AN Ordering Information Each model is sold together with a mounting bracket. Preset Counter Incrementing (Up) or decrementing (Down) counter (not reversible) One stage Reversible counter (Up/Down) One stage Two stages With digital display Two stages With digital display With digital display With digital display No. of Backup digits function No. of Backup digits function No H7AN-2D --- Yes H7AN-2DM --- No H7AN-4D H7AN-W4D Yes H7AN-4DM H7AN-W4DM No H7AN-E2D --- Yes H7AN-E2DM --- No H7AN-E4D H7AN-WE4D Yes --- H7AN-WE4DM 2 2 4 4 Incrementing (Up), decrementing (Down), or reversible (Up/Down) counter One stage Two stages With digital display With digital display No. of Backup digits function 6 8 No H7AN-R6D H7AN-RW6D Yes H7AN-R6DM H7AN-RW6DM No H7AN-R8D --- Yes H7AN-R8DM --- Totalizing Counter Incrementing (Up) or decrementing (Down) counter (not reversible) Reversible counter (Up/Down) No. of Backup digits function No. of Backup digits function No 4 Yes Reversible counter (Up/Down) H7AN-T4 H7AN-T4M H7AN-ET4 H7AN-ET4M 6 8 No H7AN-RT6 Yes H7AN-RT6M No --- Yes H7AN-RT8M Note: Specify the power supply voltage when ordering. 2 H7AN Specifications Preset Counters Incrementing/Decrementing Counters Operating method Incrementing and decrementing (selectable with DIP switch) Mounting method Flush mounting Operation modes N, F, C, R, K, P, Q (selectable with rotary DIP switch) Input signal method (Count and reset Contact and transistor input voltage (H and L) inputs) Control output 1-stage counters: Contact (SPDT) and transistor output (H and L output switchable) 2-stage counters: Contact (SPST-NO) and transistor output (H and L output switchable) Set value read Continuous mode Memory backup No Yes/No (Selectable using DIP switch) Display Yes (10-mm high 7-segment LED, Up indicator) Yes (10-mm high 7-segment LED, Up indicator) H7AN-2DM Models 2 digits 1 stage H7AN-2D 4 digits 1 stage H7AN-4D H7AN-4DM 2 stages H7AN-W4D H7AN-W4DM Reversible Counters Operating method Reversible (selectable with rotary DIP switch) between 0 and the set value Incrementing/decrementing A/D (command inputs) Incrementing/decrementing B/E (individual inputs) Incrementing/decrementing C/F (phase difference inputs) Mounting method Flush mounting Operation modes N, F, C, R, K, P, Q (selectable with rotary DIP switch) Input signal method (Count, reset input) Contact and transistor input voltage (H and L) Control output 1-stage counters: Contact (SPDT) and transistor output (H and L output switchable) 2-stage counters: Contact (SPST-NO) and transistor output (H and L output switchable) Set value read Continuous mode Memory backup No Display Yes (10-mm high 7-segment LED, Up indicator) Models Yes/No (Selectable using DIP switch) 2 digits 1 stage H7AN-E2D 4 digits 1 stage H7AN-E4D H7AN-E2DM H7AN-E4DM 2 stages H7AN-WE4D H7AN-WE4DM Incrementing, Decrementing, and Reversible Counters Operating method Incrementing, decrementing, and reversible (UP/DOWN A to F) (selectable with rotary DIP switch) Mounting method Flush mounting Operation modes N, F, C, R, K, P, Q (selectable with rotary DIP switch) Input signal method (Count, reset input) Contact and transistor input voltage (H and L) Control output 1-stage counters: Contact (SPDT) and transistor output (H and L output switchable) 2-stage counters: Contact (SPST-NO) and transistor output (H and L output switchable) Set value read Continuous mode, Reset mode (selectable) Memory backup No Display Yes (8-mm high 7-segment LED, Up indicator) Models 6 digits 8 digits Yes/No (Selectable using DIP switch) 1 stage H7AN-R6D H7AN-R6DM 2 stage H7AN-RW6D H7AN-RW6DM 1 stages H7AN-R8D H7AN-R8DM 3 H7AN Totalizing Counters Incrementing/Decrementing Counters Operating method Incrementing and decrementing (selectable with DIP switch) Mounting method Flush mounting Input signal method (Count, reset input) Contact and transistor input voltage (H and L) Memory backup No Display Yes (10-mm high 7-segment LED) Models 4 digits H7AN-T4 Yes/No (Selectable using DIP switch) H7AN-T4M Reversible Counters Operating method Reversible (selectable with rotary DIP switch) between 0 and the full scale Incrementing/decrementing A/D (command inputs) Incrementing/decrementing B/E (individual inputs) Incrementing/decrementing C/F (phase difference inputs) Mounting method Flush mounting Input signal method (Count, reset input) Contact and transistor input voltage (H and L) Memory backup Yes/No (Selectable using DIP switch) Display Models Yes (10-mm high 7-segment LED) 4 digits H7AN-ET4M Incrementing, Decrementing, and Reversible Counters Operating method Incrementing, decrementing, and reversible (UP/DOWN A to F) Mounting method Flush mounting Input signal method (Count, reset input) Contact and transistor input voltage (H and L) Memory backup No Display Yes (8-mm high 7-segment LED) Models Yes/No (Selectable using DIP switch) 6 digits H7AN-RT6 H7AN-RT6M 8 digits --- H7AN-RT8M Ratings Rated supply voltage 100 to 240 VAC, 50/60 Hz (common use); 12 to 24, 48, 100 VDC* Operating voltage range 85% to 110% of rated voltage Power consumption Approx. 10 VA (240 VAC at 50 Hz); Approx. 5 W (at 24 VDC)** Max. counting speed of CP1 and CP2 2-digit counters: 30 Hz 4-digit counters: 30 Hz or 5 kHz 6- or 8-digit counters: 30 Hz or 5 kHz Minimum signal width (with ON/OFF ratio of 1:1): 30 Hz: 16.7 ms, 5 kHz: 0.1 ms H: 4.5 to 30 VDC, L: 0 to 2 VDC Reset Power supply reset (except for H7AN Counter with suffix "-M"): Minimum power-OFF time: 0.5 s with a reset time of 0.05 s after power-ON. External, manual, reset signal time: 0.02 s Reset time after completion of reset signal: 0.05 s Automatic reset*** Control output Contacts: 3 A at 250 VAC, resistive load (cos = 1) No-contacts: 100 mA max. at 30 VDC max., open collector Min. applicable load 10 mA at 5 VDC (p level reference value) External power supply 80 mA, 12 VDC 10% (contains 5% ripple max.) Ambient temperature Operating: -10C to 55C (with no icing) Storage: -25C to 65C (with no icing) Ambient humidity 35% to 85% Case color Light gray (Munsell 5Y7/1) *The ripple is 20% max. **There is an inrush current of 14 A at 240 VAC for approximately 0.6 ms, 15 A at 12 to 24 VDC for 2 ms, 5 A at 48 VDC for 3 ms, or 8 A at 100 VDC for 2 ms immediately after power-ON. ***Only preset counters can be automatically reset. 4 H7AN Characteristics Insulation resistance 100 MW min. (at 500 VDC) (between current-carrying terminal and exposed non-current-carrying metal parts, and between non-continuous contacts) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min (between current-carrying terminal and exposed non-current carrying metal parts) 750 VAC, 50/60 Hz for 1 min (between non-continuous contacts) Impulse withstand voltage 6 kV (between power terminals), 6 kV (between current-carrying terminal and exposed non-current-carrying metal parts) Noise immunity 2 kV (between power terminals) and 500 V (between input terminals), square-wave noise by noise simulator Vibration resistance Destruction:10 to 55 Hz, 0.75-mm double amplitude Malfunction:10 to 55 Hz, 0.5-mm double amplitude Shock resistance Destruction: 300 m/s2 Malfunction: 100 m/s2 Life expectancy Mechanical: 10,000,000 operations min. Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load) Approved standards UL508, CSA C22.2 No.14 Weight Approx. 360 g Engineering Data Life of Contacts 30 VDC (cos = 1) 250 VAC (cos = 1) Load current (A) Electric Life Expectancy (Inductive load) No. of operations (x103) No. of operations (x103) Electric Life Expectancy (Resistive load) 30 VDC (L/R=7ms) Reference: 0.15 A max. can be switched 100,000 times at 125 VDC (cos = 1). 0.1 A max. can be switched 100,000 times when L/R = 7 ms. 250 VAC (cos = 0.4) Load current (A) 5 H7AN Operation Count Operation Preset Counters Incrementing/Decrementing selectable mode Incrementing mode Reversible mode Incrementing/Decrementing A, B, C (incrementing) mode Reset Reset 2nd 2nd Preset Preset 1st 1st Display Display 0 1st 0 Count out Count out 1st Control outputs Control outputs Count out 2nd Count out 2nd Decrementing mode Incrementing/Decrementing D, E, F (decrementing) mode Reset Reset 2nd 2nd Preset Preset Display Display 1st 1st 0 0 Count out 1st 1st Control outputs 2nd Count out Control outputs Count out Count out 2nd Note: Two-stage counters, set the counters so that the interval between 1st and 2nd count out will be more than 5 ms. For Incrementing/ Decrementing switchable counters, only the 2nd value will be effective if the 1st value is larger than the 2nd value. The Incrementing/Decrementing Counters give outputs in the following order; 1st to 2nd to 1st to 2nd. Totalizing Counters Incrementing/Decrementing selectable mode Incrementing mode Reversible mode Incrementing/Decrementing A, B, C (decrementing) mode Reset Reset Full scale* Full scale* Display Display 0 Decrementing mode 0 Incrementing/Decrementing D, E, F (decrementing) mode Reset Full scale* Display Reset Full scale* Display 0 0 Note: The count value will return to "0" when it reaches the full scale limit. * The full scale value is 9999 for the 4-digit counters, 999999 for the 6-digit counters, and 99999999 for the 8-digit counters. 6 H7AN *Output Timing Charts 1-stage Counters 2-stage Counters Start 1st stage: count out Count out Count Count ON ON OFF Contact output 2nd stage: count out Start OFF Load Load ON Transistor output ON Contact outputs OFF OFF Load Phase (H to L) ON OFF Loads OFF Phase (L to H) * OFF Phase (H to L) ON * The operation of the load when the phase has been reversed. Loads OFF Phase (L to H) * ON Transistor outputs OFF Phase (H to L) ON Loads OFF Phase (L to H) * * The operation of the load when the phase has been reversed. Output Delays Control output Max. counting speed Output delay 2-, 4-digit counters Contact output 30 Hz Transistor output 14.0 to 16.0 ms 6-, 8-digit counters 14.0 to 18.0 ms 5 kHz 6.0 to 8.0 ms 6.0 to 8.0 ms 30 Hz 8.0 to 10.0 ms 9.5 to 12.0 ms 5 kHz 0.4 to 0.6 ms 0.3 to 0.5 ms Input Mode Setting Incrementing/Decrementing Selectable Mode Note: The width of (A) must be the same as or lager than the minimum signal width, because an error of 1 count may occur if the width of (A) is smaller than the minimum signal width. Incrementing mode Decrementing mode CP1: Count input; CP2: prohibit (gate) input CP1: Count input; CP2: prohibit (gate) input CP1 CP2 H L CP1 (A) Prohibited (A) H CP2 L H L (A) Prohibited H L n 5 n-1 4 Count (A) n-2 Count 3 2 n-3 n-4 1 0 0 CP1: Prohibit (gate) input; CP2: count input CP1: Prohibit (gate) input; CP2: count input CP1 CP2 H CP1 L (A) Prohibited H H L CP2 H 3 n n-1 Count 2 n-2 n-3 n-4 1 0 (A) L 5 4 Count (A) Prohibited (A) L 0 n-5 0 0 n-5 7 H7AN Reversible Mode Note: 1. A: Minimum signal width; B: Must be at least 1/2 of minimum signal width. An error of 1 count may occur if the width of (A) and (B) are smaller than the minimum signal width. 2. Set the same counting speed for CP1 and CP2 when in Up/Down C, or F mode. Incrementing mode Decrementing mode Incrementing/Decrementing A command input mode CP1 (A) 0 H L H H n-1 n-2 n-3 0 n-3 (A) CP2 L L 3 3 2 2 1 Count n n-1 2 1 1 0 0 0 Incrementing/Decrementing C phase difference input mode H n-1 n-1 n-2 n-2 n-2 n-3 0 n-3 Incrementing/Decrementing F phase difference input mode CP1 L H L BB BB BBB B H CP2 L Count 3 3 2 2 H L Count 2 1 1 0 n-2 H CP1 L Count CP2 n-2 Incrementing/Decrementing E individual input mode Incrementing/Decrementing B individual input mode CP1 n-1 1 0 0 n 2 2 2 L Count 3 3 (A) H CP2 L 1 CP2 L (A) H Count CP1 H CP1 L (A) CP2 Incrementing/Decrementing D command input mode H 0 0 n n-1 n-2 n-2 n-3 n-1 n-2 n-3 Output Modes Incrementing, decrementing, or reversible One-shot 1st output (0.5 s, fixed) Self-holding output Self-holding output Only CP2 is effective for 1-stage digital counters. One-shot 2nd output (0.1 to 1 s, variable) Note: 1. In the C, K, P, and Q modes, the counters must not count out again while the one-shot timer is working. 2. In the C mode, the present value is placed in reset start status as soon as the preset count is reached and the count-out status is not displayed. Output mode N Incrementing, Incrementing/Decrementing A, B, C Reset 2nd Display 1st 0 Decrementing, Incrementing/Decrementing D, E, F Reset 2nd Display 1st 0 1st output 1st output 2nd output 2nd output 8 H7AN Output mode F Incrementing, Incrementing/Decrementing A, B, C Reset 2nd Display 1st 0 C 2nd output 2nd output Reset Reset 2nd Display 1st 0 1st output 1st output 2nd output 2nd output Reset 2nd Display 1st 0 Reset 2nd Display 1st 0 1st output 1st output 2nd output 2nd output Reset 2nd Display 1st 0 P 2nd Display 1st 0 1st output Display 1st 0 K Reset 1st output 2nd R Decrementing, Incrementing/Decrementing D, E, F Reset 2nd Display1st 0 1st output 1st output 2nd output 2nd output Reset Reset Q 2nd Display 1st 0 2nd Display 1st 1st output 1st output 2nd output 2nd output Reset 2nd Display 1st 0 0 Reset 2nd Display 1st 0 1st output 1st output 2nd output 2nd output 9 H7AN Nomenclature Nomenclature Preset Counter H7AN-2D, -2DM H7AN-E2D, -E2DM H7AN-4D, -4DM H7AN-E4D, -E4DM Seven-segment LED digital display Seven-segment LED digital display Indicator lights at count-out Indicator lights at count-out Indicator lights when reset input is received Indicator lights when reset input is received Pushbutton switch for manual reset Pushbutton switch for manual reset Internal Unit mounting screw One-shot timer adjuster Internal Unit mounting screw One-shot timer adjuster Front cover Front cover Arrangement and Functions of Specification Selection Switches H7AN-2D (Counting speed: 30 Hz only) H7AN-E2D Arrangement and Functions of Specification Selection Switches (Counting speed: 30 Hz only) 1 2 3 SW4 H7AN-4D 1 2 SW4 SW2 H7AN-E4D 1 2 SW3 SW1 SW2 SW2: (A) Operating mode selector SW4-1: Output phase selector for transistor output section LH (at count-out) (See note.) HL (at count-out) Manual reset possible (See note.) Manual reset not possible LH (at count-out) (See note.) HL (at count-out) Manual reset possible (See note.) Manual reset not possible Up counting (incrementing) (See note.) Down counting (decrementing) 30 Hz (See note.) 5 kHz SW3-2: CP2 maximum counting speed selector 30 Hz (See note.) 5 kHz SW4-1: Output phase selector for transistor output section LH (at count-out) (See note.) HL (at count-out) SW4-2: Manual reset selector Manual reset possible (See note.) Manual reset not possible SW4-3: UP/DOWN selector Up counting (incrementing) (See note.) Down counting (decrementing) H7AN-2DM (Counting speed: 30 Hz only) 1 SW3 H7AN-E2DM (Counting speed: 30 Hz only) 1 2 3 SW4 1 SW3 SW2 SW2: SW3: (A) Operating mode selector Power failure memory backup Memory backup (See note.) No memory backup SW4-1: Output phase selector for transistor output section LH (at count-out) (See note.) HL (at count-out) SW4-2: Manual reset selector Manual reset possible (See note.) Manual reset not possible SW4-3: UP/DOWN selector Up counting (incrementing) (See note.) Down counting (decrementing) 1 2 SW4 SW1 SW2 SW1: SW2: SW3: (A) Counting function selector (A) Operating mode selector Power failure memory backup Memory backup (See note.) No memory backup SW4-1: Output phase selector for transistor output section LH (at count-out) (See note.) HL (at count-out) SW4-2: Manual reset selector Manual reset possible (See note.) Manual reset not possible 1 2 SW4 SW1 SW2 SW2: (A) Operating mode selector SW3-1: CP1 maximum counting speed selector SW4-2: Manual reset selector SW4-3: UP/DOWN selector 1 2 SW3 SW2 SW1: (A) Counting function selector SW2: (A) Operating mode selector SW4-1: Output phase selector for transistor output section SW4-2: Manual reset selector 1 2 3 SW4 H7AN-4DM SW1: (A) Counting function selector SW2: (A) Operating mode selector SW3-1: CP1 maximum counting speed selector 30 Hz (See note.) 5 kHz SW3-2: CP2 maximum counting speed selector 30 Hz (See note.) 5 kHz SW4-1: Output phase selector for transistor output section LH (at count-out) (See note.) HL (at count-out) SW4-2: Manual reset selector Manual reset possible (See note.) Manual reset not possible H7AN-E4DM 1 2 3 SW3 1 2 3 SW4 SW2 SW2: (A) Operating mode selector SW3-1: CP1 maximum counting speed selector 30 Hz (See note.) 5 kHz SW3-2: CP2 maximum counting speed selector 30 Hz (See note.) 5 kHz SW3-3: SW3-3: Power failure memory backup Memory backup (See note.) No memory backup SW4-1: Output phase selector for transistor output section LH (at count-out) (See note.) HL (at count-out) SW4-2: Manual reset selector Manual reset possible (See note.) Manual reset not possible SW4-3: UP/DOWN selector Up counting (incrementing) (See note.) Down counting (decrementing) 1 2 3 SW3 1 2 SW4 SW1 SW2 SW1: (A) Counting function selector SW2: (A) Operating mode selector SW3-1: CP1 maximum counting speed selector 30 Hz (See note.) 5 kHz SW3-2: CP2 maximum counting speed selector 30 Hz (See note.) 5 kHz SW3-3: Power failure memory backup Memory backup (See note.) No memory backup SW4-1: Output phase selector for transistor output section LH (at count-out) (See note.) HL (at count-out) SW4-2: Manual reset selector Manual reset possible (See note.) Manual reset not possible Note: These settings are the defaults for the specification selection switches. 10 H7AN H7AN-W4D, -W4DM H7AN-WE4D, -WE4DM H7AN-R6D, -R6DM H7AN-R8D, -R8DM Seven-segment LED digital display Seven-segment LED digital display Indicator lights at count-out Indicator lights at count-out Indicator lights when reset input is received Internal Unit mounting screw One-shot timer adjuster Indicator lights when reset input is received Pushbutton switch for manual reset Internal Unit mounting screw One-shot timer adjuster Indicator lights at count-out Indicator lights when reset input is received Pushbutton switch for manual reset Internal Unit mounting screw One-shot timer adjuster Front cover Front cover Front cover Pushbutton switch for manual reset Arrangement and Functions of Specification Selection Switches H7AN-W4D Arrangement and Functions of Specification Selection Switches H7AN-R6D, -R8D H7AN-WE4D 1 2 SW3 1 2 3 4 SW4 1 2 SW3 SW2 1 2 3 SW4 SW1 SW2 SW2: (B) Operating mode selector SW3-1: CP1 maximum counting speed selector 30 Hz (See note.) 5 kHz SW3-2: CP2 maximum counting speed selector 30 Hz (See note.) 5 kHz SW4-1: Output phase selector for first transistor output section LH (at count-out) (See note.) HL (at count-out) SW4-2: Output phase selector for second transistor output section LH (at count-out) (See note.) HL (at count-out) SW4-3: Manual reset selector Manual reset possible (See note.) Manual reset not possible SW4-4: UP/DOWN selector Up counting (incrementing) (See note.) Down counting (decrementing) H7AN-W4DM 1 2 3 4 SW4 SW2 SW2: (B) Operating mode selector SW3-1: CP1 maximum counting speed selector 30 Hz (See note.) 5 kHz SW3-2: CP2 maximum counting speed selector 30 Hz (See note.) 5 kHz SW3-3: Power failure memory backup Memory backup (See note.) No memory backup SW4-1: Output phase selector for first transistor output section LH (at count-out) (See note.) HL (at count-out) SW4-2: Output phase selector for second transistor output section LH (at count-out) (See note.) HL (at count-out) SW4-3: Manual reset selector Manual reset possible (See note.) Manual reset not possible SW4-4: UP/DOWN selector Up counting (incrementing) (See note.) Down counting (decrementing) 1 2 3 SW4 SW1 SW2 SW1: (A) Counting function selector SW2: (B) Operating mode selector SW3-1: CP1 maximum counting speed selector 30 Hz (See note.) 5 kHz SW3-2: CP2 maximum counting speed selector 30 Hz (See note.) 5 kHz SW4-1: Output phase selector for first transistor output section LH (at count-out) (See note.) HL (at count-out) SW4-2: Output phase selector for second transistor output section LH (at count-out) (See note.) HL (at count-out) SW4-3: Manual reset selector Manual reset possible (See note.) Manual reset not possible SW1: (B) Counting function selector SW2: (A) Operating mode selector SW3-1: CP1 maximum counting speed selector 30 Hz (See note.) 5 kHz SW3-2: CP2 maximum counting speed selector 30 Hz (See note.) 5 kHz SW4-1: Output phase selector for transistor output section LH (at count-out) (See note.) HL (at count-out) SW4-2: Set value read selector Always read (See note.) Read only at reset SW4-3: Manual reset selector Manual reset possible (See note.) Manual reset not possible H7AN-R6DM, -R8DM H7AN-WE4DM 1 2 3 SW3 1 2 SW3 1 2 3 SW3 1 2 3 SW4 SW1 SW2 SW1: (A) Counting function selector SW2: (B) Operating mode selector SW3-1: CP1 maximum counting speed selector 30 Hz (See note.) 5 kHz SW3-2: CP2 maximum counting speed selector 30 Hz (See note.) 5 kHz SW3-3: Power failure memory backup Memory backup (See note.) No memory backup SW4-1: Output phase selector for first transistor output section LH (at count-out) (See note.) HL (at count-out) SW4-2: Output phase selector for second transistor output section LH (at count-out) (See note.) HL (at count-out) SW4-3: Manual reset selector Manual reset possible (See note.) Manual reset not possible 1 2 3 SW3 1 2 3 SW4 SW1 SW2 SW1: (B) Counting function selector SW2: (A) Operating mode selector SW3-1: CP1 maximum counting speed selector 30 Hz (See note.) 5 kHz SW3-2: CP2 maximum counting speed selector 30 Hz (See note.) 5 kHz SW3-3: Power failure memory backup Memory backup (See note.) No memory backup SW4-1: Output phase selector for transistor output section LH (at count-out) (See note.) HL (at count-out) SW4-2: Set value read selector Always read (See note.) Read only at reset SW4-3: Manual reset selector Manual reset possible (See note.) Manual reset not possible Note: These settings are the defaults for the specification selection switches. 11 H7AN Totalizing Counter H7AN-RW6D, -RW6DM H7AN-T4, -T4M, -ET4, -ET4M H7AN-RT6, -RT6M, -RT8, -RT8M Seven-segment LED digital display Seven-segment LED digital display Indicator lights at count-out Indicator lights when reset input is received Pushbutton switch for manual reset Internal Unit mounting screw One-shot timer adjuster Indicator lights when reset input is received Front cover Front cover Arrangement and Functions of Specification Selection Switches Pushbutton switch for manual reset Internal Unit mounting screw Arrangement and Functions of Specification Selection Switches H7AN-T4 H7AN-RW6D 1 2 SW3 1 2 3 4 SW4 H7AN-ET4 1 2 SW3 H7AN-RT6, -RT8 1 2 SW4 1 2 SW3 SW1 SW2 1 SW4 1 2 SW3 SW1 SW1: (B) Counting function selector SW2: (B) Operating mode selector SW3-1: CP1 maximum counting speed selector 30 Hz (See note 1.) 5 kHz SW3-1: CP1 maximum counting speed selector 30 Hz (See note 1.) 5 kHz SW3-2: CP2 maximum counting speed selector SW3-2: SW3-2: CP2 maximum counting speed selector 30 Hz (See note 1.) 5 kHz 30 Hz (See note 1.) 5 kHz Manual reset possible (See note 1.) Manual reset not possible SW3-2: CP2 maximum counting speed selector SW1: SW4: Manual reset selector (B) Counting function selector SW3-1: CP1 maximum counting speed selector 30 Hz (See note 1.) 5 kHz SW3-2: CP2 maximum counting speed selector 30 Hz (See note 1.) 5 kHz 30 Hz (See note 1.) 5 kHz SW4: Manual reset selector Manual reset possible (See note 1.) Manual reset not possible Manual reset possible (See note 1.) Manual reset not possible Up counting (incrementing) (See note 1.) Down counting (decrementing) LH (at count-out) (See note 1.) HL (at count-out) (A) Counting function selector 30 Hz (See note 1.) 5 kHz SW4-2: UP/DOWN selector SW4-2: Output phase selector for second transistor output section SW1 SW3-1: CP1 maximum counting speed selector SW4-1: Manual reset selector SW4-1: Output phase selector for first transistor output section LH (at count-out) (See note 1.) HL (at count-out) SW1: 1 SW4 SW4-3: Set value read selector Always read (See note 1.) Read only at reset H7AN-T4M H7AN-ET4M H7AN-RT6M, -RT8M SW4-4: Manual reset selector Manual reset possible (See note 1.) Manual reset not possible 1 2 3 SW3 1 2 SW4 1 2 3 SW3 1 SW4 1 2 3 SW3 SW1 1 SW4 SW1 H7AN-RW6DM 1 2 3 SW3 1 2 3 4 SW4 SW1 SW2 SW3-1: CP1 maximum counting speed selector 30 Hz (See note 1.) 5 kHz SW3-2: CP2 maximum counting speed selector 30 Hz (See note 1.) 5 kHz SW1: (B) Counting function selector SW2: (B) Operating mode selector SW3-1: CP1 maximum counting speed selector 30 Hz (See note 1.) 5 kHz SW3-2: CP2 maximum counting speed selector 30 Hz (See note 1.) 5 kHz SW1: SW4-1: Manual reset selector Manual reset possible (See note 1.) Manual reset not possible SW4-2: UP/DOWN selector Up counting (incrementing) (See note 1.) Down counting (decrementing) SW1: SW3-2: CP2 maximum counting speed selector 30 Hz (See note 1.) 5 kHz SW3-2: CP2 maximum counting speed selector 30 Hz (See note 1.) 5 kHz SW3-3: Power failure memory backup 30 Hz (See note 1.) 5 kHz SW3-3: Power failure memory backup Memory backup (See note 1.) No memory backup Memory backup (See note 1.) No memory backup SW4: Manual reset selector Manual reset possible (See note 1.) Manual reset not possible (B) Counting function selector SW3-1: CP1 maximum counting speed selector 30 Hz (See note 1.) 5 kHz SW3-3: Power failure memory backup Memory backup (See note 1.) No memory backup (A) Counting function selector SW3-1: CP1 maximum counting speed selector SW4: Manual reset selector Manual reset possible (See note 1.) Manual reset not possible SW3-3: Power failure memory backup Memory backup (See note 1.) No memory backup SW4-1: Output phase selector for first transistor output section LH (at count-out) (See note 1.) HL (at count-out) SW4-2: Output phase selector for second transistor output section LH (at count-out) (See note 1.) HL (at count-out) Note: 1. These settings are the defaults for the specification selection switches. 2. Specifications selected using the internal specification selection switches become after switching once a reset has been performed (e.g., power supply reset, external reset, or manual reset, but not automatic reset). If a reset is not performed, operation will continue with the specifications before switching. SW4-3: Set value read selector Always read (See note 1.) Read only at reset SW4-4: Manual reset selector Manual reset possible (See note 1.) Manual reset not possible 12 H7AN SW1 (A) Counting function selector Switch position SW2 Function (A) Operating mode selector (1-stage preset models) Switch position Function 0, 1, 8, 9 (See note.) Up/Down A (command inputs) Up/Down B (individual inputs) 0, 7, 8, F (See note.) N (count stop, output hold) 2 3 Up/Down C (differential phase inputs) 1, 9 F (overcount, output hold) 4, 5 Up/Down D (command inputs) 2, A C (automatic reset, one-shot output) 6 Up/Down E (individual inputs) 3, B R (automatic reset, one-shot output 1) 7 Up/Down F (differential phase inputs) 4, C K (overcount reset, one-shot output) Note: These settings are the defaults. SW1 (B) Counting function selector Switch position 0, 1 5, D P (automatic reset, one-shot output 2) 6, E Q (automatic reset, one-shot output 3) Note: These settings are the defaults. Function SW2 Up/Down A (command inputs) 2 Up/Down B (individual inputs) 3 Up/Down C (differential phase inputs) 4, 5 Up/Down D (command inputs) Up/Down E (individual inputs) 7 Up/Down F (differential phase inputs) DOWN 9 (See note.) UP Switch position 0, 7 (See note.) 6 8 (B) Operating mode selector (2-stage preset models) Note: These settings are the defaults. Second-stage function First-stage output hold N (count stop, output hold) 1 F (overcount, output hold) 2 C (automatic reset, one-shot output) 3 R (automatic reset, one-shot output 1) 4 K (overcount reset, one-shot output) 5 P (automatic reset, one-shot output 2) 6 Q (automatic reset, one-shot output 3) 8, F 9 A First-stage one-shot output N (count stop, output hold) F (overcount, output hold) C (automatic reset, one-shot output) B R (automatic reset, one-shot output 1) C K (overcount reset, one-shot output) D P (automatic reset, one-shot output 2) E Q (automatic reset, one-shot output 3) Note: These settings are the defaults. Dimensions Note: All units are in millimeters unless otherwise indicated. Panel Cutouts 82 10.5 Two mounting brackets M3.5 screw Radius: 0.5 max. 68 +0.7 -0 68 +0.7 -0 10 @67.6 87.6 72 19 72 100 min. 83 15 115 (When N units are flush-mounted horizontally.) Note: 1. The panel cutouts for the H7AN are as shown (according to DIN437000). 2. The recommended mounting panel thickness is from 1 to 5 mm. 3. Use the mounting bracket (sold together) to mount the digital counter. Radius: 0.5 max. 68 +0.7 -0 (n-1) x 72 + 70 min. (including a tolerance of 2 mm) 13 H7AN Mounting Mounting brackets are included with the H7AN. Use these brackets to mount the H7AN securely so that there is no play. Turn the screws on the mounting brackets counterclockwise to loosen them sufficiently. Attach the bottom mounting bracket first. After attaching the mounting brackets, turn the screws clockwise to tighten them sufficiently. When the screws are completely tightened, you will hear the threads disengage. Installation Terminal Arrangement 1-stage Preset Counters 0V Reset input CP2 input 2-stage Preset Counters CP1 input 12 V (-) 0V (+) 8 9 10 11 Reset input CP2 input CP1 input 12 V (-) 12 13 14 (+) 8 9 10 11 12 13 14 1.5 k Input resistance 4.7 k Input resistance 4.7 k Power supply circuit Input resistance 4.7 k 1.5 k Input resistance 4.7 k External power supply (12 V) Solid-state output Contact output Input resistance 4.7 k 1.5 k External power supply (12 V) Solid-state output 2nd output 1st output Contact output 2nd output 1st output Power supply circuit Surge absorber 1 Input resistance 4.7 k Surge absorber 2 3 4 5 6 7 Open terminal 1 2 Ground terminal 3 4 5 6 7 Ground terminal Power supply input Power supply input Total Counters 0V Reset input CP2 input CP1 input 12 V (-) Open terminals (+) 8 9 Input resistance 4.7 k 10 11 Input resistance 4.7 k Input resistance 4.7 k 12 13 14 6 7 External power supply (12 V) Power supply circuit Surge absorber 1 2 3 4 Ground terminal 5 Note: 1. The polarities of the DC power supply terminals are as follows: Terminal 1: negative; terminal 2: positive 2. If there is excessive external noise, terminal 3 must be grounded to an appropriate place where the grounding resistance is 100 max. There will be a current leakage of 0.2 mA each from terminals 1 and 2 to terminal 3. 3. The open terminals cannot be used as relay terminals. 4. Insert surge absorbers between each of the power supply terminals and the ground terminal. If the ground terminal is not used, insert the surge absorbers between terminal 1 and terminal 2. Open terminals Power supply input Connections Transistor Inputs (NPN Transistors) The CP1, CP2, and reset inputs of the H7AN must be voltage inputs. 14 H7AN Transistor Contact Input Signal Levels 1. High level: 4.5 V min. 4.7 k x E/(4.7 k + R1 or R2) must satisfy the above level.E: 30 VDC max. (12 VDC if power is supplied from the external power supply.) 2. Low level: 2 V max. H7AN H7AN (+) Sensor R1 (+) Sensor R2 (CP1) (CP2) Reset (-) H7AN External resistor (CP1) (CP2) Reset (-) High level: Transistor: OFF High level: Transistor: OFF Contact Inputs Sensor (+) R3 (CP1) (CP2) Reset (-) High level: PNP Transistor: ON; R3 is optional. Input Conditions of the H7AN H: 5 to 30 V L: 0 to 2 V For contact inputs, the contact must have a switching capacity of 2.5 mA min. at 12 V. If a 680-W resistor (1/2 W) is used for R4, reliability will be improved. Sensor H7AN (+) (CP1) (CP2) Reset (-) R4 High level: Contact: ON Connections of Single Transistor Inputs The following illustrations show how to connect a single transistor input to digital counters connected in parallel. The H7AN has an input resistance of 4.7 kW. If the number of counters is N, the total input resistance will be 4.7/N kW. In this case, the high level input signal voltage can be calculated as follows: (4.7/N) x E/(4.7/N + R) Determine the value of E (V) and R (kW) so that the high level input signal voltage will be 5 to 30 VDC. +E( V ) R (K) 4.7/N (K) (-) 8 9 10 11 12 13 14 8 4.7 k H7AN 1 2 3 4 5 8 9 10 11 12 13 14 4.7 k 11 H7AN 6 7 1 2 3 4 5 6 7 N Connections of Single Contact Inputs The following illustrations show how to connect a single contact input to digital counters connected in parallel. If the number of digital counters is N, the total contact input current will be 2.5 x N (mA) at 12 VDC. Reset input CP2 input contact CP1 input contact 8 9 10 11 12 13 14 2 3 4 5 9 10 11 12 13 14 8 9 1011 H7AN 1 8 6 7 H7AN 1 2 3 4 5 6 7 N 15 H7AN Transistor Outputs (One-stage Counters) Load Operation when Transistor is ON External power supply for Load Load Operation when Transistor is OFF Connected to the input The output voltage (V out) terminals of other equipment is calculated as follows: Vout = 9 10 11 13 12 8 14 9 +12 V 2 10 11 External power supply 1.5 K 3 V out Load (= RL) 12 13 14 6 7 +12 V External power supply 1 (V) Load Sensor 8 12 RL 1.5 (k) + RL 5 4 7 6 1 Power supply for load Load * External power supply for load 2 3 1.5 K 4 5 Load Power supply for load (+) 30 VDC max. Load (-) 8 9 10 11 12 13 14 +12 V *This diode is necessary if the supply voltage is below 12 V. External power supply Note: 1. The total current consumption of the sensor and load must not exceed the capacity of the external power supply (80 mA). 1.5 W 2. 1 2 3 1-stage counter (typical) 4 5 6 Load 7 The capacity of the load must not exceed the switching capacity of the transistor (100 mA). 3. The polarities of the power supply terminals are not reversible. Check connections before applying voltage to the power supply terminals to avoid damaging the Counter. Power supply for load 16 H7AN Safety Precautions Be sure to read the precautions for all Counters in the website at: http://www.ia.omron.com/. Warning Indications CAUTION Precautions for Safe Use Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or in property damage. Precautions for Safe Use Supplementary comments on what to do or avoid doing, to use the product safely. Precautions for Correct Use Supplementary comments on what to do or avoid doing, to prevent failure to operate, malfunction or undesirable effect on product performance. Meaning of Product Safety Symbols Used to warn of the risk of electric shock under specific conditions. Used for general prohibitions for which there is no specific symbol. Used for general mandatory action precautions for which there is no specified symbol. CAUTION Do not touch the terminals while power is being supplied. Doing so many occasionally result in minor injury due to electric shock. Do not use the product where subject to flammable or explosive gas. Otherwise, minor injury from explosion may occasionally occur. * Make sure the proper product is specified for the application. * For correct use, do not subject the timer to the following conditions. * Dramatic temperature fluctuations * High humidity or where condensation may occur * Severe vibration and shock * Where excessive dust, corrosive gas, or direct sunlight may be present * This product is not waterproof or oil resistance. Do not use the product in any of the places subject to splashing liquid or oil atmosphere. * Use and store the product within the rated ranges given for the product model you are using. If necessary, use forced cooling. If the product is stored below -10C, allow it to warm up for three hours at room temperature before turning On the power supply. * Do not cover the vent holes on the products and the area around the product in order to ensure thermal dissipation. * Wiring all terminals correctly. * Do not wire the terminals which are not used. * Use specified size crimped terminals (M3.5, thickness 7.2 mm max.) for wiring with a gage of AWG 24 to AWG 18 (equal to a cross section area of 0.205 to 0.823 mm2). (The wiring stripping length is 5 to 6 mm.) Up to two wires of same size and type, or two crimped terminals can be inserted into a single terminal. * Use this product within the rated power supply voltage and control output. * Use a switch, relay, or other contact to turn the power supply ON instantaneously. If the voltage is applied gradually, the power may not be reset or output malfunctions may occur. * Interlock the power to the product with a relay so that the product will not be left in an output on condition for long periods. Leaving the product in an output-on condition for a month or longer, especially in places with high temperatures, may result in deterioration to internal parts, such as an electrolytic capacitor. * Do not apply the supply voltage directly from external to transistor output. Never disassemble, modify or repair the product or touch any of the internal parts. Minor electric shock, fire, or malfunction may occasionally occur. The life expectancy of output relays varies considerably with the output load and switching conditions. Always consider the application conditions and use the output relays within their rated load and electrical life expectancy. If the output relays are used past their life expectancy, contact fusing or burning may occasionally occur. Also, never exceed the rated load current. When using a heater, surely use a thermo switch in the load circuit. Tighten the terminal screws to between 0.74 and 0.90 N*m. Loose screws may occasionally result in fire. Do not allow pieces of metal, wire clippings, or fine metallic shavings or filings from installation to enter the product. Doing so may occasionally result in electric shock, fire, or malfunction. 12 13 External power supply 14 or or 8 or * A constant reading system is used in the present counter, so settings can be changed while power is being supplied, but the output will turn ON if the set value is set to the current measurement value. (If a setting switch is accidentally touched during operation, the set value will be changed and the new set value will be used for operation. Always leave the front panel cover closed unless you are changing a setting.) * When changing the set count while power is being supplied, an inadequate push of the thumb wheel switches will display two numbers in one display window, causing the operating count to drift widely. Therefore, press the thumb wheel switches surely. * Turn the power OFF first when removing the body from the case, never touch the terminals or electronic components with your hands or subject them to shock. When inserting the body, do not allow electronic components to come in contact with the case. * Static electricity may destroy internal components. When removing the body form the case, do not touch an electronic components other than the setting switches with your hands. 17 H7AN * Check that the LED indicators are operating normally. Depending on the operating environment, the indicators and plastic parts may deteriorate faster than expected, causing the indicators to fail. Periodically perform inspections and replacements. * Use tools when separating parts for disposal. * When disposing of the product, observer all local ordinances as they apply. Precautions for Correct Use * Inrush current will be carried when turning on the power. If the capacity of the power for the product is insufficient, the product cannot start. Use a power supply, breakers, contacts which sufficient capacity. 100 to 240 VAC specifications Approx.23 A for 264 VAC 12 to 24 VDC specifications Approx.15 A for 26.4 VDC * After turning ON the power supply, 50 ms is required for the internal circuits to reach the operating voltage. Operation for input signals may not be correctly during this time. * After turning OFF the power supply, 50 ms is required for voltage in the internal circuits to drop. Operation may be performed for input signals during this time. Power 50 ms Possible When an error has occurred, the bellow error codes are shown. 7 segment display Counting operation unstable * Models without power failure memory backup or models ending with "-M" (when memory backup is disabled) will operate as shown in the following figure if the power supply is momentarily interrupted. Power * The product memorizes the status just before occurring the electric failure memory with non-volatile memory. The rewriting lifespan of the non-volatile memory is 1,000,000 or more. The non-volatile memory rewrites the setting condition into the initial setting one when the power OFF and reset input. (-M type only) Self-diagnostic Function ON OFF 50 ms Reception of input signal Retaining Data during Power Interruptions Reset display Operation after power interruption Description Output e1 OFF OFF CPU error OFF e2 OFF OFF Memory error (RAM) OFF e3 OFF OFF Memory error (non-volatile memory)* OFF ON OFF Momentary power interruption Count up display * Including the case when the rewriting lifespan of the nonvolatile memory is reached. Recovery method 0.5 s min. Displays and outputs will be reset. 0.01 s max. The status before the power interruption will be held. 0.01 to 0.5 s Operation will be unstable, i.e., one of the above operations will be performed. Note: Use a Counter with power failure backup memory (models ending with -M) and enable memory backup if holding the status before the power failure is required when the power is interrupted. * The following timing chart shows how the H7AN indicates when there is an external or manual reset input. Reset ON OFF ON Reset indicator OFF Count display Display before reset Off Display after reset * To mount the casing on the digital counter, insert the digital counter body into the casing by hand as far as possible and then tighten the mounting screw. Press by the hand the front panel as indicated by the arrow so that the screw will tighten securely. As an action, turn the power OFF then back ON again. If the display restored to normal, then a probable cause can be external noise affecting the system. Check for external noise. In the case of e3, if the display remains the same even when turn power ON again, input reset. After that, if it still remains the same, the product must be repaired. Changes in Specifications This product was upgraded in January 2006. The main changes are described below. 1. Maximum Counting Speeds A DIP switch on models with 4, 6, or 8 digits could be used to set the maximum counting speed to 3 kHz, 5 kHz, or 30 kHz. The upgraded models have been changed so the maximum counting speed can be set to 5 kHz or 30 kHz. 2. Addition of Setting to Enable/Disable Data Backup for Power Interruptions On models that back up data when power is turned OFF (models with model numbers ending in "-M"), a DIP switch setting has been provided to enable or disable backup. 3. Changes in Functions Allocated to Function Setting Switches Some of the functions allocated to the DIP switches have been changed to allow for the changes described in 1 and 2, above. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 18 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron's exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron's sole obligation hereunder shall be, at Omron's election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron's analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer's application or use of the Product. At Buyer's request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer's application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user's programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron's test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron's Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron's representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2014.4 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2014 All Right Reserved. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: H7AN-RT8-AC100-240 H7AN-W4DM AC100-240 H7AN-2D DC12-24