SCA3000-E02 Data Sheet SCA3000-E02 3-AXIS ULTRA LOW POWER ACCELEROMETER WITH DIGITAL I2C INTERFACE Features * * * * * * * * * * * 2.35 V - 3.6 V supply voltage, 1.7 V - 3.6 V digital I/O voltage 3 g measurement range I2C digital interface: V2.1 compliant, 10-bit addressing, supports standard mode Selectable frequency response Ultra low current consumption (2.5 V, 200 A typ) 64 samples/axis buffer memory for output acceleration data and advanced features enable significant power and resource savings at system level Interrupt signal triggered by motion and free fall Size 7x7x1.8 mm Proven capacitive 3D-MEMS technology High shock durability RoHS compliant / lead free soldering C/V Oscillator & clock Reference Analog calibration & ADC DEMUX 1:3 Non-Volatile Memory Applications SCA3000-E02 is targeted to battery operated wrist and hand-held devices. Typical applications are but not limited * Motion activated functions in mobile terminals and antitheft systems * Gaming input devices * Inclination sensing in digital inclinometers * Tilt compensation in electronic compass * Hard disk protection * Pedometers and activity monitors Low-pass Filter Decimation Low-pass Filter Decimation Low-pass Filter Decimation Motion detector SCL Coordinate Mapping and Calibration Free fall detector 2 IC i/f Ring Buffer SDA Control & INT INT Figure 1 SCA3000-E02 Block Diagram VTI Technologies Oy www.vti.fi 1/4 Doc. Nr. 8256000B.0 Rev.B.0 SCA3000-E02 Performance Characteristics 1) Parameter Analog and digital Vdd Digital I/O Vdd Operating temperature ** Current consumption * Acceleration range * 4) Offset calibration error * Offset temperature error ** 5) Sensitivity * 6) Sensitivity calibration error * Sensitivity temperature error ** 7) Non-Linearity ** 8) Cross-Axis sensitivity ** 9) Bandwidth ** 10) Noise ** 11) Output data rate ** Turn on time ** 12) I2C clock rate ** * ** 1) 2) 3) 4) 5) 6) 7) 8) 9) 10) 11) 12) Condition Vdd Digital I/O Vdd Reset 3) Active Motion Detection mode Nominal Z-axis +1g position -40 ... +85 C -40 ... +85 C Measurement mode Narrow band measurement mode Measurement mode Narrow band measurement mode Measurement mode Narrow band measurement mode Measurement mode Narrow band measurement mode Typical supply range 2.35 - 2.7 V Min Typ 2) Max Extended supply range 2.7 - 3.6 V Min Typ 2) Max 2.35 1.7 -40 - 2.5 1.8 / 2.5 <7 200 170 2.7 2.7 85 12 240 210 -40 - 3.3 3.3 <9 250 210 85 - V V C A A A -3 -40 -3 -1.5 - 0.8 1000 0.01 3 40 3 - 3 100 0.8 1000 1 0.01 - g mg mg/C Count/g % %/C -3 32 9 1 3 40 11 3 48 13 - 1 3 40 11 - % FS % Hz Hz - 9 5 18 10 - 9 5 - mg RMS mg RMS 100 50 125 63 150 75 - 130 63 - Hz - 30 200 70 400 - 30 200 - ms +1.5 100 100 100% tested in production Qualified during product validation The product is factory calibrated at 2.5 V in room temperature. Typical values are not guaranteed. Includes the current through the internal 400 k pull-up resistor connected to digital I/O Vdd. Range defined as x 2+ y 2+ z 2 3g . The measuring range is tested on sensing element level. FS = 3g. Units kHz Offset temperature error = {Count(0g)-Offset} / Sensitivity [ g ]. Sensitivity = Calibrated sensitivity. Offset= Calibrated offset. Sensitivity = {Count(+1g) - Count(-1g)}/2 [Count/g]. Sensitivity temperature error = {[Count(+1g)-Count(-1g)]/2 - Sensitivity} / Sensitivity x 100% [%]. Sensitivity = Calibrated sensitivity. From straight line through sensitivity calibration (+1g, -1g) points. The cross-axis sensitivity determines how much acceleration, perpendicular to the measuring axis, couples to the output. The total cross-axis sensitivity is the geometric sum of the sensitivities of the two axes which are perpendicular to the measuring axis. The angular alignment error between X, Y and Z axis is included into the cross axis sensitivity. Frequency responses according to Figure 3 and Figure 4. Average noise/axis over the measurement bandwidth defined as 1 (n 2 + n 2 + n 2 ) , where nx, ny and nz are y z 3 x the measured signal's standard deviation due to noise in x, y and z directions. Settling error less than 1% of FS. VTI Technologies Oy www.vti.fi Doc. Nr. 8256000B.0 2/4 Rev.B.0 SCA3000-E02 Figure 2 Sensing directions and package dimensions in mm with 50 m tolerance. Figure 3 Frequency response of SCA3000-E02 in measurement mode VTI Technologies Oy www.vti.fi Figure 4 Frequency response of SCA3000-E02 in bypass measurement mode Doc. Nr. 8256000B.0 3/4 Rev.B.0 SCA3000-E02 Figure 5 Application schematic Pin # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Name NC XRESET INT CLK DVSS DVDD DVIO CSB NC NC SCK_SCL MISO_SDA MOSI AVDD AVSS AVSS ATSTIO NC Function Not connected External reset, active low Interrupt output Digital ground Digital ground Digital supply Digital I/O supply Not connected Not connected Not connected I2C clock (SCL) I2C data (SDA) Not connected Analog supply Analog ground Analog ground Not connected Not connected Table 1 Pin descriptions Document Change Control Rev. A A.01 A.02 B Date 21-Apr-06 13-Jun-06 31-Oct-07 28-Aug-08 VTI Technologies Oy www.vti.fi Change Description 1st official release Dimensions updated Figure 2 updated Performance characteristics updated Doc. Nr. 8256000B.0 4/4 Rev.B.0