Embedded Power for Business-Critical Continuity Rev. 03.24.08 LPT60 Series 1 of 3 LPT60 Series RoHS 60 Watts Total Power: Input Voltage: # of Outputs: 60 - 80 Watts 85 - 264 VAC 120 - 300VDC Triple Electrical Specifications Special Features * * * * * * * * * * Universal input 3" x 5" footprint Remote sense on main output Built-in EMI filter Low output ripple Adjustable main output Overvoltage protection Overload protection 110 KHz switching frequency LPX60 enclosure kit available Input Input range: Frequency: Inrush current: Input current: Efficiency: EMI: Safety ground leakage current: 85-264VAC 120-300VDC 47-440Hz <18A peak @ 115VAC; <36A peak @ 230VAC, cold start @ 25C 1.5A max. (RMS) @ 115VAC 70% typical at full load (60% for LPT61) FCC Class B conducted; CISPR 22 Class B conducted EN55022 Class B conducted; VDE 0878 PT3 Class B conducted <0.5 mA @ 50/60 Hz, 264 VAC input Output Maximum Power: Safety VDE: 0805/EN60950 (IEC950) 11774-3336-1255 (LC #86665) UL: UL1950 E132002 CSA: CSA 22.2-234 Level 3 LR53982C NEMKO: EN 60950/EMKO-TUE P95100123 (74-sec) 203 CB: Certificate and report 1518, 1519, 1520 CE: Mark (LVD) Cross regulation: Adjustment range: Hold-up time: Overload protection: Overvoltage protection: Remote sense: 60W for convection (LPT61, 35W); 80W with 30CFW forced air (LPT61, 55W) 2% on output 1; 5% on outputs 2, 3 -5, +10% minimum 20ms @ 40W load, 115 VAC nominal line Short circuit protection on all outputs. Case overload protected @ 110% to 145% above peak rating 5.7 to 6.7 VDC on the main output LPT41: 3.6 to 4.6VDC Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. Embedded Power for Business-Critical Continuity Rev. 03.24.08 LPT60 Series 2 of 3 Environmental Specifications Operating temperature: 0 to 50C ambient derate each output at 2.5% per degree from 50 to 70C, -20C startup Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Electromagnetic susceptibility: Humidity: Operating; non-condensing 5% to 95% Vibration: Storage temperature: Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75G peak 5 Hz to 500 Hz, operational -40 to 85C Temperature coefficient: .04% per C MTBF demonstrated: >550,000 hours at full load and 25C ambient conditions Ordering Information LPT61 +3.3V +5V +12V 0.7A 0A 0A Maximum Load with Convnection cooling 5A 2.5A 0.5A LPT62 +5V +12V -12V +5V +15V -15V +5V +12V -5V +5V +24V +12V 0.7A 0.3A 0A 0.7A 0.3A 0A 0.7A 0.3A 0A 0.7A 0.1A 0A 7A 3A 0.7A 7A 2.8A 0.7A 7A 3A 0.7A 7A 1.5A 0.7A Model Number Output Voltage LPT63 LPT64 LPT65 Minimum Load Maximum Load with 30CFM Forced Air 8.5A 3.0A 1.0A 8A 3.5A 1A 8A 3.3A 1A 8A 3.5A 1A 8A 2.0A 1A Peak Load1 Regulation2 Ripple P/P (PARD)3 9.5A 3.3A 1A 2% 2% 5% 50mV 50mV 120mV 10A 6A 1.5A 10A 4A 1.5A 10A 6A 1.5A 10A 3A 1.5A 2% 5% 5% 2% 5% 5% 2% 5% 5% 2% 7% 5% 50mV 120mV 120mV 50mV 150mV 150mV 50mV 120mV 50mV 50mV 240mV 120mV 1. Peak current lasting <30 seconds with a maximum 10% duty cycle. 2. At 25C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 F in parallel with a 0.1 F capacitor at rated line voltage and load ranges. 4. Minimum Loads are required. Power Derating Curve 80W 30 CFM Forced Air Cooling Output Power (Watts) 60W 40W 20W Natural Convection Cooling 40W 30W 0W 0C 10C 20C 30C 40C 50C 60C 70C TA - Ambient Temperature - C Embedded Power for Business-Critical Continuity Americas Mechanical Drawing 0.22" (5.6) M2 GND M1 SK201 3.00" (76.2) 1 2 3 4 5 6 2.55" (64.8) SK 1 1 N 3 L 4.56" (115.8) 0.22" (5.6) _+ Remote Sense Connector Voltage Adj. Pot SK 2 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Asia (HK) 0.15" (4) DIA (4 places) 5.00" (127) 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 (760) 930 4600 Facsimile: +1 (760) 930 0698 Rev. 03.24.08 LPT60 Series 3 of 3 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 For global contact, visit: www.powerconversion.com techsupport.embeddedpower @emerson.com 1.69" (42.9) While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. 0.12" (3) Pin Assignments Connector LPT61 LPT62 LPT63 LPT64 LPT65 SK1-1 SK1-3 Neutral Line Neutral Line Neutral Line Neutral Line Neutral Line SK2-1 SK2- 2 SK2- 3 SK2-4 SK2-5 SK2-6 SK201-1 SK201-2 5V 3.3V 3.3V Common Common +12V +Sense -Sense +12V +5V +5V Common Common -12V +Sense -Sense +15V +5V +5V Common Common -15V +Sense -Sense +12V +5V +5V Common Common -5V +Sense -Sense +24V +5V +5V Common Common +12V +Sense -Sense Mating Connectors AC Input: DC Outputs: Molex 09-50-8031 (USA) 09-91-0300 (UK) PINS: 08-58-0111 Molex 09-50-8061 (USA) 09-91-0600 (UK) PINS: 08-52-0113 Remote Sense: Molex 22-01-2025 PINS: 08-52-0113 Astec Connector Kit #70-841-006, includes all of the above 1. 2. Specifications subject to change without notice. All dimensions in inches (mm), tolerance is 0.02" (0.5mm) 3. 4. 5. Mounting holes M1 and M2 should be grounded for EMI purposes. Mounting hole M1 is safety ground connection. Specifications are for convection rating at factory settings at 115 VAC input, 25C unless otherwise stated. 6. 7. Warranty: 2 year Weight: 0.75lbs/0.34kg Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection EmersonNetworkPower. com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. (c)2008 Emerson Electric Co.