Bulletin No. BMK6/7-F Drawing No. LP0392 Released 12/14 Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net MODEL BMK6 & BMK7A - BASE MOUNT KIT FOR CUB4, CUB5 & DT8 UNITS DESCRIPTION The BMK6 and BMK7A base mounts are designed for use with the CUB4, CUB5, and DT8 units. The BMK7A is large enough to accommodate a Microline Power Supply (MLPS) attached to a CUB4, CUB5 or DT8. The base mounts are constructed of steel with a textured black finish. Wiring can either be brought through the panel on which the unit is mounted, or through the hole(s) in the enclosure itself. Grommets are provided to insert in the hole(s) on the base mount (where applicable) when wires are routed through it. The grommets are in the accessory bag with each base mount unit, along with four nuts and bolts for mounting. DIMENSIONS In inches (mm) BMK7A - CLOSED BASE MOUNT KIT (With or Without MLPS) BMK6 - OPEN BASE MOUNT KIT (Without MLPS) 2.88 (73.15) 2.88 (73.15) 2.25 (57.15) 2.90 (73.66) 3.50 (88.90) 2.25 (57.15) 2.50 (63.50) 2.25 (57.15) 4.00 (101.50) 4.62 (117.35) 3.25 (82.55) 3.38 (85.85) 3.25 (82.55) INSTALLATION BMK6 - Open Base Mount Before attaching the BMK6 to the panel or frame, it is recommended to wire and mount the unit to ensure good electrical connections. The following steps outline the most common sequence for installing a unit without an MLPS attached. 1. Install the grommet (provided in the accessory bag) in the hole in the base mount. BASE MOUNT 2. Assemble nut fastener and mounting screw onto both sides of the mounting clip. The tip of the screw should not project from the hole in mounting clip. 3. Slide the panel gasket over the rear of the unit to the back of the bezel. GASKET Then install the unit through the opening in the front of the base mount until the bezel flange makes contact. 4. Slide the mounting clip over the rear of the unit until the LATCHING mounting clip is against the inside of the base mount. FEATURE The mounting clip has latching features which engage into mating features on the unit's housing. Note: It is necessary to hold the unit in place when sliding the mounting clip into position. 5. Alternately tighten each screw to ensure uniform gasket compression. 6. Connect the necessary wires from the grommet to the unit. 7. Mount the base mount enclosure to the panel or frame as application requires. Four bolts and nuts are provided with the Base Mount Kit. UNIT 3.50 (88.90) NUT FASTENER LATCHING FEATURE MOUNTING SCREW GROMMET HOLE INSTALLATION SCREW TERMINALS FROM REAR OF UNIT BMK7A - Closed Base Mount Before attaching the BMK7A to the panel or frame, it is recommended to wire and mount the unit to ensure good electrical connections. The following steps outline the most common sequence for installing a unit with an MLPS attached. NUT FASTENER 1. Install the grommets (provided in the accessory bag) in the holes in the base mount. 2. Slide the panel gasket over the rear of the unit to the back of the bezel. BASE MOUNT MLPS HEX STAND-OFF (2 TYP) 3. Remove the common and V+ screw terminals from the rear of the unit (save for later use), and replace GASKET them with the hex drive standoffs with round washers (supplied with the MLPS). LATCHING 4. Assemble nut fastener and mounting screw onto both sides of the mounting clip. The tip of the screw should not project from the hole in mounting clip. SQUARE 2 WASHER LATCHING FEATURE MOUNTING SCREW MOUNTING CLIP FEATURE 5. Route the wires from the grommets, through the mounting clip, into the rear of the base mount and out the front. Note: It is necessary to hold the unit in place when sliding the mounting clip into position. UNIT 9. Alternately tighten each screw to ensure uniform gasket compression. 10. Connect AC power to the terminal block of the MLPS. Note: Make sure the AC selector switch is set to the appropriate position before applying power to the unit. 6. Connect the wires necessary for the application to the unit. 7. Install the unit through the opening in the front of the base mount until the bezel flange makes contact. 11. Mount the MLPS and optional sensor wires needed to the stand-offs using the screw terminal from the unit with the supplied square washers. 8. Slide the mounting clip over the rear of the unit until the mounting clip is against the inside of the base mount. The mounting clip has latching features which engage into mating features on the unit's housing. 12. Mount the base mount enclosure to the panel or frame as application requires. Four bolts and nuts are provided with the Base Mount Kit. ORDERING INFORMATION MODEL NO BMK Red Lion Controls Headquarters 20 Willow Springs Circle York PA 17406 Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 DESCRIPTION PART NUMBER OPEN BASE MOUNT KIT BMK60000 CLOSED BASE MOUNT KIT BMK7A000 Red Lion Controls Europe Softwareweg 9 NL - 3821 BN Amersfoort Tel +31 (0) 334 723 225 Fax +31 (0) 334 893 793 Red Lion Controls India 201-B, 2nd Floor, Park Centra Opp 32 Mile Stone, Sector-30 Gurgaon-122002 Haryana, India Tel +91 984 487 0503 Red Lion Controls China Unit 302, XinAn Plaza Building 13, No.99 Tianzhou Road ShangHai, P.R. China 200223 Tel +86 21 6113 3688 Fax +86 21 6113 3683