Remote Systems Single Signal Remotes M12 - M18 Sn 1.5 - 5.0mm Number of Signals Housing Size Mounting Rated Sn / Gap Distance Assured Sn / Gap Distance Transmitter c*****e Output Sensor Transmitter c*****e Output Sensor 1 Signal M12 X 1 flush/non flush 2mm 0...1.6mm 1 Signal M18 X 1 flush/non flush 5mm 0...4.0mm Transmitter Exclusive Proximity Sensors BES-RXT-1202-J-01 Exclusive Proximity AND Signal N/A Mechanical Limit Switch BES-RST-1202-J-01 Output Sensor PNP Output NPN Output Sensing Distance Rated operational voltage Short circuit protection Current Consumption Load Capacity Operation Frequency Ambient temperature range Function indication Passive Remote Systems M12 X 1 flush/non flush BES-RXT-1805-J-01 BES-RAT-1805 BES-RST-1805 BES-RXE-1805-P-02 BES-RXE-1805-N-02 BES-RXE-1202-P-02 BES-RXE-1202-N-02 0..2.0mm non-Flush / 0..1.6mm flush 24V DC 5% yes 25mA max. 100mA 25 Hz 0..+50 C 0..+50 C no yes IP67 Environmental protection (per IEC529) IP67 Nickel Plated Brass Housing material Nickel Plated Brass ABS + PBT Sensing face material ABS + PBT PVC Cable Material PVC 1M, 5mm, 2X20AWG Cable Length / Diameter / AWG 2M, 5mm, 3X20AWG Basic Remote Sensor System Wiring Schematics * RX * RA * RS series 0..5.0mm non-Flush / 0..4.0 flush 24V DC 5% yes 25mA max. 100mA 25 Hz 0..+50 C 0..+50 C no yes IP67 Nickel Plated Brass ABS + PBT PVC 1M, 5mm, 2X20AWG Exclusive Proximity Sensors Mechanical Limit Switch [Detector] [Detector] RXD [Transmitter] [Output Sensor] RXT M18 X 1 flush/non flush Mechanical limit SW RXE IP67 Nickel Plated Brass ABS + PBT PVC 2M, 5mm, 3X20AWG [Transmitter] [Output Sensor] RST RXE Exclusive Proximity AND Signal [Detector] [Transmitter] [Output Sensor] RXD RAT RXE RXD T 5.8 1-800-543-8390 WWW.BALLUFF.COM Passive Remote Systems Remote Systems Single & Multiple Signal Remotes M18 - M30 Sn 10mm, 5mm Transmitter c*****e Output Sensor Transmitter c*****e Output Sensor 1 Signal M30 X 1 flush/non flush 10mm 0...8.0mm 8 Signals M18 X 1 flush/non flush 5mm 1.0...4.0mm M30 X 1 flush/non flush BES-RXT-3010-J-01 BES-RAT-3010-J-01 BES-RST-3010-J-01 BES-RFTA-1805-S-01 BES-RXE-3010-P-02 BES-RXE-3010-N-02 0..10mm non-Flush / 0..10mm flush 24V DC 5% yes 25mA max. 100mA 25 Hz 0..+50 C 0..+50 C yes no IP67 Nickel Plated Brass ABS + PBT PVC 1M, 5mm, 2X20AWG M18 X 1 flush/non flush IP67 Nickel Plated Brass ABS + PBT PVC 2M, 5mm, 3XAWG 1-800-543-8390 WWW.BALLUFF.COM BES-RFEA-1805-PS-02 BES-RFEA-1805-NS-02 5 0..5.0mm non-Flush / 0..4.0 non flush 24V DC 5% yes 40mA max. 50mA per Output 3.2 Hz 0..+50 C 0..+50 C no yes IP67 Nickel Plated Brass ABS + PBT PVC 1M, 7mm, 12X26AWG IP67 Nickel Plated Brass ABS + PBT PVC 2M, 7mm, 12X26AWG 5. 9 8 Signal Remotes M12 - M18 Sn 1.5 - 5.0mm Remote Systems Number of Signals Housing Size Mounting Rated Sn / Gap Distance Assured Sn / Gap Distance Passive Remote Systems Transmitter c*****e Output Sensor Transmitter c*****e Output Sensor 8 Signals M30 X 1 flush/non flush 2.0...10.0mm 2.0...8.0mm 8 Signals M30 X 1 Non flush 2.0...18.0mm 2.0...16.0mm M30 X 1 flush/non flush M30 X 1 Non flush Transmitter BES-RFTA-3010-S-03 Output Sensor PNP Output NPN Output BES-RFTA-3018-01 BES-RFEA-3010-PS-02 BES-RFEA-3010-NS-02 2.0...10.0mm Flush / 2.0...8.0mm Non-Flush 24V DC 5% yes 40mA max. 50mA per Output 3.2 Hz 0..+50 C 0..+50 C no yes Sensing Distance Rated operational voltage Short circuit protection Current Consumption Load Capacity Operation Frequency Ambient temperature range Funtion indication Environmental protection (per IEC529) Housing material Sensing face material Cable Material Cable Length / Diameter / AWG IP67 Nickel Plated Brass ABS + PBT PVC 3M, 7mm, 12X26AWG IP67 Nickel Plated Brass ABS + PBT PVC 2M, 7mm, 12X26AWG BES-RFEA-3018-P-02 BES-RFEA-3018-N-02 2.0...18.0mm Non-Flush 0..+50 C no 24V DC 5% yes 40mA max. 50mA per Output 3.2 Hz 0..+50 C yes IP67 Nickel Plated Brass ABS + PBT PVC 1M, 7mm, 12X26AWG IP67 Nickel Plated Brass ABS + PBT PVC 2M, 7mm, 12X26AWG *These Remotes systems work with mechanical switches also. You can mix and match inductive detectors and mechanical switches. Basic Remote Sensor System Wiring Schematics * RF/A series [Detector] [Transmitter] RFTA [Output Sensor] RFEA Terminal box for connecting detectors and transmitters are available as an option. (See Pages 24-25) 5.10 1-800-543-8390 WWW.BALLUFF.COM Passive Remote Detector Sensors Housing Size Mounting Rated Sn Assured Sn M8 X 1 Flush 1.5mm 0...1.2mm M12 X 1 Flush 2mm 0...1.6mm Remote Systems M18 X 1 Flush 5mm 0...4.0mm Passive Detectors RXD M8 - M30 Sn 1.5 - 10mm M30 X 1 Flush 10mm 0...8.0mm RXD Detector Sensors can only be used with the passive remote systems Part Number BES-RXD-0801-J-01 Transmitter Type Ambient temperature range Operating frequency (max.) Funtion indication Environmental protection (per IEC529) Housing material Sensing face material Wire Diameter No. of wires & gauge Cable Material BES-RXD-1202-J-01 BES-RXD-1805-J-01 BES-RXD-3010-J-01* BES-RXD-3010M-J-01** RXT, RAT 0...+50 C 25 Hz No RXT, RAT 0...+50 C 25 Hz No RXT, RAT 0...+50 C 25 Hz No RXT*, RAT* / RFTA** 0...+50 C 25 Hz No IP67 Stainless Steel ABS + PBT 4mm 2 X 0.14mm2 PVC IP67 Nickel Plated Brass ABS + PBT 5mm 2 X 0.5mm2 PVC IP67 Nickel Plated Brass ABS + PBT 5mm 2 X 0.5mm2 PVC IP67 Nickel Plated Brass ABS + PBT 5mm 2 X 0.5mm2 PVC 5 * Can only connect to RXT, RAT transmitters (See pages 8-9) ** Can only connect to RFTA series transmitters (See page 10) The RXD remote detectors work with the RXT, RAT, RFTA Transmitters 1-800-543-8390 WWW.BALLUFF.COM 5.11