JPS250Q.qxd 25/6/03 12:26 pm Page 1 AC/DC U-Channel 250 Watts XPiQ inc. JPS250 Quad Output Series * Intelligent Design Quality Product Active PFC - Meets EN61000-3-2, -3 * 200 W with Convection Cooling * Meets 1U, Low Profile Requirements * Zero Voltage Switching Technology * Remote On/Off / Remote Sense * Optional Current Share Y R A N I M I 3 L 0 E 0 PR 3 2 Q Specification Input AC Input Voltage Input Frequency DC Input Voltage Inrush Current * * * * Input Current * Remote On/Off * Power Factor * 85-264 VAC 47-63 Hz 170-370 VDC 30 A max at 115 VAC 60 A max at 230 VAC 4 A max at 115 VAC 2 A max at 230 VAC Off = Logic High, or +5 V On = Logic Low, or short circuit, or open 0.98 for 115 VAC, 0.90 for 230 VAC * * 5-48 VDC On output #1 only 10% * * * * * * * * 250 Watts 2 A required on V1 0.5% from low line to high line 1% for V1 & V2, 5% for V3 & V4 15% maximum 1% 1% peak to peak maximum 4% max deviation, 500 s recovery time for a 25% load change 0.05%/C Overcurrent Protection Overtemperature Protection Current Share * 120% - 150% with auto recovery * Standard * Single wire current sharing on V1 & V2 (optional) 12 V at 100 mA Fan Output * General Efficiency (typical) Power Density MTBF Withstand Voltage * * * * Size Weight Signals * * * Output Output Voltage Output Voltage Adjustment Output Power Minimum Load Line Regulation Load Regulation Cross Regulation Set Point Accuracy Ripple & Noise Transient Response Temperature Coefficient Hold Up Time Remote Sense Overvoltage Protection * * * * 20 ms minimum at low line V1 & V2 compensates for up to 0.5 V drop 115% to 140%, recycle input to reset >80%, nominal line full load 4.9 W/in3 255,000 hrs min to MIL-HDBK-217F 3000 VAC Input to Output 1500 VAC Input to Ground 500 VAC Output to Ground 8.0" x 4.2" x 1.5" 770 grams approx AC OK = Logic Hi, DC OK = Logic Hi Environmental Operating Temperature Cooling * * Storage Temperature * 0 C to +70 C See Derating Chart Full power to 50 C 250 W with 18 CFM airflow 200 W Convection Cooling -20 C to +85 C Safety and EMC Safety Approvals * EMI/EMC * Immunity & Surge * UL60950, CSA C22.2 No 234, EN60950, CE Mark LVD EN61000-3-2, -3, EN55022 Class B and FCC 20780 Level B conducted EN50082-2 (EN61000-4-2,-3, -4, -5) Performance criteria A * Preliminary datasheet - see website for current specs * 29 www.XPiQ.com PH: 508 429.9883 FAX: 800 226.2100 Email: sales@xpiq.com Holliston, MA 01746 USA * JPS250Q.qxd 25/6/03 12:26 pm Page 2 OUTPUT VOLTAGE & CURRENT RATINGS Output V1 3.3 V 5.0 V 5.0 V 5.0 V Output 1 Conv. Max Cooled 18 CFM 16.0 A 20.0 A 17.5 A 30.0 A 20.0 A 25.0 A 20.0 A 25.0 A Output V2 5.0 V 12.0 V 12.0 V 15.0 V Output 2 Conv. Max Cooled 18 CFM 12.0 A 20.0 A 7.0 A 8.0 A 4.0 A 6.0 A 3.0 A 5.0 A Output V3 12.0 V -12.0 V 24.0 V 24.0 V JPS250Q Output 3 Conv. Max Cooled 18 CFM 5.0 A 6.0 A 2.0 A 3.0 A 2.0 A 3.0 A 2.0 A 3.0 A Output V4 -12.0 V -5.0 V -12.0 V -15.0 V Output 4 Conv. Max Cooled 18 CFM 1.0 A 2.0 A 1.0 A 2.0 A 1.0 A 2.0 A 1.0 A 2.0 A Model Number JPS250PQ46 JPS250PQ41 JPS250PQ47* JPS250PQ48* * Preliminary models JPS250PQ47 & JPS250PQ48 will be released in Q3 2003 - see website for current specs. Notes 1. 2. 3. 4. Maximum power with 18 CFM forced air, is 250 Watts, or 200 Watts with convection cooling. For current share option add suffix "C" to part number. Current share models are built to order. All models require 2 A minimum load on V1. On V2, JPS250PQ46 requires 1 A and JPS250PQ41 requires 0.5 A. * Mechanical Details NOTES: 1. Dimensions shown in inches (mm). 2. Tolerance is 0.8mm max. 3. TB2 signal connector is molex 70246-10 or equivalent. 4. TB5 is for fan, 12V/100 mA with Molex 5045-02A or equivalent. 5. TB1 (AC input) and TB3 (DC output) are terminal blocks. Pin Chart TB2 1 2 3 4 5 6 7 JPS250PQ46 +Sense 3.3 V -Sense 5V Share 3.3 V DC OK +Sense 5 V -Sense 3.3 V Share 5.0 V JPS250PQ41 +Sense 5 V -Sense 5V Share 12.0 V DC OK +Sense 12 V -Sense 5.0 V -Sense 12.0 V * Preliminary models JPS250PQ47 & JPS250PQ48 will be released in Q3 2003 - see website for current specs. TB3 1 2 3 4 5 6 7 JPS250PQ46 3.3 V 3.3 V GND GND GND GND 12.0 V JPS250PQ41 5.0 V 5.0 V GND GND GND -5.0 V -12.0 V 8 Enable Enable 8 -12.0 V 12.0 V 9 AC OK AC OK 9 5.0 V Derating Graph - 250 Watts Application Notes 1. To turn off the output, apply 5 V to the remote ON/OFF. 2. AC OK is a TTL signal which goes LOW when input falls below 60 VAC at rated load. 3. DC OK is a TTL signal which goes LOW when PSU is in an overcurrent condition, overvoltage condition, disabled or when output falls out of regulation. 4. For AC OK and DC OK signals, source current is 1 mA, sink current is 6 mA. * Preliminary datasheet - see website for current specs and application notes. www.XPiQ.com PH: 508 429.9883 FAX: 800 226.2100 Email: sales@xpiq.com Holliston, MA 01746 USA 10 GND GND 10 5.0 V